Turbine Protection System (TPS) Standard Solutions Application: Westinghouse GE Siemens Allis Chalmers MHI Delaval ABB Alstom Fuji Toshiba The Turbine Protection System (TPS) is an electrical control and field sensor modernization package designed to replace the existing legacy protection system on steam turbines. The TPS can enhance turbine availability with features of 2-out-of-3 voting for pressure and speed sensors. Different option combinations can be incorporated within the core design providing a customized solution built around the specific units requirements. The Redundant Testable Trip Device (below) combines vacuum, thrust, low bearing oil pressure, and trip block configuration in one freestanding unit. The TPS system is available for high pressure hydraulic systems and low pressure hydraulic systems. The TPS system can be used in both power and industrial applications. High Pressure Redundant Testable Trip Device SPPA-R3000 Turbine Protection System Energy Instrumentation, Controls & Electrical Potential Benefits Fits within maintenance budget Reduce downtime – on-line testing Reduce human error – automated testing Extend service life – minimize stress during testing Improve turbine availability – simplified on-line maintenance Eliminate single point failures Built-in first out trip indication Features 2 out of 3 voting standard (other options available) 5 millisecond scan time on overspeed protection Automated test routines On line diagnostics Pre-configured operating modes for system failures Built in user interface Built in DCS interface Communicates with any DCS Proven reliable Siemens PLC Upgradeable modular packages 24-hour customer support Siemens world class service Turbine Mechanical Conversion Available Option The standard conversion package involves a new trip system, where as the existing trip block and overspeed bolt are eliminated and replaced with a 2 -out-of-3 voting architecture. ■ An upgraded user interface with color display and trending capability The panel contains new triplicated field devices for the parameters monitored. Each device within the panel is on-line testable. Field transmitters may be calibrated on-line. Most components are on-line repairable / replaceable as well. ■ Electronic Turbine Thrust proximitors to replace legacy mechanical systems ■ EHC interposing relays to allow for ■ Plant trips to be included in the first -out trip display ■ Zero speed detection ■ Mechanical only package available Low pressure TPS can be easily and cost effectively upgraded to high pressure TPS in the future if the plant changes from MHC to EHC after a low pressure TPS has been installed. Process Configurations A true 2-out-of-3 voting system, the standard TPS electronics packages consist of three processors monitoring all trip inputs. Each processor independently decides to issue a trip based on its set of inputs. All three of the processors share their input and output status signals for alarming and testing functions. Optional processor configurations include: ■ Fault tolerant redundant processors ■ Simplex processor for cost sensitive applications Published by and Copyright 2008: Siemens Energy, Inc. Instrumentation, Controls & Electrical 1345 Ridgeland Parkway, Suite 116 Alpharetta, GA 30004 USA Tel: 678.256.1500 Fax: 678.256.1553 siemens.com/energy/controls All rights reserved. Subject to change without prior notice. Printed on paper treated with chlorinefree bleach. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should there-fore be specified in the contract. Operator Monitor (Optional) Display High Volume Trip Block Assembly for Low or High Pressure System