Synco living Train the Trainer Introduction Lights & Blinds Hager Products August 2007 Page 1/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Overview The products of Hager tebis TX offer the following features: RF 868 MHz No permanent transmitters since duty cycle must be < 1% KNX standard All Hager tebis TX products communicate on the open KNX bus standard (KNX RF) Bidirectional system The devices can receive and send telegrams, thus facilitating remote control Range 100 m in open space, approx. 30 m inside buildings (depending on the building‘s structure) Page 2/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Overview Other features offered by the Hager product line: Battery life All battery-powered devices are designed for a life expectancy of 5 years For new construction and renovation projects To commission Hager components, a tool is required => TX100 Page 3/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Overview The product range of Hager tebis TX includes the following components for the control of lights and blinds: Switch actuators Plug adapters Dim actuators Blind / blind actuators Combi devices Inputs Handheld transmitters Hager has an extensive range of products. This presentation focuses on the major components. Page 4/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Overview To switch a lamp, for example, Hager tebis TX requires a transmitter (operation) and an actuator in most cases. Actuator Transmitter Page 5/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators TR 201 flush-mounted output 16 A mains-powered Power supply Rated voltage: AC 230 V, 50 Hz Load output Number: 1 contact 16 A Types of load Incandescent lamps 2,300 W AC 230 V halogen lamps 2,300 W ELV halogen lamps (12 or 24 V) via ferromagnetic transformer 1,600 W ELV halogen lamps (12 or 24 V) via electronic transformer 1,200 W Fluorescent lamps 28 x 36 W (max. 120 μF) Page 6/23 Overview Train the Trainer Actuators Combi Device Inputs 1 LED 2 Antenna 3 Connection terminals - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators No wiring connection between transmitter and actuator Page 7/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators TR 270 plug adaptor Power supply Rated voltage: AC 230 V, 50 Hz Load output Number: 1 contact (16 A) Types of load Incandescent lamps 2,300 W AC 230 V halogen lamps 2,300 W ELV halogen lamps (12 or 24 V) via ferromagnetic transformer 1‘600 W ELV halogen lamps (12 or 24 V) via electronic transformator 1‘200 W Fluorescent lamps 28 x 36 W (max. 120 μF) Page 8/23 Overview Train the Trainer Actuators Combi Device Inputs 1 LED 2 Pushbutton - August 2007 Available in: Schuko, FR, IT, CH Introduction Lights & Blinds, Hager tebis TX Actuators No wiring connection between transmitter and actuator Page 9/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators TR 210 single-channel flush-mounted dimmer 200 W Power supply Rated voltage: AC 230 V, 50 Hz Load output Number: 1 dim channel Types of load Incandescent lamps 20…200 W AC 230 V halogen lamps 20…200 W ELV halogen lamps (12 or 24 V) via ferromagnetic transformer 20…200 VA ELV halogen lamps (12 or 24 V) via electronic transformer 20…200 VA Page 10/23 Overview Train the Trainer Actuators Combi Device Inputs 1 LED 2 Antenna 3 Connection terminals - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators No wiring connection between transmitter and actuator Page 11/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators TR 271 dimmer plug adaptor Power supply Rated voltage: AC 230 V, 50 Hz Load output Number: 1 contact 300 W Types of load Incandescent lamps 20…300 W AC 230 V halogen lamps 20…300 W ELV halogen lamps (12 or 24 V) via ferromagnetic transformer 20…200 VA ELV halogen lamps (12 or 24 V) via electronic transformer 20…200 VA Page 12/23 Overview Train the Trainer Actuators Combi Device Inputs 1 LED 2 Pushbutton - August 2007 Available in: Schuko, FR, IT, CH Introduction Lights & Blinds, Hager tebis TX Actuators No wiring connection between transmitter and actuator Page 13/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators TR 221 flush-mounted output for blinds or shutters, mains-powered Power supply Rated voltage: AC 230 V, 50 Hz Load output Number: 1 contact 6 A Technical features Power dissipation: 2 W Delay time between 2 opposite directions: 600 ms Page 14/23 Overview 1 LED 2 Antenna 3 Connection terminals Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Actuators M No wiring connection between transmitter and actuator Page 15/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Combi Devices TR 501 1 input, 1 flush-mounted output 10 A, mains-powered Power supply Rated voltage: AC 230 V, 50 Hz Load input and output Output: 1 contact 10 A Input: 1 potential-free contact Types of load Incandescent lamps 1,500 W AC 230 V halogen lamps 1,500 W ELV halogen lamps (12 or 24 V) via ferromagnetic transformer 800 W ELV halogen lamps (12 or 24 V) via electronic transformer 600 W Fluorescent lamps 11 x 36 W (max. 47 μF) Page 16/23 Overview Train the Trainer Actuators Combi Device Inputs 1 LED 2 Antenna 3 Connection terminals 4 Push button - August 2007 Introduction Lights & Blinds, Hager tebis TX Combi Devices Combination of transmitter and actuator in one device Page 17/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Combi Devices TR 521 2 inputs / 1 flush-mounted output for blinds or shutters mains-powered Power supply AC 230 V Rated voltage: AC 230 V, 50 Hz Load input and output Output: 1 contact 6 A Input: 2 potential-free contacts Technical features Power dissipation: 2 W Delay time between 2 opposite directions: 600 ms Page 18/23 Overview 1 LED 2 Antenna 3 Connection terminals 4 Push button Train the Trainer Actuators Combi Device Inputs - August 2007 Introduction Lights & Blinds, Hager tebis TX Inputs TR 302A / TR 304A flush-mounted inputs Power supply 1 piece ½ AA 3 V lithium battery Life: Approx. 5 years Functions Switch Dim Blinds Scene TR 302A => 2 inputs TR 304A => 4 inputs Page 19/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 1 Lid 2 Battery 3 LED 4 Antenna 5 Pushbutton 6 Connector Introduction Lights & Blinds, Hager tebis TX Inputs TR 302B / TR 304B flush-mounted inputs Power supply Rated voltage: AC 230 V, 50 Hz Functions Switch Dim Blinds Scene TR 302B => 2 inputs TR 304B => 4 inputs Page 20/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 1 Connection terminals 2 Antenna 3 LED 4 Connector Introduction Lights & Blinds, Hager tebis TX Inputs KALLYSTO pushbuttons Pushbuttons and frames for use with TR302A/B and TR304A/B inserts. The following versions are available: 4 colors Ultrawhite Light-grey Anthracite Recessed / wall mounting Single / double pushbutton Single pushbutton => 2 inputs Double pushbuttons => 4 inputs Page 21/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 Black Introduction Lights & Blinds, Hager tebis TX Inputs TD110 / 210 / 310 2-, 4- and 6-way pushbuttons Power supply 2 pieces CR2430 3 V batteries Life: Approx. 5 years Functions Switch Dim Blinds Scene TD 110 => 2 inputs TD 210 => 4 inputs TD 310 => 6 inputs Page 22/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007 1 LED 2 Pushbutton 3 Baseplate 4 Label holder slots Introduction Lights & Blinds, Hager tebis TX Inputs TU204A / 208A / 224A radio remote controls Power supply 1 piece CR 1/3 N 3 V battery Life: approx. 3 years Functions Switch Dim Blinds Scene 1 LED 2 Buttons 3 Button 4 LED TU 204A => 4 channels TU 208A => 8 channels TU 224A => 24 channels Page 23/23 Overview Train the Trainer Actuators Combi Device Inputs - August 2007