TECH n LIFE . EU

advertisement
HYUNDAI Photovoltaic Inverter
HYUNDAI HEAVY INDUSTRIES CO., LTD
Electro Electric Dept.
0/17
- Contents 1. Photovoltaic energy system & business
2. Photovoltaic power generation system
3. Photovoltaic Inverter technology
4. Photovoltaic Inverter of HHI
5. Application of HHI Solar Energy System
1/17
1. Photovoltaic energy system & business
(1) Value Chain for Photovoltaic Energy
Poly Silicon
Ingot/Wafer
PV Cell
Upstream
▪ Original material
for Ingot
2/17
▪ Silicon Melting
▪ Ingot Growing
PV Module
System
Downstream
▪ Cell Production
▪ Module Production
▪ PV Array, PV Inverter,
Battery, Support,
Monitoring system,
Installation
2. Photovoltaic power generation system
(1) Composition of Photovoltaic Energy System
Grid
Load
PV Array
PCS
Monitoring System
Data
Transmission
< Block Diagram for Grid-connected Photovoltaic energy system >
▪ PV Array (Solar Module Panel) : Modules are used suitably in series or parallel connection.
▪ Peripheral components (BOS : Balance of System) : Support for module installation, Battery
▪ Power Conversion Device (PV Inverter) : PCS (Power Conditioning System)
- PCS converts DC power generated in PV array to AC power.
3/17
2. Photovoltaic power generation system
(2) Classification of Photovoltaic Energy System
1) Grid-connected System
- The output of solar system is connected to main grid.
- The shortage power is supplied from grid, the surplus power is re-supplied to grid.
- Used for House, Building, Grid Reinforcement, Power Generation (MW Level)
2) Stand-alone System
- Isolated from grid, Used to small capacity load in rural area without grid.
- The power storage device (ex. the battery) is necessary when the generation is impossible.
3) Hybrid System
- System which is combined with other generation system such as wind turbine generator,
diesel generator etc.
- Used in the island, isolated area, military equipment without commercial power
4/17
2. Photovoltaic power generation system
(3) Concept of Solar Energy System for house use
1) Grid-connected system
PV Array
Inverter (Grid-connected)
DC250∼850V
Grid
AC/220V
2) Stand-alone system
PV Array
Inverter
AC
Battery
5/17
3. Photovoltaic Inverter technology
(1) Considerable feature for photovoltaic inverter
1) Change of the environmental condition
- Solar radiation, Surface temperature of PV array, Shadow by obstacle or cloud
→ Environmental condition is changed frequently and rapidly.
2) Response for the environmental change
- Tracking for most efficient point of PV array
: Maximum Power Point Tracking (MPPT)
3) Synchronized operation with grid
- Synchronized operation with grid voltage
4) Protective function
- Inverter protection from grid fault condition
- Grid protection from the fault condition of a solar energy system
6/17
3. Photovoltaic Inverter technology
(2) Design topology for PCS Power circuit
Design
Topology
Low frequency
Transformer Type
High frequency
Link type
Transformerless
Type
7/17
Circuit Diagram
Feature




Easy isolation & Simple circuit
Low efficiency for small capacity
Big size and heavy weight
Method applied for large capacity models
PV
Array





Small size & light weight
Complex circuit for isolation
High cost
Efficient improvement is difficult.
Not applicable for large capacity models
PV
Array





Small size & light weight
High efficiency
Low cost
High reliability for DC current input
Not applicable for large capacity models
PV
Array
3. Photovoltaic Inverter technology
(3) Requirements for Photovoltaic Inverter
1) DC input voltage range
- Wide range of input voltage → Various kind of serial connection for solar module
(250Vdc ~ 850Vdc)
- 200Wp Solar module(6 inch Cell : 54 ea) → DC Voltage 26Vdc∼ 27Vdc
Serial & parallel connection of module → Advanced capacity, voltage
- 3kW PCS input voltage range : 250Vdc ~ 600Vdc
200W × 15ea serial connection → very useful to household system
2) Cooling Method & Protection Degree
- 3kW PCS : Natural cooling (without Fan) → No Noise
- When PCS is independently established to outdoor, it is necessary to have high protection degree
for the dust and water. (3kW PCS : IP54)
3) Detecting for DC current input
- DC current input with the AC grid output can lead to the abnormal condition or damage to PCS.
- Within 1%, detecting time : within 0.5 sec
8/17
3. Photovoltaic Inverter technology
4) Protection for grid abnormal connection
- PCS protection for the abnormal or breakdown condition to minimize the range of accident.
- Detecting for Over voltage, Under voltage, Over frequency, Low frequency
5) Noise reduction
- very important to indoor type
- Switching frequency → over audio frequency
- Without fan → No Noise
- Air Cooling : Fan speed control according to the load
6) European Efficiency
- Considering for the operation from low load condition to full load condition
- Efficiency with 5%, 10%, 20%, 30%, 50%, 100% load condition.
→ Total power efficiency is produced.
- European Efficiency
ηeuro = 0.03 x ηeuro5%Pn + 0.06 x ηeuro10%Pn + 0.13 x ηeuro20%Pn + 0.1 x ηeuro30%Pn
+ 0.48 x ηeuro50%Pn + 0.2 x ηeuro100%Pn
9/17
3. Photovoltaic Inverter technology
7) MPPT (Maximum Power Point Tracking) control
- Because the output characteristic of PV array changes according to solar radiation and surface
temperature, maximum output power point changes. (solar radiation increases → output power
increases, temperature increases → output power decreases)
- Watching and following function to operate at Maximum power point.
- Algorithm : Perturbation and Observation (P&O), Incremental Conductance (IncCond)
◈ Change of the solar module output characteristic (Temperature and solar radiation quantity)
10/17
3. Photovoltaic Inverter technology
8) Anti-Islanding Function
- Islanding Operation : PCS continue to operate under power failure or grid accident.
- Safety Problem : Electric Shock
- It is important to synchronize between grid and PCS voltage.
- When the power failure or grid accident is occurred, PCS must detect the fault condition
and stop its operation.
- Detecting for islanding operation : Passive & Active Method
a) Passive Method
▪ Detecting from grid parameter value (Voltage, Frequency)
▪ Power mismatch → voltage & frequency variation → Islanding condition
b) Active Method
▪ Detecting from response characteristic for the intended grid fluctuation.
▪ PCS output voltage fluctuation, frequency transfer, reactive power addition, etc
▪ Very useful method but very complex
▪ Unstable : Non-detection zone
11/17
3. Photovoltaic Inverter technology
9) Standby power
- Minimum standby power → Higher efficiency
10) Weight
- Size & Weight is very important. (Small size & Light weight)
11) Communication & Monitoring system
- Instantaneous power and accumulated power, Monitoring system for watching
whether the system operates correctly.
- Communication condition for using a PC (Personal Computer) network.
12/17
4. Photovoltaic Inverter of HHI
(1) Photovoltaic power generation system business of HHI
1) Photovoltaic energy business
- Poly Silicon, cell, module, PCS, system : Total solution for solar energy
- Large scale investment
- Expansion in module production line : 70MW → 150MW (2009)
- Expansion in cell production line : 60MW → 330MW (2009)
- Large scale power plant (MW) & System business for foreign countries
2) Photovoltaic Inverter business
- Design experience and know-how in the Industrial inverter, UPS, Electric Vehicle, Electric
components for rapid electric railway → Basic technology of PCS
- Various products from small capacity(3kW) to large capacity(250kW) - Series
- Additional models are under development. (10kW, 30kW, 200kW, 500kW, 1MW)
- Continuous development and version up for World No.1 Brand
- Perfect product by making a verification test in actual field area. (HHI Solar Park : 500kW)
- Package with our solar module and supply for large scale power plant construction
(100kW, 250kW, 500kW, 1MW)
13/17
4. Photovoltaic Inverter of HHI
(2) Photovoltaic Inverter model list of HHI
1) 3KW PCS (Transformerless type)
- Supply for house in Korea
- Protection degree : IP54 (Outdoor)
- 1st PCS certificate in Korea (EMI/EMC)
2) 10KW PCS (Transformerless type)
- Supply for commercial building
- Simple & light weight (Project with national agency)
3) 12.5KW PCS (Built in transformer)
- Supply for commercial building, Small size of power plant
- Small size, Applicable to outdoor with option (IP43)
4) 50/100KW PCS (Built in transformer)
- Small & Middle capacity (50KW, 100KW, 200KW System)
- Launched in Korea (2009. 5) / CE Certificate schedule (2009. 8)
5) 250KW PCS (Built in transformer)
- Supply for large capacity System
- Under site test at our solar park in Korea (500KW )
- Will be launched (2009. 6)
6) 500KW/1MW PCS (Under Development)
- Supply for very large capacity System
- Development(2010. 6), Launch (2010. 12)
14/17
4. Photovoltaic Inverter of HHI
(3) HHI Strategy for PV Inverter
- Various products from small capacity(3kW) to large capacity(250kW) – Line-up and Series
- Continuous development and version up for World No.1 Brand
- Perfect product by making a verification test in actual field area (Solar Park at Eum-Seong, Korea)
- Package with our solar module and supply for power plant construction
(4) Development model of HHI PV Inverter
Model
HPC-003SL
HPC-012HT
HPC-050HT
HPC-100HT
HPC-250HT
Rated
Capacity(kW)
3kW
12.5kW
50kW
100kW
250kW
Development
State
Launched
(2007)
Launched
(2008)
Design Concept
Transformerless
Product
Target
Built in transformer
1) Low Price
15/17
Launched (2009)
2) High Efficiency
3) Reliability
5. Application of HHI Solar Energy System
 Business for Power Generation
ASAN Medical Center (Seoul, Korea)
- 147kW System
16/17
5. Application of HHI Solar Energy System
 Business for power generation
1. GESTAMP(Spain Fuente Alamo, 26MW)
3. Hae-nam, Solar power plant(1.2MW)
17/17
2. Jang-heung, Solar power plant(104KW)
4. Jeong-eup, Go-chang, Solar power plant(3.0MW)
Download