Uploaded by Sergey Zaytsev

mPOD3 rev-03 3-19-07

advertisement
EDHG Products
3
mPOD ™ Vibration/Pressure/Temperature Gauge
Designed as a permanently installed gauge, the mPOD3 gauge transmits a proprietary protocol when
addressed. Using an addressable scheme allows for multiple mPOD3 gauges or combinations of mPOD3
and mPOD2+ gauges to be powered and communicate on the same, single, conductor line. In addition to
transmitting both pressure and temperature data, continuous monitoring of the gauges head voltage
allows for basic diagnostics of cable integrity during the life of the installed equipment.
Incorporating all metal-metal seals assures life of asset operation. Stringent testing on all eP/Weatherford
gauges adds to the reliability and expected longevity in the permanently installed application. The
calibration and verification testing assures that the gauge meets the accuracy specifications determined
for the design.
Vibration data measured consists of Grms and frequency. The vibration parameter of in-well performance
can assist in the diagnostics and proactive decision process with tubing wear or rod parts. In addition to
rod pumping wells, gas wells may benefit from the mPOD3 enhanced measurement capability to
understand flow induced vibrations on the production string.
mPOD³ Gauge Specifications
Temperature
Gauge Type
Integral to pressure
Range
59°F to 257°F
Accuracy
+/- 1.8°F
Resolution
0.1°F
Pressure
Gauge Type
Piezo resistive (silicon on insulator)
Range
0-3000 psi, 0 – 5000 psi, 0-7,500 psi, 0-10,000 psi
Accuracy
0.075% FS (typically 0.05% FS)
Resolution
0.002% FS
General Specifications
3
Number of mPOD Gauges on a Single Conductor
Cable or Combination of mPOD2+ & mPOD3 Gauges
6
Accuracy
Pressure: 0.075% FS, temp: +/-1.8°F
Drift
< 6 psi/yr, typically <2 psi/yr
Resolution
Pressure: 0.002% FS, temp: 0.1°F
Cable Length
Unlimited (compliance test @ 20,000 ft)
Sensitivity
Equal to resolution (calibrated repeatability)
Power Consumption
54 mA
www.ep-solutions.com Œ info@ep-solutions.com
©2006 eP/Weatherford, Kingwood, TX
mPOD3_rev03_3-19-07
Page 1 of 3
Vibration Specifications
Force of Acceleration Withstanding (G)
Continuous at 30 G, peak at 100 G
Shock Withstanding
1 kg force (2.204 lbs force): all axis
Frequency Withstanding
0 – 2 khz
Frequency
0-400 hz
Grms
0-30 G
Material Specifications
Transducer Body & Isolation Diaphragm Material
Hastalloy C276™
Pressure Housing, Cable Adapter & Union Material
Stainless steel (optional: Inconel 718, 825, 925™,
Hastalloy C276™)
mPOD³ Gauge Components
Gauge
P/N
1.5K mPOD3
Carrier/Adapter
TEC
TD-PGC - Casing/Tubing
SSM-DA - PPB
TEC
TD-PGC - Casing/Tubing
SSM-DA - PPB
P1309-15900
3
3K mPOD
P1310-900
5K mPOD3
P1311-5900
7.5K mPOD3
P1312-75900
3
10K mPOD
P1313-75900
1.5K mPOD3 (Inc™825)
P1309-INC-15900
3K mPOD3 (Inc™825)
P1310-INC-900
3
Cablehead
5K mPOD (Inc™825)
P1311-INC-5900
7.5K mPOD3 (Inc™825)
P1312-INC-75900
10K mPOD3 (Inc™825)
P1313-INC-10900
Cablehead
P/N
TEC (Standard)
P102046-300SP
TEC (Standard) (Inc™825)
P102046-INC-3SP
Adapters
P/N
Carrier/Adapter
Casing Sensing
P102046-500SP
TD-PGC - Casing/Tubing
www.ep-solutions.com Œ info@ep-solutions.com
©2006 eP/Weatherford, Kingwood, TX
Carrier/Adapter
TD-PGC - Casing/Tubing
SSM-DA
TD-PGC - Casing/Tubing
SSM-DA
mPOD3_rev03_3-19-07
Page 2 of 3
SSM - Casing/Tubing
Casing Sensing (Inc™825)
P102046-INC-5SP
Tubing Sensing
P102046-600SP
Tubing Sensing (Inc™825)
P102046-INC-6SP
PSI Port Bulkhead
P102046-700SP
TD-PGC - Casing/Tubing
SSM - Casing/Tubing
TD-PGC - Casing/Tubing
SSM - Casing/Tubing
TD-PGC - Casing/Tubing
SSM - Casing/Tubing
SSM / Casing
Notes
www.ep-solutions.com Œ info@ep-solutions.com
©2006 eP/Weatherford, Kingwood, TX
mPOD3_rev03_3-19-07
Page 3 of 3