SYMBOL SCHEDULE
SHEET LIST
S
SYMBOL DESCRIPTION
LOUDSPEAKER
(CEILING)
S
LOUDSPEAKER
(WALL)
PA
PA LOUDSPEAKER
(CEILING)
PA
PA LOUDSPEAKER
(WALL)
M
MICROPHONE
SUBSCRIPT
N
SUBSCRIPT DESCRIPTION
MOUNTING
N
ACCESSIBLE CEILING
NON ACCESSIBLE CEILING
TELECOM OUTLET VOICE/DATA
+XY"
AC
BC
E
F
FB
FP
W
WAP
DETAILS
FLUSH/WALL
FLUSH/WALL
FLUSH/WALL
FLUSH/COUNTER
FLUSH/WALL
FLUSH/WALL
FLOOR BOX
FLUSH/WALL
FLUSH/WALL
FLUSH/WALL
NON STANDARD HEIGHT
ABOVE COUNTER
BELOW COUNTER
EMERGENCY INFORMATION BOARD
FURNITURE
FLOOR BOX
FLAT PANEL
WALL TELEPHONE
WIRELESS ACCESS POINT
T0.01
TECHNOLOGY TITLE SHEET
T2.01
FIRST FLOOR TECHNOLOGY PLAN
T2.03
THIRD FLOOR TECHNOLOGY PLAN
T4.01
TECHNOLOGY ONE LINES
T5.01
TECHNOLOGY DETAILS
FLOOR BOX
CEILING
PA
A
B
PUBLIC ADDRESS
TELECOM OUTLET VOICE/DATA
(CEILING)
1/T5.01, 3/T5.01
TELECOM OUTLET VOICE/DATA
(FIELD COORDINATED)
CEILING
CEILING
CEILING
WIRELESS MIC ANTENNA
ASSISTED LISTENING
WALL
A
PROJECTION SCREEN
(CEILING)
70 INCH DISPLAY
80 INCH DISPLAY
60 x 96 INCH
WALL
WALL
2/T5.01
2/T5.01
CEILING
5/T5.01
AV
DP
FUT
P
SC
WAP
AV
B
ELEC
ELV
FACP
M
OXYGEN
S
SC
SM
U
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
AUDIOVISUAL
DISPLAY PANEL
FUTURE
PROJECTOR
SECURITY CAMERA
WIRELESS ACCESS POINT
AUDIOVISUAL
BUILDING AUTOMATION
ELECTRICAL
ELEVATOR
FIRE ALARM CONTROL PANEL
MECHANICAL/HVAC
OXYGEN
SECURITY PANEL
SECURITY CAMERA
SURFACE MOUNTED
UPS
CATV OUTLET
WALL
PROJECTION SCREEN
(WALL)
IF
MOUNTING
TELECOM OUTLET
(FLOOR BOX)
WALL
WALL
INTERFACE PLATE
(FLOOR BOX)
SUBSCRIPT DESCRIPTION
WALL
EQUIPMENT RACK
(WALL)
INTERFACE PLATE
SUBSCRIPT
CEILING
CEILING
ANTENNA
(WALL)
IF
SYMBOL DESCRIPTION
WALL
FLOOR
VIDEO DISPLAY
(WALL)
SYMBOL
CEILING
CEILING
ACCESSIBLE CEILING
NON ACCESSIBLE CEILING
EQUIPMENT RACK
(FLOOR)
ANTENNA
(CEILING)
DETAILS
Empowered Business 9 Quiet Technology
TITLE
W2A
W2B
W2P
W3A
W3B
(SEE ABOVE)
WALL
WALL
WALL
WALL
WALL
2
2
2
3
3
GANG
GANG
GANG
GANG
GANG
WALL
WALL
WALL
WALL
WALL
TYPE A
TYPE B
TYPE P
TYPE A
TYPE B
(SEE ABOVE)
TELECOM OUTLET VOICE/DATA
(FIELD COORDINATED) (CEILING)
AV
TA
CEILING
ABOVE CEILING
ABOVE CEILING
AUDIOVISUAL
TIME ATTENDANCE
TELECOM OUTLET SPECIALTY
+XY"
AV
OR
FLOOR BOX
A
TELECOM WORK SHALL BE PROVIDED BY OWNER'S CONTRACTORS.
AV CONTRACTOR SHALL COORDINATE WITH OWNER AND OWNER'S
CONTRACTORS FOR ALL REQUIRED LOCATIONS OF TELECOM WORK
B
ALL WORK SHALL CONFORM TO UNIVERSITY STANDARDS. PROVIDE
ALL MATERIAL AND EXECUTION OF WORK AS REQUIRED TO DELIVER
A COMPLETE, FUNCTIONAL, AND TESTED INSTALLATION
C
THE AV CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING
ELECTRICAL POWER AND ROUGH IN NECESSARY FOR SUPPORT OF
AV SCOPE OF WORK AS INDICATED ON TECHNOLOGY (T SERIES)
CONSTRUCTION DOCUMENTS. FOR THIS PURPOSE, THE AV
CONTRACTOR SHALL SUBCONTRACT A DESIGN BUILD ELECTRICAL
CONTRACTOR. SUCH DESIGN BUILD ELECTRICAL CONTRACTOR
SHALL PERFORM WORK IN CONFORMANCE WITH UCCS AND BASE
BUILDING STANDARDS AND COMPLY WITH LOCAL AHJ
REQUIREMENTS. SCOPE OF SERVICES SHALL INCLUDE, BUT NOT BE
LIMITED TO:
1
SELECTION OF A UCCS APPROVED DESIGN BUILD
ELECTRICAL CONTRACTOR BASED ON CRITERIA ESTABLISH
IN TECHNOLOGY CONSTRUCTION DOCUMENTS (DRAWINGS
AND SPECIFICATIONS)
2
ACQUIRE COMPETITIVE PRICING FROM A MINIMUM OF
THREE DESIGN BUILD ELECTRICAL CONTRACTORS BASED
ON SCOPE OF TECHNOLOGY CONSTRUCTION DOCUMENTS
AND ELECTRICAL POWER REQUIREMENTS TO SUPPORT
SUCH
3
MANAGE ALL BUSINESS AND CONTRACTUAL ASPECTS
RELATED TO INTERFACE BETWEEN UCCS (OWNER) AND
SUBCONTRACTOR (DESIGN BUILD ELECTRICAL
CONTRACTOR)
4
COORDINATION WITH OWNER FOR FINAL SELECTION OF
SUCH SUBCONTRACTOR BASED ON QUALIFICATIONS AND
PRICING
5
ACQUISITION AND PROVISION OF REQUIRED CURRENT
RECORD DOCUMENTS TO ELECTRICAL CONTRACTOR
6
FIELD SURVEY BY ELECTRICAL CONTRACTOR FOR
VERIFICATION OF EXISTING CONDITIONS
7
ACQUISITION AND PROVISION OF REQUIRED ELECTRONIC
AUTOCAD DRAWINGS AND NECESSARY DRAWING AND
SPECIFICATION FORMAT CRITERIA TO ELECTRICAL
CONTRACTOR FOR PREPARATION OF ELECTRICAL
CONSTRUCTION DOCUMENTS (DRAWINGS AND
SPECIFICATIONS)
8
VERIFICATION BY AV CONTRACTOR THAT DESIGN AND
DOCUMENTATION PREPARED BY ELECTRICAL
CONTRACTOR IS APPROPRIATE FOR SUPPORT OF AV
SCOPE OF WORK AND IN CONFORMANCE WITH OTHER
CONSTRUCTION DOCUMENT CRITERIA. SUCH ELECTRICAL
CONSTRUCTION DOCUMENTS SHALL CONFORM TO
APPEARANCE, FORMAT, AND OTHER CHARACTERISTICS
ESTABLISHED BY TECHNOLOGY CONSTRUCTION
DOCUMENTS
9
PREPARATION OF 95% CONSTRUCTION DOCUMENTS
(DRAWINGS AND SPECIFICATIONS) AND PRICING FOR
OWNER REVIEW INCLUDING NECESSARY CHANGES TO
EXISTING ELECTRICAL DISTRIBUTION AND LOAD SUMMARY
JUSTIFICATION AS REQUIRED
10
PREPARATION OF 100% CONSTRUCTION DOCUMENTS
BASED ON OWNER REVIEW COMMENTS
11
SUBMITTAL TO BUILDING DEPARTMENT FOR PERMIT WITH
MODIFICATIONS AND RESUBMITTAL AS NECESSARY FOR
ACQUISITION OF BUILDING PERMIT
12
PROVISION OF PARTS AND LABOR AS INDICATED BY SUCH
CONSTRUCTION DOCUMENTS AND ALL WORK NECESSARY
TO PROVIDE A COMPLETE TESTED ELECTRICAL SYSTEM
FOR SUPPORT OF SCOPE OF WORK INDICATED ON
TECHNOLOGY CONSTRUCTION DOCUMENTS
13
PRODUCT SUBMITTALS FOR OWNER REVIEW
14
REQUIRED BUILDING DEPARTMENT INTERMEDIATE AND
FINAL INSPECTIONS AS REQUIRED FOR ACQUISITION OF
CERTIFICATE OF OCCUPANCY
15
PREPARATION OF RECORD DOCUMENTS
FLUSH/WALL
1/T5.01, 3/T5.01
1/T5.01, 2/T5.01, 3/T5.01
3/T5.01
PROJECT NOTES
FLUSH/WALL
FLUSH/WALL
FLUSH/WALL
FLUSH/WALL
NON STANDARD HEIGHT
AUDIOVISUAL
OR INTEGRATION
TELECOM OUTLET SPECIALTY (CEILING)
STATION CALLOUT SCHEDULE
CEILING
USAGE
PROJECTOR
CEILING
A
FIXED CAMERA
(CEILING)
CEILING
A
PAN TILT ZOOM CAMERA
(CEILING)
CEILING
4/T5.01
LADDER RACK
FIXED CAMERA
(WALL)
WALL
PAN TILT ZOOM CAMERA
(WALL)
WALL
(#) NUMBER OF COAX PORTS/CABLES
(#) NUMBER OF DATA (CAT5E) PORTS/CABLES
(#) NUMBER OF VOICE (CAT5E) PORTS/CABLES
CABLE CONTINUOUS LOOP
SR
A
###
CABLE END LOOP
J
SURFACE RACEWAY
J HOOK PATHWAY
EXAMPLES
A
PODIUM
V
VOLUME CONTROL
CP
CONTROL PANEL
FLOOR
0 VOICE (CAT5E), 1 DATA (CAT5E), 0 COAX
WALL
L
S
VC
010
WALL
LARGE WIRELESS W/ DOCKING
STATION
SMALL FIXED
WALL
VOLUME CONTROLLER
WALL
SCREEN SWITCH
WALL
FURNISH | INSTALL CALLOUT SCHEDULE
SYMBOL
X
Y
10807 New Allegiance Drive, Suite 400
Colorado Springs, CO 80921
Voice: (719) 53391112 9 Fax: (719) 53391113
info@rimrockgroup.com 9 www.rimrockgroup.com
UCCS
UNIVERSITY CENTER AV INTEGRATION
SYMBOL
SHEET#
TELECOMMUNICATION SYSTEM NOTATION
AUDIOVISUAL SYSTEM NOTATION
RIMROCK GROUP
ENTITY RESPONSIBLE FOR INSTALLING
ENTITY RESPONSIBLE FOR FURNISHING
ABBREVIATIONS
ABBREV.
DEFINITION
ABBREV.
DEFINITION
ABBREV.
DEFINITION
ABBREV.
DEFINITION
AC
ACEG
ACP
ACS
AFF
AHJ
ALS
AO
AOC
APC
APP
APPROX
AR
ARCH
AV
AVSC
AWG
BB
BC
BCT
BEP
BI
BLDG
BO
C
CL
CAB
CAN
CAT3
CAT5E
CAT6
CAT6A
CATV
CC
CO
COAX
COM
CON
CPU
CPV
CR
CT
CV
(D)
ABOVE COUNTER
ALTERNATING CURRENT ELECTRICAL GROUND
ACCESS CONTROL PANEL
ACCESS CONTROL SYSTEM
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
ASSISTED LISTENING SYSTEM
AUTOMATIC OPERATOR
AUTOMATIC OPENER CONTROLLER
ANGLE POLISHED CONNECTOR
AUDIO PATCH PANEL
APPROXIMATELY
AUXILIARY RELAY
ARCHITECTURAL
AUDIOVISUAL
AUDIOVISUAL SYSTEMS CONTRACTOR
AMERICAN WIRE GAUGE
BACKBONE
BELOW COUNTER
BONDING CONDUCTOR FOR TELECOMMUNICATIONS
BUILDING ENTRANCE PROTECTOR
BIOMETRIC INTERFACE
BUILDING
BY OTHERS
CONDUIT
CENTERLINE
CABINET
CONTROLLED AREA NETWORK
CATEGORY 3 COPPER CABLE
CATEGORY 5E COPPER CABLE
CATEGORY 6 COPPER CABLE
CATEGORY 6 AUGMENTED COPPER CABLE
CABLE TELEVISION
CLOSE CONTACT
CONDUIT ONLY (NO CABLE)
COAXIAL CABLE
COMMON
CONDUCTOR
COMPUTER PROCESSING UNIT
COMPONENT VIDEO
CARD READER
COUNT
COMPOSITE VIDEO
DEMOLISH
DB
DD
DEMARC
DIA
DNS
DPDT
DPS
DR
DVI
DWG
(E)
ECP
EEB
EF
EL
ELEC
ELR
EMT
ENCL
EQPMT
ER
ES
ESC
ESO
FACP
FB
FD
FLEX
FPA
FSD
FUT
G
HB
HC
HCS
HO
ID
IDF
IDS
IG
IMC
IP
IR
ISP
DATA GRADE COPPER BACKBONE
DEAD
DEMARCATION
DIAMETER
DATA NETWORK SWITCH
DOUBLE POLE, DOUBLE THROW
DOOR POSITION SWITCH
DOOR RELEASE
DIGITAL VIDEO INTERFACE
DRAWING
EXISTING
ELEVATOR CONTROL PANEL
EMERGENCY EXIT BUTTON
ENTRANCE FACILITY (DEMARC)
ELECTRIC LATCH
ELECTRICAL
ELECTRIC LATCH RETRACTION
ELECTRICAL METALLIC TUBING
ENCLOSURE (SPLICE)
EQUIPMENT
EQUIPMENT ROOM
ELECTRIC STRIKE
ELECTRICAL SYSTEMS CONTRACTOR
ELECTRIC SOLENOID
FIRE ALARM CONTROL PANEL
FIBER BACKBONE
FLOOR DISTRIBUTOR
FLEXIBLE
FLOOR PENETRATION ASSEMBLY
FIRE STOP DEVICE
FUTURE
GROUND
HANDICAP BUTTON
HEAT CONTAINMENT SYSTEM
HORIZONTAL CABLE
HOLD OPEN
INSIDE DIAMETER
INTERMEDIATE DISTRIBUTION FACILITY
INTRUSION DETECTION SYSTEM
ISOLATED GROUND
INTERMEDIATE METAL CONDUIT
INTERNET PROTOCOL
INFRARED
INSIDE PLANT
IT
LAN
LBS
LL
LM
LPS
LR
MAG
MECH
MFR
MIC
MIN
ML
MM
MREX
(NL)
NC
NO
NTS
NVR
OB
OC
OD
OFCI
OFOI
OHM
OPE
OR
OSP
P
PDS
PDU
POS
PP
PR
PS
PWR
(R)
(RL)
R
REV
REX
RF
RFG
RGB
INFORMATION TECHNOLOGY
LOCAL AREA NETWORK
LATCH BOLT SWITCH
LINE LEVEL LEFT CHANNEL AUDIO
LINE LEVEL MONO AUDIO
LOCK POWER SUPPLY
LINE LEVEL RIGHT CHANNEL AUDIO
MAGNETIC LOCK
MECHANICAL
MANUFACTURER
MICROPHONE (CONNECTION)
MINIMUM
MONITORED LATCH
MULTIMODE FIBER OPTIC CABLE
MOTION REQUEST TO EXIT
NEW LOCATION
NORMALLY CLOSED CONTACT
NORMALLY OPEN CONTACT
NOT TO SCALE
NETWORK VIDEO RECORDER
OVERRIDE BUTTON
ON CENTER
OUTSIDE DIAMETER
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
RESISTIVE NETWORK
OWNER PROVIDED EQUIPMENT
OPERATING ROOM
OUTSIDE PLANT
PROJECTOR
PROTECTIVE DISTRIBUTION SYSTEM
POWER DISTRIBUTION UNIT
POINT OF SALE
PATCH PANEL(S)
PAIR
POWER SUPPLY
POWER (SUPPLY)
REMOVE
REMOVE AND RELOCATE
RISER
REVISION
REQUEST TO EXIT SWITCH
RADIO FREQUENCY
RAISED FLOOR GROMMET
HIGH RESOLUTION VIDEO
RGBHV
RI
RM
RMC
RNC
S
SB
SC
SCHED
SCNS
SCPP
SCPS
SH
SM
SMR
SN
SP
SPEC
SPKR
SPR
SR
SSC
STP
SV
TB
TBB
TBD
TC
TGB
TMGB
TP
TR
TSC
TYP
UCV
UG
UPP
UPS
USB
V
VB
VLAN
VUTP
W
WAP
HIGH RESOLUTION ANALOG VIDEO
READER INTERFACE
ROOM
RIGID METALLIC CONDUIT
RIGID NONMETALLIC CONDUIT
STATION
SMART BOARD
SECURITY CAMERA
SCHEDULE
SECURITY CAMERA NETWORK SWITCH
SECURITY CAMERA PATCH PANEL
SECURITY CAMERA POWER SUPPLY
SURFACE HOUSING
SINGLEMODE FIBER OPTIC CABLE
SURFACE METAL RACEWAY
SERIAL NETWORK MODULE
SURGE PROTECTOR
SPECIFICATION
LOUDSPEAKER LEVEL AUDIO
SURFACE PLASTIC RACEWAY
SERVER ROOM
SECURITY SYSTEMS CONTRACTOR
SHIELDED TWISTED PAIR
S VIDEO
TERMINATION BLOCK(S)
TELECOMMUNICATIONS BONDING BACKBONE
TO BE DETERMINED
TELECOMMUNICATIONS CONTRACTOR
TELECOMMUNICATIONS GROUNDING BUSBAR
TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TWISTED PAIR
TELECOMMUNICATIONS ROOM
TELECOMMUNICATION SYSTEMS CONTRACTOR
TYPICAL
UNDERGROUND CABLE VAULT
UNDERGROUND
UNSHIELDED TWISTED PAIR PATCH PANEL
UNINTERRUPTIBLE POWER SUPPLY
UNIVERSAL SERIAL BUS
VOICE
VOICE GRADE COPPER BACKBONE
VIRTUAL LOCAL AREA NETWORK
VIDEO UNSHIELDED TWISTED PAIR CABLE
WALL MOUNTED
WIRELESS ACCESS POINT
S:\01_Projects\UCCS 11 001 UCCS_UniversityCenterAVIntegration\030 CAD\10 Masters\11 001 T0.01 TECHNOLOGY TITLE SHEET.dwg
mittjr
Feb.06.2012
8:50 am
ENTITY
EC
ELECTRICAL CONTRACTOR
TC
TELECOM CONTRACTOR
AC
AUDIOVISUAL CONTRACTOR
SC
SECURITY CONTRACTOR
GC
GENERAL CONTRACTOR
LC
LOW VOLTAGE/SPECIALTY CONTRACTOR
BO
BY OTHERS
O
Issue
OWNER
Date
Construction Documents 12/16/2011
DRAWING ANNOTATIONS
SYMBOL
DESCRIPTION
#
KEY NOTE
#
DRAWING NOTE
#
EQUIPMENT SCHEDULE NUMBER
#
REVISION NUMBER
SECTION OR ELEVATION TAG
*
SECTION OR ELEVATION LETTER
#
REFERENCE DRAWING NUMBER
*
#
REFERENCE TAG
*
REFERENCE LETTER
#
REFERENCE DRAWING NUMBER
*
#
A
D
*
#
C
B
ROOM WALL ELEVATION BUBBLE
*
REFERENCE NUMBER
#
REFERENCE DRAWING NUMBER
WALL ELEVATION REFERENCE
CONTINUATION LINE
EC AC
Client:
UCCS
Project #:
11 001
Drawn By:
JRM
Designed By:
DEB
Approved By:
JWT
FURNISH | INSTALL CALLOUT SEE SCHEDULE
Date:
12/16/2011
TELECOM AREA BOUNDARY LINE
Scale:
AS SHOWN
CONSTRUCTION DOCUMENTS
TECHNOLOGY
TITLE SHEET
Copyright 2011 Rimrock Group, Inc.
Copyright reserved. All parts of this drawing are the exclusive property of
Rimrock Group, Inc. and shall not be used or reproduced in any manner
without express written consent.
RIMROCK GROUP
Empowered Business 9 Quiet Technology
131B
A
AUDIOVISUAL CONTRACTOR (AVC) TO FIELD VERIFY PROJECTION
SCREEN SIZE, DIMENSIONS, AND LOCATION BASED ON SITE
CONDITIONS PRIOR TO SHOP SUBMITTAL, PROCUREMENT, AND
INSTALLATION. THE AVC SHALL ALSO VERIFY SCREEN SIZE, THOUGH
IN SOME CASES IT COULD BE PROVIDED AND/OR INSTALLED BY
OTHERS. IMMEDIATELY INFORM CONSULTANT OF ANY VARIANCES
REQUIRED TO THE SPECIFIED UNITS. THIS WOULD INCLUDE
DEFICIENCIES AND INCOMPATABILITIES WITH THE IMAGE SIZE,
PROJECTOR, AND OTHER AV ELECTRONIC EQUIPMENT
B
AUDIOVISUAL CONTRACTOR SHALL INSTALL EACH LOUDSPEAKER
WITH A SEISMIC RESTRAINING SYSTEM AS SPECIFIED BY LOCAL AND
STATE MANDATED LAWS
C
AUDIOVISUAL CONTRACTOR SHALL VERIFY AND COORDINATE
INFRASTRUCTURE (CONDUIT, BACK BOXES, ETC.) WITH EC PRIOR TO
THE COMPLETION OF THE ELECTRICAL ROUGH+IN. IMMEDIATELY
BRING DISCREPANCES TO THE ATTENTION OF THE ENGINEER
D
DRAWING ELEMENTS SHOWN IN GRAY ARE TO BE INSTALLED AS
PART OF A DIFFERENT BID PACKAGE OR ARE TO BE PROVIDED BY
OTHERS. WHERE SUCH ELEMENTS AFFECT THE CONTRACTORS
WORK, COORDINATE DEPENDENCIES WITH THE OTHER TRADES
AND/OR THE OWNER IN A TIMELY MANNER, BEFORE SUCH
DEPENDENCIES ARISE IN THE FIELD
E
DRAWINGS SHALL NOT BE SCALED FOR BOX, DEVICE, AND/OR
EQUIPMENT LOCATIONS. PRIOR TO ELECTRICAL ROUGH+IN, THE
CONTRACTOR SHALL COORDINATE DIMENSIONS, LOCATIONS,
LEVELS, AND MOUNTING HEIGHTS TO SUIT FIELD CONDITIONS AND
EQUIPMENT OPERATING PARAMETERS AND SHALL FURTHERMORE
COORDINATE WITH THE RELEVANT AND/OR AFFECTED TRADE(S).
WHERE COORDINATION DICTATES THAT FINAL LOCATIONS VARY
SIGNIFICANTLY FROM THAT SHOWN ON THE DRAWINGS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND AWAIT APPROVAL
PRIOR TO ELECTRICAL ROUGH+IN
F
PROJECTION SCREENS SHALL BE MOUNTED AS CLOSE TO CEILING
AS POSSIBLE. FOR NON+TENSION TAB SCREENS, PROVIDE REQUIRED
BLACK DROP MATERIAL TO EXTEND PROJECTION SCREEN TO 4+FEET
ABOVE FINISHED FLOOR. FOR TENSION TAB SCREENS, COORDINATE
SCREEN HEIGHT OFF FINISH FLOOR AND CORRESPONDING BLACK
DROP MATERIAL PRIOR TO PROCUREMENT
G
PROJECTION SCREENS SHALL BE MOUNTED AS CLOSE TO CEILING
AS POSSIBLE. PROVIDE REQUIRED BLACK MATERIAL TO EXTEND
PROJECTION SCREEN TO 4+FEET ABOVE FINISHED FLOOR
131A
135
133
UP
IF
IF
W2P
IF
010
IF
IF
W2A W2P
010
W2A W2P
1
2
T5.01
T5.01
TYP
TYP
124
122
120
CLYDE'S
IF
W2P
100H
119
UCCS
UNIVERSITY CENTER AV INTEGRATION
GENERAL NOTES
10807 New Allegiance Drive, Suite 400
Colorado Springs, CO 80921
Voice: (719) 53391112 9 Fax: (719) 53391113
info@rimrockgroup.com 9 www.rimrockgroup.com
KEY NOTES
SOME KEY NOTES BELOW MAY NOT APPEAR ON THIS SHEET
IF
OTA
IF
IF
W2P
W2B IF
2
IF
1
PROVIDE TYPICAL AUDIOVISUAL SYSTEM LAYOUT WITHIN THIS ROOM
WITH ADD ALTERNATE PRICING TO PROVIDE ROOM COMBINING
CAPABILITIES. SEE AUDIOVISUAL ONE+LINES FOR ADD ALTERNATE
INFORMATION
2
PROVIDE POWER RECEPTACLE WITHIN 3+FEET OF INTERFACE PLATE
W2P
010
010
W2A W2P
IF
IF
W2P W2A
126
S
S
S
S
1
1
116A
119A
116B
W2A W2P
S
S
S
S
IF
IF
010
A
W2P IF
100B
117
Issue
100C
Date
Construction Documents 12/16/2011
105G
S:\01_Projects\UCCS+11+001+UCCS_UniversityCenterAVIntegration\030+CAD\10+Masters\11+001 T2.01 FIRST FLOOR TECHNOLOGY PLAN.dwg
mittjr
Feb.06.2012
8:50 am
123
121
OTA
UP
101E
101D
115
5H
Client:
UCCS
Project #:
11+001
Drawn By:
JRM
Designed By:
DEB
Approved By:
JWT
Date:
12/16/2011
Scale:
AS SHOWN
N
1
FIRST FLOOR TECHNOLOGY PLAN
CONSTRUCTION DOCUMENTS
T2.01
8'
4'
0
1/8" = 1'+0"
8'
FIRST FLOOR
TECHNOLOGY
PLAN
Copyright 2011 Rimrock Group, Inc.
Copyright reserved. All parts of this drawing are the exclusive property of
Rimrock Group, Inc. and shall not be used or reproduced in any manner
without express written consent.
RIMROCK GROUP
Empowered Business 9 Quiet Technology
311A
313
312
314
300G
300D
306
311
A
AUDIOVISUAL CONTRACTOR (AVC) TO FIELD VERIFY PROJECTION
SCREEN SIZE, DIMENSIONS, AND LOCATION BASED ON SITE
CONDITIONS PRIOR TO SHOP SUBMITTAL, PROCUREMENT, AND
INSTALLATION. THE AVC SHALL ALSO VERIFY SCREEN SIZE, THOUGH
IN SOME CASES IT COULD BE PROVIDED AND/OR INSTALLED BY
OTHERS. IMMEDIATELY INFORM CONSULTANT OF ANY VARIANCES
REQUIRED TO THE SPECIFIED UNITS. THIS WOULD INCLUDE
DEFICIENCIES AND INCOMPATABILITIES WITH THE IMAGE SIZE,
PROJECTOR, AND OTHER AV ELECTRONIC EQUIPMENT
B
AUDIOVISUAL CONTRACTOR SHALL INSTALL EACH LOUDSPEAKER
WITH A SEISMIC RESTRAINING SYSTEM AS SPECIFIED BY LOCAL AND
STATE MANDATED LAWS
C
AUDIOVISUAL CONTRACTOR SHALL VERIFY AND COORDINATE
INFRASTRUCTURE (CONDUIT, BACK BOXES, ETC.) WITH EC PRIOR TO
THE COMPLETION OF THE ELECTRICAL ROUGH*IN. IMMEDIATELY
BRING DISCREPANCES TO THE ATTENTION OF THE ENGINEER
D
DRAWING ELEMENTS SHOWN IN GRAY ARE TO BE INSTALLED AS
PART OF A DIFFERENT BID PACKAGE OR ARE TO BE PROVIDED BY
OTHERS. WHERE SUCH ELEMENTS AFFECT THE CONTRACTORS
WORK, COORDINATE DEPENDENCIES WITH THE OTHER TRADES
AND/OR THE OWNER IN A TIMELY MANNER, BEFORE SUCH
DEPENDENCIES ARISE IN THE FIELD
E
DRAWINGS SHALL NOT BE SCALED FOR BOX, DEVICE, AND/OR
EQUIPMENT LOCATIONS. PRIOR TO ELECTRICAL ROUGH*IN, THE
CONTRACTOR SHALL COORDINATE DIMENSIONS, LOCATIONS,
LEVELS, AND MOUNTING HEIGHTS TO SUIT FIELD CONDITIONS AND
EQUIPMENT OPERATING PARAMETERS AND SHALL FURTHERMORE
COORDINATE WITH THE RELEVANT AND/OR AFFECTED TRADE(S).
WHERE COORDINATION DICTATES THAT FINAL LOCATIONS VARY
SIGNIFICANTLY FROM THAT SHOWN ON THE DRAWINGS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND AWAIT APPROVAL
PRIOR TO ELECTRICAL ROUGH*IN
F
PROJECTION SCREENS SHALL BE MOUNTED AS CLOSE TO CEILING
AS POSSIBLE. FOR NON*TENSION TAB SCREENS, PROVIDE REQUIRED
BLACK DROP MATERIAL TO EXTEND PROJECTION SCREEN TO 4*FEET
ABOVE FINISHED FLOOR. FOR TENSION TAB SCREENS, COORDINATE
SCREEN HEIGHT OFF FINISH FLOOR AND CORRESPONDING BLACK
DROP MATERIAL PRIOR TO PROCUREMENT
G
PROJECTION SCREENS SHALL BE MOUNTED AS CLOSE TO CEILING
AS POSSIBLE. PROVIDE REQUIRED BLACK MATERIAL TO EXTEND
PROJECTION SCREEN TO 4*FEET ABOVE FINISHED FLOOR
DN
310
310A
300F
W2P
IF
010
IF
IF
W2P W2A
2
1
T5.01
T5.01
TYP
TYP
UCCS
UNIVERSITY CENTER AV INTEGRATION
GENERAL NOTES
10807 New Allegiance Drive, Suite 400
Colorado Springs, CO 80921
Voice: (719) 53391112 9 Fax: (719) 53391113
info@rimrockgroup.com 9 www.rimrockgroup.com
309
KEY NOTES
304
SOME KEY NOTES BELOW MAY NOT APPEAR ON THIS SHEET
OTA
UC THEATER
1
PROVIDE TYPICAL AUDIOVISUAL SYSTEM LAYOUT WITHIN THIS ROOM
WITH ADD ALTERNATE PRICING TO PROVIDE ROOM COMBINING
CAPABILITIES. SEE AUDIOVISUAL ONE*LINES FOR ADD ALTERNATE
INFORMATION
2
PROVIDE POWER RECEPTACLE WITHIN 3*FEET OF INTERFACE PLATE
302
DRAWING NOTES
UP
1
307
DISPLAY TO BE MOUNTED ON ARTICULATING ARM
W2P W2A
010
IF
IF
W2P IF
IF
W2P
2
IF
IF
V
W2P
W3B
010
IF
IF
1
IF
1
IF
W2P W2A W3A
3
315
010
IF
316
W2A W2P
S
S
S
S
T5.01
1
1
303A
303B
301
S
S
S
S
Issue
300B
Date
Construction Documents 12/16/2011
300C
S:\01_Projects\UCCS*11*001*UCCS_UniversityCenterAVIntegration\030*CAD\10*Masters\11*001 T2.03 THIRD FLOOR TECHNOLOGY PLAN.dwg
mittjr
Feb.06.2012
8:50 am
300
300A
DN
Client:
UCCS
Project #:
11*001
Drawn By:
JRM
Designed By:
DEB
Approved By:
JWT
Date:
12/16/2011
Scale:
AS SHOWN
CONSTRUCTION DOCUMENTS
N
1
THIRD FLOOR TECHNOLOGY PLAN
T2.03
8'
4'
0
1/8" = 1'*0"
THIRD FLOOR
TECHNOLOGY
PLAN
8'
Copyright 2011 Rimrock Group, Inc.
Copyright reserved. All parts of this drawing are the exclusive property of
Rimrock Group, Inc. and shall not be used or reproduced in any manner
without express written consent.
RIMROCK GROUP
Empowered Business 9 Quiet Technology
10807 New Allegiance Drive, Suite 400
Colorado Springs, CO 80921
Voice: (719) 53391112 9 Fax: (719) 53391113
info@rimrockgroup.com 9 www.rimrockgroup.com
GENERAL NOTES
A
EQUIPMENT SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY.
PROVIDE QUANTITIES AS SHOWN ELSEWHERE ON THE DRAWINGS,
AS CALLED FOR IN THE SPECIFICATIONS, AND/OR AS NECESSARY
FOR A FULLY FUNCTIONAL AND OPERATING SYSTEM(S) READY FOR
THE OWNERS USE
B
ALL POWER REQUIREMENTS INCLUDING BUT NOT LIMITED TO POWER
SUPPLIES, POWER DISTRIBUTION AND POWER CORDS ARE TO BE
PROVIDED BY CONTRACTOR UNLESS NOTED OTHERWISE. POWER
REQUIREMENTS ARE ASSUMED AND MAY NOT BE SHOWN HEREIN
C
DATA PATCH CABLES REQUIRED TO CONNECT A DEVICE TO A DATA
NETWORK OUTLET SHALL BE PROVIDED BY THE CONTRACTOR
D
THE CONTRACTOR(S) SHALL PROVIDE ALL REQUIREMENTS SHOWN IN
BLACK; THIS IS TO INCLUDE BUT NOT LIMITED TO DEVICES, CABLING,
TERMINATIONS AND PROGRAMMING. DEVICES SHOWN IN GRAY
INDICATE REQUIREMENTS THAT ARE EITHER EXISTING AND/OR
PROVIDED BY OTHERS
E
SOME ANCILLARY EQUIPMENT IS SHOWN HEREIN FOR CLARITY BUT
NOT ALL ANCILLARY EQUIPMENT IS SHOWN WITHIN THIS DRAWING.
REFER TO EQUIPMENT SCHEDULES FOR EQUIPMENT
REQUIREMENTS. PROVIDE AUXILIARY EQUIPMENT AS REQUIRED TO
PROVIDE A FULLY FUNCTIONAL AND OPERATING SYSTEM READY FOR
THE OWNERS USE
F
SOME TRANSMISSION EXTENSION EQUIPMENT IS SHOWN HEREIN
FOR CLARITY BUT NOT ALL TRANSMISSION EXTENSION EQUIPMENT
MAY BE SHOWN WITHIN THIS DRAWING. TRANSMISSION EXTENSION
EQUIPMENT SHALL INCLUDE BUT NOT LIMITED TO EXTENDERS,
AMPLIFIERS AND/OR SIGNAL REPEATERS. PROVIDE TRANSMISSION
EXTENSION EQUIPMENT AS REQUIRED TO PROVIDE A FULLY
FUNCTIONAL AND OPERATING SYSTEM READY FOR THE OWNERS
USE
G
PROVIDE HDMI TRANSMISSION EQUIPMENT AS REQUIRED TO
PROVIDE A FULLY FUNCTIONAL AND OPERATING SYSTEM READY FOR
THE OWNERS USE. HDMI TRANSMISSION EQUIPMENT SHALL INCLUDE
BUT NOT BE LIMITED TO SPECIALIZED CABLE, CATEGORY CABLE
TRANSMITTERS/RECEIVERS AND/OR FIBER CABLE
TRANSMITTERS/RECEIVERS
CV
HDMI
LAPTOP
(BY OTHERS)
RGB
RGB
LL+LR
LL+LR
FLAT PANEL
VIDEO DISPLAY
AND MOUNT
A27291
OR
A27292
IF W2A
BLU&RAY DVD
(OFCI)
HDMI
HDMI
IF W2P
1
SINGLE DISPLAY ROOM AUDIOVISUAL ONE&LINE DIAGRAM
T4.01
UCCS
UNIVERSITY CENTER AV INTEGRATION
LL+LR
DRAWING NOTES
HDMI
HDMI
CV
CV
LL
LL
LR
LR
HDMI
RGB
LL+LR
RGB
LL+LR
IF W2A
RGB
HDMI
HD SCALER
A22560
IF W2P
VIDEO DISPLAY
A27291
LL+LR
IF W2A
HDMI
[ 2V1 ]
HDMI
HD SCALER
A22560
IF W2P
BLU&RAY
PLAYER
(OFCI)
IF W2P
EQUIPMENT RACK WALL
A51245
3
UTILIZE PRE&AMP
[ 2V1 ]
HDMI
[ 2V2 ]
[ 2V3 ]
RGB
[ 2V4 ]
IF W2P
AUDIO
AMPLIFIER
A14330
SPKR
IF W2P
70V
8W
CEILING
LOUDSPEAKER
A15120
EQUIPMENT RACK WALL
A51245
RGB
EQUIPMENT RACK WALL
A51245
2
RGB
DRAWING FLOOR PLANS DEPICT ACTUAL NUMBER OF SPEAKERS
70V
8W
IF W2P
[ 2V4 ]
IF W2P
IF W2B
HDMI
RGB
[ 2V3 ]
VIDEO
DISTRIBUTION
AMPLIFIER
A22160
2
HDMI
[ 2V2 ]
HDMI
HDMI
LOCATE DEVICES BEHIND VIDEO DISPLAYS
VIDEO DISPLAY
A27291
MIC
BLU&RAY
PLAYER
(OFCI)
HDMI
DISTRIBUTION
AMPLIFIER
A22365
1
IF W2P
CEILING
LOUDSPEAKER
A15120
ADD ALTERNATE AUDIOVISUAL ONE&LINE DIAGRAM FOR COMBINED ROOMS 116A AND 116B
T4.01
HDMI
HDMI
CV
CV
LL
HDMI
[ 3V5 ]
HDMI
LL
LR
LR
RGB
RGB
LL+LR
IF W2A
RGB
HDMI
HD SCALER
A22560
IF W2P
HDMI
[ 3V1 ]
BLU&RAY
PLAYER
(OFCI)
S:\01_Projects\UCCS&11&001&UCCS_UniversityCenterAVIntegration\030&CAD\10&Masters\11&001 T4.01 TECHNOLOGY ONE&LINES.dwg
mittjr
Feb.06.2012
8:51 am
LL+LR
IF W2A
HDMI
HD SCALER
A22560
IF W2P
BLU&RAY
PLAYER
(OFCI)
IF W2P
RGB
MIC
HDMI
IF W3B
VIDEO
DISTRIBUTION
AMPLIFIER
A22160
RGB
HDMI
RGB
[ 3V1 ]
Issue
[ 3V2 ]
Date
Construction Documents 12/16/2011
[ 3V3 ]
[ 3V4 ]
RGB
EQUIPMENT RACK WALL
A51245
IF W2P
HDMI
[ 3A1 ]
LL+LR
HDMI
CC
CV
LR
PROJECTION
SCREEN
A33300
SCREEN
SWITCH
LL
PROJECTOR
A28027
LL+LR
IF W2P
AUDIO
AMPLIFIER
A14330
LL+LR
[ 3V5 ]
CC
SPKR
LM
MICROPHONE/
LINE AUDIO
MIXER
A13600
IF W2P
[ 3V4 ]
IF W2P
LL+LR
VIDEO DISPLAY
A27291
HDMI
HDMI
[ 3V2 ]
HDMI
[ 3V3 ]
EQUIPMENT RACK WALL
A51245
VIDEO DISPLAY
A27291
HDMI
DISTRIBUTION
AMPLIFIER
A22365
[ 3A1 ]
EQUIPMENT RACK WALL
A51245
IF W2P
VOLUME
CONTROL
A15000
70V
8W
CEILING
LOUDSPEAKER
A15120
70V
8W
CEILING
LOUDSPEAKER
A15120
Client:
UCCS
Project #:
11&001
Drawn By:
JRM
Designed By:
DEB
Approved By:
JWT
Date:
12/16/2011
Scale:
AS SHOWN
RGB
LL+LR
CONSTRUCTION DOCUMENTS
IF W3A
TECHNOLOGY
ONE&LINES
3
ADD ALTERNATE AUDIOVISUAL ONE&LINE DIAGRAM FOR COMBINED ROOMS 303A AND 303B
T4.01
Copyright 2011 Rimrock Group, Inc.
Copyright reserved. All parts of this drawing are the exclusive property of
Rimrock Group, Inc. and shall not be used or reproduced in any manner
without express written consent.
RIMROCK GROUP
Empowered Business 9 Quiet Technology
10807 New Allegiance Drive, Suite 400
Colorado Springs, CO 80921
Voice: (719) 53391112 9 Fax: (719) 53391113
info@rimrockgroup.com 9 www.rimrockgroup.com
4 11/16" x 4 11/16" DEVICE BOX
WITH 1 GANG MUD RING
(TELECOM)
WALL STUDS
TO ACCESSIBLE
CEILING SPACE
FINISHED CEILING
FRONT
POWER CONDUIT
REQUIREMENTS
(MIN. 3/4")
(1) 1"
CONDUIT
DUPLEX POWER OUTLET
EC EC
CL
FINISHED CEILING
(2) 1 1/4" FLEX
CONDUITS
(2) 1 1/4" FLEX
CONDUITS
EC EC
EC EC
ELECTRICAL
RECEPTACLE
ELECTRICAL
CONDUIT
EC EC
FLAT PANEL
DISPLAY
AC AC
TOP VIEW
FLAT PANEL DISPLAY
WALL MOUNT
ELECTRICAL CONTRACTOR TO PROVIDE STRUCTURAL
SUPPORT FOR PROJECTORS. COORDINATE WITH AV
CONTRACTOR FOR LOCATION
EC EC
CL
AV CABLING
EC EC
EC EC
TELECOM
OUTLET
2)GANG DEEP
CUT IN BOX W2P
THREADED ROD
#
POWER CONDUIT
REQUIREMENTS
(MIN. 3/4")
VARIES
EC EC
10" (TYP)
ATTACH TO
STRUCTURE
(1) 1 1/4" FLEX
CONDUIT
AC AC
3'
ATTACH TO
STRUCTURE
DUPLEX POWER
RECEPTACLE (TYP)
NOT USED
SCALE: NONE
AV INTERFACE W2A,
2)GANG DEEP CUT IN BOX
EC EC
UNISTRUT
UCCS
UNIVERSITY CENTER AV INTEGRATION
PROJECTOR
POLE MOUNT
TO CABLE
TRAY
TO ACCESSIBLE
CEILING SPACE
EC EC
VARIES
ELECTRICAL
CONTRACTOR TO
PROVIDE 2' x 3'
UNISTRUT
RECTANGLE
(2) 1 1/4" FLEX
CONDUITS
8"
EC EC
CONDUITS
DEVICE
BOXES
16" OC
48" AFF
CEILING
AV FEED)THRU W2P,
2)GANG DEEP CUT IN BOX
VARIES
EC EC
AUDIOVISUAL
WALL RACK
PROJECTOR POLE MOUNT
AC AC
SECURITY PROJECTOR
MOUNT
30 1/2" AFF
FINISHED FLOOR
PROJECTOR
FRONT
FINISHED FLOOR
NOTES:
1.
EXISTING WALL STUDS LOCATED WITHIN INTERSTITIAL WALL SPACE. CENTER WALL STUDS ON DISPLAY LOCATION
2.
DEVICE BOX AND CONDUIT LOCATIONS MAY VARY DUE TO FIELD CONDITIONS
3.
CENTERLINE IS DENOTED FOR DEVICE BOXES AND NOT VIDEO DISPLAY MOUNT. CONTRACTOR SHALL LOCATE
MOUNT AS REQUIRED TO PROVIDE BOTTOM OF SCREEN HEIGHT
NOTES:
SIDE VIEW
NOTES:
1.
#
NOT USED
SCALE: NONE
UTILIZE FLEX CONDUIT AT DEVICE BOXES WITHIN REMOVABLE CEILING TILE.
PROVIDE 3)FEET OF MOVEMENT FROM CENTER OF UNISTRUT SUPPORT
TYPICAL PROJECTOR MOUNT DETAIL
4
2
SCALE: NONE
TYPICAL DISPLAY MOUNT DETAIL
1
SCALE: NONE
1.
COORDINATE POWER AND COMMUNICATION BOX LOCATIONS WITH AUDIOVISUAL CONTRACTOR
2.
SUPPORT RACK FROM EXISTING WALL STUDS
TYPICAL WALL RACK MOUNT DETAIL
SCALE: NONE
TO ACCESSIBLE
CEILING SPACE
FINISHED CEILING
PROJECTION
SCREEN HOUSING
(2) 1 1/4" FLEX
CONDUITS
EC EC
(2) 1 1/4" FLEX
CONDUITS
3/4" CONDUIT
FOR POWER
EC EC
Issue
(1) 1 1/4" FLEX
CONDUIT
Date
Construction Documents 12/16/2011
EC EC
POWER CONDUIT
REQUIREMENTS
(MIN. 3/4")
TELECOM
OUTLET
EC EC
EC EC
#
NOT USED
DUPLEX POWER
RECEPTACLE (TYP)
3/8" THREADED ROD
SCALE: NONE
EC EC
AV INTERFACE W3A,
3)GANG DEEP CUT IN BOX
EC EC
AV INTERFACE W2A,
2)GANG DEEP CUT IN BOX
EC EC
#
NOT USED
#
SCALE: NONE
NOT USED
SCALE: NONE
FLUSH TO FINISHED
SIDE OF CEILING
POWER CONDUIT
REQUIREMENTS
(MIN. 3/4")
S:\01_Projects\UCCS)11)001)UCCS_UniversityCenterAVIntegration\030)CAD\10)Masters\11)001 T5.01 TECHNOLOGY DETAILS.dwg
mittjr
Feb.06.2012
8:51 am
CEILING
(2) 1 1/4" FLEX
CONDUITS
EC EC
GENERAL NOTES
EC EC
A
AV FEED)THRU W2P,
2)GANG DEEP CUT IN BOX
EC EC
AUDIOVISUAL
WALL RACK
B
AC AC
30 1/2" AFF
FINISHED FLOOR
NOTES:
NOTES:
1.
2.
#
NOT USED
SCALE: NONE
5
PROJECTION SCREEN HOUSING FURNISHED BY AUDIOVISUAL CONTRACTOR, INSTALLED BY
ELECTRICAL CONTRACTOR
1.
COORDINATE POWER AND COMMUNICATION BOX LOCATIONS WITH AUDIOVISUAL CONTRACTOR
ELECTRICAL CONTRACTOR TO HARD WIRE POWER TO PROJECTION SCREEN
2.
SUPPORT RACK FROM EXISTING WALL STUDS
CEILING MOUNTED ELECTRIC SCREEN DETAIL
SCALE: NONE
3
DRAWING ELEMENTS SHOWN IN GRAY ARE EXISTING OR ARE TO BE
PROVIDED BY OTHERS. WHERE SUCH ELEMENTS AFFECT THE
CONTRACTOR'S WORK, COORDINATE DEPENDENCIES WITH THE
OTHER TRADES AND/OR THE OWNER IN A TIMELY MANNER BEFORE
SUCH DEPENDENCIES ARISE
THE WORK DETAILED ON THIS SHEET MAY BE DEPENDENT UPON
AND/OR MAY AFFECT THE THE WORK OF THE OTHER TRADES. THE
CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING COORDINATION
ISSUES AND DEPENDENCIES BEFORE THEY ARISE. CHANGES
NECESSITATED BY THE FAILURE OF THE CONTRACTOR TO
COORDINATE WITH OTHER TRADES SHALL BE MADE AT NO
ADDITIONAL COST TO THE OWNER
Client:
UCCS
Project #:
11)001
Drawn By:
JRM
Designed By:
DEB
Approved By:
JWT
Date:
12/16/2011
Scale:
AS SHOWN
CONSTRUCTION DOCUMENTS
TECHNOLOGY
DETAILS
WALL RACK MOUNT DETAIL ) ROOM 303A
SCALE: NONE
Copyright 2011 Rimrock Group, Inc.
Copyright reserved. All parts of this drawing are the exclusive property of
Rimrock Group, Inc. and shall not be used or reproduced in any manner
without express written consent.