1 Re: 25 ½ Cragmoor Village Drive (Studio) Colorado Springs CO

advertisement
Page 1 of 4
1804 W. Colorado Avenue Colorado Springs CO 80904
719-473-2311 Fax 719-473-2312
AlpineConsultInc.com
Re: 25 ½ Cragmoor Village Drive (Studio) Colorado Springs CO
ACI Job: 33041
Date of Inspection: February 17, 2014
This Renovation/Demolition Inspection and Sampling were conducted in general
accordance with the sampling protocols established by 40 CFR 763 and Regulation 8.
Our Inspection and Sampling activities began with a visual observation of the interior and
exterior of the building to identify homogeneous areas of suspect Asbestos Containing
Material (ACM). Refer to Diagram(s) associated with this Inspection.
A physical assessment of each homogeneous area of suspect ACM was conducted to
assess the general condition of the material and determine the friability of the material.
The bulk samples were submitted under proper Chain of Custody procedures to Crisp
Analytical, L.L.C. Dallas NVLAB Code 200349-0
Kurt J. Olson - Inspector/Management Planner
State of Colorado, Asbestos Certification No. 1820
Page 2 of 4
DEMOLITION INSPECTION
BULK ASBESTOS ANALYSIS RESULTS
CLIENT: University of Colorado at Colorado Springs
INSPECTION LOCATION: 25 ½ Cragmoor Village Drive, Colorado
Springs CO
ACI JOB#: 33041
SAMPLE
ID
25-1
25-2
25-3
25-4
25-5
25-6
25-7
MATERIAL DESCRIPTION
and
CLASSIFICATION
Exterior Stucco – SM
Exterior Stucco – SM
Exterior Stucco – SM
Interior Stucco – SM
Interior Stucco – SM
Interior Stucco – SM
Roofing - All Layers - MM
SAMPLE LOCATION
Exterior Walls – See Diagram
Exterior Walls – See Diagram
Exterior Walls – See Diagram
East Wall
South Wall
West Wall
Roof
BILLING ADDRESS: University of Colorado – Procurement Service
Center, 1800 Grant Street Suite 500, Denver CO 80203-1145
DATE SAMPLED: February 17, 2014
DATE ANALYZED: February 20, 2014
ASBESTOS
CONTENT
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
None Detected
FRIABLE (F) or
NON-FRIABLE (NF)
MATERIAL
ASSESSMENT/
CATEGORY
ESTIMATED
QUANTITY
SQ FT
NF
NF
NF
NF
NF
NF
F
2
2
2
2
2
2
5
<1000
<1000
<1000
<1000
<1000
<1000
<1000
BULK ASBESTOS ANALYSIS RESULTS CONTINUED ON PAGE 3 OF 4
Page 3 of 4
BULK ASBESTOS ANALYSIS RESULTS
(CONTINUED)
CLIENT: University of Colorado at Colorado Springs
INSPECTION LOCATION: 9 Cragmoor Village Drive, Colorado
Springs CO
ACI JOB#: 33042
MATERIAL CLASSIFICATION:



BILLING ADDRESS: University of Colorado – Procurement Service
Center, 1800 Grant Street Suite 500, Denver CO 80203-1145
DATE SAMPLED: February 17, 2014
DATE ANALYZED: February 20, 2014
MATERIAL ASSESSMENT/CATEGORY
SM: Surface Material
MM: Miscellaneous Material
TSI: Thermal System Insulation







1. Damaged or Significantly Damaged Thermal System
Insulation
2. Damaged Friable Surfacing ACM
3. Significantly Damaged Friable Surfacing ACM
4. Damaged or Significantly Damaged Friable
Miscellaneous ACM
5. ACBM with Potential for Damage
6. ACBM with Potential for Significant Damage
7. Any Remaining Friable ACBM or Friable Suspected
ACBM
Samples are only indicative of conditions at the time of sample collection.
Alpine Consulting, Inc.
Asbestos Consulting Firm
State of Colorado, Registration No. ACF – 13820
Kurt J. Olson - Inspector/Management Planner
State of Colorado, Asbestos Certification No. 1820
Materials Characterization – Bulk Asbestos Analysis completed by Crisp Analytical, L.L.C.
Dallas NVLAP Lab Code 200349-0 TEM/PLM EPA H2O TX 01402 TDH 30-0235
AIHA LAP, LLC Laboratory # 102929
Page 4 of 4
CLIENT: University of Colorado at Colorado Springs
INSPECTION LOCATION: 9 Cragmoor Village Drive, Colorado
Springs CO
ACI JOB#: 33042
BILLING ADDRESS: University of Colorado – Procurement
Service Center, 1800 Grant Street Suite 500, Denver CO 80203-1145
DATE SAMPLED: February 17, 2014
DATE ANALYZED: February 20, 2014
DIAGRAM
2
5
1
3
4
7
North
6