User Guide

advertisement
IriShield™-USB MK 2120U
Quick Start Guide
Introduction
IriShield™-USB MK 2120U is an ultra-compact, auto-capture camera module, complete with onboard
iris recognition and a PKI-based security infrastructure that ensures complete data security.With its low cost,
IriShield™ Series will lower the entry barrier to deploying iris biometric solutions in all sorts of applications.
What’s in the box:
1.
2.
3.
IriShield™-USB MK 2120U
Micro USB Cable
Pouch
Specification
Capture Mode
Capture Distance
Image Format
Sensor Resolution
Dimension
Power
Illumination
Environmental
Resolution
Connectivity
Security
Compliance & Certificates
Host OS
Auto Capture
4.7 cm - 5.3 cm (1.8 inches -2.1 inches) from the image sensor (Optimal distance
= 5 cm (2 inches), Focal depth = 6 mm (0.2 inch)
ISO Standard 19794-6 (2005 & 2011), (640 x 480 Pixels, 8 bit Grayscale), full
support of K1, K2, K3, K7
VGA
51.2mm x 92.6mm x 15.1mm (2 inches x 3.6 inches x 0.59 inch)
Single USB Bus Powered (DC +5V±5%) (Max power consumption=250mA)
Infrared LED
0 °C to + 45 °C (Operating); 10% to 90% Humidity (Non-Condensing). Usage:
Indoor; Outdoor (avoid direct sunlight and bright reflections)
Spatial : = 60% @ 4.0 Lp/mm, Pixel : = 16 Pixels/mm
USB 2.0
PKI (2048-bit) and AES (256-bit); X509 Certificate, PFX/PKCS#12 Certificate , RSA
key pair generated on-board
Eye safety standard (IEC 62471:2006-07), RoHS, FCC-Class A* , IP54*
Windows Family, Linux Family, WinCE, Embedded Linux, and Android
System Requirement
1.
IriShield™-USB MK 2120U is an onboard-processing with no special requirement for host device
except USB 2.0 port.
How to Connect
1.
2.
Connect one end of USB cable into IriShield™-USB MK 2120U device.
Connect the other end of USB cable into the PC’s or Host’s USB Port.
How to Install
1.
2.
3.
Device driver download details will be sent via email.
Choose “Update Driver” on IriShield in Device Manager.
Select the folder contains the driver and follows the instructions from the installer to driver
installation.
Warnings and Precautions (Hardware)
1.
2.
3.
4.
5.
6.
7.
8.
9.
Clean regularly to remove dust, but do not use any cleaning solutions. Only wipe the device with a
smooth cloth. Keep the lens free of dust and dirt, and use a special optical cloth in order to not
scratch optics.
Do not allow water to leak into the device or operate the device in humid conditions where water
might condense upon the electronics.
Do not operate device in places where temperature reach extremes beyond the stated range.
Do not place the device next to heating equipment.
Do not place magnets near the device.
Do not apply voltage or current beyond the stated range.
Do not disassemble components from the boards or alter wiring or board design.
Do not drop the device or submit it to sudden impact or mechanical stresses.
Do not remove the warranty seal.
Any damage to the device caused by these activities will void the warranty.
Service Network
Service helpline: support@biometronic.com or contact 080-65657615
Customer Complaint: complaint@biometronic.com or 080-28460229
Customer Feedback Form: info@biometronic.com
Biometronic Technology Private Limited,
Pyramid North Square, 109/1B, 1st Floor, 3rd Division,
Nehru Nagar on International Airport Road, Yelahanka,
Bangalore 560064, India.
www.biometronic.com
IriShield™-USB BK 2121U
Quick Start Guide
Introduction
IriShield™-USB BK 2121U is an ultra-compact, auto-capture camera module, complete with onboard
iris recognition and a PKI-based security infrastructure that ensures complete data security.With its low cost,
IriShield™ Series will lower the entry barrier to deploying iris biometric solutions in all sorts of applications.
What’s in the box:
1.
2.
IriShield™-USB BK 2121U
Micro USB Cable
Specification
Capture Mode
Capture Distance
Image Format
Sensor Resolution
Dimension
Power
Illumination
Environmental
Resolution
Connectivity
Security
Compliance & Certificates
Host OS
Auto Capture
13.5 cm - 14.5 cm (5.3 inches -5.7 inches) from the front of camera Lens(Optimal
distance = 14 cm (5.5 inches), Focal depth = 1.0 cm (0.4 inch),Field of View = 3.3
cm x 2.4 cm at 15 cm (1.3 inches x 0.9 inch at 5.9 inches)
ISO Standard 19794-6 (2005 & 2011), (640 x 480 Pixels, 8 bit Grayscale), full
support of K1, K2, K3, K7
VGA
IriShield-USB: 124 mm x 63.2mm x 42.5 mm (4.9 inches x 2.49 inches x 1.68
inches). Goggle: 200 mm x 145 mm x 72 mm (7.9 inches x 5.7 inches x 2.8 inches)
Single USB Bus Powered (DC +5V±5%) (Max power consumption=430mA)
Infrared LED
-20°C to +60°C (Storage); 0°C to +50°C (Operating). Usage: Indoor; Outdoor
(avoid direct sunlight and bright reflections)
Spatial : = 60% @ 4.0 Lp/mm, Pixel : = 16 Pixels/mm
USB 2.0
PKI (2048-bit) and AES (256-bit); X509 Certificate, PFX/PKCS#12 Certificate , RSA
key pair generated on-board
Eye safety standard (IEC 62471:2006-07), RoHS, FCC-Class A* , IP54*
Windows Family, Linux Family, WinCE, Embedded Linux, and Android
System Requirement
1.
2.
IriShield™-USB BK 2121U is an onboard-processing with no special requirement for host device
except USB 2.0 port.
PC support of USB 2.0 preferred for smooth data streaming.
How to Connect
1.
2.
Connect one end of USB cable into IriShield™-USB BK 2121U device.
Connect the other end of USB cable into the PC’s or Host’s USB Port.
How to Install
1.
2.
3.
Device driver download details will be sent via email.
Choose “Update Driver” on IriShield in Device Manager.
Select the folder contains the driver and follows the instructions from the installer to driver
installation.
Warnings and Precautions (Hardware)
1.
2.
3.
4.
5.
6.
7.
8.
9.
Clean regularly to remove dust, but do not use any cleaning solutions. Only wipe the device with a
smooth cloth. Keep the lens free of dust and dirt, and use a special optical cloth in order to not
scratch optics.
Do not allow water to leak into the device or operate the device in humid conditions where water
might condense upon the electronics.
Do not operate device in places where temperature reach extremes beyond the stated range.
Do not place the device next to heating equipment.
Do not place magnets near the device.
Do not apply voltage or current beyond the stated range.
Do not disassemble components from the boards or alter wiring or board design.
Do not drop the device or submit it to sudden impact or mechanical stresses.
Do not remove the warranty seal.
Any damage to the device caused by these activities will void the warranty.
Service Network
Service helpline: support@biometronic.com or contact 080-65657615
Customer Complaint: complaint@biometronic.com or 080-28460229
Customer Feedback Form: info@biometronic.com
Biometronic Technology Private Limited,
Pyramid North Square, 109/1B, 1st Floor, 3rd Division,
Nehru Nagar on International Airport Road, Yelahanka,
Bangalore 560064, India.
www.biometronic.com
Download