Document 10861094

advertisement
Proposal 13211 (STScI Edit Number: 0, Created: Wednesday, December 18, 2013 9:42:45 PM EST) - Overview
13211 - WFC3 SS D2 Cal Lamp Test
Cycle: 20, Proposal Category: CAL/WFC3
(Availability Mode: RESTRICTED)
INVESTIGATORS
Name
Dr. John W. MacKenty (PI) (Contact)
Heather Gunning (CoI)
Dr. Sylvia M. Baggett (CoI)
Institution
Space Telescope Science Institute
Space Telescope Science Institute
Space Telescope Science Institute
E-Mail
mackenty@stsci.edu
gunning@stsci.edu
sbaggett@stsci.edu
VISITS
Visit Targets used in Visit
Configurations used in Visit
Orbits Used Last Orbit Planner Run
01
DEUTERIUM
WFC3/UVIS
1
18-Dec-2013 21:42:12.0
OP Current
with Visit?
yes
02
DEUTERIUM
WFC3/UVIS
1
18-Dec-2013 21:42:18.0
yes
03
DEUTERIUM
WFC3/UVIS
1
18-Dec-2013 21:42:24.0
yes
04
DEUTERIUM
WFC3/UVIS
1
18-Dec-2013 21:42:29.0
yes
05
DEUTERIUM
WFC3/UVIS
1
18-Dec-2013 21:42:33.0
yes
06
DEUTERIUM
WFC3/UVIS
1
18-Dec-2013 21:42:37.0
yes
6 Total Orbits Used
ABSTRACT
Part of side switch activities.
This proposal verifies the health and performance of the calsystem deuterium lamp and assesses the status of the major UV filters by taking a full set
of internal flatfields. A total of three nominal and one short exposure are obtained for each filter in order to establish an initial baseline of flatfield
1
Proposal 13211 (STScI Edit Number: 0, Created: Wednesday, December 18, 2013 9:42:45 PM EST) - Overview
data as well as to confirm lamp repeatability and provide a contamination check. Additional iterations of D2 internal flatfields will be taken as part
of WF19, UVIS Internal Flats (proposal 13212).
ID:WF15
OBSERVING DESCRIPTION
Part of side switch activities.
2
Proposal 13211, Visit 01, implementation
Diagnostic Status: Warning
Scientific Instruments: WFC3/UVIS
Special Requirements: (none)
Comments: Exposure times assume medium current. D2 lamp cycles should be minimized to prolong lifetime.
(Visit 01) Warning (Orbit Planner): MAXIMUM DURATION EXCEEDED FOR INTERNAL OR EARTH CALIB SU
#
1
Label
D2 - short
Target
DEUTERIUM
Config,Mode,Aperture
WFC3/UVIS, ACCUM, UVIS
Spectral Els.
F200LP
Opt. Params.
Special Reqs.
CURRENT=MEDIU
M
2
D2 - short
DEUTERIUM
WFC3/UVIS, ACCUM, UVIS
F280N
CURRENT=MEDIU
M
3
D2 - short
DEUTERIUM
WFC3/UVIS, ACCUM, UVIS
F218W
CURRENT=MEDIU
M
4
D2 - short
DEUTERIUM
WFC3/UVIS, ACCUM, UVIS
F225W
CURRENT=MEDIU
M
5
D2 - short
DEUTERIUM
WFC3/UVIS, ACCUM, UVIS
F275W
CURRENT=MEDIU
M
6
D2 - short
DEUTERIUM
WFC3/UVIS, ACCUM, UVIS
F300X
CURRENT=MEDIU
M
Orbit Structure
Exposures
Diagnostics
Visit
Proposal 13211 - Visit 01 - WFC3 SS D2 Cal Lamp Test
3
Thu Dec 19 02:42:46 GMT 2013
Groups
Exp. Time (Total)/[Actual Dur.]
1.7 Secs (1.7 Secs)
[==>]
422. Secs (422 Secs)
[==>]
17.5 Secs (17.5 Secs)
[==>]
8.3 Secs (8.3 Secs)
[==>]
17.4 Secs (17.4 Secs)
[==>]
8.4 Secs (8.4 Secs)
[==>]
Orbit
[1]
[1]
[1]
[1]
[1]
[1]
Proposal 13211, Visit 02, implementation
Diagnostic Status: Warning
Scientific Instruments: WFC3/UVIS
Special Requirements: (none)
Comments: Exposure times assume medium current. D2 lamp cycles should be minimized to prolong lifetime.
(Visit 02) Warning (Orbit Planner): MAXIMUM DURATION EXCEEDED FOR INTERNAL OR EARTH CALIB SU
#
1
Label
Target
D2 - nomina DEUTERIUM
l
Config,Mode,Aperture
WFC3/UVIS, ACCUM, UVIS
Spectral Els.
F200LP
Opt. Params.
Special Reqs.
CURRENT=MEDIU
M
2
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F218W
CURRENT=MEDIU
M
3
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F280N
CURRENT=MEDIU
M
4
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM,
UVIS-QUAD
FQ232N
CURRENT=MEDIU
M
Orbit Structure
Exposures
Diagnostics
Visit
Proposal 13211 - Visit 02 - WFC3 SS D2 Cal Lamp Test
4
Thu Dec 19 02:42:48 GMT 2013
Groups
Exp. Time (Total)/[Actual Dur.]
3.4 Secs (3.4 Secs)
[==>]
35. Secs (35 Secs)
[==>]
845. Secs (845 Secs)
[==>]
475. Secs (475 Secs)
[==>]
Orbit
[1]
[1]
[1]
[1]
Proposal 13211, Visit 03, implementation
Diagnostic Status: Warning
Scientific Instruments: WFC3/UVIS
Special Requirements: (none)
Comments: Exposure times assume medium current. D2 lamp cycles should be minimized to prolong lifetime.
(Visit 03) Warning (Orbit Planner): MAXIMUM DURATION EXCEEDED FOR INTERNAL OR EARTH CALIB SU
#
1
Label
Target
D2 - nomina DEUTERIUM
l
Config,Mode,Aperture
WFC3/UVIS, ACCUM, UVIS
Spectral Els.
F225W
Opt. Params.
Special Reqs.
CURRENT=MEDIU
M
2
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F336W
CURRENT=MEDIU
M
3
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM,
UVIS-QUAD
FQ387N
CURRENT=MEDIU
M
4
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F300X
CURRENT=MEDIU
M
5
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F390M
CURRENT=MEDIU
M
Orbit Structure
Exposures
Diagnostics
Visit
Proposal 13211 - Visit 03 - WFC3 SS D2 Cal Lamp Test
5
Thu Dec 19 02:42:49 GMT 2013
Groups
Exp. Time (Total)/[Actual Dur.]
16.6 Secs (16.6 Secs)
[==>]
58.8 Secs (58.8 Secs)
[==>]
860. Secs (860 Secs)
[==>]
16.8 Secs (16.8 Secs)
[==>]
271. Secs (271 Secs)
[==>]
Orbit
[1]
[1]
[1]
[1]
[1]
Proposal 13211, Visit 04, implementation
Diagnostic Status: Warning
Scientific Instruments: WFC3/UVIS
Special Requirements: (none)
Comments: Exposure times assume medium current. D2 lamp cycles should be minimized to prolong lifetime.
(Visit 04) Warning (Orbit Planner): MAXIMUM DURATION EXCEEDED FOR INTERNAL OR EARTH CALIB SU
#
1
Label
Target
D2 - nomina DEUTERIUM
l
Config,Mode,Aperture
WFC3/UVIS, ACCUM, UVIS
Spectral Els.
F225W
Opt. Params.
Special Reqs.
CURRENT=MEDIU
M
2
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F336W
CURRENT=MEDIU
M
3
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM,
UVIS-QUAD
FQ387N
CURRENT=MEDIU
M
4
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F300X
CURRENT=MEDIU
M
5
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F390M
CURRENT=MEDIU
M
Orbit Structure
Exposures
Diagnostics
Visit
Proposal 13211 - Visit 04 - WFC3 SS D2 Cal Lamp Test
6
Thu Dec 19 02:42:50 GMT 2013
Groups
Exp. Time (Total)/[Actual Dur.]
16.6 Secs (16.6 Secs)
[==>]
58.8 Secs (58.8 Secs)
[==>]
860. Secs (860 Secs)
[==>]
16.8 Secs (16.8 Secs)
[==>]
271. Secs (271 Secs)
[==>]
Orbit
[1]
[1]
[1]
[1]
[1]
Proposal 13211, Visit 05, implementation
Diagnostic Status: Warning
Scientific Instruments: WFC3/UVIS
Special Requirements: (none)
Comments: Exposure times assume medium current. D2 lamp cycles should be minimized to prolong lifetime.
(Visit 05) Warning (Orbit Planner): MAXIMUM DURATION EXCEEDED FOR INTERNAL OR EARTH CALIB SU
#
1
Label
Target
D2 - nomina DEUTERIUM
l
Config,Mode,Aperture
WFC3/UVIS, ACCUM, UVIS
Spectral Els.
F200LP
Opt. Params.
Special Reqs.
CURRENT=MEDIU
M
2
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F218W
CURRENT=MEDIU
M
3
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F280N
CURRENT=MEDIU
M
4
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM,
UVIS-QUAD
FQ232N
CURRENT=MEDIU
M
Orbit Structure
Exposures
Diagnostics
Visit
Proposal 13211 - Visit 05 - WFC3 SS D2 Cal Lamp Test
7
Thu Dec 19 02:42:50 GMT 2013
Groups
Exp. Time (Total)/[Actual Dur.]
3.4 Secs (3.4 Secs)
[==>]
35. Secs (35 Secs)
[==>]
845. Secs (845 Secs)
[==>]
475. Secs (475 Secs)
[==>]
Orbit
[1]
[1]
[1]
[1]
Proposal 13211, Visit 06, implementation
Diagnostic Status: Warning
Scientific Instruments: WFC3/UVIS
Special Requirements: (none)
Comments: Exposure times assume medium current. D2 lamp cycles should be minimized to prolong lifetime.
(Visit 06) Warning (Orbit Planner): MAXIMUM DURATION EXCEEDED FOR INTERNAL OR EARTH CALIB SU
#
1
Label
Target
D2 - nomina DEUTERIUM
l
Config,Mode,Aperture
WFC3/UVIS, ACCUM, UVIS
Spectral Els.
F225W
Opt. Params.
Special Reqs.
CURRENT=MEDIU
M
2
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F336W
CURRENT=MEDIU
M
3
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM,
UVIS-QUAD
FQ387N
CURRENT=MEDIU
M
4
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F300X
CURRENT=MEDIU
M
5
D2 - nomina DEUTERIUM
l
WFC3/UVIS, ACCUM, UVIS
F390M
CURRENT=MEDIU
M
Orbit Structure
Exposures
Diagnostics
Visit
Proposal 13211 - Visit 06 - WFC3 SS D2 Cal Lamp Test
8
Thu Dec 19 02:42:51 GMT 2013
Groups
Exp. Time (Total)/[Actual Dur.]
16.6 Secs (16.6 Secs)
[==>]
58.8 Secs (58.8 Secs)
[==>]
860. Secs (860 Secs)
[==>]
16.8 Secs (16.8 Secs)
[==>]
271. Secs (271 Secs)
[==>]
Orbit
[1]
[1]
[1]
[1]
[1]
Download