Industrial RO Series Industrial High Pressure Brackish Water RO Elements

advertisement
Lenntech
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Industrial RO Series
Industrial High Pressure Brackish Water RO Elements
The S-Series proprietary thin-film reverse osmosis
membrane is used in the Industrial RO3 elements. It is
characterized by high sodium chloride rejection and a
smooth, fouling-resistant membrane surface.
The A-Series proprietary thin-film reverse osmosis
membrane is used in the Industrial RO5 and RO6 elements. It is characterized by high sodium chloride rejection and a high permeability.
Industrial RO Brackish Water Elements are used for
concentration of wastewater streams with a high osmotic pressure or a high level of solids. They can also
be used to concentrate diluted acids.
Model
Spacer
mil (mm)
Active area
ft2 (m2)
Outer wrap
Part
number
INDUSTRIAL RO3 4040F35
35 (0.89)
77 (7.1)
Fiberglass
3050577
INDUSTRIAL RO3 4040F50
50 (1.27)
61 (5.7)
Fiberglass
3049999
INDUSTRIAL RO3 8040F35
35 (0.89)
333 (30.9)
Fiberglass
1207451
INDUSTRIAL RO3 8040F50
50 (1.27)
269 (25.0)
Fiberglass
1207450
INDUSTRIAL RO5 4040F35
35 (0.89)
77 (7.1)
Fiberglass
3050576
INDUSTRIAL RO5 8040F35
35 (0.89)
333 (30.9)
Fiberglass
3144696
INDUSTRIAL RO5 8040F50
50 (1.27)
269 (25.0)
Fiberglass
3097294
INDUSTRIAL RO6 4040F35
35 (0.89)
77 (7.1)
Fiberglass
3144699
INDUSTRIAL RO6 8040F35
35 (0.89)
333 (30.9)
Fiberglass
3144697
These elements feature a 35mil or 50mil spacer in a
high pressure compatible element assembly.
Table 1: Element Specification
Membrane
S-Series, Thin-film membrane (TFM*)
A-Series, Thin-film membrane (TFM*)
Model
Average
permeate flow
gpd (m3/day) 1,2
Average NaCl
rejection1,2
Minimum NaCl
rejection1,2
1,900 (7.2)
99.0%
98.5%
INDUSTRIAL RO3 4040F50
1,450 (5.5)
99.0%
98.5%
INDUSTRIAL RO3 8040F35
7,800 (29.5)
99.0%
98.5%
INDUSTRIAL RO3 8040F50
6,500 (24.6)
99.0%
98.5%
INDUSTRIAL RO5 4040F35
1,950 (7.4)
99.5%
99.0%
INDUSTRIAL RO5 8040F35
9,100 (34.4)
99.5%
99.0%
INDUSTRIAL RO5 8040F50
7,400 (28.0)
99.5%
99.0%
INDUSTRIAL RO6 4040F35
3,250 (12.3)
99.0%
98.0%
INDUSTRIAL RO6 8040F35
15,400 (58.3)
99.0%
98.0%
INDUSTRIAL RO3 4040F35
salt rejection after 24h operation. Individual flow rate may vary ±25%.
2 Testing conditions: 2,000ppm NaCl solution at 425psi (2,930kPa) operating pressure for RO3 vs 225psi (1,550kPa) for RO5 and RO6, 77°F, pH 6.5 and 15% recovery.
Figure 1a: Element Dimensions Diagram (Female) – 8040
1 Average
Figure 1b: Element Dimensions Diagram (Male) – 4040
* Trademark of General Electric Company; may be registered in one or more countries.
©2015, General Electric Company. All rights reserved.
Apr-15
Table 2: Dimensions and Weight
Dimensions, inches (cm)
Model1
Boxed
A
B2
C3
Weight
lbs (kg)
4040F
40.0
(101.6)
0.75
(1.90) OD
3.9
(9.9)
9
(4.1)
8040F
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
29
(13.2)
1 These
elements are dried then bagged before shipping.
diameter unless specified OD (outside diameter).
3 The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity
2 Internal
Table 3: Operating and CIP Parameters
Typical Operating Flux
5 - 20 GFD (8 – 34 LMH)
Maximum Operating Pressure
1,200psi (8,276kPa) if T<77°F (25°C)
580psi (4,000kPa) if T>77°F (25°C)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Optimum rejection: 5.5-7.0,
Continuous operation: 2.0-10.0,
Clean-In-Place (CIP): 1.0-11.5
Maximum Pressure Drop
Over an element: 15psi (103kPa)
Per housing: 60psi (414kPa)
Chlorine Tolerance
500+ ppm hours,
dechlorination recommended
Feedwater
NTU < 1
SDI < 5
Lenntech
Page 2
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Download