RESIDENTIAL CONTROL VALVES Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 255 Control Valves Pentair Water ® offers a full range of Autotrol® Control Valves to meet all residential water conditioning applications. Logix™ Series 740 Time Clock 742 Time Clock • Simple, economic electronic time clock (chronometric) • 7- or 99-day regeneration setting • High efficiency regeneration sequence • 12-volt operation • Filter or conditioner setting in one control • Operates 255, 263, 268 with one controller Same features as the 740 Time Clock, plus: • Fully programmable cycle times • Salt setting in 1-pound increments • Optional no-salt detector • Operates 255, 263, 268, 278, and Magnum® IT with one controller 760 Demand 762 Demand 764 Demand • Simple, economic electronic demand (volumetric) • Calendar override • 12-volt operation • 28-day variable reserve • High efficiency regeneration sequence • Automatic capacity calculations • Operates 255, 263, 268 with one controller Same features as the 760, plus: • Fully programmable cycle times • Salt setting in 1-pound increments • Optional no-salt detector • Operates 255, 263, 268, 278, and Magnum IT with one controller Same features as the 762, plus: • Multi-tank applications (twin alternating, multitank parallel) • Control lockout • Remote regeneration RESIDENTIAL CONTROL VALVES 255 Control Valves Specifications Electrical Controller Operating Voltage 12 Volt – AC (Requires use of Pentair Water ®-supplied transformer) Input Supply Frequency 50 or 60 Hz (Controller configuration dependent) Motor Input Voltage 12 Volt – AC Controller System Power Consumption 3 Watts average Transformer – All Controllers All Controllers require the use of a Pentair Water-supplied transformer. Transformer Output Voltage 12 Volt – AC 400mA Transformer Input Options 115 Volt – AC 50/60 Hz; 230 Volt – AC 50/60 Hz; 100 Volt – AC 50/60 Hz Transformer Plug Options Indoor North American Plug Taiwan/Korea Plug Outdoor North American (UL Listed for outdoor use) Australian Plug Mainland Europe Plug Japanese Plug United Kingdom Plug Additional transformers may be available – call for more information. Design Specifications/Ratings Valve Body Glass-filled thermoplastic – NSF Listed material Rubber Components Compounded for cold water – NSF Listed material Valve Materials CertificationWQA Gold Seal Certified to ORD 0902 and NSF/ANSI 44 Rated component for material safety Weight (Valve with Control) 4 Ibs (1.8 kg) Recommended Operating Pressure Canada 20 - 120 psi (1.38 - 8.27 bar) 20 - 100 psi (1.38 - 6.89 bar) Hydrostatic Test Pressure Water Temperature Ambient Temperature* 300 psi (20.69 bar) 35° - 100°F (2° - 38°C) 35° - 120°F (2° - 48.9°C) *Recommend use of outdoor cover for direct sunlight applications. Options Turbine for Demand Units Standard manifold, 1-inch Autotrol® Turbine Bypass ValveThermoplastic, 1-inch flow path, 1/2-inch (13mm) NPT male, drain Bypass Inlet-Outlet Fitting Kits: Copper, Sweat Tube Adapter 1-inch or 3/4-inch (25 mm or 19 mm) CPVC, Solvent Weld Tube Adapter 1-inch or 3/4-inch (25 mm or 19 mm) Plastic NPT or BSPT Pipe Adapter 1-inch male or 3/4-inch male (25 mm or 19 mm) Stainless steel NPT or BSPT Pipe Adapter 1-inch male or 3/4-inch male (25 mm or 19 mm) Brine Refill Controls .33 gpm (1.25 Lpm) fixed .14 gpm (.53 Lpm) fixed – optional for small tank applications Compatible with Regenerants/Chemicals Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite†, sodium hydroxide†, hydrochloric acid†, chlorine†† and chloramines†† † See owners manual for specific concentrations. †† Valve for use on potable water supply. A J K Dimensions Valve Connections Tank Thread 2-1/2-inches – 8, male Brine Line 1-inch NPT or BSPT, female 3/4-inch NPT or BSPT, female Distributor Tube 3/4-inch NPT or BSPT, male (thermoplastic) (diameter) J 1/2-inch NPT or BSPT, male (thermoplastic) Distributor Tube K 1/2-inch (manifold dependent) (length) Inlet/Outlet Manifold (brass or thermoplastic) Drain Line A 1/4-inch or 3/8-inch NPT, male; air check built into valve 1.050 inches (27 mm) or 13/16-inch (20.6 mm) 1-1/8 ± 1/8 inches (29 mm ± 3 mm) above top of tank H B Outline Dimensions I C A D J G K H B Units A B C D E F inches cm 14.9 37.8 6.6 16.8 8.2 20.8 8.4 21.3 4.2 10.7 4.0 10.2 I E C G 5.7 14.5 D F H I J K 3.1 7.9 5.1 13.0 1.5 3.8 1.5 3.8 G H Performance B I C E Flow Rates (Valve Only) Service @ 15 psi (1.03 bar) drop Backwash @ 25 psi (1.72 bar) drop Service Backwash F 15.5 gpm (3.52 m3/h) 6.0 gpm (1.36 m3/h) Cv D = 3.99 (Kv = 3.4) G = 1.20 (Kv = 1.0) Cv Note: Tested with a 3/4-inch brass manifold E FFlow Rate Characteristics Logix 764 Performance Flow Rate (m3/hr) 0 0.5 0.9 1.4 1.8 2.3 2.7 3.2 1.10 Backwash Number* Flow Rate (gpm) Flow Rate (lpm) 1.00 7 1.3 4.9 0.90 8 1.7 6.4 9 2.2 8.3 10 2.7 10.2 12 3.9 14.76 13 4.5 17.0 14 5.3 20.0 3.6 = 1.2 0 16 – Cv 0.80 3. = 5B AC K 6 5 25 25 4 0.60 0.50 – 8 0.70 Cv WA SH 10 99 FLO W 12 2 E IC RV E S W O FL 0.40 0.30 0.20 LWR 5236 BW LWR 4630 SVC 0 0 2 4 6 8 10 12 14 Flow Rate in Gallons Per Minute 16 0.10 0.00 Pressure Drop (Bar) Pressure Drop in PSI 14 Backwash Flow Control Table *Backwash flow controls sized for 5.0 gpm/ft2. Injector* Performance Logix™ Series Controllers Injector “J” Blue) (Light Blue) Injector “J” (Light For 10-inch For 10-inch Tanks Tanks Injector “F” (Peach) Injector “F” (Peach) For 7-inch For 7-inch Tanks Tanks 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 bar 3 5 6 6 7.5 7.5 0.10 0.05 0.05 0.00 0.00 0.08 0.08 0.07 0.07 0.06 0.06 0.04 0.03 0.03 0.02 0.02 0.01 0.01 0.00 4060 TOTAL TOTAL 6080 80100 PSI PSI BRINE DRAW BRINE DRAW 100 120 0.05 0.04 LWR6057 LWR6057 2040 20 m / hr 0.05 bar 3 m / hr 0.00 0.80 0.80 0.60 0.60 RINSE TOTAL TOTAL bar 5 6 6 7.5 7.5 Gallons per Minute 0.30 0.20 0.30 0.20 0.10 0.10 0.11 0.10 0.10 0.09 0.09 0.08 0.08 0.07 0.07 0.06 0.06 0.05 0.05 0.04 0.04 0.03 0.03 0.02 0.02 0.01 0.01 0.00 2040 20 m3/ hr 0.11 LWR6057 LWR6057 0.00 0.00 m3/ hr 4060 TOTAL TOTAL 6080 PSI 80100 PSI BRINE DRAW BRINE DRAW 100 120 RINSE 0.00 bar 1.20 1.00 1.00 0.80 0.80 0.60 0.60 0.40 0.40 0.20 0.20 RINSE 0.50 0.50 0.40 0.40 0.30 0.30 0.20 0.20 0.10 3.55 bar 5 6 6 7.5 7.5 0.10 0.00 0.00 20 40 20 TOTAL TOTAL 3 m /hr 0.16 0.16 0.14 0.14 0.12 0.12 0.10 0.10 0.08 0.08 0.06 0.06 0.04 0.04 0.00 80100 PSI BRINE DRAW BRINE DRAW 0.14 0.12 0.12 0.10 0.10 0.08 0.08 0.06 0.06 0.04 0.04 0.02 0.02 100 120 0.00 120 PSI RINSE RINSE 100 120 RINSE 120 6 7.5 7.5 m3/hr m3/hr 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0.00 80100 PSI BRINE DRAW BRINE DRAW 0.02 0.00 2 3.5 2 1.50 1.50 1.25 1.25 1.00 1.00 0.75 0.75 0.50 0.50 0.25 0.25 3.55 bar 100 120 RINSE bar 5 6 0.00 120 RINSE 20 7.5 m3/hr 6 7.5 0.30 0.20 0.20 0.10 0.10 0.00 20 40 4060 6080 TOTAL TOTAL 80100 100 120 m3/hr 0.30 LWR6164 LWR6164 0.00 0.00 PSI RINSE bar 5 6 6080 PSI 3 m /hr 0.02 6080 PSI 0.16 0.14 Injector “L” (Orange) Injector “L” (Orange) 13and 14-inch For 13-For and 14-inch Tanks Tanks LWR6151 LWR6151 4060 3.55 4060 TOTAL TOTAL Gallons per Minute 0.60 2 3.5 0.16 LWR6151 LWR6151 2040 20 Gallons per Minute 0.60 Gallons per Minute Gallons per Minute bar 2 0.70 80100 0.00 0.00 120 Injector “H” Purple) (Light Purple) Injector “H” (Light For 9-inch For 9-inch Tanks Tanks 0.70 6080 BRINE DRAW BRINE DRAW 2 3.5 2 1.20 Gallons per Minute 3.55 m /hr 0.18 0.00 4060 3 m /hr 0.18 Injector “K” (Pink) Injector “K” (Pink) For 12-inch For 12-inch Tanks Tanks 0.40 0.40 Gallons per Minute 2 3.5 7.5 LWR6151 LWR6151 2040 20 Gallons per Minute bar 2 0.50 3 6 7.5 0.00 0.00 PSI RINSE bar 5 6 0.20 0.20 Injector “G” (Tan) Injector “G” (Tan) For 8-inch For 8-inch Tanks Tanks 0.50 3.55 0.40 0.40 120 2 3.5 2 Gallons per Minute 0.35 3.55 Gallons per Minute 0.35 Gallons per Minute Gallons per Minute bar 2 3.5 2 0.00 120 PSI BRINE DRAW BRINE DRAW RINSE RINSE *New injectors for high-efficiency regeneration sequence are standard with Logix Controllers. NOTE: Actual injector performance is dependent on the resin used, tank geometry, elevated drain, etc. This injector data was taken using an empty tank (no resin). Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289