NT: plete RTAfor the coomns, and O P m o M I tron.c instructi ng the .ex on ecti . www stallati e conn Go to uide, in s before er sourc g n ow p e user cificatio th to e t p s uc prod MTP DA4 and DA8 • Setup Guide This guide provides basic instructions for an experienced installer to set up and operate an Extron MTP DA4 or DA8 distribution amplifier. Pre-installation — Jumpers See the figure at the right or see “Termination and Mute Jumpering” in the MTP DA4 and MTP DA8 User Guide for more information. NOTE: The jumpers have no effect when the DA is part of an MTP CV/SV series, or VTT001/VTR001 system. Serial or Audio (Default) J3 Disable or Mute (Default) Enable Mute J9 Jumper J3 This sets the DA to properly terminate RGB video as well as the audio (default) or serial portion of the input signal. Jumper J9 This sets the DA to always pass the audio or serial link regardless of the contact closure mute status (default). It can also be set to mute the audio or serial link when its video mute function is activated. Installation Step 1 — Mounting Turn off or disconnect all equipment power sources and mount the MTP DA as required. A mounting example is shown below). See “Mounting” in the user guide for more mounting options. 6" Deep Rack Shelf 1/2 Rack Width False Front Face Plate (2) 4-40 x 3/16" screws MT P DA SE RIES Use 2 mounting holes on opposite corners. Figure 1. Mounting the MTP DA Step 2 — Input from the Transmitter Terminate a TP cable as shown in figure 3. Connect the cable into a MTP transmitter and into the AV input connector. Pins: 12345678 Step 3 — Outputs to the Receivers Pin Terminate up to four or eight (depending on model) TP cables as shown in the figure to the right. Connect the cables into the DA AV output ports and into receivers that are compatible with the transmitter. NOTES: • The inputs and outputs should be terminated using the same standard on both ends of the cable. • Only use the TIA/EIA T568A standard when using Enhanced Skew-Free™ AV cable. A/V INPUT Insert Twisted Pair Wires RJ-45 Connector 1 2 3 4 5 6 7 8 1 A/V OUTPUTS 2 3 4 T568A Wire color T568B Wire color White-green Green White-orange Blue White-blue Orange White-brown Brown White-orange Orange White-green Blue White-blue Green White-brown Brown MTP DA4 and DA8 • Setup Guide Step 4 — Power POWER 12V xA MAX Wire the 2-pole captive screw connector for the external 12 VDC power supply (see the image on the right). Smooth Ridges A Grounding the Power Input Port Rear Panel A Extron MTP DA products can be adversely affected by electrostatic discharge (ESD) if they are not grounded correctly. 3/16" (5 mm) Max. To prevent malfunctions or product damage, an experienced installer can correctly ground an Extron MTP DA product by inserting one end of the grounding wire to the negative or ground pin on the power input connector (see the image on the right). Tie the other end of the wire to an earth ground. Tie Wrap SECTION A–A Ridges Power Supply Output Cord Plug the connector into the MTP DA. Earth Ground If you have any questions about how to ground a product in a specific application, contact an Extron technical support specialist. Operation — Mutes To mute an output, tie the Output Mute pin to the ground ( ). To mute all outputs, tie the A pin to the ground (see figure 2 for more information). DVD Extron MTP R AV Extron MTP DA8 Twisted Pair Transmitter Twisted Pair Receivers Twisted Pair Distribution Amplifier PUT OUTR L SHARP Extron MTP T AV RCA INP UT A O VIDE R SV L T INPU R 12V 0.5a MAX MTP 12V MAX 0.5a VIDE O MTP OUT T SV PUT A RCA Pin Contact Closure Function 1 Out #1 Mute output #1 2 Out #2 Mute output #2 3 Out #3 Mute output #3 4 Out #4 Mute output #4 5 Out #5 Mute output #5 6 Out #6 Mute output #6 7 Out #7 Mute output #7 8 Out #8 Mute output #8 A Out All Mute all output Gnd Ground TE T MU TPU OU 8 7 1 2 3 4 5 6 7 8 A 6 TS TPU 5 OU 4 3 2 1 INP UT PUT OUTR SHARP L ER - POW 5 6 7 8 A MTP DA4 Output Mute Connector 1 2 3 4 A Extron USA - West Extron USA - East +1.714.491.1500+1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX MTP TP Cable PUT OUTR SHARP L Figure 2. Mute Connector and Pinout Extron Headquarters +800.633.9876 Inside USA/Canada Only A O VIDE R SV T INPU 12V MAX 0.5a A O VIDE R SV T INPU MTP 12V MAX 0.5a Up To 8 Receivers PUT OUTR L SHARP 1 2 3 4 + MTP DA8 Output Mute Connector 12V MAX 0.5A A O VIDE R SV T INPU MTP 12V MAX 0.5a TP Cable Flat Panel Display Figure 3. Example of a Typical MTP DA8 Application Extron Europe +800.3987.6673 Inside Europe Only Extron Asia +800.7339.8766 Inside Asia Only +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.4664 FAX Extron Japan +81.3.3511.7655 +81.3.3511.7656 FAX Extron China +4000.EXTRON +4000.398766 Inside China Only Extron Middle East Extron Korea +971.4.299.1800 +971.4.299.1880 FAX +82.2.3444.1571 +82.2.3444.1575 FAX +86.21.3760.1568 +86.21.3760.1566 FAX © 2013 Extron Electronics All rights reserved. www.extron.com Extron India 1800.3070.3777 Inside India Only +91-80-3055.3777 +91 80 3055 3737 FAX 68-975-50 Rev. D 01 13