Proposal 13093 (STScI Edit Number: 1, Created: Wednesday, October 10, 2012 10:01:56 PM EST) - Overview 13093 - IR Grisms: Wavelength Calibration Monitor Cycle: 20, Proposal Category: CAL/WFC3 (Availability Mode: RESTRICTED) INVESTIGATORS Name Dr. Janice C. Lee (PI) (Contact) Dr. Norbert Pirzkal (CoI) Mr. Bryan Hilbert (CoI) Institution Space Telescope Science Institute Space Telescope Science Institute Space Telescope Science Institute E-Mail jlee@stsci.edu npirzkal@stsci.edu hilbert@stsci.edu VISITS Visit Targets used in Visit Configurations used in Visit Orbits Used Last Orbit Planner Run 02 (1) VY2-2-COPY WFC3/IR 1 10-Oct-2012 23:01:35.0 OP Current with Visit? yes 41 (1) VY2-2-COPY WFC3/IR 1 10-Oct-2012 23:01:49.0 yes 2 Total Orbits Used ABSTRACT This program will observe PN VY22 at 3 different positions using the WFC3 IR G102 and G141 grisms. The data will be used to calculate wavelength solutions for the grisms, and will be compared with those derived from programs 11937, 12355 and 12356 to monitor for potential time evolution of the calibration. OBSERVING DESCRIPTION The PN Vy2-2 is observed as a wavelength calibrator at three different positions in the field though each of the G102 and G141 grisms. "Center," "Lower Center," and "Upper Center" are repeated from the 9-point pattern used in program 11937. As in previous calibration programs, each dispersed exposure is preceeded by two direct images, to measure the source offsets between direct and dispersed modes, and establish the 1 Proposal 13093 (STScI Edit Number: 1, Created: Wednesday, October 10, 2012 10:01:56 PM EST) - Overview wavelength zeropoint for each dispersed exposure. For G102 (G140) observations, the F098M and F105W (F140W and F160W) filters are used for the accompanying direct exposures. The number of FPA readouts (nsamp) is minimized for each exposure in order to avoid as much visibility time lost to buffer dumps as possible. POSTARGs are used to move the target to different locations in the field. POSTARGs are also used at the central exposure of the pattern in order to shift the location of the first-order spectrum so that it is near the center of the FOV. 2 Fixed Targets Visit Proposal 13093 - Visit 02 - IR Grisms: Wavelength Calibration Monitor Proposal 13093, Visit 02 Diagnostic Status: No Diagnostics Scientific Instruments: WFC3/IR Special Requirements: (none) # Name Target Coordinates (1) VY2-2-COPY RA: 19 24 22.2300 (291.0926250d) Alt Name1: PK045-02D1 Dec: +09 53 56.66 (9.89907d) Equinox: J2000 # 1 2 3 4 Exposures 5 6 7 8 9 10 11 12 Thu Oct 11 03:01:57 GMT 2012 Targ. Coord. Corrections Label Target Center F098 (1) VY2-2-COPY M Config,Mode,Aperture WFC3/IR, MULTIACCUM, G102-REF Spectral Els. F098M Center F105 (1) VY2-2-COPY W WFC3/IR, MULTIACCUM, G102-REF F105W Center G102 (1) VY2-2-COPY WFC3/IR, MULTIACCUM, IR G102 Center G102 (1) VY2-2-COPY Center G102 (1) VY2-2-COPY Center G102 (1) VY2-2-COPY WFC3/IR, MULTIACCUM, IR WFC3/IR, MULTIACCUM, IR WFC3/IR, MULTIACCUM, IR G102 G102 G102 Upper Cente (1) VY2-2-COPY r F098M WFC3/IR, MULTIACCUM, G102-REF F098M Upper Cente (1) VY2-2-COPY r F105W WFC3/IR, MULTIACCUM, G102-REF F105W Upper Cente (1) VY2-2-COPY r G102 WFC3/IR, MULTIACCUM, IR G102 Lower Cente (1) VY2-2-COPY r F098M WFC3/IR, MULTIACCUM, G102-REF F098M Lower Cente (1) VY2-2-COPY r F105W WFC3/IR, MULTIACCUM, G102-REF F105W Lower Cente (1) VY2-2-COPY r G102 WFC3/IR, MULTIACCUM, IR G102 Opt. Params. SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=RAPID ; NSAMP=1 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=RAPID ; NSAMP=1 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=RAPID ; NSAMP=1 SAMP-SEQ=SPARS 25; NSAMP=5 3 Fluxes V=13.8 Miscellaneous Reference Frame: ICRS Special Reqs. Groups Exp. Time/[Actual Dur.] POS TARG -20.0,0. Sequence 1-6 Non-In [==>] 0 t in Visit 02 Orbit [1] POS TARG -20.0,0. Sequence 1-6 Non-In [==>] 0 t in Visit 02 [1] POS TARG -20.0,0. Sequence 1-6 Non-In [==>] 0 t in Visit 02 [1] POS TARG -20.5,0. Sequence 1-6 Non-In [==>] 5 t in Visit 02 [1] POS TARG -21.0,1. Sequence 1-6 Non-In [==>] 0 t in Visit 02 [1] POS TARG -21.2,1. Sequence 1-6 Non-In [==>] 2 t in Visit 02 [1] POS TARG -20.0,+4 Sequence 7-9 Non-In [==>] 5.0 t in Visit 02 [1] POS TARG -20.0,45 Sequence 7-9 Non-In [==>] .0 t in Visit 02 [1] POS TARG -20.0,45 Sequence 7-9 Non-In [==>] .0 t in Visit 02 [1] POS TARG -20.0,-4 Sequence 10-12 Non [==>] 5.0 -Int in Visit 02 [1] POS TARG -20.0,-4 Sequence 10-12 Non [==>] 5.0 -Int in Visit 02 [1] POS TARG -20.0,-4 Sequence 10-12 Non [==>] 5.0 -Int in Visit 02 [1] Orbit Structure Proposal 13093 - Visit 02 - IR Grisms: Wavelength Calibration Monitor 4 Fixed Targets Visit Proposal 13093 - Visit 41 - IR Grisms: Wavelength Calibration Monitor Proposal 13093, Visit 41 Diagnostic Status: No Diagnostics Scientific Instruments: WFC3/IR Special Requirements: (none) # Name Target Coordinates (1) VY2-2-COPY RA: 19 24 22.2300 (291.0926250d) Alt Name1: PK045-02D1 Dec: +09 53 56.66 (9.89907d) Equinox: J2000 # 1 2 3 4 Exposures 5 6 7 8 9 10 11 12 Thu Oct 11 03:01:59 GMT 2012 Targ. Coord. Corrections Label Target Center F140 (1) VY2-2-COPY W Config,Mode,Aperture WFC3/IR, MULTIACCUM, G141-REF Spectral Els. F140W Center F160 (1) VY2-2-COPY W WFC3/IR, MULTIACCUM, G141-REF F160W Center G141 (1) VY2-2-COPY WFC3/IR, MULTIACCUM, IR G141 Center G141 (1) VY2-2-COPY Center G141 (1) VY2-2-COPY Center G141 (1) VY2-2-COPY WFC3/IR, MULTIACCUM, IR WFC3/IR, MULTIACCUM, IR WFC3/IR, MULTIACCUM, IR G141 G141 G141 Upper Cente (1) VY2-2-COPY r F140W WFC3/IR, MULTIACCUM, G141-REF F140W Upper Cente (1) VY2-2-COPY r F160W WFC3/IR, MULTIACCUM, G141-REF F160W Upper Cente (1) VY2-2-COPY r G141 WFC3/IR, MULTIACCUM, IR G141 Lower Cente (1) VY2-2-COPY r F140W WFC3/IR, MULTIACCUM, G141-REF F140W Lower Cente (1) VY2-2-COPY r F160W WFC3/IR, MULTIACCUM, G141-REF F160W Lower Cente (1) VY2-2-COPY r G141 WFC3/IR, MULTIACCUM, IR G141 Opt. Params. SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=SPARS 25; NSAMP=5 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=RAPID ; NSAMP=2 SAMP-SEQ=SPARS 25; NSAMP=5 5 Fluxes V=13.8 Miscellaneous Reference Frame: ICRS Special Reqs. Groups Exp. Time/[Actual Dur.] POS TARG -20.0,0. Sequence 1-6 Non-In [==>] 0 t in Visit 41 Orbit [1] POS TARG -20.0,0. Sequence 1-6 Non-In [==>] 0 t in Visit 41 [1] POS TARG -20.0,0. Sequence 1-6 Non-In [==>] 0 t in Visit 41 [1] POS TARG -20.5,0. Sequence 1-6 Non-In [==>] 5 t in Visit 41 [1] POS TARG -21.0,1. Sequence 1-6 Non-In [==>] 0 t in Visit 41 [1] POS TARG -21.2,1. Sequence 1-6 Non-In [==>] 2 t in Visit 41 [1] POS TARG -20.0,+4 Sequence 7-9 Non-In [==>] 5.0 t in Visit 41 [1] POS TARG -20.0,45 Sequence 7-9 Non-In [==>] .0 t in Visit 41 [1] POS TARG -20.0,45 Sequence 7-9 Non-In [==>] .0 t in Visit 41 [1] POS TARG -20.0,-4 Sequence 10-12 Non [==>] 5.0 -Int in Visit 41 [1] POS TARG -20.0,-4 Sequence 10-12 Non [==>] 5.0 -Int in Visit 41 [1] POS TARG -20.0,-4 Sequence 10-12 Non [==>] 5.0 -Int in Visit 41 [1] Orbit Structure Proposal 13093 - Visit 41 - IR Grisms: Wavelength Calibration Monitor 6