Page 1 of 4 1804 W. Colorado Avenue Colorado Springs CO 80904 719-473-2311 Fax 719-473-2312 AlpineConsultInc.com Re: 25 ½ Cragmoor Village Drive (Studio) Colorado Springs CO ACI Job: 33041 Date of Inspection: February 17, 2014 This Renovation/Demolition Inspection and Sampling were conducted in general accordance with the sampling protocols established by 40 CFR 763 and Regulation 8. Our Inspection and Sampling activities began with a visual observation of the interior and exterior of the building to identify homogeneous areas of suspect Asbestos Containing Material (ACM). Refer to Diagram(s) associated with this Inspection. A physical assessment of each homogeneous area of suspect ACM was conducted to assess the general condition of the material and determine the friability of the material. The bulk samples were submitted under proper Chain of Custody procedures to Crisp Analytical, L.L.C. Dallas NVLAB Code 200349-0 Kurt J. Olson - Inspector/Management Planner State of Colorado, Asbestos Certification No. 1820 Page 2 of 4 DEMOLITION INSPECTION BULK ASBESTOS ANALYSIS RESULTS CLIENT: University of Colorado at Colorado Springs INSPECTION LOCATION: 25 ½ Cragmoor Village Drive, Colorado Springs CO ACI JOB#: 33041 SAMPLE ID 25-1 25-2 25-3 25-4 25-5 25-6 25-7 MATERIAL DESCRIPTION and CLASSIFICATION Exterior Stucco – SM Exterior Stucco – SM Exterior Stucco – SM Interior Stucco – SM Interior Stucco – SM Interior Stucco – SM Roofing - All Layers - MM SAMPLE LOCATION Exterior Walls – See Diagram Exterior Walls – See Diagram Exterior Walls – See Diagram East Wall South Wall West Wall Roof BILLING ADDRESS: University of Colorado – Procurement Service Center, 1800 Grant Street Suite 500, Denver CO 80203-1145 DATE SAMPLED: February 17, 2014 DATE ANALYZED: February 20, 2014 ASBESTOS CONTENT None Detected None Detected None Detected None Detected None Detected None Detected None Detected FRIABLE (F) or NON-FRIABLE (NF) MATERIAL ASSESSMENT/ CATEGORY ESTIMATED QUANTITY SQ FT NF NF NF NF NF NF F 2 2 2 2 2 2 5 <1000 <1000 <1000 <1000 <1000 <1000 <1000 BULK ASBESTOS ANALYSIS RESULTS CONTINUED ON PAGE 3 OF 4 Page 3 of 4 BULK ASBESTOS ANALYSIS RESULTS (CONTINUED) CLIENT: University of Colorado at Colorado Springs INSPECTION LOCATION: 9 Cragmoor Village Drive, Colorado Springs CO ACI JOB#: 33042 MATERIAL CLASSIFICATION: BILLING ADDRESS: University of Colorado – Procurement Service Center, 1800 Grant Street Suite 500, Denver CO 80203-1145 DATE SAMPLED: February 17, 2014 DATE ANALYZED: February 20, 2014 MATERIAL ASSESSMENT/CATEGORY SM: Surface Material MM: Miscellaneous Material TSI: Thermal System Insulation 1. Damaged or Significantly Damaged Thermal System Insulation 2. Damaged Friable Surfacing ACM 3. Significantly Damaged Friable Surfacing ACM 4. Damaged or Significantly Damaged Friable Miscellaneous ACM 5. ACBM with Potential for Damage 6. ACBM with Potential for Significant Damage 7. Any Remaining Friable ACBM or Friable Suspected ACBM Samples are only indicative of conditions at the time of sample collection. Alpine Consulting, Inc. Asbestos Consulting Firm State of Colorado, Registration No. ACF – 13820 Kurt J. Olson - Inspector/Management Planner State of Colorado, Asbestos Certification No. 1820 Materials Characterization – Bulk Asbestos Analysis completed by Crisp Analytical, L.L.C. Dallas NVLAP Lab Code 200349-0 TEM/PLM EPA H2O TX 01402 TDH 30-0235 AIHA LAP, LLC Laboratory # 102929 Page 4 of 4 CLIENT: University of Colorado at Colorado Springs INSPECTION LOCATION: 9 Cragmoor Village Drive, Colorado Springs CO ACI JOB#: 33042 BILLING ADDRESS: University of Colorado – Procurement Service Center, 1800 Grant Street Suite 500, Denver CO 80203-1145 DATE SAMPLED: February 17, 2014 DATE ANALYZED: February 20, 2014 DIAGRAM 2 5 1 3 4 7 North 6