Achieve Optimal Results In Analytical Chemistry Sample Preparation and Mobile Phase Filtration www.pall.com/lab

advertisement
www.pall.com/lab
Achieve Optimal Results
In Analytical Chemistry Sample Preparation
and Mobile Phase Filtration
Proven Performance for Confident Results
Whether you are processing single samples or thousands
of samples at a time, you can count on our unfailing quality.
Over thirty years ago, Pall Life Sciences revolutionized
sample preparation for analytical chemists with the
development of the Acrodisc® syringe filter. Today,
we partner with scientists around the world to develop
distinctive filtration and separation products for a wide
range of processing volumes.
We are constantly looking for new ways to expand our
product offering to meet your needs and ease your
application challenges. Our product innovations are the
result of understanding your applications and valuing
the amazing contributions your work can make to the
quality of all our lives.
Whether you are pursuing goals in life science,
pharmaceutical methods, research and development,
quality control, or specialty environmental applications,
we commit to not only deliver a product that works,
but to look beyond what simply works and deliver
a product that truly makes a difference.
2
Focused on producing
products that give you better
results for high throughput
sample preparation.
Pall Life Sciences is one of the few companies to offer
a variety of products made from the same materials
of construction, allowing for single- or multiple-sample
processing of your techniques. We bring together
membranes with superior performance, outstanding
housing materials, and devices designed to maximize
processing accuracy and speed.
Single-Sample Processing
Select the device configuration most appropriate for your
Acrodisc PSF Syringe Filters
(Automated Applications)
application, then select one of our patented membranes
with the characteristics you need most... and see what a
difference Pall Life Sciences can make.
Multi-Sample Processing
AcroPrep™ Advance and AcroPrep Filter Plates
See pages 6-7 for more information.
Perfect for smaller sample sizes in combinatorial
chemistry cleavage applications
Makes concentration and final filtration for SPE faster
Great for numerous samples with HPLC sample
preparation/clarification
Perform quick and accurate metabolic studies
AcroPrep 24 Filtration System
See pages 8-9 for more information.
Designed to work specifically with Waters
Alliance◆ HPLC system
Improves productivity in methods development
See pages 10-12 for more information.
Acrodisc PSF syringe filters are the
only syringe filters to receive SOTAX◆
and Zymark◆ Automation Certified guarantees
Smooth operation and worry-free performance
24 hours a day
For unattended processing of large numbers
of samples with robotic workstations
Traditional Acrodisc Syringe Filters
(Manual Applications)
See pages 13-15 for more information.
Broad line of syringe filters for all your HPLC/UHPLC needs
Wide range of device sizes for minimal sample hold-up
and easy dispensing into autosampler vials
GHP Nanosep® MF Centrifugal Devices
See page 16 for more information.
For applications requiring maximum filtrate recovery from
limited sample volumes
Consistent, reproducible results for quality control
Speeds up sample clarification
www.pall.com/lab
3
Filter Media Selection is as Easy as 1-2-3
Pall’s broad selection of membrane chemistries
ensures optimal performance for your application.
Pall’s superior media separation technology ensures
HPLC Certified for Low Extractables
protection of your analytical instruments and supports the
Pall Life Sciences HPLC certification ensures that analytical
integrity of your analytical results. Pall’s capabilities ensure:
results will not be compromised by extractable filter materials.
Accurate pore size ratings for better chromatography
and instrument/column protection (see page 11)
Uniform membrane materials (lot-to-lot) to provide
consistent analytical results
Low extractable materials for less chromatographic
interference
Materials of construction selected specifically for analytical
analysis with lower extractables and lower API adsorption
1
Consider Chemical
Compatibility
Chemical compatibility is defined as the ability of a filter
material to resist select chemicals so that the pore structure
is not adversely affected by chemical exposure, and the
filter material does not shed particles or fibers to add
extractables. For example, nylon is not recommended
for strong acidic solutions due to incompatibility. The
chemical compatibility chart on page 19 will help you
make the right choice.
Temperature, time, concentration, applied pressure,
and length of exposure also affect compatibility.
Acrodisc® and Acrodisc PSF syringe filters are randomly
chosen and tested for compatibility with common solvents
using UV detection. Does not include HT Tuffryn®, Versapor®,
or Supor® membrane versions.
IC Certified for Low Levels of Inorganic Extractables
Pall Life Sciences certified Ion Chromatography (IC) Acrodisc
and Acrodisc PSF syringe filters have been tested using
a highly sensitive IC protocol to monitor ionic extractables.
Actual background levels of filter extractables are typically
less than 20 ppb for chloride, 6 ppb for nitrate, 1 ppb for
phosphate, and 10 ppb for sulfate.
Binding
Membranes may chemically interact with the sample through
electrostatic, ionic, covalent, hydrogen bonding, or other
interactions. Binding can be a desirable or undesirable
characteristic depending on the requirements of the
application. Choose GHP membrane for applications
requiring low binding.
Reference Material
Extractable Materials
Also available online in our Literature Library
Contaminants that elute from the filter media are best
at www.pall.com/lab.
prevented by the membrane manufacturer. Pall Life
Sciences specifically selects the highest grade of materials
and performs rigorous extraction methods on our
membrane products to reduce the occurrence of undesired
artifacts. Choosing membranes that are compatible
with your fluids and experimental conditions will reduce
or eliminate extractables.
4
To verify low levels of extractables, samples of HPLC
Technical Guide, Use of Acrodisc Syringe Filters for
Analytical Sample Preparation; Including HPLC and
Dissolution Testing (PN 33454)
Non-Aggressive Organic
Aggressive Organic
General Aqueous
Proteinaceous
Media Selection
GH Polypro (GHP) Membrane – GHP is an all-purpose,
hydrophilic membrane for aqueous, acidic, basic,
non-aggressive organic, and aggressive organic solutions.
GHP membrane offers low protein binding and low levels
of UV-absorbing extractables.
PTFE Membrane – Exceptional chemical and
temperature compatibility make this membrane ideal for
harsh chemicals that destroy other membrane materials.
Nylon Membrane – This versatile filter for both aqueous
and solvent-based sample filtration exhibits excellent
chemical compatibility with esters, bases, and alcohols.
Not recommended for acids > 1 N or halogenated solvents.
Volume to
be Filtered
Filter Type
Typical Hold-Up
Volume
< 500 µL
Nanosep® MF Device
< 2 µL
< 900 µL
AcroPrep™ 96
1 mL Filter Plate
< 18 µL/well
< 2 mL
4 mm Acrodisc Syringe Filter
< 10 µL
< 2 mL
AcroPrep 24 Filter Plate
< 50 µL/well
< 10 mL
13 mm Acrodisc Syringe
Filter (Minispike)
< 14 µL
< 10 mL
13 mm Acrodisc Syringe Filter
< 30 µL
< 100 mL
25 mm Acrodisc Syringe Filter
< 150 µL
< 125 mL
25 mm Acrodisc PSF
Syringe Filter
< 200 µL
**
PVDF Membrane – Compatible with many organic and
non-organic solvents making it ideal for a wide range
of applications. Not recommended for acetone, DMF,
DMSO, or bases > 6 N.
Glass Fiber Media – Maximize throughput for extremely
particulate-laden samples.
Supor (PES) Membrane for Ion Chromatography (IC) –
Optimized to provide the most consistent results when
analyzing ionic species, even for the most sensitive analyses.
Certified for low levels of ionic extractables.
Hydrophilic Membranes for General Aqueous Samples –
Widely used in dissolution testing, choose from a variety
of pore sizes and membrane types for prefiltration and
clarification including Supor, HT Tuffryn‚ and
Versapor membranes.
3
Choose the Right
Pore Size
Pore size is best selected by considering the instrumentation
used for analysis. UV/V spectrophotometers may only
require 1 µm filtration; HPLC analysis may require 0.45 µm
filtration; and UHPLC will require 0.2 µm filtration due to the
size of the column packing, beads, and internal frits. The
Recommended
Suitable
Not Recommended
**Dependent on protein type and concentration.
filter material’s pore size is determined by the diameter of
the smallest particle that is to be retained with a defined,
2
Consider Effective
Filtration Area (EFA)
The particulate contained within a fluid affects the life of a
filter. As particles are removed from a filter, they block pores
and reduce the useable portion of the filter. Fluids with
particulate loads will plug a filter more quickly than “clean”
fluids. Increasing the EFA can lengthen the life of a filter.
The following table outlines general guidelines for the most
appropriate filter size for different volumes of liquid.
high degree of efficiency.
For standard liquid chromatography systems using columns
with 5 µm or larger packings, the filtration industry standard
is 0.45 µm for syringe filters and mobile phase membranes.
For columns with packings smaller than 5 µm, UHPLC,
microbore columns, or when concerned about microbial
growth, a 0.2 µm filter is recommended.
To clarify samples or when processing difficult-to-filter
solutions, 1 to 5 µm pore sizes or glass fiber filters are
suggested. Prefilters generally precede smaller pore size
final filters and allow the user to process larger fluid volumes
before the filter plugs.
www.pall.com/lab
5
AcroPrep ™ Advance and AcroPrep
Filter Plates for Sample Clean-Up
in Analytical Applications
As samples get smaller and more numerous, you need
Serialized Barcode
new methods for high throughput sample preparation.
Serialized barcode label allows for the use of automated
We are ready to help with high throughput screening,
tracking systems.
combinatorial chemistry, and sample clean-up in analytical
or solid-phase extraction applications.
Performance
Observed Crosstalk in AcroPrep Filter Plate = 0%
Counts Per Second (CPS)
1.E+07
1.E+06
1.E+05
5.2 X 104
1.E+04
1.E+03
1.E+02
0
50
100
150
200
Well Number
Fluorescein dye (green) (200 µL of a 2 µg/mL H2O stock) was added
to wells of AcroPrep plates with GHP membrane (5 plates total) in a
checkerboard pattern. Alternate wells were filled with 200 µL of water.
The fluid was evacuated from each filter plate using vacuum filtration
at 30 cm Hg (12 in. Hg) for 15 seconds and the filter plate read in
a PerkinElmer, Wallac VICTOR◆ 1420 Multilabel Counter. Wells filled
with water (orange), which show a CPS reading above the dashed
line (5.2 x 104 CPS, which is = “Average” Background + 5% Signal)
in the graph, constitute a crosstalk event.
Special Features
Worry-Free Performance
The robotic-friendly design has a rigid, single-piece
construction, designed in accordance with American
National Standards Institute (ANSI) specifications.
Applications by Membrane Type
GHP Membrane
HPLC sample prep and clarification
Metabolic studies
No Crosstalk
Membranes are sealed in separate wells using a proprietary
sealing technology and extended flow directors eliminate
crosstalk of filtrate. Our proprietary design also eliminates
weeping for aqueous solutions and drastically reduces
weeping for organic solutions.
Chemically Resistant Plate Assembly
Constructed from chemically-resistant, biologically-inert
polypropylene.
6
Applications that use harsh organics
Combinatorial chemistry library screens
Solvent-based applications
PTFE Membrane
Molecular synthesis
Drug synthesis reactions
Glass Fiber Media
Gross fractionation
Cell-based assays
Glass Fiber Over Supor® Membrane
Clarification of cell lysates and tissue homogenates
Preparation of proteinaceous solutions
Applications that require prefiltration
Mustang® Membrane
Protein fractionation
Protein capture
Ordering Information
Antibody purification
AcroPrep 96-Well Filter Plates (Natural)
Vacuum Manifold Designed to
Perfectly Fit AcroPrep Filter Plates
The multi-well plate vacuum
Part Number
5052
5054
5065
Description
1 mL, 0.2 µm, GHP membrane
1 mL, 0.45 µm, GHP membrane
1 mL, 1.2 µm, Supor membrane, valve mat
manifold is an anodized
AcroPrep Advance 96-Well Filter Plates (Natural)
aluminum manifold that has
Part Number
8047
8048
8147
8148
8131
8175
been designed and optimized
for vacuum filtration of Pall’s
multi-well filter plates.
For more information on our full line of 96and 384-well filter plates, visit www.pall.com/lab.
Reference Material
8171
8172
8247
Description
350 µL, 0.2 µm PTFE membrane
350 µL, 0.45 µm PTFE membrane
1 mL, 0.2 µm PTFE membrane
1 mL, 0.45 µm PTFE membrane
1 mL, 1.0 µm, glass fiber media
1 mL, 3.0 µm glass fiber media/0.2 µm
Supor membrane
1 mL, 0.8 µm, Mustang Q membrane
1 mL, 0.8 µm, Mustang S membrane
2 mL, 0.2 µm PTFE membrane
Also available online in our Literature Library
Accessories and Replacement Parts
at www.pall.com/lab.
Part Number
5017
5225
5230
5231
8001
Product Data, AcroPrep Advance Filter Plates, PN 33577
Product Data, AcroPrep 96 Filter Plates
Scientific and Technical Report, Automated Purification
of Combinatorial Libraries Using AcroPrep 96
Filter Plate with GHP Membrane, PN 33245
Description
Multi-well plate vacuum manifold
Adapter collar for centrifugation
Cap mat for incubation
AcroPrep multi-well plate lids
AcroPrep Advance multi-well plate lids
Pkg
5/pkg
5/pkg
5/pkg
Pkg
10/pkg
10/pkg
5/pkg
5/pkg
5/pkg
5/pkg
5/pkg
5/pkg
5/pkg
Pkg
1/pkg
2/pkg
5/pkg
10/pkg
10/pkg
www.pall.com/lab
7
AcroPrep ™ 24 Filtration System Simultaneously
Filters Up to 24 Samples in Seconds
This system eliminates the time consuming one-at-a-time
Special Features
syringe filter process. The AcroPrep 24 system filters
Save Time and Materials
directly into vials loaded in a Waters Alliance◆ 2690 sample
Save up to 20 minutes of labor time per carousel over the
carousel.* AcroPrep 24 filter plates are available with the
conventional syringe filter technique.
same HPLC certified membranes as our trusted Acrodisc®
PSF syringe filters, eliminating the need to validate the
AcroPrep 24 filter plates.
Syringe Filter Technique
24 disposable syringes
+ 24 syringe filters
25 minutes
AcroPrep 24 Filtration System
24 disposable pipette tips
+ 1 AcroPrep 24 filter plate
5 minutes
Easy to Use
No need to use cumbersome, individually wrapped
disposable syringes. Use disposable pipette tips which are
less costly, easier to use, and require less bench space.
Compatible With All 12 x 32 mm Vial Systems
Can be used with any HPLC autosampler that houses
12 x 32 mm vials. Simply transfer your filtered samples from
the Waters Alliance sample carousel to save time and labor.
No Cross-Contamination
Each 1.9 mL well is individually sealed, ensuring your
sample will accurately dispense into the Waters Alliance
sample carousel with no cross-contamination or splashing.
HPLC Certified
Ensures that analytical results will not be compromised
by extractable filter materials.
Simple Validation
Materials of construction are identical to Pall’s Acrodisc
PSF syringe filters. If you are currently using Acrodisc PSF
syringe filters, this will reduce the requirements for validation
of the AcroPrep 24 filter plates.
*The Water’s Alliance 2690 sample carousel kit (PN WAT270328)
can be ordered directly from your local Waters sales office or
contact Waters Corporation at 800-252-4752 (in the USA)
or 508-478-2000.
8
Applications
Methods development
Research and development
Quality control
Combinatorial chemistry synthesis
Reference Material
Also available online in our Literature Library
at www.pall.com/lab.
Product Data, AcroPrep 24 Filtration System, PN 33241
Ordering Information
AcroPrep 24 Filter Plates
Part Number
186000159
186000155
186000158
600000158
186000154P
186000154
186000156
186000157
Description
0.2 µm, Nylon membrane
0.45 µm, Nylon membrane
0.2 µm, GHP membrane
0.45 µm, GHP membrane
0.45 µm, GxF/GHP membrane
0.45 µm, GHP membrane
0.45 µm, PTFE membrane
0.45 µm, PVDF membrane
Pkg
10/pkg
10/pkg
10/pkg
2/pkg
10/pkg
10/pkg
10/pkg
10/pkg
AcroPrep 24 Filtration System Manifold
Part Number
289000159
Description
Filtration manifold
Pkg
1/pkg
Spare Parts and Accessories
Part Number
700000231
700000232
700000233
700000234
Description
Glass housing for filtration manifold
O-ring kit
Rubber feet
Manifold alignment post
Pkg
1/pkg
3/pkg
3/pkg
3/pkg
www.pall.com/lab
9
Three Powerful HPLC Sample Prep Benefits
in One Acrodisc ® PSF Syringe Filter
1
Automation Certification for
Smooth Operation and Worry-Free
Performance 24 Hours a Day
Pall Life Sciences has specifically designed
and certified our Acrodisc PSF syringe filters
to be fully compatible and reliable for use
with automated equipment. The following
special features make our syringe filters
reliable for worry-free performance
24 hours a day:
Smooth Filter-to-Filter Release
The Acrodisc PSF syringe filter has been designed
so the filters cannot be forced too tightly together
AND
or to the automation components, allowing for a
AUTOMATION
CERTIFIED
®
smooth release, while still meeting ANSI/ISO
filter luer standards.
Consistent Turret Advancement
The filter’s quick-releasing luers
Smooth filter-to-filter release
separate easily, and the slightly rounded upper
Consistent turret advancement
shoulder allows the filter to consistently slide under
Exceptional housing strength
the wedge. This results in trouble-free separation from the
Strict “outside filter geometry”
filter stack and smooth filter advancement along the
Acrodisc PSF syringe filters from Pall Life Sciences are
the only syringe filters to receive the
SOTAX◆
and
workstation’s track.
Zymark◆
Automation Certified guarantee. This certification is only
granted to syringe filters that meet the stringent
requirements for automated dispensing and robotic
handling. Pall works in close partnership with the SOTAX
AG manufacturing and engineering teams to ensure proper
fit, function, and compatibility with SOTAX and Zymark
workstations.
Exceptional Housing Strength
The specially designed support ribbing,
thick device walls, and proprietary housing
weld ensure a robust seal, as well as a
filter housing that can withstand excessive
force both internally and externally.
Strict "Outside Filter Geometry"
Pall’s Acrodisc PSF syringe
filters work best with SOTAX
AG’s Zymark TPW◆, APW◆,
and MultiDose◆ workstations.
Pall’s standard Acrodisc
syringe filters work best with
SOTAX’s AT-70 SMART◆, CTS,
and FS workstations. These
robotic workstations are all
uniquely designed to work
with SOTAX and Zymark
Automation Certified filters
for proper operation.
10
Special Features
Strict dimensional specifications in height
and width ensure proper alignment and
smooth operation.
2
3
Best Protection for HPLC
Columns—Extending Column
Life as Much as 46 Times
GxF Multi-Layered Prefilter
Provides Maximum Throughput
The Acrodisc PSF syringe filter has a serial glass fiber
Plugging is the most frequently encountered cause of High
prefilter to allow for two to four times the throughput and
Performance Liquid Chromatography (HPLC) column failure
faster flow rates than standard glass fiber prefilter devices.
by analytical chemists and analysts. Injection of samples
The multi-layered prefilter traps particulate rated from
containing particulates will eventually block the column
> 40 to 1 µm.
inlet, cause high column back-pressure, and shorten the
normal lifetime of the column. Operations of pump
components, injectors, and detectors are expected to
be less troublesome when fluids are filtered. Pall Acrodisc
Special rib design and
proprietary weld ensure
robust seal under high
operating pressures.
Ample headspace for
filter cake to build for
optimal throughput.
PSF syringe filters with GHP (hydrophilic polypropylene)
membrane offer the most efficient removal of particulate
and prolong the life of HPLC system components.
Effects of Filters on HPLC Column Life
Free-floating
prefilter prevents
premature clogging.
Column Back-Pressure, psig
4000
Unfiltered
Competitor Filters
Competitor Filters
Pall Acrodisc
PSF Filters
3500
3000
2500
2000
Multi-layered prefilter traps
heterogeneous particulate
throughout the matrix and on
the surface, extending filter life.
1500
Heat sealed membrane
ensures particulate
retention with no chance
of breakthrough.
1000
Applications
500
0
0
200
400
600
Number of Injections
800
1000
Among 0.45 µm rated syringe filters from three manufacturers,
the Pall Acrodisc PSF syringe filters with GHP membrane have
the highest average retention efficiency (94.9%) of 0.45 µm
latex spheres, as well as greater lot-to-lot consistency. The data
demonstrates “equivalent” filters from various manufacturers
with the same removal rating differ in capabilities. Using
Acrodisc PSF syringe filters with GHP membrane extended
the column life 46 times with no significant increase in column
back-pressure. For a full technical report, order “Use of
Acrodisc Syringe Filters for Analytical Sample Preparation;
Including HPLC and Dissolution Testing Application Guide,”
PN 33454; or visit www.pall.com/lab.
Sample preparation for HPLC, UHPLC, IC, and GC
Dissolution testing
Automated workstations such as SOTAX and Zymark
Clarifying samples heavily laden with particulates
– Environmental groundwater
– Pulp and paper
– Food and beverage
Reference Material
Also available online in our Literature Library
at www.pall.com/lab.
Product Data, Acrodisc PSF Syringe Filter
Technical Guide, Use of Acrodisc Syringe Filters for
Analytical Sample Preparation; Including HPLC and
Dissolution Testing, PN 33454
www.pall.com/lab
11
Ordering Information
Acrodisc® PSF Syringe Filters With GHP Membrane, 25 mm
Acrodisc PSF Syringe Filters With PVDF Membrane, 25 mm
Part Number
AP-4364
AP-4564
AP-4566
AP-4357
AP-4560
AP-4562
AP-4305
AP-4307
AP-4306
AP-4557
AP-4559
AP-4558
Part Number
AP-4795
AP-4796
AP-4797
AP-4519
AP-4408
AP-4500
AP-4792
AP-4793
AP-4794
AP-4309
AP-4310
AP-4308
Description
0.2 µm, AutoPack™ tubes
0.2 µm
0.2 µm
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
GxF/0.2 µm, AutoPack tubes
GxF/0.2 µm
GxF/0.2 µm
GxF/0.45 µm, AutoPack tubes
GxF/0.45 µm
GxF/0.45 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc PSF Syringe Filters With PTFE Membrane, 25 mm
IC Acrodisc PSF Syringe Filters With Supor ® Membrane, 25 mm
Part Number
AP-4520
AP-4225
AP-4521
AP-4518
AP-4219
AP-4501
AP-4789
AP-4790
AP-4791
AP-4301
AP-4303
AP-4302
Part Number
AP-4801
AP-4802
AP-4803
Description
0.2 µm, AutoPack tubes
0.2 µm
0.2 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
AP-4587
AP-4585
AP-4785
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Description
0.2 µm, AutoPack tubes
0.2 µm
0.2 µm
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
GxF/0.2 µm, AutoPack tubes
GxF/0.2 µm
GxF/0.2 µm
GxF/0.45 µm, AutoPack tubes
GxF/0.45 µm
GxF/0.45 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc PSF Syringe Filters With Nylon Membrane, 25 mm
Part Number
AP-4437
AP-4436
AP-4522
AP-4517
AP-4438
AP-4502
AP-4786
AP-4787
AP-4788
AP-4548
AP-4549
AP-4528
Description
0.2 µm, AutoPack tubes
0.2 µm
0.2 µm
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
GxF/0.2 µm, AutoPack tubes
GxF/0.2 µm
GxF/0.2 µm
GxF/0.45 µm, AutoPack tubes
GxF/0.45 µm
GxF/0.45 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc PSF Syringe Filters With Glass Fiber, 25 mm
Part Number
AP-4527
AP-4523
AP-4529
12
Description
0.2 µm, AutoPack tubes
0.2 µm
0.2 µm
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
GxF/0.2 µm, AutoPack tubes
GxF/0.2 µm
GxF/0.2 µm
GxF/0.45 µm, AutoPack tubes
GxF/0.45 µm
GxF/0.45 µm
Description
GxF/Glass, AutoPack tubes
GxF/Glass
GxF/Glass
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc PSF Syringe Filters With Versapor ® Membrane, 25 mm
Part Number
AP-4190
AP-4189
AP-4568
AP-4000
AP-4001
AP-4002
Description
0.8 µm, AutoPack tubes
0.8 µm
0.8 µm
10 µm, AutoPack tubes
10 µm
10 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc PSF Syringe Filters With HT Tuffryn® Membrane, 25 mm
Part Number
AP-4498
AP-4497
AP-4784
Description
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc PSF Syringe Filters With Supor® Membrane, 25 mm
Part Number
AP-4798
AP-4799
AP-4800
AP-4424
AP-4425
AP-4426
Description
GxF/0.2 µm, AutoPack Tubes
GxF/0.2 µm
GxF/0.2 µm
GxF/0.45 µm, AutoPack Tubes
GxF/0.45 µm
GxF/0.45 µm
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc Syringe Filters Ensure
Complete Sample Filtration With
Minimal Hold-Up Volumes
Analytical sample prep syringe filters are HPLC certified
Membrane Color Code
for low levels of UV-absorbing extractables. We guarantee
absolute satisfaction.
GH Polypro
PTFE
Nylon
Glass Fiber
pore size on each filter. This makes them ideal for ISO labs.
PES
< 150 mL (3.9
cm2)
< 150 mL (3.9 cm2)
< 150 mL (3.9 cm2)
< 2 mL (0.3 cm2)
< 10 mL (1.0 cm2)
< 10 mL (1.0 cm2)
< 10 mL (1.0 cm2)
< 100 mL (2.8 cm2)
< 100 mL (EFA varies
by device size)
< 200 mL (7.5 cm2)
GH
P
Relative
Throughput (EFA)
Filter Formats
Acrodisc PSF Syringe Filters
25 mm Acrodisc PSF Syringe Filter: designed and
automation certified to address the specific requirements
of automated workstations.
25 mm Acrodisc PSF GxF Syringe Filter: multi-layered
glass prefilter to maximize throughput and meet the
requirements of automated workstations.
25 mm Acrodisc PSF IC Syringe Filter:
optimized to provide consistent results when analyzing
ionic species.
(P
(P
Hy olyp
d r
PT rophilopyle
ic) ne
FE
,
(H
yd
ro
ph
Ny
ob
lon
ic)
(H
yd
ro
ph
PV
ilic
DF
)
(H
yd
r
o
Ve
ph
ilic
rsa
)
p
hil
have color-coded printing indicating membrane type and
e,
(P
Hy oly
dr su
op lfo
hil ne
ic) ,
configurations to fit all applications. Acrodisc syringe filters
PVDF
ic)
HT Hydrolyet
Tu oph hers
i u
ffr
yn lic) lfon
wide range of membrane types, sizes, and packaging
or
(A
Gla
Hy cry
dr lic
ss
o
Fib philicCopo
) lym
er
er,
Su
(H
yd
po
ro
r
p
Traditional Acrodisc syringe filters are available in a
AND
AUTOMATION
CERTIFIED
®
AND
AUTOMATION
CERTIFIED
®
AND
AUTOMATION
CERTIFIED
®
Acrodisc Syringe Filters
4 mm Acrodisc Syringe Filter: ideal for filtration when sample size
is minimal.
13 mm Acrodisc Syringe Filter: multiple filter selection for both
aqueous and solvent-based sample filtration.
13 mm Acrodisc Syringe Filter with Minispike: minispike configuration
offers lower hold-up volume and easy filtration into autosampler vials.
13 mm IC Acrodisc Syringe Filter: convenient size for small sample
volumes of ionic solutions.
25 mm Acrodisc Syringe Filter: multiple membrane selections for
compatibility with aqueous and organic solvents.
Non-Sterile Acrodisc Syringe Filter (modified acrylic housings): for
general aqueous samples, prefiltration, and clarification. Not HPLC certified.
37 mm GF Acrodisc Syringe Filter: additional filtration area for very
dirty samples. Not HPLC certified.
Note: All HPLC- and IC-certified Acrodisc syringe filters are made with polypropylene housings
and male luer outlets; the 13 mm is also available with minispike outlets.
www.pall.com/lab
13
Applications
Sample prep for UHPLC
Sample prep for microbore columns
For use when concerned with microbial growth
Reference Material
Also available online in our Literature Library
at www.pall.com/lab.
Product Data, SolVac® Filter Holder
Product Data, Vacuum/Pressure Pumps
Product Data, Stainless Steel Forceps
High Performance UHPLC Sample Prep
Filtration Provides Increased Column
Life and the Best Chromatography
UHPLC requires stringent sample preparation to improve
chromatography and extend column life. The smaller column
packing sizes in UHPLC columns require smaller pore sized
Ordering Information
Acrodisc Syringe Filters With GHP Membrane, 13 mm
Part Number
4554
4567
4556
4563
Description
0.2 µm, minispike outlet
0.2 µm, minispike outlet
0.45 µm, minispike outlet
0.45 µm, minispike outlet
sample prep filters. These 0.2 µm syringe filters and
Acrodisc Syringe Filters With GHP Membrane, 25 mm
membranes have been developed for UHPLC sample prep
Part Number
4564
4566
4560
4562
4559
4558
and mobile phase filtration. The 0.2 µm pore size assures
removal of the contaminant size most likely to plug a UHPLC
column and offers better protection of your analytical results.
As with other pore size Acrodisc® syringe filters, these
Description
0.2 µm
0.2 µm
0.45 µm
0.45 µm
GF/0.45 µm
GF/0.45 µm
Pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
Pkg
50/pkg, 200/cs
1000/pkg
50/pkg, 200/cs
1000/pkg
50/pkg, 200/cs
1000/pkg
UHPLC filter membranes (GHP, nylon, PVDF, and PTFE) are
HPLC certified for low levels of UV absorbing extractables.
Acrodisc Syringe Filter With PTFE Membrane, 4 mm
Acrodisc PSF syringe filters are available with a GxF
Part Number
4472
Description
0.45 µm
Pkg
250/pkg, 750/cs
multi-layer prefilter which provides two to four times the
throughput of standard glass fiber prefilter devices, allowing
Acrodisc Syringe Filters With PTFE Membrane, 13 mm
quick and easy filtration of your most difficult to filter solutions.
Part Number
4552
4553
4555
4423
4542
4422
4543
Pall’s 13 mm Acrodisc syringe filter can also be purchased
with a 13 mm minispike outlet for lower hold-up volume and
easier filtration into autosampler vials without airlock.
14
Description
0.2 µm, minispike outlet
0.45 µm, minispike outlet
0.45 µm, minispike outlet
0.2 µm, male slip luer outlet
0.2 µm, male slip luer outlet
0.45 µm, male slip luer outlet
0.45 µm, male slip luer outlet
Pkg
100/pkg, 300/cs
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
Acrodisc Syringe Filters With PTFE Membrane, 25 mm
Part Number
4225
4521
4518
4219
4501
4226
4503
Description
0.2 µm
0.2 µm
0.45 µm, AutoPack™ tubes
0.45 µm
0.45 µm
1 µm
1 µm
Acrodisc Syringe Filters With PVDF Membrane, 13 mm
Pkg
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
50/pkg, 200/cs
1000/pkg
Part Number
4450
4544
4452
4545
4455
4457
Description
0.2 µm, minispike outlet
0.2 µm, minispike outlet
0.45 µm, minispike outlet
0.45 µm, minispike outlet
0.2 µm, male slip luer outlet
0.45 µm, male slip luer outlet
Pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
100/pkg, 300/cs
Acrodisc Syringe Filters With PVDF Membrane, 25 mm
Acrodisc Syringe Filter With Nylon Membrane, 4 mm
Part Number
4484
Description
0.45 µm
Pkg
250/pkg, 750/cs
Acrodisc Syringe Filters With Nylon Membrane, 13 mm
Part Number
4550
4561
4551
4546
4427
4540
4426
4541
Description
0.2 µm, minispike outlet
0.2 µm, minispike outlet
0.45 µm, minispike outlet
0.45 µm, minispike outlet
0.2 µm, male slip luer outlet
0.2 µm, male slip luer outlet
0.45 µm, male slip luer outlet
0.45 µm, male slip luer outlet
Pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
100/pkg, 300/cs
1000/pkg
Part Number
4406
4520
4519
4408
4500
Description
0.2 µm
0.2 µm
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
Pkg
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Ion Chromatography Acrodisc Syringe Filters, 13 mm
Part Number
4483
4683
4485
4685
Description
0.2 µm
0.2 µm
0.45 µm
0.45 µm
Pkg
100/pkg, 300/cs
1000/pkg
100/pkg,300/cs
1000/pkg
Ion Chromatography (PES) Acrodisc Syringe Filters, 25 mm
Acrodisc Syringe Filters With Nylon Membrane, 25 mm
Part Number
4436
4522
4517
4438
4502
4548
4549
4528
Description
0.2 µm
0.2 µm
0.45 µm, AutoPack tubes
0.45 µm
0.45 µm
GF/0.45 µm, AutoPack tubes
GF/0.45 µm
GF/0.45 µm
Pkg
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Acrodisc Syringe Filters With Glass Fiber, 25 mm
Part Number
4527
4523
4529
Description
1 µm (nominal), AutoPack tubes
1 µm (nominal)
1 µm (nominal)
Pkg
25/pkg, 200/cs
50/pkg, 200/cs
1000/pkg
Part Number
4583
4783
4585
4785
Description
1 µm (nominal), polypropylene housing
Pkg
15/pkg, 60/cs
Pkg
50/pkg, 200/cs
1000/pkg
50/pkg, 200/cs
1000/pkg
Acrodisc Syringe Filters With Versapor® Membrane, Non-Sterile
Part Number
4473
4459
4488
4489
Description
0.45 µm, 4 mm
0.8 µm, 13 mm, polypropylene housing
1.2 µm, 25 mm, modified acrylic housing
5 µm, 25 mm, modified acrylic housing
Pkg
250/pkg, 750/cs
300/cs
75/pkg, 300/cs
75/pkg, 300/cs
Acrodisc Syringe Filters With Supor® Membrane, Non-Sterile
Part Number
4655
4659
Acrodisc Syringe Filter With Glass Fiber, 37 mm
Part Number
4524
Description
0.2 µm
0.2 µm
0.45 µm
0.45 µm
4653
4661
4660
4662
Description
0.2 µm, 32 mm, modified acrylic housing
0.8/0.2 µm, 32 mm, modified acrylic
housing
0.45 µm, 32 mm, modified acrylic housing
1.2/0.45 µm, 32 mm, modified acrylic
housing
1.2 µm, 32 mm, modified acrylic housing
5 µm, 32 mm, modified acrylic housing
Pkg
1000/pkg
1000/pkg
1000/pkg
1000/pkg
1000/pkg
1000/pkg
www.pall.com/lab
15
Nanosep® Centrifugal Devices are Ideal
When Sample Recovery is a Concern
96.5% Protein Recovery
GH Polypro membrane is a low protein binding membrane.
It removes unwanted particulate from samples with high
recovery of critical proteins.
Low Extractables
Our HPLC-grade centrifugal devices are certified to be low
in UV extractables.
Leak-Free Operation
Unique sealing technology assures leak-free operation
without the use of o-rings or adhesives that can
add extractables.
Applications
Sample prep – particulate removal prior to sample
analysis, HPLC grade
Removal of precipitates, including metals,
polymers, and crystals
Removal of cells from media prior to analysis
GHP Nanosep MF centrifugal devices are perfect for
particulate removal prior to analytical sample analysis.
The high g-force rating allows spinning at 14,000 x g,
assuring rapid sample processing.
Special Features
Rapid Processing of Samples
Centrifugal devices are simple to use and save on sample
preparation time. Spin multiple samples at once.
Universal Membrane Filter
The GH Polypro hydrophilic polypropylene membrane is
ideal for aqueous solutions and offers maximum chemical
compatibility for aggressive solvents.
16
Applications requiring maximum filtrate (or retentate)
recovery from limited sample volumes
Ordering Information
GHP Nanosep MF Centrifugal Devices
Part Number
ODGHPC34
ODGHPC35
Description
0.45 µm, clear
0.45 µm, clear
Pkg
100/pkg
500/pkg
Simplify Clean-Up and Degassing of Mobile
Phase Solvents With a SolVac ® Filter Holder
Special Features
Versatile Design Fits Most HPLC Bottles,
Flasks, and Containers
Eliminates the added step of transferring mobile
phase solvent from flask to reservoir, which can
cause contamination.
Draws Directly From HPLC Solvent Bottles
Less likely to spill aggressive solvents than glass
funnels or disposable cups.
Durable Plastic Construction
Resists breaking, unlike glass funnels, assemblies,
or pick-up adapters.
Leak-Proof Patented Magnetic Seal
Eliminates membrane shifting or tearing which can
occur with aluminum clamps or threaded holders.
Ordering Information
SolVac Filter Holder for Mobile Phase
Part Number
4020
How to Use
1. Place base on the receiving vessel.*
Place the membrane on the clean,
dry filter support.
2. Attach inlet feedline tubing to the upper
housing. Place upper housing onto housing
base to securely seal the membrane.
3. Attach vacuum tubing from vacuum
source to the vacuum port adapter
on the housing base.
4. Place feedline tubing into solvent
to be filtered.
5. Apply vacuum to pull liquid through
the filter.
4022
4023
4025
4026
4028
Description
SolVac holder with 61 cm (2 ft.) feedline tubing,
thumb clamp, sinker, vacuum port adapter,
2 membrane seal gaskets, and 2 seal gaskets
122 cm (4 ft.) replacement feedline tubing
Replacement seal gaskets
Membrane seal gasket kit
Sinker replacement kit
Clamp replacement kit
Pkg
1/pkg
1/pkg
10/pkg
10/pkg
2/pkg
2/pkg
Mobile Phase Membranes
Part Number
66557
66628
66548
66625
66143
66630
66149
66631
66477
66480
66602
66608
Description
0.2 µm, 47 mm GH Polypro (PP)
0.2 µm, 50 mm GH Polypro (PP)
0.45 µm, 47 mm GH Polypro (PP)
0.45 µm, 50 mm GH Polypro (PP)
0.2 µm, 47 mm TF (PTFE)
0.2 µm, 50 mm TF (PTFE)
0.45 µm, 47 mm TF (PTFE)
0.45 µm, 50 mm TF (PTFE)
0.2 µm, 47 mm FP Vericel™ (PVDF)
0.45 µm, 47 mm FP Vericel (PVDF)
0.2 µm, 47 mm Nylaflo™ (Nylon)
0.45 µm, 47 mm Nylaflo (Nylon)
Pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
100/pkg
*Always use a safety-coated receiving vessel that is less than 4 L and
rated for vacuum applications. Failure to do so may result in implosion
of the receiving vessel and potential injury to the user.
www.pall.com/lab
17
47 mm Glass Filter Funnels for Vacuum
Filtration of Liquids and Degassing
of HPLC Solvents and Mobile Phases
Mobile Phase Membranes
Pall membrane disc filters provide purification and degassing
of mobile phase solvents used in liquid chromatography
applications. The membranes are identical in composition
and quality to those used in our HPLC-certified
Acrodisc® syringe filters.
HPLC Mobile Phase Filtration Membranes
Membrane
TF (PTFE)
Mobile Phase Application
Recommended for use with all lower surface
tension liquids
GHP (Polypropylene) Recommended for use with organics and
aqueous liquids
Nylaflo™ (Nylon)
Not recommended for use with certain acidic solutions
FP Vericel™ (PVDF) Not recommended for use with certain basic solutions
Supor® (PES)
Not recommended for use with certain ketones
Ordering Information
47 mm Glass Filter Funnels
Special Features
Part Number
4011
Resistant to Aggressive Solvents
Funnel is made of 100% borosilicate glass, assuring
4012
resistance to even the most aggressive solvents.
4013
Description
Glass filter funnel with No. 8 stopper
support base (300 mL funnel, no flask)
Glass filter funnel with sidearm support
assembly and flask (1 L funnel with 4 L flask)
Glass filter funnel with sidearm support assembly
and flask (300 mL funnel with 1 L flask)
Pkg
1/pkg
1/pkg
1/pkg
Filter an Entire Liter at Once
One-liter 47 mm glass funnel/support assembly
permits filtration of an entire liter at once.
Unique Design
Support assembly’s unique base design with integral
Replacement Parts
47 mm Glass Filter Funnel (for PN 4011)
Part Number
4014
4019
81595
Description
Upper glass funnel, 300 mL
Fritted glass support base/No. 8 silicone stopper
Aluminum clamp, anodized
Pkg
1/pkg
1/pkg
1/pkg
vacuum connection prevents contamination of the
vacuum line with filtrate.
Easy to Read
One-liter glass funnel is graduated from 300 to 1000 mL
in 50 mL increments. 300 mL glass funnel is graduated
from 100 to 250 mL in 25 mL increments. Stepped stem
fits into standard one-hole stoppers (9 mm).
18
47 mm Glass Funnel/Support Assembly (for PN 4012, 4013)
Part Number
4015
4018
4016
4017
81595
Description
Glass funnel, 1 L
Glass flask, 1L
Glass flask, 4 L
Fritted glass support base with sidearm
Aluminum clamp, anodized
Pkg
1/pkg
1/pkg
1/pkg
1/pkg
1/pkg
Eth
yl a
cet
ate
Eth
yl e
the
r
Fre
on
TF
Hyd
roc
hlor
ic
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
L
R
R
R
R
R*
R
R*
R*
R
R
R*
R*
R*
R
R
R
R
R
R
R
R
R
L
R
R*
R*
R*
R*
R
R
L
R
L
R
R
R
R
R
N
N
R
R*
R
R
R
R
R
R
N
N
R
N
R
N
R
R
R
R*
R*
R
R*
R
R
N
R
R
R
R*
R*
R
N
R
R
R
N
•
N
N
R
N
R
L
R
L
R
N
N
N
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
N
N
N
N
R
N
N
R
L
N
L*
N
N
N
N
N
N
N
N
N
R*
•
L
N
N
N
N
N
N
N
N
R*
N
L*
R
R
N
R
Ace
ton
itril
e
Ace
tic
acid
, gl
acia
n-B
l
uta
nol
Chl
oro
form
Dio
xan
e
R
Ace
ton
e
Dim
eth
yl f
orm
am
Dim
ide
eth
yl s
ulfo
xide
Eth
ano
l
acid
Hex
(1N
)
ane
, dr
y
Me
tha
nol
Me
thy
lene
chlo
ride
Me
thy
l et
hyl
ket
N-M
one
eth
ylpy
rrol
idon
Isop
e
rop
ano
l
Sod
ium
hyd
rox
Tetr
ide
ahy
(3N
dro
)
fura
n
Tetr
ahy
dro
fura
n/w
Tolu
ate
r (5
ene
0/5
0)
Wa
ter
Chemical Compatibility Guide
Devices with GH Polypro (GHP) membrane (hydrophilic polypropylene)
R
R
R
R
R*
R
R
13 & 25 mm, AcroPrep™ R*
R
R
R
R
R
•
L
R
R*
R
R
N
•
R*
R
L
R
R
R*
R
R
R
N
•
R
R
R
R
L
L
•
R
R
N
N
R
R
N
•
N
R
N
N
N
L
R
N
•
N
R
N
N
N
L
R
N
•
N
R
Devices with PTFE membrane
4 mm
Devices with PVDF membrane
N
Devices with Nylon membrane
R*
Devices with Supor PES membrane
Devices with Glass Fiber
Devices with Versapor® membrane (modified acrylic housing)
N
N
N
R
Devices with Supor membrane (modified acrylic housing)
N
L
N
R
Devices with HT Tuffryn® membrane (modified acrylic housing)
N
N
N
R
R
R
N
R
R
R
R
R
Disc Filters
GH Polypro
R
R
FP Vericel (PVDF)
N
R
Nylaflo (Nylon)
R
R
TF (PTFE)
R
R
R
R
R
R
R
R
R
R
R
R
N
N
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
N
N
R
N
N
•
R
R
R
R
R
R
R
R
L
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
* UV absorbance was set at 254 nm.
Test Methods
The data presented in this chart is a compilation of testing by
Pall Corporation with certain chemicals, manufacturer’s data,
or compatibility recommendations from the Compass Corrosion
Guide, by Kenneth M. Pruett. This data is intended to provide
expected results when filtration devices are exposed to chemicals under static conditions for 48 hours at 25 °C (77 °F), unless
otherwise noted. This chart is intended only as a guide.
Accuracy cannot be guaranteed. Users should verify chemical
compatibility with a specific filter under actual use conditions.
Chemical compatibility with a specific filter, under actual use
conditions, is affected by many variables including temperature,
pressure, concentration, and purity. Various chemical combinations prevent complete accuracy.
R = Resistant
No significant change was observed in flow rate or bubble point
of the membrane.
L = Limited Resistance
Moderate changes in physical properties or dimension of the
membrane were observed. The filter may be suitable for short
term, non-critical use at room temperature.
N = Not Resistant
The membrane is basically unstable. In most cases, extensive
shrinkage or swelling occurs. The filter may gradually weaken or
partially dissolve after extended exposure.
• = Insufficient Data
Information not available. Trial testing is recommended.
www.pall.com/lab
19
Visit us on the Web at www.pall.com/lab
E-mail us at LabSupport@pall.com
Pall Life Sciences
600 South Wagner Road
Ann Arbor, MI 48103-9019 USA
1.800.521.1520 USA and Canada
(+)800.PALL.LIFE Outside USA and Canada
1.734.665.0651 phone
1.734.913.6114 fax
International Offices
Pall Corporation has offices and plants throughout the world in: Argentina, Australia, Austria, Belgium, Brazil, Canada,
China, France, Germany, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, New Zealand, Norway, Philippines,
Poland, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, United Kingdom, and Vietnam.
Distributors in all major industrial areas of the world.
To locate the Pall office or distributor nearest you, visit www.pall.com/contact.
The information provided in this literature was reviewed for accuracy at the time of publication. Product data may be
subject to change without notice. For current information consult your local Pall distributor or contact Pall directly.
© 2011, Pall Corporation. Pall,
, Acrodisc, AcroPrep, AutoPack, Mustang, Nanosep, Nylaflo, Supor, SolVac,
Tuffryn, Vericel, and Versapor are trademarks of Pall Corporation. ® indicates a trademark registered in the USA.
Filtration.Separation.Solution. is a service mark of Pall Corporation. ◆Alliance is a trademark of Waters Corporation.
VICTOR is a trademark of PerkinElmer, Inc. APW, MultiDose, SMART, SOTAX, TPW, and Zymark are trademarks of
SOTAX Ag.
4/11, 5k, GN10.4380
PN33584
Download