Trusted and preferred by professionals since 1946 we are known for our commitment to quality, performance and consistency. Industries Served • • • • Manufacturing / Fabrication Hospitals & Health Care Facilities Fireproofing Residential/Commercial Retail / Commercial Facilities • Food & Beverage Processing • Maintenance Oil & Gas • Water & Wastewater Facilities Services Offered • Project Inspection • Coating Recommendation • Failure Analysis • Free Technical Service • Job Site Training • Specification Writing Danny Janulek – Idaho, Nevada & Northern California (650) 622-6509 djanulek@kellymoore.com Steve Sexton – Northern & Central California (925) 984-5036 ssexton@kellymoore.com Greg Sutton – Texas, Oklahoma & Arkansas (918) 625-2538 gsutton@kellymoore.com Contego Passive Fire Barrier (PFB) 1. (SFRM) Spray Applied Fire Resistive Material 2. (PFB) Passive Fire Barriers 3. (PFP) Passive Fire Protection (UL1709) Monokote® is a gypsum based cementitious spray-applied fire resistive material for structural steel framed buildings The term cementitious as defined by ASTM or Underwriters Laboratories Inc. applies to all fireproofing that is wet mixed and then pumped as a slurry. Cementitious does not refer to portland cement content. There are two basic categories of Architectural Fireproofing, Residential and Commercial applications. These products usually consist of a thin-film latex or solvent based material. There are two basic types of industrial fireproofing— cementitious and epoxy intumescent. These products are usually designed to meet UL1709 Cementitious fireproofing is a cement-based material that provides fire protection through its inherent insulative properties. Epoxy intumescent fireproofing has the appearance and application characteristics of a protective coating. Materials including structural steel, aluminum, dimensional lumber, manufactured wood products, trusses, drywall, spray polyurethane foam insulation, HDPE wall panels, concrete, plaster, solid core doors and more. The product may also be used for conduit, decking and cladding. Intumescent Fireproofing Systems allow designers to express the steel structure as an art form in buildings where fire resistance ratings are required. Project planners now have flexibility to create unique exposed steel designs where fire resistance ratings are required, with aesthetically pleasing, durable and cost effective alternatives. Decorative Thin Film Coating 1, 2 and 3 Hour Fire Ratings 0 V.O.C. /Non-Toxic Excellent Durability High Impact Strength Provides A Clean Dust Free Environment Easy Paint-Like Application Suitable For Top coating with any KM Paint Marketable to our Painting Contractors Direct Manufacturer Support Tested to 9 ASTM International Standards: ASTM D 1475 - Standard Test Method For Density of Paint, Varnish, Lacquer, and Related Products. ASTM D 2369 - Standard Test Method For Volatile Content of Coatings. ASTM D 3359 - Standard Methods for Measuring Adhesion by Tape Test (Methods A and B) ASTM D 3960 - Standard Practice for Determining Volatile Organic Compound (VOC) Content of Paints and Related Coatings. ASTM D 4017 - "Standard Test Method for Water in Paints and Paint Materials by Karl Fischer Method. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials. ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials. ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. ASTM E 662 - Standard Guide for Measurement of Gases Present or Generated During Fires. TOTAL Firefilm 722 gallons ONE HOUR PROTECTION Total Total Linear Ft. Square Ft. W Shapes - Wide Flange Beams and Columns Section* W/D** ft.2/ft W12x22 W12x16 0.560 0.410 3.28 3.25 384.00 1178.00 L Shapes - Angles Section* L6x6x1/2 L5x3x1/4 L4x4x3/8 L4x4x1/4 L3x3x3/8 L3x3x1/4 W/D** 0.824 0.418 0.615 0.416 0.608 0.414 Total Linear Ft. ft.2/ft 1.98 1.32 1.32 1.32 0.98 0.98 510.00 92.00 61.00 66.00 142.00 526.00 1259.52 3828.50 Total Square Ft. 1009.80 121.44 80.52 87.12 139.59 517.06 DFT Mils 64 88 DFT Mils 22 43 29 43 30 44 1 HOUR RATINGS Coverage (Sq. Ft./Gal.) Required Gallons 15.00 83.97 10.91 350.95 Sub Tot 434.91 Coverage Required (Sq. Ft./Gal.) Gallons 43.64 22.33 33.10 22.33 32.00 21.82 23.14 5.44 2.43 3.90 4.36 23.70 497.89 Minimum Coats 3 4 Minimum Coats 1 2 2 2 2 2 Sample thickness required for 2 Hour application. Beam Type Albi-Clad Contego W10x49 HSS 8x8x.500 310 mils 334 mils 77 mils 42 mils Winner!! Sample thickness required for 2 Hour application: Beam Type FIREFILM CONTEGO W10x49 Not possible (Design X641) HSS 8x8x.500 186 mils (Design X642) 77 mils 42 mils Winner! A/D Firefilm® III Great Western Painting Commercial & Industrial Painting. Serving the U. S. A. Water Towers -Tanks - Hotels Chemical plants - High Rises - Structural Steel 1 - 877-749-5554 pat@greatwesternpainting.com Thank You