Schedule for Electrical Maintainance Work at HO

advertisement
SCHEDULE FOR ELECTRICAL MAINTENANCE WORK AT
KTDC- REGISTERED OFFICE
Sl No
1
a
b
c
2
3
a
b
4
5
6
7
8
Qty Description Wiring & Accessories
Supply and wiring light points / exhaust fan points using
1.5sq.mm PVC insulated copper wire through recessed /
surface mounted 20mm dia 1.5mm thick PVC conduits/ good
quality capping casing with No. 14 SWG Copper wire for
continuous earth with all specials including supply and fixing 3
plate ceiling rose / 10A connector, 6A modular switch fitted
on factory made MS box etc complete in all respect as per
standards.
5 One Point controlled by one, one way switch.
1 6A Plug points in combined positions.
1 6A Plug points in independent positions.
Supply & providing 6/16A plug point , including fixing 6/16A
modular type plug socket (2 in 1) controlled by 16A switch
1
mounted in a suitable factory built MS box with earthing
facilities as per standards. Supply and providing rigid PVC conduits with specials
confirming to IS 9537/1983 on surface / concealed position
complete (for circuit mains / power plugs / telephone / other
utilities)
20mm dia 1.5mm thick, ISI Marked
25
25 25mm dia 1.5 mm thick, ISI Marked
Supply and wiring 3 runs of 1.5Sq.mm. PVC insulated copper
15 wire through the existing PVC conduits / capping casing (for
circuit mains)
Supply and wiring 3 runs of 2.5Sq.mm PVC insulated copper
15 wire through the existing PVC conduits / capping casing (for
circuit mains)‐
Supply and wiring 3 runs of 4 Sq.mm PVC insulated copper
15 wire through the existing PVC conduits / capping casing (for
circuit mains)‐
System Protection ‐ DBs & Accessories
Supply and fixing of 6A to 32A, SP, 10kA C Curve MCBs of
3
approved make and good quality.
Supply and fixing of 63A, 4P, 30mA RCCB of approved make
3
and good quality.
Rate
Unit E
E
E
E
m
m
m
m
m
E
E
Amount 9
20
10
3
11
1
12
1
13
1
14
5
5
15
8
8
16
2
2
17
5
5
Supply and laying No. 10 SWG Cu wire using suitable lugs,
brass nut / bolt etc complete.
Supply and providing 6 mm thick electrical grade chequered
type rubber mat to withstand 3.3 KV dielectric strength
conforming to IS 5429/ 1969.
Panel meters & accessories
Supply & replacing damaged ( 0 ‐500V ) 90 degree deflection
scale Analog panel mounted AC Voltmeter of size 96 x 96mm
in the existing panel.
Supply & replacing damaged CT Operated ( 0 ‐ 100A ) 90
degree deflection scale Analog panel mounted AC Ammeter of
of size 96 x 96mm in the existing panel.
Supply & replacing damaged 100/5A Accuracy CL 1.0 5VA
metering CT in the existing panel.
Illumination
Supply & providing 28W, 4feet T5 lamp fittings suitable for
continuous operation with THD <10%, power factor >0.98,
RoHS compliant, duly wired up for use on 230 V AC supply
including tubelight and all other accessories required for
fixing etc. complete of good quality and approved make.
Supply
Labour
Supply & providing PLS 11W 2P CFL lamps in the existing 2x11W ceiling mounted type fittings.
Supply
Labour
Cooling, Fresh Air / Exhaust arrangements.
Supply & Providing 450mm Heavy duty exhaust fan of good
quality & approved make.
Supply
Labour
Supply and providing 150mm Light Duty Exhaust fan of good
quality and approved make.
Supply
Labour
TOTAL
m
sqm
E
E
E
E
E
E
E
E
E
E
E
Download