Respond & Achieve Hytera Patrol System Tutorial www.hytera.com 01 03 System Overview System Config 02 04 Network Structure Software Installation 01 System Overview System Overview Receiving Station: A repeater (RD62X/RD96X/RD98X/RD98XS) or a mobile radio (only MD78X) can work as a patrol data receiving station. System Components Item Power Supply Working Temperature Frequency Valid Distance Patroller ID Card No extra power supply -22~55℃ 13.56~14.2Mhz 3 cm Patrol Checkpoint No extra power supply -40~85 ℃ 13.56~14.2Mhz 4 cm UHF: 400-470Mhz 4W(High); 1W(Low) VHF: 136-174Mhz 5W(High); 1W(Low) 16 Hours (1500mAh); 22 Hours (2000mAh) U.S.A Military Standard & IP54 Analog & Digital auto detect PD41X Patrol Radio Embedded RFID Up to 250 pieces of offline data could be stored 02 Network Structure Single Site Solution Multi-sites Solution 03 System Config Mobile Receiving Station Config Forward To PC Step 1 Go to “Conventional -> General Setting -> Network” from the left navigation tree of CPS. Step 2 Select Forward To PC in Radio to PC Network interface. Mobile Receiving Station Config Channel Configuration Step 1 Go to “Conventional -> Channel -> Digital Channel” from the left navigation tree of CPS,right click Digital Channel and select Add to add a new digital channel. Mobile Receiving Station Config Channel Configuration (Continued) Step 2 Double-click the new digital channel to enter the configuration interface. Configure the channel alias per configuration planning and select a slot (etc. Slot1) in Slot Operation. Set the Receive Frequency and Transmit Frequency. Mobile Receiving Station Config Channel Configuration (with Pseudo Trunk feature) If Mobile Radio Receiving Station Solution uses only one frequency, the Pseudo Trunk feature must be enabled; the slot for patrolling services must be different from the slot for voice communication; RX Group List and TX Contact must be set to None. Mobile Receiving Station Config Radio ID Go to “Conventional -> DMR Services -> Basic” or “Conventional -> Digital Common -> Basic” to set the Radio ID of the Mobile Radio Receiving Station. Mobile Receiving Station Config TMS Port Go to “Conventional -> General Setting -> Network -> Radio Services” and set “TMS Port” to “5016”. Repeater Configuration Single site Network Step 1 Go to “Conventional -> General Setting -> Network” from the left navigation tree of CPS and configure the following parameters. Repeater Configuration Single site Network (Continued) Step 2 Select “Single Site” for local operation Step 3 Click “Forward to PC” Step 4 Enter the client computer IP address into “Third Party Server IP”. Repeater Configuration Multi-sites IP Connection (Master) Step 1 Go to “Conventional -> General Setting -> Network” from the left navigation tree of CPS and configure the following parameters.”. Repeater Configuration Multi-sites IP Connection (Master) Step 2 Select “Master”. The repeater will operate locally; it will not send data to other repeaters; patrol data will be uploaded to the client. Repeater Configuration Multi-sites IP Connection (Slave) Step 1 Set repeater IP address into the same LAN of Third Party Server IP. Repeater Configuration Multi-sites IP Connection (Slave) Step 2 Select “Slave”. The repeater will send patrol data to “Master” via Ethernet. Notice: Unclick “Forward to PC” box of “Slave” repeater. Repeater Configuration Channel Configuration Step 1 Go to “Conventional -> Channel -> Digital Channel” from the left navigation tree of CPS,right click Digital Channel and select Add to add a new digital channel. Repeater Configuration Channel Configuration (Continued) Step 2 Double-click the new digital channel to enter the configuration interface. Configure the channel alias per configuration planning and select a slot (etc. Slot1) in Slot Operation.. Notice: If the voice service and patrolling service shares the same frequency, different slots must be used. For example, the patrolling service uses slot 1 while the voice service uses slot 2 Repeater Configuration Channel Configuration (Continued) Step 3 Go to “Conventional -> Zone” from the left navigation tree of the CPS, select the “Digital patrol channel” and click “Add” to add it to the last channel in “Member” list. Repeater Configuration Radio ID Go to “Conventional -> DMR Services -> Basic” or “Conventional -> Digital Common -> Basic” to set the Radio ID of the Mobile Radio Receiving Station. Portable Radio Configuration Radio Contact Go to “Conventional -> DMR Services -> Contact” from the left navigation tree of the CPS, add the Alias and ID of the repeater or Mobile Radio Receiving Station into the list and set the Call Type to Private Call. Portable Radio Configuration Channel Configuration Step 1 The necessary parameters need to configure including: “Slot Operation”, “Receive Frequency”, “Transmit Frequency” and “Tx Contact Name” . The Tx admit of patrolling service channel should be set to “Channel Free”; “TDMA Direct Mode” must be selected. Portable Radio Configuration Channel Configuration (Continued) Step 2 Go to “Zone -> Zone 1” from the left navigation tree of the CPS, select the Digital patrol channel and click “Add” to add it to the last channel in Zone 1. Notice: For Patrol Management System, the patrolling data of patrol portable radios are automatically switched and transmitted in the last digital channel of the current zone by default. Otherwise, the patrolling data cannot be uploaded successfully Portable Radio Configuration Patrol Emergency Go to “General Setting -> Buttons” from the left navigation tree of the CPS, select Patrol Emergency from the drop down list for SK1 or SK2 In case of emergency during patrolling, the patroller can press the programmed Patrol Emergency key to trigger the emergency alarm. Portable Radio Configuration Patrol Resend Go to “General Setting -> Buttons” from the left navigation tree of the CPS, select Patrol Resend from the drop down list for SK1 or SK2. In case of patrol data uploading failure during patrolling, the patroller can press the programmed Patrol Resend key to resend the data. 04 Software Installation Software Installation Hardware Devices Requirements Downloading and Unzipping Installation Package 1. Download “Hytera PD41X Patrol Management System.rar” from www.hytera.com (Download path: Downloads -> Driver & Software -> PD41X). 2. Unzipping the installation package into a chosen folder.