- Jawaharlal Nehru Technological University

advertisement
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA
TENDER NOTICE
JAWAHARLAL NEHRU TECHNOLOGICAL
UNIVERSITY KAKINADA , KAKINADA – 533 003, A.P.
No. JNTUK/IST/Schools/Equipment /2014 Date: 09.08.2014
Sealed tenders are invited from reputed Dealers/Suppliers
for the supply of the Lab equipment for various Schools
under IST, JNTUK, Kakinada. The details can be
downloaded from www.jntuk.edu.in
Sd/- Registrar
1
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA
Tender Notice No. JNTUK/IST/Schools/Equipment/2014
Dt: 09.08.2014
TENDER SCHEDULE
1.
GENERAL CONDITIONS:
Please quote your lowest rates for each item described. The quotation should reach
this office on or before 26.08.2014 by 5:00 p.m. Sealed covers should be submitted
for the items super scribing as “Tender No.”, “Date of opening:”, “Item Number(s)”.
The sealed covers should be sent by the Registered Post or to be dropped in the
sealed box provided in the office of the Registrar. The tender will be opened on
27.08.2014 at 10:30 a.m. by the undersigned/his nominee in the presence of the
committee members and available tenderers’ or their representatives. The tenderers
who submit the quotations along with a DD for 1,000 drawn in favor of The
Registrar, JNTUK Kakinada payable at Kakinada are only eligible to participate in the
tender.
2.
E.M.D: The tender documents should be submitted along with earnest money
deposit 10,000 in the form of Demand Draft in favor of The Registrar, JNTUK
Kakinada payable at Kakinada. The Demand Draft pertaining to E.M.D. of
unsuccessful party will be returned.
3.
PRICES: The price should be quoted in Indian Rupees only and F.O.R. destination
inclusive of taxes, packing & forwarding charges, freight and delivery chargers. Items
on rate contract, if any together with the terms and conditions may please be
furnished.
4.
PAYMENT: 100% payment will be made within a reasonable time only after the
receipt of all items in good condition and installation as per given specifications and
after testing for satisfactory working and on receipt of the company’s invoice with all
supporting vouchers such as copy of A.P. Sales Tax or VAT Registration certificate etc.
No advance will be paid in any case either in part or in full.
5.
JNTUK, Kakinada has been registered with DSIR, GOI and exempted from customs
and central excise (copy of the certificate enclosed).
6.
ACCEPTANCE: It is not binding on the university/ institution to accept the lowest of
the tenders. The university/ institution reserves the right to place orders for
individual items with different tenderers.
2
7.
SPECIFICATIONS: Full specifications along with the description and MAKE should be
mentioned in the tender.
8.
Warranty/Guaranty:
tenderer.
11.
DELIVERY: The period of delivery at destination from date of placing orders is 6 WEEKS.
12.
VALIDITY: The quotations should be valid for at least 180 days.
13.
The Institution reserves the right to cancel the tender without assigning any reason.
14.
This University being Government educational institution is exempted from payment of
Central/State Excise Duty.
15.
Since the college is Government institution whatever conditions are applicable to any
Government institute shall be applicable even if not specified.
16.
Any tender that is received after due date will not be accepted. The university is not
responsible for any postal delay.
17.
Attach the List of Major Customers along with the tender.
18.
Any specific queries, communications, and references should be made only to, The Registrar,
JNTUK, Kakinada.
Warranty/Guaranty period should be mentioned by the
Sd/Registrar
Encl: Items with Description.
3
Institute of Science & Technology, JNTUK, Kakinada
Specifications of the items for
School of Avionics
Item
No.
A-1
Name
Avionics Data Bus
Product :
MIL-STD-1553B
interface card
Specifications
USB based 2 channel card Supporting BC,
multiple RT and MT functions with casing/
enclosure
Accessories (2 sets )
Each set contains
-
Quantity
2
2 port and 4 port bus couplers (1
each)
1553 transformer coupled I/O
cable with PL-75 connectors (3 ft)
Bus termination (1)
USB cable with screw locks (5ft)
D type mating connector (1)
User Manuals, driver software and demo
programs.
A-2
Avionics Data Bus
Product :
ARINC-429 Interface
card
USB based 4Rx/2Tx interface card with
casing/enclosure
Accessories (2 sets)
Each set contains
-
USB cable with screw locks (5ft)
D type mating connector
User Manuals, driver software and demo
programs.
4
2
Institute of Science & Technology, JNTUK, Kakinada
Specifications of the items for
School of Renewable Energy & Environment
Item
No
Name
Specifications
Quantity
Renewable Energy – Simulation Lab
E-1
Software:
ANSYS 15.0
Applicable to Energy –
Electromagnetics – Industrial
equipment & Rotating Machinery –
CFD solutions
Modeling, simulation, and analysis –
Professional - Licensed software
3 user
E-2
Software:
CATIA V6 3D
Applicable to solar, wind, wave etc.
Renewable Energy Systems - Product
Development
Modeling and design
Professional – Licensed software
3 user
5
Institute of Science & Technology, JNTUK, Kakinada
Specifications of the items for
School of Health Science & Research
Item
No.
H-1
H-2
Name
MOBILE
X-Ray
PORTABLE
SPIROMETER
Specifications
GENERATOR: DSP Controlled, High Frequency 4Kw
INPUT VOLTAGE : 185 V – 260 V, Single Phase
AC, 50Hz
KV RANGE : 40 kV to 100c kV in steps of 1kV
mA Range : 10mA to 100 mA,
mAs range : 0.1 mAs to 250 mAs
Exposure time : 10 msec to 10 sec
Indicator and controls : set kV, set mAs, exposure
ready & fault
X ray tube : stationary anode tube
Focal spot : 1.8 IEC 60336
Collimator :  160 lux at 1m from focal spot, 30 sec
auto light off
Maximum x ray field : 480mm X 480mm at 1m from
focal point
Tube head vertical rotation : <290 degrees
Tube head horizontal rotation : 360 degrees
Collimator rotation :-90 degree to + 90 degree
FVC, SVS AND MVV TESTS
Pre and post medication results
Internal memory for 2500 tests
Auto interpretation
Battery status indicator
PC connectivity for further viewing , reporting and
management of data
Technical specification:
Flow meter :
-10 to + 16 liters
Max volume 8 lts
Accuracy
± 1%
Tranducer bielectrical turbine cartridge
Turbine sensor
infrared interruption
Flow detection
volume differential
Data display
Graphs & measurements
Graphics Display
320x240 pixels
Power supply
Line power ~ 220 -240 V, 50Hz + 10 %
Power supply
AC/DC
Battery
12V/1.2 AH
PC mode
Communication interface
USB
Features
PC based spirometer, data download
facility,
6
Quantity
1
1
OPTIONAL
Disposable mouth pieces
PC/laptop, Desk Jet/Laser Jet Printer
H-3
H-4
H-5
PULSE
OXIMETER
TRANSCUTANE
OUS
ELECTRICAL
NERVE
STIMULATOR
BATH TUB
(STANDARD)
High brightness led display of NIBP,SPO2 and pulse
rate
Memory: built in flash memory
Visual and audio alarms, adjustable
Built in lithium ion battery
Suitable for adult, pediatric and neonatal patients
Specifications
NIBP
Method : oscillatory
Mode :manual / automatic/ continuous
Measurement range 25 – 260 mm Hg
Resolution
1mm Hg
NIBP Accuracy
± 5mmHg
Alarm: Systole/Diastole/Map
spO2
Measurement range 0% to 100%
Resolution
1%
Accuracy
± 2% (70% - 100%)
Alarm range
0 – 100%
Pulse rate
Measurement range 10 – 270mmHg
Resolution
1bpm
Accuracy
± 2 bpm
: Dual , Isolated between
Channels
MODE OF OPERATIONS :
Burst, Continous, Modulation
PULSE INTENSITY : Adjustable 0 – 80
Ma peak into 500 ohm
PULSE RATE : 2 Hz to 150 Hz
PULSE WIDTH : 30 uS to 260 uS
Wave forms : Asymmetrical, Bi phasic square pulse
Voltage : 0 -100 volts
Power supply : 9 volts battery
1
CHANNEL
Capacity 68 gallons
Dimensions : 48 inch Length X 32 inch width X 25
inch height
High glass acrylic surface
Smooth touch backing
Built in screw guides
7
3
1
H-6
HEAMATOLOGI Technical Specifications:
CAL ANALYSER Function: Automated
WBC
3-differential,
25
parameters with 3 color histograms (WBC, RBC, PLT).
Principal: Electronic impedance, SFT method for
haemoglobin.
Parameters: WBC, RBC, HGB, HCT, MCV, MCH,
MCHC, PLT, LYM%, LYM#, GRA%, GRA#, MID%,
MID#, PDW, MPV, PCT, RDW-CV, RDW-SD, PLCR, RCDW, LCDW and WBC, RBC, PLT three
histograms.
Throughput: HL-3124≥30T/H; HL-3124≥60T/H.
Analysis Mode: Optional venous blood, anticoagulant
blood and prediluted blood.
Sample Volume: Anticoagulant whole blood ≤9.6µL,
Anticoagulant capillary blood ≤9.6µL, prediluted
capillary blood ≤20µL, the sample volume for
repeating two times testing and avoiding second
sampling.
Automated Maintenance: Automated washing during
power on and power off, reducing the blockage rate.
Storage: Large quantity test results storage, at least 400
thousand test results with comprehensive information.
Extended SD memory supported.
Control Mode: Quality control mode of L-J, X-B and
X-r. Westguard quality control regulation.
Calibration Mode: Manual and automatic calibration
available. Fresh blood calibration available also.
Discriminator Function: Float and fix discriminator.
Manual adjust available
Display: TFT LCD Touch Screen
Input Mode: Standard mouse and keyboard. Optional
bar code reader
Print Mode: Internal high-speed thermal printer.
Optional connection with specified external printer.
English printouts.
8
1
H-7
H-8
PROFESSIONAL
MULTI
Features
PROGAM
 All information is displayed on a Profile Matrix
TREAD MILL
LED display console
 Feedback includes elevation, heart rate, time, speed,
calories and distance
Console:

Profile matrix

LED display
 3-Window LED Display
Console feedback:
 Elevation
 Heart rate
 Time calories
 Speed
 Distance
LACTATE
ANALYSER
Programs:
 22 Manual Walking courses
 3 Running courses
 3 Cardio
 3 Heart rate control
 2 Custom learn
 3 Fat burn
 3 Endurance
 3 Interval
Specifications:
 Power: 110 volts 60 hz
 Motor: 3.0 hp continuous duty
 Run belt: 19.5in x60in
 Running area: 19.5in x60in
 Rollers: 2.5in
 Motor control: PMW system
 Speed: 0.5 to 10mph
 Elevation: 0-15% 960 joules thrust motor
 Cushioning: 8-point elastomer system
 Floor space: 82in x 31in
 Weight capacity: 210 kg
Method : Enzymatic oxygen rate
Sensor : Clark-type amperometric oxygen electrode
Reaction temperature 30 °C
Display : 32 character backlit LCD
Printer : 16 column dot matrix, 1 line/sec.
Statistics Sequential, giving mean, S.D &C.V.
Interface :Serial data port, optional
Windows
software
Power : 100 -250 V AC, 12- 15 V DC,
60 VA
9
1
1
H-9
BIOCHEMISTRY
ANALYZER
ANALYTICAL PERFORMANCE
Precision :CV OF 2 % @ 2.5MMOL/L
Accuracy : Method comparison for whole blood
vs YSI 23L: y (Analox) = 0.98x + 0.055 mmol/L, r =
0.9991, n = 56
Linearity : 10 mmol/L (ca. 90 mg/dl)
for 7 µl samples
Features









Analytical Modes: kinetic, fixed time, end-point,
absorbance
Wavelengths:7
standard
filters:340,405,492,510,546,578,630nm,1
more
filter optional
Full open reagent system
Items can programmed, number of items not limited
Voice prompting, making the operation interesting
Windows operation interface, figure button, mouse
operation
Real time graph display and print
Lamp saving feature, longer lamp life
Large storage ability, up to1000,000 results
Technical Specifications

















Assay Method: reaction rate, endpoint, two-point,
double wavelength, coefficient, multiple standards,
blank reagent, blank sample, absorbance at fixed
point, Q.C, Q.C graph and turbidity
Temperature
System: PELTIER
temperature
control component, 25,30,37deg,accuracy: ±1deg
Light Source: 6V, 10W halogen lamp of more than
2000 hours’life time
GML Precision:±2nm
FWHM: ≤10nm
Stray Light:≤0.5%(absorbance≥2.5)
Absorbance Range:-0.214~3.000
Absorbance Linearity:±1%
Absorbance Repeatability:±0.001
Precision: ≤1%
Carry Over: ≤1%
Resolution: 1m Abs
Stability: ≤3mAbs/h
Flow Cell: permanent quartz flow cell, minimal
volume is 32uL,and disposable flow cell is
selectable
Sampling System: pressure auto releasing pumps
ensure the accuracy of suction volume
Absoption Volume:200uL~3000uL
Sample Volume:10uL~50uL
10
1








H-10
TRAVELLER
EEG
Operational System: Windows XP with 1GB
memory capacity
Display:10.1’LCD
Print: print standard test A4 test report
Interface:RS-232 serial port
Working Condition:Temperature:10-30deg,Relative
Humidity:20%-80%
Voltage: AC 85~264V,auto adapt according to the
input voltage
Power: ≤100W
Quality System: CE
General
Electrical
EEG
Size : 192 (L) x 136 (W) x 42 (H)
Weight : < 420 g
No. of Input Channels : 24
No. of Display Channels : 24
Photo Stimulator : High intensity white LEDs
Power Supply : USB Powered
Frequency Band Range : 0.1 to 100Hz
Input Impedance : > 10 M
Noise : < 1uV P-P
Input Range : ± 8 mV
CMRR : >95 dB
Sampling : 1024 Hz for at ADC, 256 Hz
for internal storage
A/D conversion : 16 Bit
Impedance Measurement : Automatic, built-in Yes
High Cut Filter (digital) : 0.5 - 100Hz
Low Cut Filter (digital) : 0.1 - 7Hz
Notch Filter (digital) : 50/60 Hz
Time Resolution : 7.5, 15, 30, 60 mm/s
Flash Rate : 1 - 60Hz
Operating Environment
Standard Accessories
Optional Accessories
0
Temperature : 5 to 45 C
Humidity : 5 to 95% RH (noncondensing)
0 Storage Temperature : 0 to 50 C
Respiration Card 1 No.
Electrodes Placement Card 1 No
EEG Paste 2 Jars
EEG Electrodes 50 Nos.
ECG Electrodes 2 Nos.
EMG Electrodes 2 Nos.
Photic Flash 1 Nos.
Photic Flash Flat Cable 1 Nos.
11
1
H-11
ECG
USB Cable 1 No.
Patient Ground Cable 1 No.
Event Marker 1 No.
User Manual 1 No.
Head Box. 1 No.
Camera
Capture Card
Audio Cable
Signal Power Supply Cable
General
Size : 216mm (L) x 147mm(w) x 61 (H)
Weight : < 820 g
PC Communication
Serial Interface RS 232 interface for data management
and ECG viewing/reporting (ECG PC
link software optional)
Electrical
Recharge Time : 3 to 4 hours for fully discharged
battery
Battery 7.4V- 2.2Ah Li-ion can give more than
50 ECG recordings on a single charge
ECG
Input impedance : > 10 MΩ on each electrode
Leads : Standard/ Cabrera
CMRR : > 90 dB
Dynamic Range : ± 4.25mV
Frequency Response : 0.05-150 Hz (-3dB) without
filters
Time Constant : 3.2 Seconds
A/D Conversion : 12 bits, 12 leads simultaneous
acquisition
Sampling Rate : 1600 samples/sec/channel
Paper Speed : 5, 25, 50 mm/sec
106 mm wide thermal paper in 20mm roll
Sensitivity : 5,10, 20 mm/mV
Filters Complete digital processing to reduce
mains interference, muscle tremors &
base line wander
LED Indicators Mains connected, low battery,
No Paper, loose electrode
Paper
Memory 10 seconds for all 12 leads.
Multiple patients (Optional)
Power Supply : 12 V, 1 A DC Adapter
Defibrillation protection : Internal at apparatus
Pace maker detection : ≥ ± 2mV/≥ 0.1 ms
Printout : 4/6 Channel options
Flexible reporting Reports of stored ECG can be copied
for print with new Selection
Of filters, speed and sensitivity.
12
1
H-12
PC Audiometer
Operating Environment
Temperature 0 to 45 C
Humidity 5 to 95% RH, non-condensing.
Storage 0 to 55 C
Standard accessories
Patient cables
1 Nos
Gel bottle
1 Nos
Limb electrodes
4 nos
Chest electrodes
6 nos
Carry bag
adapter
Optional accessories
Pediatric electrodes
Rechargeable battery
Power Supply : Built in power supply. 100-240V, 5060Hz, Max 0.7 A
Display : 8.4 inch high resolution color display, 800 x
600 pixels
CALIBRATION :
Air Conduction TDH39: ISO 389-1 1998, ANSI S3.62010
DD45: PTB/DTU report 2009
HDA200: ISO 389-8 2004, ANSI S3.6-2010
HDA280 PTB report 2004
E.A.R Tone 3A/5A: ISO 389-2 1994, ANSI S3.6-2010
BONE CONDUCTION : Placement: Mastoid
Transducers
:TDH39 Headband Static Force 4.5N
HDA280 Headband Static F
E.A.R Tone 3A/5A:
CIR 33
PATIENT RESPONSE SWITCH :Two push button.
PATIENT COMMUNICATION :Talk Forward (TF)
and Talk Back (TB).
Special tests/test battery : Stenger
ABLB
Langenbeck (tone in noise).
Masking Level Difference
Pediatric Noise Stimuli
Multi Frequency
High Frequency
Speech from Hard-drive (Wave Files)
SISI ,Master Hearing Aid ,Hearing Loss Simulator
,QuickSIN(tm), Auto threshold:
o Hughson Westlake
o Békésy
13
1
TONE :125-20000Hz separated in two ranges 1258000Hz and 8000-20000Hz. Resolution 1/2-1/24
octave.
Pediatric Noise : The bandwidth is frequency depended
125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz
17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz
Wave file :44100Hz sampling, 16 bits, 2 channels
Warble Tone :1-25 Hz sine.1 to 25% modulation with
½dB step
MASKING: Automatic selection of narrow band noise
(or white noise) for tone presentation and speech
noise for speech presentation.
Narrow band noise:
IEC 60645-1 2012, 5/12 Octave filter with the same
centre frequency resolution as pure
Tone.
White noise:
80-20000Hz measured with constant bandwidth
Speech Noise.
IEC 60645-2:1993 125-6000Hz falling 12dB/octave
above 1KHz +/-5dB
Frequency range :125Hz to 8kHz (Optional High
Frequency: 8 kHz to 20 kHz)125Hz, 250Hz, 750Hz,
1500Hz and 8kHz may freely be deselected
SPEECH :
Frequency Response:
(Typical) Frequency Linear [dB] Ffequv [dB]
[Hz] Ext.
Sign1
Int. Sign2 Ext.
Sign1
Int. Sign2
TDH39
(IEC 60318-3 Coupler)
125-250 +0/-2 +0/-2 +0/-8 +0/-8
250-4000 +2/-2 +2/-1 +2/-2 +2/-2
4000-6300 +1/-0 +1/-0 +1/-0 +1/-0
DD45
(IEC 60318-3 Coupler)
125-250 +0/-2 +1/-0 +0/-8 +0/-7
250-4000 +1/-1 +1/-1 +2/-2 +2/-3
4000-6300 +0/-2 +0/-2 +1/-1 +1/-1
E.A.R Tone 3A
(IEC 60318-5 Coupler)
250-4000 +2/-3 +4/-1 (Non linear)
B71 Bone Conductor
(IEC 60318-6 Coupler)
250-4000 +12/-12 +12/-12 (Non linear)
14
2% THD at 1000 Hz max output +9 dB
(increasing at lower frequency)
Level range: -10 to 60 dB HL
o Ext. Sign: CD input 2. Int. Sign: Wave
files
Free Field output
(non-powered) :Power amplifier and loudspeakers
With an input of 7 Vrms – Amplifier and loudspeakers
must be able to create a Sound
Pressure Level of 100 dB in a distance of 1 meter – and
meet the following requirements:
Frequency Response
125-250 Hz +0/-10 dB
250-4000 Hz ±3 dB
4000-6300 Hz ±5 dB
Total Harmonic Distortion
80 dB SPL < 3%
100 dB SPL < 10%
INTERNAL STORAGE :1000 patients and 50.000
sessions/measurements/audiograms
Signal Indicator(VU) :Time weighting: 300mS
Dynamic range: 23dB
Rectifier characteristics: RMS
Selectable inputs are provide with an attenuator by
which the level can be adjusted to the indicator
reference position(0dB)
DATA CONNECTIONS FOR
CONNECTION OF ACCESSORIES :
4 x USB A
1 x USB B for PC connection (compatible with USB
1.1 and later)
1 x LAN Ethernet
EXTERNAL DEVICES (USB):
Standard PC mouse and keyboard (for data entry)
Supported printers: Please contact local distributer for a
list of approved PC printers.
INPUT SPECIFICATIONS:
TB 212 uVrms at max. Gain for 0dB reading
Input impedance : 3.2Kohm
Mic.2 212 uVrms at max. Gain for 0dB reading
Input impedance : 3.2Kohm
CD1/2 16mVrms at max. Gain for 0dB reading
Input impedance : 47Kohm
TF (side panel) 212uVrms at max. Gain for 0dB
reading
Input impedance : 3.2Kohm
TF (front panel) 212uVrms at max. Gain for 0dB
reading
Input impedance : 3.2Kohm
15
Wave files Plays wave file from internal SD card
OUTPUT SPECIFICATIONS:
FF 1/2/3/4 Line output 7Vrms at 2Kohms load
60-20000Hz -3dB
FF 1 / 2 / 3 / 4 –
powered
4x20W (only 2x20W can be used by software at the
moment)
Left & Right 7Vrms at 10 Ohms load
60-20000Hz -3dB
Ins. Left & Right 7Vrms at 10 Ohms load
60-20000Hz -3dB
HF Left & Right 7Vrms at 10 Ohms load
60-20000Hz -3dB
HLS 7Vrms at 10 Ohms load
60-20000Hz -3dB
Bone 1+2 7Vrms at 10 Ohms load
60-20000Hz -3dB
Ins. Mask 7Vrms at 10 Ohms load
60-20000Hz -3dB
Monitor headset (side
panel)
2x 3Vrms at 32 Ohms / 1.5Vrms at 8 Ohms load
60-20000Hz -3dB
Assist Mon. Max.3.5Vrms. by 8 Ω load
70Hz-20kHz ±3dB
OPERATION ENVIRONMENT:
Temperature: 15-35°C
Re. Humidity: 30-90% Non condensing
Ambient pressure: 98-104 kPa
TRANSPORT AND STORAGE :
Transport temperature: -20-50°C
Storage temperature: 0-50°C
Re. Humidity: 10-95% Non condensing
16
Institute of Science & Technology, JNTUK, Kakinada
Specifications of the items for
School of Pharmacy
Item
No.
P-1.
P-2.
Name
Specifications
1. Binocular Microscopes with Battery backup
2. Total Magnification 40X – 1000X
3. Viewing Head: Compensation free Binocular side
and top of head at 30°-360° rotatable.
4. Eye Piece: WF 10x
5. Nose piece: Quadra pole Nose piece
Binocular
6. Objectives: Achromatic objectives
4x,10x,40x,100x,999(oil)
Microscopes
7. Focus: Co – Axial coarse and fine adjustment
8. Stage: Double layer mechanical stage 140x140mm,
moving range 75x50mm
9. Illumination: LED light with battery back up.
10. Condensor: Abbe type NA 1.25 with IRIS
Diaphragm and Filter
1. UV – 3000+ Double Beam UV - VIS
Spectrophotometer with variable Slit width 0.5 to 5
nm with Automatic 8-Cell Changer and UV-WIN
Software. Includes 4 Pairs of quartz cell 10 mm.
Supplied with the following:
a). Microprocessor based, high resolution LCD
display and soft keypad - for operation on
220V/50Hz.
b). Complete control through PC with UVWIN
Software
c). Double Beam optics with holographic grating in
Czerny-Turner mounting, Monochromator High
Double Beam UV
intensity Tungsten Halogen and Deuterium lamp
Visible
with automatic changeover.
d). High sensitivity matched pair Silicon
Spectrophotometers
Photodiode detector. Compliance with all
Pharmacopoeia requirements.
e). Built in validation program diagnostic and
security functions.
f). Upgradability option: System can be any time
upgradeable to Peltier & Sipper attachments
g). Operational modes:i) Standard Photometric ii) Quantitative
iii) Spectrum scans iv) Kinetics [Enzymatic] Studies
v) DNA and Protein.
h). UV-Win software adds functions such as 3D
Spectrum analysis, GLP/GMP/Pharmacopoeia
17
Quantity
20
03
P-3.
P-4
IC.FR protocol.
i). Large Sample compartment compatible with
wide range of accessories .
j). Scan Speed: Very Slow, Slow, Medium & Fast
in the software.
k). Compact design with small footprint
l). first & second order derivatization
m). Dust Cover for the main instrument.
n). 5 KVA Servo Stabilizer with surge suppressor.
o). Branded PC with 17” TFT Monitor & Laser Jet
Printer
 -Parameters: Max.27 Whle Blood Parameters; 7
Body
fluid
reportable
parameters;
DC,WBC,RBC,HGB,HCT,MCV, MCHC,RDWCV, RDW-SD, PLT, MPV, PDW, PCT and
Histogram for WBC, RBC, PLT, Lymph#, Mid#,
Gran#, Lymph%, Mid%, Gran%
Cell Counter (Auto
 Throughput: 60 samples per hour
Hematology Analyzer)  Sample volume: closed mode - 40µl
 Display: Color LCD display
 Printout: Thermal recorder, 50mm width paper,
multitude of printout formats, printer optional
 Operating Environment:
Temperature: 10º C~35º C
Humidity: 20% ~85%
 22 cpm A4 and 10 cpm A3 mono copier.
 Optional GDI printer functionality
 32MB RAM for full digital functionality
 Time to first copy: 5.9 seconds from power on
 Fastest in class warm up time of 20 seconds
 Optional duplex
 Scanning
 Paper capacity of up to 1,250 sheets
 Long life components, easy maintenance
 Copy features: Auto reduction/enlargement,
Booklet creation, Edge erase, ID Card Copy,
Image shift, Invert image, Margin shift, Mirrored
Photocopier
image, N-up, Negative image, Reduce/Enlarge,
Scan once-print many, Stored job setting, Touch
screen interface
 Reduce/Enlarge: From platen: 25 – 400 %
From document handler: 25 – 400 %
 Reduce/Enlarge increments: 1 %
 All-round functionality: copying, printing,
scanning and faxing
 Sharp and high-quality colour output with new
PXP toner
 Excellent productivity at 20ppm in both colour
and B/W
18
01
01
Institute of Science & Technology, JNTUK, Kakinada
Specifications of the items for
School of Nanotechnology
Item
No.
N-1
Name
Spectrophotometer
Specifications
















It should be capable of
measuring with sample volume
– 0.5μl to 1ul, Absolutely no
cuvettes, capillaries or TIPS or
plates or Membrane format for
micro volume
They should be provision to use
cuvettes for 20 ul ,1 ml, 1.5 ml,
3 ml with heating facility and
stirrer rpm 150-850
Should have long path length of
1 mm
And should be having short path
length (for high concentration
measurement) of 0.05mm
Technology should be Open
system
Should be capable of measuring
50-60 times more concentrated
samples than normal
spectrophotometer
Detector: 2048-element linear
silicon CCD array
Absorbance Accuracy: 2% (at
0.76 absorbance at 257 nm)
Sample Pedestal Material of
Construction: 303 Stainless Steel
& Quartz Fiber
Absorbance Range: 0.02-300
(10mm equivalent absorbance)
Wavelength Range: 190-840 nm
Light Source: pulsed Xenon
flash lamp
Measurement Cycle should not
exceed more than 10 seconds
100% sample recovery with no
contamination.
Simple and easy sample cleaning
facility should be available
System should not require any
adaptors or any other accessories
while taking readings.
19
Quantity
1

N-2
Differential
scanning
calorimeter (DSC)
Detection limit:
Upper limit - ds
DNA 15000ng/μl,
Lower limit - ds DNA 2ng/μl
 Software
 Nuclic Acids: ds DNA,ss DNA,
RNA
Protein: Bradford, Lowry,
BCA, BSA, IgG, Lysozyme,
Micro Array:
 Cell Culture
 General UV/Vis
 Software tool: System diagnostic
tool.
 Instruments are approved to CE
and UL/CSA standards.
 System should be quoted with 5
years warranty, and 1 pair of
Quartz cuvettes of all sizes at
free of cost.
Temperature range : - 150 °C to 725°C
Temperature accuracy : 0.1 °C
Temperature precision : 0.1 °C
Heating rate : 0.1 to 200°C / min in 0.1°
interval
Sensitivity : < 0.5 µW
Stability : < 1 m W ambient to 550°C
Principle: Heat Flux Plate
Heat flux plate material : Chromel or
Constantan
Sample and reference thermocouples :
Chromel/Alumel (Type K)
Furnace thermocouple : Type K
Typical rate : 5 to20°C /min
Purge Gas Flow: Up flow
Heating rate(℃/min): 0.1 to 200
Standard Cooling system: Water
Cell design: Triple cap covering
Cell material: Silver
Should be capable to analyze
· Glass transition
· Melting points
· Crystallization time and temperature
· Boiling points
· Thermal stability
· Purity
· Degree of cure
· Rate of cure
· Oxidative stability
· Heat of fusion
20
1
· Heat of reactions
· Heat capacity
· Effects of additives
· Polymer blends
· Effect of recycled materials
Multi-Data Analysis & Acquisition
System
Real-time color display of data
collection
Auto and manual scaling
Time vs Temperature profiles
First and second order derivative plots
Analysis save feature
Background data collection
On-line help manual
Individual segment display
Annotation and drawing tools
Copy to clipboard function
Post collection editing
Multiple curve/module overlay
Split screen zoom mode
Quadratic temperature and ordinate
correction
ASCII export
Data smoothing
Baseline file subtraction
Y-axis shift operation
Subfile operations
Custom display configuration
User selectable units
Accessories :
* Al Hermetic (Encapsulating) Sample
Pans for Liquid Sample (Box of 200),
should be used below 600℃.
* Al Hermetic(Encapsulating) Sample
Pan Lids with Pin Hole (Box of 20),
should be used when the sample is
vaporized during the experiment
*Al Non-Crimping Sample Pans (Box
of 200) , should be used at below 600℃.
*Al Crimping Sample Pans , Cu Sample
Pans for High Temperature (Box of
200), should be used up to 725℃; Pt
Sample Pan for High Temperature, 1ea ,
should be used up to 725℃
21
EXCISE DUTY EXEMPTION – ANNEXURE – IV
22
23
Download