2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 1 Data Sheet PM&E 2050/2060/2070-A 2050/2060/2070 Series High Pressure Filter Assemblies Features • Ultipor ® III or Rigimesh® stainless steel media • Flows to 75 lpm (20 gpm) • Pressures: 2050 Series: 690 bar (10,000 psi) 2060 Series: 1034 bar (15,000 psi) 2070 Series: 1379 bar (20,000 psi) • Port sizes: 3/8″, to 3/4″ Notes and Specifications Pressure Drop Information Figure 1. Housing pressure drop using fluid with 0.9 S.G. Housing pressure drop is directly proportional to specific gravity. 2050/2060 Series Flow (lpm) 0 10 20 30 40 50 60 70 50 2070 Series Flow (lpm) 0 10 20 30 40 50 60 50 3.0 40 V06 V09 W12 V12 20 2.0 1.0 10 P (bar) 30 0 0 0 2 4 Flow (gpm) 6 8 10 12 14 16 Element Pressure Drop Multiply actual flow rate times factor to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 lpm and per 1 gpm. 9020 Series Filter Elements — bar/1000 lpm (psid/gpm) Length Code KZ KP KN KS KT 4 8 14.94 (0.82) 7.47 (0.41) 9.84 (0.54) 4.92 (0.27) 6.38 (0.35) 3.28 (0.18) 3.83 (0.21) 2.00 (0.11) 34.61 (1.90) 17.49 (0.96) 3.0 9021 Series Filter Elements — bar/1000 lpm (psid/gpm) B06 V09 V06 30 2.0 20 1.0 A, B, C, W 08/12 1 10 0 0 0 2 4 Flow (gpm) 6 8 10 12 14 16 18 20 Δ P (bar) 40 Δ P (psid) 2050, 2060, and 2070 series filter housings P (psid) Maximum Working Pressure: 2050 series: 690 bar (10,000 psi) 2060 series: 1000 bar (14,500 psi) 2070 series: 1379 bar (20,000 psi) Proof Pressure: 2050 series: 1034 bar (15,000 psi) 2060 series: 1500 bar (21,750 psi) 2070 series: 2068 bar (30,000 psi) Typical Burst Pressure: 2050 series: 2758 bar (40,000 psi) 2060 series: 3490 bar (50,750 psi) 2070 series: 5516 bar (80,000 psi) Temperature Range: Nitrile seals: -43˚C to 107˚C (-45˚F to 225˚F) Fluorocarbon Seals: -29˚C to 120˚C (–20˚F to 250˚F) 60˚C (140˚F) maximum in HWCF or water glycol fluids with Ultipor III media Filter Element Collapse Pressure: 9020 series: 20 bar (290 psid); 9021 series: 207 bar (3000 psid); 310 bar (4500 psid) with Rigimesh all stainless steel media (NK or NJ options) Materials of Construction: Stainless steel; titanium bowl (2070/71) Element Construction: Ultipor III: Inorganic fibers impregnated and bonded with epoxy resins; stainless steel hardware. Rigimesh: All stainless steel (no resin binders) Length Code DP DS/NK 4 8 49.37 (2.71) 24.59 (1.35) 36.54 (0.53) 12.39 (0.68) 17.24 (0.25) 6.19 (0.34) DT/NJ 12/19/05 2:29 PM Page 2 Dimensional Drawings 2X 10.31 mm Ø.406 in 22.10 mm .87 in INLET Visual indicator Explosion proof indicator OUTLET 57.15 mm 2.25 in OUTLET INLET 69.85 mm 2.75 in 24.99 mm .984 in 4 X 3/8-16 UNC 2B .70 deep Element Series Housing Element Length (in)* Code Code KZ 3 9020 (Ultipor III) R 4 4 KP 5 9020 (Ultipor III) S 8 8 KN 7 9020 (Ultipor III) * Nominal length KS 12 9020 (Ultipor III) KT 22 9020 (Ultipor III) DP 5 9021 (Ultipor III) Table 1: Seal Options DS 12 9021 (Ultipor III) Code Seals DT 15 9021 (Ultipor III) H Nitrile NK 5 µm* 9021 (Rigimesh) Z Fluorocarbon NJ 10 µm* 9021 (Rigimesh) 27.99 mm 1.102 in T Table 4 Table 2 Table 4 Table 5 Table 5 Rigimesh Element P/N: HC 9021 E Table 4 Table 5 Table 6 Table 7 Table 8 Y923 Table 1 Table 1 * 98% efficiency Table 2: Series Options Housing Code Description 50 60 70 Table 5: Length Options Bx(c) ≥ 1000 Assembly P/N: H 20 Table 2 Table 3 Table 4: Filter Element Options Code Ordering Information Table 1 Mounting dimensions same as other options. 24.99 mm .984 in Secondary port location (2050/51 and 2060/61 only) Ultipor Element P/N: HC F 111.4 mm Ø4.385 in INLET 30.23 mm 1.19 in 95 mm 3.75 in Element change 104.8 mm 4.125 in V12 port option only 92.20 mm 3.63 in Primary port location (2050/51 and 2060/61 only) 1.19 Hex. 101 mm 4 in ‘H’ Dim. Ref. 150 Ref. mm 5.9 Ref. in OUTLET 249.94 mm/9.84 in (R-length) 345.44 mm/13.60 in (S-length) 25.4 mm ‘H’ Dim. 1.00 in Ref. OUTLET 2050-2060-2070glr1.qxd Element Code Code Valve Housing Series B 3.4 bar (50 psid ) 2050, 2060, 2070 J 10 bar (150 psid ) 2051, 2061, 2071 S 13.8 bar (200 psid ) 2051, 2061, 2071 9020 W Non-bypass, 100 psid indicator 2051, 2061, 2071* Non-bypass, 35 psid indicator 2051, 2061, 2071* 690 bar (10,000 psi) housing with 50 psi bypass valve 9020 1000 bar (14,500 psi) housing with 50 psi bypass valve 9020 1379 bar (20,000 psi) housing with 50 psi bypass valve Table 6: Bypass Valve Options 51 690 bar (10,000 psi) 9021 N 61 1034 bar (15,000 psi) 9021 * Note: 2071 series does not have indicator ports 71 1379 bar (20,000 psi) 9021 Table 7: Differential Pressure Indicator Options* Table 3: Port Options Code Indicator ‘H’ Dim. Code Port W Explosion proof 79 mm (3.1 in) A08 1 E SST visual 28 mm (1.1 in) 0 No indicator port N/A B SST port plug 3 mm (0.12 in) Series /2″ SAE J514 straight thread 2050/51, 2060/61 /4″ SAE J514 straight thread 2050/51 /8″ NPT 2050/51, 2060/61 /2″ NPT 2050/51, 2060/61 /4″ NPT 2050/51 /2″ BSP ISO 228 threads 2050/51, 2060/61 /4″ BSP ISO 228 threads 2050/51 A12 3 B06 3 B08 1 B12 3 C08 1 C12 3 V06 3 V09 9 V12 3 W12 3 *Notes: 1. Select 2 indicator option codes per housing 2. Enter indicator codes alphabetically; put “0” code after alpha code if applicable 3. 2070/71 series does not have indicator ports; enter “00” in part number /8″ medium pressure threaded 2050/51, 2060/61, 2070 Table 8: Mounting Bracket Options /16″ medium pressure threaded 2050/51, 2060/61, 2070 Code /4″ medium pressure threaded 2050/51, 2060/61, 2070 0 None /4″ weld sockets 2050/51 1 Mounting bracket kit Option Visit us on the Web at www.pall.com/m&e New York – USA +1 516 484 3600 telephone +1 888 333 7255 toll free +1 516 625 3825 fax Portsmouth – UK +44 (0)23 9230 3303 telephone +44 (0)23 9230 2507 fax m&e_sales@pall.com © Copyright 2005, Pall Corporation. Pall, , Ultipor and Rigimesh are trademarks of Pall Corporation. ® Indicates a Pall trademark registered in the USA. is a service mark of Pall Corporation.