Memtrex™ NY Capsules with Hydrophilic Nylon66 Membrane

advertisement
Lenntech
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Memtrex™ NY Capsules
with Hydrophilic Nylon66 Membrane
Features and Benefits
> Utilizes inherently hydrophilic, high-purity Nylon66 membrane
> Innovative serial layer membrane design
> Thermal weld techniques — no adhesives, resins or binders
> Low extractables
> 100 % integrity tested and rinsed for uncompromised reliability
and consistency
Applications
Memtrex NY Capsule Filters have been designed for reliable filtration in
a wide range of applications, including:
> Beverages
> Cosmetics
> Electronics
> Fine and Bulk Chemicals
> Pharmaceuticals
Memtrex NY Capsule Filters (CMNY)
have a unique polyester and
polypropylene construction for
enhanced reliability and usefulness.
Polyester housings and support layers
ensure and maintain capsule integrity,
while a nylon prefilter membrane layer
over a final membrane layer
significantly enhances filter life.
CMNY filters are suitable for a broad
range of applications, meeting
worldwide demand for functionality in
chemical, beverage, and water
processing.
Available Absolute Micron Ratings
0.1, 0.2, 0.45, and 0.65 µm
Materials of Construction
> Filtration Media — Two Layers of Hydrophilic Nylon66
(prefilter layer over final layer)
> Membrane Support Layers — Polyester Microfiber
> Structural Components — Polyester and Polypropylene
Dimensions
Diameter
3.5" (9 cm)
Capsule Size
Effective Filtration Area
Length*
Small
Medium
Large
0.8 ft2 (748 cm2)
3.0 ft2 (2806 cm2)
5.9 (5500 cm2)
3.5 - 5.0" (9 - 13 cm)
7.6 - 9.1" (19 - 23 cm)
11.5 - 13.0" (29 - 33 cm)
*Varies with connection style.
Flow Performance in Clean Water*
Integrity Testing
psid bar
5
(0.34)
4
(0.28)
Micron Rating
Test Pressure
3
(0.21)
0.1 µm
0.2 µm
0.45 µm
0.65 µm
40 psi (2.8 bar)
30 psi (2.1 bar)
20 psi (1.4 bar)
10 psi (0.6 bar)
2
(0.14)
1
(0.07)
0
0
Memtrex NY Small Capsule
0.45 µm
0.65 µm
Service Flow
0
0
gpm
Lpm
Operational Limits
0.2 µm
0.1µm
Pressure Drop
Air diffusion through water saturated membrane is
< 1.8 cc/min per ft2 of Effective Filtration Area
0.2
0.8
0.4
1.5
1.0
3.8
Flow Performance in Clean Water*
psid bar
Additional Information
Memtrex NY Capsule filters may be sanitized with a variety of
commonly used chemical agents; however, acidic solutions
should be avoided. The capsules may be repeatedly autoclaved
(121°C 30 min) for up to 5 cycles.
GE certifies that the materials contained in its Memtrex NY
Capsule filters meet U.S. FDA requirements for food contact
under the applicable regulations in 21 CFR. For further
information, contact the GE Technical Services Department.
Memtrex NY filters meet the test criteria for USP class VI-121°C
Plastics.
GE filter capsules are designed and manufactured for resistance
to a wide range of chemical solutions. Conditions will vary with
each application and users should carefully verify chemical
compatibility. Please contact your GE distributor for more
information.
(0.34)
4
(0.28)
3
(0.21)
2
(0.14)
1
(0.07)
0
0
Memtrex NY Medium Capsule
0.45 µm
0.65 µm
Service Flow
0
0
gpm
Lpm
0.2 µm
0.1µm
Pressure Drop
> Maximum Operating Temperature
110°F (43°C) at <30 psi (2.1 bar) Operating Pressure
5
1
3.8
2
7.6
5
(0.34)
5
18.9
4
(0.28)
3
(0.21)
2
(0.14)
1
(0.07)
0
0
Memtrex NY Large Capsule
0.1 µm
gpm
Lpm
0.2µm
0.45 µm
0.65 µm
Service Flow
0
0
1
3.8
2
7.6
3
11.4
4
15.1
5
18.9
*Data based on 10 inch length filter.
Connections*
L = 1/4" - 1/2" (6.3 - 12.7 mm) hose barb
M = 3/8" (9.5 mm) hose barb
R = 1/4" (6.3 mm) NPT male
W = 1/2" (12.7 mm) NPT male
Y = 1.5" (38.1 mm) sanitary flange
*Choose an inlet and outlet connection
Lenntech
4
15.1
Flow Performance in Clean Water*
psid bar
Ordering Information
Capsule
Size
08 = small (0.8 ft2)
30 = medium (3.0 ft2)
59 = large (5.9 ft2)
3
11.4
*Data based on 10 inch length filter.
Pressure Drop
> Maximum Differential Pressure
60 psi (4.1 bar) @ 70°F (21°C)
Absolute
Micron Rating
CMNY 91 = 0.1 µm
92 = 0.2 µm
94 = 0.45 µm
96 = 0.65 µm
0.8
3.0
*Data based on 10 inch length filter.
> Maximum Operational Pressure
80 psi (5.5 bar) @ 70°F (21°C) in Liquid,
55 psi (3.8 bar) @ 70°F (21°C) in Gas
Type
0.6
2.3
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
/HQQWHFKEY
5RWWHUGDPVHZHJP
++'HOIW
info@lenntech.com
www.lenntech.com
Tel. +31-15-261.09.00
Fax. +31-15-261.62.89
The below GE ‐series cartridge filters are all the models that are potentially possible in all variations.
Please note that not all models are actually produced or on stock and some model numbers and names have become obsolete.
Nevertheless this should help as cross reference table chart for Cuno filters nomenclature.
Memtrex NY Capsule L
CMNY9108L
CMNY9108M
CMNY9108R
CMNY9108W
CMNY9108Y
CMNY9130L
CMNY9130M
CMNY9130R
CMNY9130W
CMNY9130Y
CMNY9159L
CMNY9159M
CMNY9159R
CMNY9159W
CMNY9159Y
CMNY9208L
CMNY9208M
CMNY9208R
CMNY9208W
CMNY9208Y
CMNY9230L
CMNY9230M
CMNY9230R
CMNY9230W
CMNY9230Y
CMNY9259L
CMNY9259M
CMNY9259R
CMNY9259W
CMNY9259Y
Lenntech B.V.
T +31‐15‐261.09.00
F +31‐15‐261.62.89
info@lenntech.com
www.lenntech.com
CMNY9408L
CMNY9408M
CMNY9408R
CMNY9408W
CMNY9408Y
CMNY9430L
CMNY9430M
CMNY9430R
CMNY9430W
CMNY9430Y
CMNY9459L
CMNY9459M
CMNY9459R
CMNY9459W
CMNY9459Y
CMNY9608L
CMNY9608M
CMNY9608R
CMNY9608W
CMNY9608Y
CMNY9630L
CMNY9630M
CMNY9630R
CMNY9630W
CMNY9630Y
CMNY9659L
CMNY9659M
CMNY9659R
CMNY9659W
CMNY9659Y
Rotterdamseweg 402 2629HH Delft
Netherlands
Download