Corporate Design PowerPoint-Basis

advertisement
Synco living
Train the Trainer
Introduction Lights & Blinds
Hager Products
August 2007
Page 1/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Overview
The products of Hager tebis TX offer the following features:
RF 868 MHz
No permanent transmitters since duty cycle must be < 1%
KNX standard
All Hager tebis TX products communicate on the open
KNX bus standard (KNX RF)
Bidirectional system
The devices can receive and send telegrams, thus facilitating remote control
Range
100 m in open space, approx. 30 m inside buildings (depending on the building‘s structure)
Page 2/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Overview
Other features offered by the Hager product line:
Battery life
All battery-powered devices are designed for a life expectancy of
5 years
For new construction and renovation projects
To commission Hager components, a tool is required
=> TX100
Page 3/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Overview
The product range of Hager tebis TX includes the following components for the control of lights and blinds:
Switch actuators
Plug adapters
Dim actuators
Blind / blind actuators
Combi devices
Inputs
Handheld transmitters
Hager has an extensive range of products.
This presentation focuses on the major components.
Page 4/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Overview
To switch a lamp, for example, Hager tebis TX requires a transmitter (operation) and an actuator in most cases.
Actuator
Transmitter
Page 5/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
TR 201 flush-mounted output 16 A mains-powered
Power supply
Rated voltage: AC 230 V, 50 Hz
Load output
Number: 1 contact 16 A
Types of load
Incandescent lamps 2,300 W
AC 230 V halogen lamps 2,300 W
ELV halogen lamps (12 or 24 V) via
ferromagnetic transformer 1,600 W
ELV halogen lamps (12 or 24 V) via
electronic transformer 1,200 W
Fluorescent lamps 28 x 36 W (max. 120 μF)
Page 6/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
1 LED
2 Antenna
3 Connection terminals
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
No wiring connection between transmitter and actuator
Page 7/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
TR 270 plug adaptor
Power supply
Rated voltage: AC 230 V, 50 Hz
Load output
Number: 1 contact (16 A)
Types of load
Incandescent lamps 2,300 W
AC 230 V halogen lamps 2,300 W
ELV halogen lamps (12 or 24 V) via
ferromagnetic transformer 1‘600 W
ELV halogen lamps (12 or 24 V) via
electronic transformator 1‘200 W
Fluorescent lamps 28 x 36 W (max. 120 μF)
Page 8/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
1 LED
2 Pushbutton
-
August 2007
Available in:
Schuko, FR, IT, CH
Introduction Lights & Blinds, Hager tebis TX
Actuators
No wiring connection between transmitter and actuator
Page 9/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
TR 210 single-channel flush-mounted dimmer 200 W
Power supply
Rated voltage: AC 230 V, 50 Hz
Load output
Number: 1 dim channel
Types of load
Incandescent lamps 20…200 W
AC 230 V halogen lamps 20…200 W
ELV halogen lamps (12 or 24 V) via
ferromagnetic transformer 20…200 VA
ELV halogen lamps (12 or 24 V) via
electronic transformer 20…200 VA
Page 10/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
1 LED
2 Antenna
3 Connection terminals
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
No wiring connection between transmitter and actuator
Page 11/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
TR 271 dimmer plug adaptor
Power supply
Rated voltage: AC 230 V, 50 Hz
Load output
Number: 1 contact 300 W
Types of load
Incandescent lamps 20…300 W
AC 230 V halogen lamps 20…300 W
ELV halogen lamps (12 or 24 V) via
ferromagnetic transformer 20…200 VA
ELV halogen lamps (12 or 24 V) via
electronic transformer 20…200 VA
Page 12/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
1 LED
2 Pushbutton
-
August 2007
Available in:
Schuko, FR, IT, CH
Introduction Lights & Blinds, Hager tebis TX
Actuators
No wiring connection between transmitter and actuator
Page 13/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
TR 221 flush-mounted output for blinds or shutters, mains-powered
Power supply
Rated voltage: AC 230 V, 50 Hz
Load output
Number: 1 contact 6 A
Technical features
Power dissipation: 2 W
Delay time between
2 opposite directions: 600 ms
Page 14/23
Overview
1 LED
2 Antenna
3 Connection terminals
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Actuators
M
No wiring connection between transmitter and actuator
Page 15/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Combi Devices
TR 501 1 input, 1 flush-mounted output 10 A, mains-powered
Power supply
Rated voltage: AC 230 V, 50 Hz
Load input and output
Output: 1 contact 10 A
Input: 1 potential-free contact
Types of load
Incandescent lamps 1,500 W
AC 230 V halogen lamps 1,500 W
ELV halogen lamps (12 or 24 V) via
ferromagnetic transformer 800 W
ELV halogen lamps (12 or 24 V) via
electronic transformer 600 W
Fluorescent lamps 11 x 36 W (max. 47 μF)
Page 16/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
1 LED
2 Antenna
3 Connection terminals
4 Push button
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Combi Devices
Combination of transmitter and actuator in one device
Page 17/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Combi Devices
TR 521 2 inputs / 1 flush-mounted output for blinds or shutters mains-powered
Power supply
AC 230 V
Rated voltage: AC 230 V, 50 Hz
Load input and output
Output: 1 contact 6 A
Input: 2 potential-free contacts
Technical features
Power dissipation: 2 W
Delay time between
2 opposite directions: 600 ms
Page 18/23
Overview
1 LED
2 Antenna
3 Connection terminals
4 Push button
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Introduction Lights & Blinds, Hager tebis TX
Inputs
TR 302A / TR 304A flush-mounted inputs
Power supply
1 piece ½ AA 3 V lithium battery
Life: Approx. 5 years
Functions
Switch
Dim
Blinds
Scene
TR 302A => 2 inputs
TR 304A => 4 inputs
Page 19/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
1 Lid
2 Battery
3 LED
4 Antenna
5 Pushbutton
6 Connector
Introduction Lights & Blinds, Hager tebis TX
Inputs
TR 302B / TR 304B flush-mounted inputs
Power supply
Rated voltage: AC 230 V, 50 Hz
Functions
Switch
Dim
Blinds
Scene
TR 302B => 2 inputs
TR 304B => 4 inputs
Page 20/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
1 Connection terminals
2 Antenna
3 LED
4 Connector
Introduction Lights & Blinds, Hager tebis TX
Inputs
KALLYSTO pushbuttons
Pushbuttons and frames for use with TR302A/B and TR304A/B inserts.
The following versions are available:
4 colors
Ultrawhite
Light-grey
Anthracite
Recessed / wall mounting
Single / double pushbutton
Single pushbutton => 2 inputs
Double pushbuttons => 4 inputs
Page 21/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
Black
Introduction Lights & Blinds, Hager tebis TX
Inputs
TD110 / 210 / 310 2-, 4- and 6-way pushbuttons
Power supply
2 pieces CR2430 3 V batteries
Life: Approx. 5 years
Functions
Switch
Dim
Blinds
Scene
TD 110 => 2 inputs
TD 210 => 4 inputs
TD 310 => 6 inputs
Page 22/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007
1 LED
2 Pushbutton
3 Baseplate
4 Label holder slots
Introduction Lights & Blinds, Hager tebis TX
Inputs
TU204A / 208A / 224A radio remote controls
Power supply
1 piece CR 1/3 N 3 V battery
Life: approx. 3 years
Functions
Switch
Dim
Blinds
Scene
1 LED
2 Buttons
3 Button
4 LED
TU 204A => 4 channels
TU 208A => 8 channels
TU 224A => 24 channels
Page 23/23
Overview
Train the Trainer
Actuators
Combi Device
Inputs
-
August 2007