Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 DOWEX™ SBR LC NG (OH) A High Capacity Strong Base Anion Exchange Resin Designed for CVCS and Radwaste Demineralizers in Nuclear Power Systems Product DOWEX™ SBR LC NG (OH) Type Type I strong base anion Matrix Styrene-DVB, gel Guaranteed Sales Specifications Total exchange capacity, min. Water content Bead size distribution† > 1,200 µm, max. (16 mesh) > 420 µm, max. (40 mesh) < 300 µm, max. (50 mesh) Whole uncracked beads, min. Crush strength Average, min. > 200 g/bead, min. Ionic conversion OH95% min. Trace metals, ppm dry resin, max. Na Fe Cu 40 50 10 † % % % % 2 1 0.2 95 g/bead % 350 95 Mg 50 CO35% max. Ca 50 Typical Physical and Chemical Properties Particle density Shipping weight** Recommended Operating Conditions eq/L kgr/ft3 as CaCO3 % OH- form 1.2 26.2 60 max. Cl0.1% max. Al 50 Functional group Quaternary amine Co 30 SO420.1% max. Pb 10 Hg 10 Heavy metals (as Pb) 10 OH- form 1.08 655 41 g/mL g/L lbs/ft3 • Maximum operating temperature 60°C (140°F) • pH range 0 - 14 • Bed depth, min.: Mixed bed Single bed 450 mm (1.5 ft) 800 mm (2.6 ft) For additional particle size information, please refer to Particle Size Distribution Cross Reference Chart (Form No. 177-01775). ** As per the backwashed and settled density of the resin, determined by ASTM D-2187. Page 1 of 2 ™® Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 177-01643-0209 DOWEX™ SBR LC NG (OH) resin is a high quality anion resin with very good mechanical and chemical resistance. It is supplied with a low level of residual chloride and sulfate, each less than 0.1% of exchangeable sites. The resin can be used in a variety of applications, either in single or mixed beds. Typical properties and applications Applications include: • Boric acid recovery • Radwaste decontamination • Reactor coolant treatment 50 liter or 5 cubic feet fiber drums Packaging Figure 1. Pressure Drop Data Temperature = 20° C (68° F) gpm/ft2 0 4 8 12 16 20 24 28 32 36 40 2 6 5 1 4 psi/ft 7 1.5 bar/m Pressure Drop 8 3 0.5 2 1 0 0 10 20 30 40 50 60 m/h Linear Flow Rate 70 80 90 0 100 For other temperatures use: PT = P20°C / (0.026 T°C + 0.48), where P ≡ bar/m PT = P68°F / (0.014 T°F + 0.05), where P ≡ psi/ft Warning: Oxidizing agents such as nitric acid attack organic ion exchange resins under certain conditions. This could lead to anything from slight resin degradation to a violent exothermic reaction (explosion). Before using strong oxidizing agents, consult sources knowledgeable in handling such materials. Notice: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Page 2 of 2 Form No. 177-01643-0209