SmartStruxure™ Lite Solution Course SmartStruxure Lite Introduction HOW ALL FITS TOGETHER PPT ver. 1.1.0.0 IP/Ethernet network design StruxureWare Building Expert (in web browser) Allows to configure and monitor your deployment. http Monitor Stand-alone deployment, everything goes through the monitor (A monitor is needed if more then 1 MPM in the network and if a network functionality is required) LAN Ethernet LAN Passive nodes BACnet points collected by the monitor Cost effective solution for small-to-medium buildings Schneider Electric - SmartStruxure™ Lite solution Training 2 IP/Ethernet network design (cont’d) Schneider Electric or third-party BACnet Building Management System (BMS) Integration to BACnet system No need for a monitor if all nodes are connected through IP LAN BACnet IP / BACnet Ethernet Ethernet LAN Passive nodes Schneider Electric - SmartStruxure™ Lite solution Training BACnet points collected by the BMS directly 3 General network design ● Guidelines – network traffic only ● CANBus, Ethernet, ZigBee: ● Ratio of 24 passive nodes to 1 monitor node BMS Monitor Monitor Monitor LAN Ethernet LAN or CANbus or ZigBee Up to 24 nodes per group Group A Schneider Electric - SmartStruxure™ Lite solution Training Group B Group C 4 Network discovery StruxureWare Building Expert (in web browser) Monitor LAN Monitor send a heartbeat request Ethernet Schneider Electric - SmartStruxure™ Lite solution Training By the network discover y command and every 10 minutes 5 Network discovery (continued) StruxureWare Building Expert (in web browser) The Monitor plays a significant role both for monitoring and for networking Monitor LAN Remote database download Ethernet End-devices Passive nodes Schneider Electric - SmartStruxure™ Lite solution Training 6 Normal operation – COV based StruxureWare Building Expert (in web browser) Monitor LAN Property Casts sent on change of value (COV) 30 seconds by default. Ethernet 23.0 °C 22.8 °C Passive nodes Schneider Electric - SmartStruxure™ Lite solution Training 7 CANbus network design ● 120 Ohms resistors must be placed at both termination points of the CANbus chain link. ● CANbus transfer rate is proportional to total chain-link length. BMS ● 125 Kbps: Up to 500 m ● 250 kbps: Up to 250 m (default setting) ● 500 kbps: Up to 100 m ● Must be the same speed configuration for all MPMs LAN Monitor Schneider Electric - SmartStruxure™ Lite solution Training passive nodes 8 ZigBee concepts ● ZigBee coordinator is a device that sets up the network, is aware of all the nodes within its network. Every ZigBee network must contain a network coordinator. ● ZigBee router can act as an intermediate router, passing on data from other devices. End-devices BMS LAN Monitor Router nodes Schneider Electric - SmartStruxure™ Lite solution Training Coordinator 9 ZigBee network design – best practices Building Expert BMS ● Route redundancy ● Ideally no more than 5 wireless hops ● Example respecting guidelines LAN Router / Passive nodes Site Monitor Coordinator Schneider Electric - SmartStruxure™ Lite solution Training 10 BAD wireless network design Building Expert BMS ● No Route redundancy ● Example not respecting guidelines LAN Coordinator Monitor Schneider Electric - SmartStruxure™ Lite solution Training Passive nodes Passive nodes & Routers & Routers 11 Using multiple network technology ● Possible if the Monitor is the originating point of each technology segment. Web browser BMS Passive nodes Caution! This is a theoretical and principal schematic. LAN Ethernet Passive nodes CANBus ZigBee Passive nodes Monitor Coordinator Schneider Electric - SmartStruxure™ Lite solution Training 12 Other Get started Application package Schneider Electric - SmartStruxure™ Lite solution Training 14 Schneider Electric - SmartStruxure™ Lite solution Training 15 Uses cases Schools Hotels School Needs SmartStruxure™ Lite answers Water based heating systems Proven solution ● Perimeter heating with radiators ● Perimeter heating with fan coils ● Smart wireless actuator ● Wireless room and terminal controllers School schedules Wireless retrofit during school days ● Can’t disturb classes ● Can’t afford overtime pay ● Limit wiring to a minimum ● Limit invasiveness and disturbance Out-buildings Bring them in wirelessly with ZigBee Hazards in the walls Avoid renovation, repair & repaint work ● Dust or asbestos fears ● Keep parents and administrators happy Tight budget StruxureWare™ Building Expert ● Fixed costs of front-end, servers and gateways limiting the ROI? ● No license fee! Low fixed costs! ● Scalable to StruxureWare™ Building Operation, BACnet, EcoStruxure Web Services, oBIX Schneider Electric - SmartStruxure™ Lite solution Training 17 Perimeter heating school retrofit job Problem Boiler ● Single loop perimeter heating ● Comfort & energy cost issues Objectives ● Add zone & remote control ● With a short payback Solution ● Managers ● ● ● ● Network throughout the building Control actuators Receive data from sensors Host Building Expert over the LAN LAN ● Smart wireless actuators ● EnOcean T° sensors ● Management via Building Expert Schneider Electric - SmartStruxure™ Lite solution Training 18 Unit ventilator/fan coil school retrofit job Building Expert Network to other zones LAN Wireless manager (one unit can manage many zones) Light relay with dimming Swap old stat with SE7000 Light sensor and light switch Unit ventilator or fan coil If there are no old stats or existing wiring isn’t usable, inside Schneiderplace Electric -SEC-TE SmartStruxure™ Lite unit solution Training 19 Out-buildings & school trailers Schools run out of space and use out-buildings to fill gap ● Integrating these buildings into an automation system is difficult & costly ● SmartStruxure™ Lite can integrate them easily and at a low cost ● Manage multiple buildings from StruxureWare Building Expert or use larger systems internet StruxureWare™ Building Expert EcoStruxure WebService internet Up to 300 m line of sight Schneider Electric - SmartStruxure™ Lite solution Training 20 Use case: simple & complete automation Objectives: happy guests & bottom line ● Control heating and cooling costs Room 205 SE7000 ● Get your guests in the comfort zone Room 204 ● Remote management for more efficiency FC, HP Solution ● SE7000 to control HVAC in each room Room 207 Room 206 Room 209 Room 208 ● Embedded PIR motion sensor (optional) sets temperature for occupied/unoccupied mode ● Guests can adjust setpoints for comfort ● Networking and integration performed by MPM devices each handling several zones ● Management can set high and low limits according to schedules MPM-GW Room 211 Room 210 ● Management can put rooms into vacant mode for maximum energy savings Schneider Electric - SmartStruxure™ Lite solution Training 21 Use case: simple & complete automation Solution (cont’d) ● Management via StruxureWare™ Building Expert ● Can import hotel floorplans and define custom zones with color codes for user-friendly visualizations Scale over time with wireless ● Easily add points with EnOcean and ZigBee Room 205 ● Lighting control ● Additional sensors ● Other applications ● Can integrate wireless keycard reader to set occupied/unoccupied mode Schneider Electric - SmartStruxure™ Lite solution Training Light relay Keycard reader 22 Use case: comfort, efficency & branding Create loyalty with your brand Customizable cover, color, language and screensaver my Hotel Or integration via MPM devices Direct integration to BACnet LAN Swap old stat with SE8000 StruxureWare Building Expert for small hotels and motels. Integrate to other systems for larger buildings. PIR motion sensor included Fan coil, heat pump or other system Use relay pack for high voltage fan coils Schneider Electric - SmartStruxure™ Lite solution Training 23 Example scenario 1 ● Small retail outlet ● 4 zones - HVAC ● Monitoring only Example scenario 1 ● A few SE7000 ● One MPM connected to the LAN ● Management with StruxureWare Building Expert LAN Example scenario 2 ● Small retail outlet ● 5 zones - Lighting ● Monitoring and Override Example scenario 2 ● Two MPM-GW communicating via ZigBee ● Control of multiple EnOcean switches and relays ● Management with Building Expert ZigBee Coordinator Site Monitor Connected to LAN LAN ZigBee Router Passive Example scenario 3 ● ● ● ● Small retail outlet 5 zones - Lighting Monitoring and Override Energy Metering Example scenario 3 ● Add MPM-UN with Modbus to connect power meter ZigBee Router Passive ZigBee Router Passive Modbus power meter ZigBee Coordinator Site Monitor Connected to LAN LAN Room 101 Application: Hotel room, Dorm room, Old age unit or Hospital room Door Sensor Thermostat Fancoil Unit Window Sensor Floor / Hotel Controller Automation Server SmartStruxure Entreprise Server Web-pages for simple monitoring & control SmartStruxure Building Operation SmartStruxure Lite Monitoring & Control Solution Schneider Electric - SmartStruxure™ Lite solution Training or SmartStruxure Solution Full Building Management System 30 VAV applications Aggregation & management Use VAV managers ● Each unit has: Building Expert ● Pressure sensor ● Actuator (optional) ● Wireless networking ● Makes installation faster and easier Terminal controllers (if direct control of RTUs is needed) MPM device ● Building Expert ● Has a PID loop object to help manage VAVs. ● Programming is stored locally on each VAV manager for redundancy. HVAC RTU or other HVAC equipment Zoning VAV managers (MPM-VA) VAV boxes Schneider Electric - SmartStruxure™ Lite solution Training If required Additional wired and wireless sensors for T°, H%, motion, CO2, etc. Each VAV manager has: • Embedded pressure sensor • 6 inputs and 6 outputs • EnOcean wireless I/O • Support for ZigBee peripherals 31 Metering and Sub-metering Metering For electrical, gas & water metering ● Multi-purpose managers can integrate Modbus, EnOcean and ZigBee metering and pulse-counting devices ● Building Expert has objects to facilitate the integration of select Schneider Electric and Veris products. Currently, these products are: ● ION6200 ● PM750 ● Veris E5 series ● Veris H803 series ● iEM3250/5 ● PM3250/5 ● Data can be: ● Viewed in Building Expert ● Integrated into larger iBMS ● Exported over FTP Schneider Electric - SmartStruxure™ Lite solution Training Building Expert Pulse counting and smart plugs You can network to reach metering points separated by long distances MPM-UN can integrate various devices using Modbus, EnOcean and ZigBee protocols MPM-UN Other Modbus meters. Schneider Electric and Veris meters with objects in Building Expert to facilitate their integration. Terminal controllers can be used for fast pulse counting 32 Basic and advanced lighting Office single load, common areas and outdoor lighting Basic lighting Daylight harvesting Building Expert Wired and/or wireless lighting control ● For wired and wireless control, use the MPM-UN ● For wireless control only, use the MPM-GW Building Expert and EnOcean MPM-GW MPM-UN Connection to Modbus lighting panel or wired contacts ● Objects to facilitate the integration of light switches and relays already exist. ● New objects are coming up for the following sensors: motion, light (lux), door contact and window contact Light sensor Relay Occupancy sensor Switch Schneider Electric - SmartStruxure™ Lite solution Training Dimming relay Relays for motorized blinds & smart windows 33 StruxureWare™ Building Expert ● StruxureWare Building Expert is a complete building automation IP interface available from any internet connection. ● The Web server is active on every Manager (MPM). ● No license, no software to install ● Used to monitor and commission your network ● Supported browser: Firefox ESR ● From version 2.7 are the most common browsers supported ● Local port : 80 Schneider Electric - SmartStruxure™ Lite solution Training 34 Resources for you ● Product Support Services (PPS) – After an approved certification test ● The Schneider Electric Exchange Download Center ● (https://buildingsdownloads.schneider-electric.com) ● Documentation.SmartStruxureLite.com ● Still valid but the above download center is the recommended solution Schneider Electric - SmartStruxure™ Lite solution Training 35 End