PRODUCT DIRECTORY 2014

advertisement
PRODUCT DIRECTORY
2014
TODAY’S IRRIGATION SYSTEMS are designed to last for decades. While sprinkler heads and
other components may be upgraded over time, the pipe and wire used in a system must continue to perform
reliably, year after year.
For over 20 years, professionals have specified high-quality products from Regency Wire & Cable for all
irrigation and landscape lighting applications.
Regency’s line-up of solidly-constructed and carefully-tested wire and cable products includes solutions for
irrigation zone wiring, central control cable, decoder cable and system grounding.
All Regency products are manufactured in the United States at our vertically-integrated facility in Sikeston,
Missouri. Beginning with top-grade raw copper, every step of manufacturing is handled in-house using
state-of-the-art equipment and monitored by a dedicated team of talented technicians. An on-site laboratory
tests samples from every production run, assuring that we meet or exceed all UL and NEC requirements as
well as our own higher-level standards.
In addition to providing outstanding products, Regency continually sets the industry benchmark for personalized
service. At the factory and in the field, Regency’s veteran team of technical specialists, sales representatives and
customer support personnel provides irrigation consultants, engineers, architects, distributors and contractors
with knowledgeable, hands-on support.
The Regency Advantage: Helping Our Customers Be Successful
Availability: Unmatched in-stock inventory of all irrigation and low voltage lighting wire and cable
for fast, same-day shipment.
Total Solutions: From control wire to manufacturer-specific communication and decoder cables,
Regency can supply all of the wire, cable and grounding solutions for systems of all sizes.
Personalized Service: Friendly, knowledgeable service from a dedicated team of professionals
who understand the industry and are committed to their customers’ success.
Technical Know-How: Our veteran team understands project needs and can help you in
specification and field troubleshooting.
Customization: Our in-house capabilities allow us to custom-manufacture products to your
specific requirements.
RoHS Compliance Statement
On January 27, 2003 the European Parliament and the Council of the European Union authorized Directive 2002/95/EC on the restriction of the use of
certain hazardous substances in electrical and electronic equipment. This new directive, also referred to as RoHS (“ro-has”) requires that manufacturers
reduce usage of six hazardous substances to minimum acceptable levels by July of 2006.
The six substances affected are:
• Lead (Pb)
• Mercury (Hg)
• Cadmium (Cd)
• Hexavalent chromium (Cr+6)
• Polybrominated biphyenyl (PBB)
• Polybrominated diphenyl ether (PBDE)
RoHS
Compliant
Regency Wire & Cable is pleased to announce that its product line is rapidly becoming RoHS compliant. As you view the products in this wire directory look
for the RoHS compliant logo to determine if the product you’re interested in meets the requirements of this directive.
Underground Low
Energy Circuit Cable
PVC Insulation, 30 V Rating
Part #
Desc.
Wt/1000’
18UF(C)(P)
18 Solid
16UF(C)(P)
16 Solid
Multi-Conductor
Irrigation Control Cable
PE Jacket with PVC Inner
Insulation with Rip Cord, 600 V Rating
ating
Std. Pkg.
Colors
13
4 x 500, 1 x 2500
1-12
Part #
Desc.
Wt./1000’
Std. Pkg.
17
4 x 500, 2 x 1000, 1 x 2500
1-12
18/02(P)
18 Solid / 2 Cond.
20
2 x 250, 2 x 500, 1 x 1000, 1 x 2500
18/03(P)
18 Solid / 3 Cond.
27
2 x 250, 2 x 500, 1 x 1000, 1 x 2500
18/04(P)
18 Solid / 4 Cond.
34
2 x 250, 2 x 500, 1 x 1000, 1 x 2500
18/05(P)
18 Solid / 5 Cond.
43
2 x 250, 2 x 500, 1 x 1000, 1 x 2500
18/06(P)
18 Solid / 6 Cond.
49
2 x 250, 2 x 500, 1 x 1000, 1 x 2500
18/07(P)
18 Solid / 7 Cond.
57
2 x 250, 1 x 500, 1 x 1000, 1 x 2500
18/08(P)
18 Solid / 8 Cond.
64
2 x 250, 1 x 500, 1 x 1000, 1 x 2500
18/09(P)
18 Solid / 9 Cond.
71
2 x 250, 1 x 500, 1 x 1000, 1 x 2500
18/10(P) 18 Solid / 10 Cond.
79
2 x 250, 1 x 500, 1 x 1000, 1 x 2500
18/12(P) 18 Solid / 12 Cond.
93
2 x 250, 1 x 500, 1 x 1000, 1 x 2500
18/13(P) 18 Solid / 13 Cond.
100
1 x 250, 1 x 500, 1 x 1000, 1 x 2500
18/16(P) 18 Solid / 16 Cond.
123
1 x 250, 1 x 500, 1 x 1000
18/19(P) 18 Solid / 19 Cond.
144
1 x 250, 1 x 500, 1 x 1000
18/25(P) 18 Solid / 25 Cond.
185
1 x 250, 1 x 500, 1 x 1000
Put-Up Code(P): 1-500’, 2-1000’, 5-2500’
UF Irrigation Cable
PVC Insulation, 600 V Rating,
ating
ating,
Underground FFeeder Cable
Part #
Desc.
Wt./1000’
Std. Pkg.
Colors
14UF(C)(P)
14 Solid
28
2 x 500, 1 x 2500
1-12
12UF(C)(P)
12 Solid
37
2 x 500, 1 x 2500
1-12
10UF(C)(P)
10 Solid
51
2 x 500,1 x 1000, 1 x 2500
1-9, 11
08UF(C)(P)
8 Solid
76
1 x 500, 1 x 1000, 1 x 2500
1-8
06UF(C)(P)
6 Str
120
1 x 500, 1 x 1000, 1 x 2500
1-5
04UF(C)(P)
4 Str
175
1 x 500, 1x 1000, 1 x 2500
1, 2, 3, 5
02UF(C)(P)
2 Str
280
1 x 500, 1 x 1000, 1 x 2500
1, 2, 3, 5
Put-Up Code(P): 1-500’, 2-1000’
Put-Up Code(P): 0-250’, 1-500’, 2-1000’, 5-2500’
PE Sprinkler Systems Cable
P ly
Po
l ye
ye thyl
y ene Insulation,
yl
600 V Rating,
g, Direct Burial
g
Part #
Desc.
Wt./1000’
Std. Pkg.
Colors
14PE(C)(P)
14 Solid
20
2 x 500, 1 x 2500
1-12
12PE(C)(P)
12 Solid
27
2 x 500, 1 x 2500
1-9, 11
10PE(C)(P)
10 Solid
40
2 x 500, 1 x 2500
1-2, 5, 6
Put-Up Code(P): 1-500’ , 2-1000’, 5-2500’
Flat Jacketed—Type UF-B
w/Ground-Direct Burial
PVC Insulation with THHN/THWN
Inners, 600 V Rating
Low Voltage
Lighting Cable
PVC Insulation, Flexible, Stranded Low
Energy Lighting Cable, 30 V Rating
Part #
Desc.
Wt./1000’
Wt./1000’
Std. Pkg.
18LC1(P)
18 Str / 2 Cond.
27
4 x 250, 2 x 500
142CWGJK(P)/143CWGJK(P) 14 Solid 2/3 with ground
53/93
1 x 500, 1 x 1000
16LC1(P)
16 Str / 2 Cond.
33
2 x 250, 2 x 500, 1 x 1000
122CWGJK(P)/123CWGJK(P) 12 Solid 2/3 with ground
Part #
Desc.
Std. Pkg.
75/134
1 x 500, 1 x 1000
14LC1(P)
14 Str / 2 Cond.
47
2 x 250, 2 x 500, 1 x 1000
102CWGJK(P)/102CWGJK(P) 10 Solid 2/3 with ground 140/194
1 x 500, 1 x 1000
12LC1(P)
12 Str / 2 Cond.
69
2 x 250, 1 x 500, 1 x 1000
082CWGJK(P)/083CWGJK(P)
8 Str 2/3 with ground
213/330
1 x 500, 1 x 1000
10LC1(P)
10 Str / 2 Cond.
95
1 x 250, 1 x 500
062CWGJK(P)/063CWGJK(P)
6 Str 2/3 with ground
305/449
1 x 500, 1 x 1000
08LC1(P)
8 Str / 2 Cond.
155
1 x 250, 1 x 500
Put-Up Code(P): 0-250’, 1-250’, 1-500’, 2-1000’, 5-2500’
Put-Up Code(P): 0-250’, 1-500’, 2-1000’
Tray Cable,
Type TC-Direct Burial
Bare Copper Wire
Soft Drawn Bare Copper,
Suitable for Grounding Purposes
Awg Size
Stranding
Wt./1000’
Std. Pkg.
PVC Insulation with THHN/THWN
Inners, 600 V Rating
14
Solid
12.4
2 x 2000’, 4 x 500’, 2 x 1000’
Part #
12
Solid
19.8
2 x 1250’, 4 x 500’, 2 x 1000’
10
Solid
31.5
2 x 800’, 4 x 500’, 1 x 1000’
8
Solid
50
6
Solid
4
2
Desc.
Wt./1000’
Std. Pkg.
123CTC(P)
12 Str / 3 Cond.
141
1 x 500, 1 x 1000
103CTC(P)
10 Str / 3 Cond.
209
1 x 500, 1 x 1000
4 x 500’, 1 x 1000’
083CTC(P)
8 Str / 3 Cond. w/grd.
323
1 x 500, 1 x 1000
79.5
4 x 315’, 1 x 500’, 1 x 1000’
063CTC(P)
6 Str / 3 Cond. w/grd.
536
1 x 500, 1 x 1000
Solid
126.3
4 x 200’, 1 x 500’, 1 x 1000’
043CTC(P)
4 Str / 3 Cond. w/grd.
701
1 x 500, 1 x 1000
Solid
200.9
2 x 125’, 1 x 500’, 1 x 1000’
023CTC(P)
2 Str / 3 Cond. w/grd.
1020
1 x 500, 1 x 1000
8
7 Str
51
4 x 500’, 1 x 1000’
6
7 Str
81
4 x 315’, 1 x 500’, 1 x 1000’
4
7 Str
128.9
4 x 200’, 1 x 500’, 1 x 1000’
2
7 Str
204.9
2 x 125’, 1 x 500’, 1 x 1000’
Put-Up Code(P): 1-500’, 2-1000’
Hunter® Twisted Decoder
Cable Jacketed
®
Hunter Twisted
Decoder Cable
Soft Drawn Bare Copper,
PE, 600 V Rating
Soft Drawn Bare Copper,
PE, 600 V Rating
Awg Size
Stranding
Wt./1000’
Std. Pkg.
Awg Size
Stranding
Wt./1000’
Std. Pkg.
14
Solid
55.6
1 x 500, 1 x 1000, 1 x 2500
14
Solid
43.4
1 x 500, 1 x 1000, 1 x 2500
12
Solid
75
1 x 500, 1 x 1000, 1 x 2500
12
Solid
61.6
1 x 500, 1 x 1000, 1 x 2500
Put-Up Code(P): 1-500’, 2-1000’, 5-2500’
Put-Up Code(P): 1-500’, 2-1000’, 5-2500’
Parallel
Communication Cable
Toro® Decoder Cable
Awg Size
Soft Drawn Bare Copper,
PVC, 600 V Rating
Stranding
Soft Drawn Bare Copper,
PE, 600 V Rating
Wt./1000’
Std. Pkg.
Awg Size
Stranding
Wt./1000’
Std. Pkg.
14
Solid
76
1 x 500, 1 x 1000, 1 x 2500
14
Solid
80
1 x 500, 1 x 1000, 1 x 2500
12
Solid
103
1 x 500, 1 x 1000, 1 x 2500
Put-Up Code(P): 1-500’, 2-1000’, 5-2500’
Put-Up Code(P): 1-500’, 2-1000’, 5-2500’
Communication
Cables
Soft Drawn Bare Copper
Part No. Awg Size No. of Pairs Wt./1000’
Std. Pkg.
PE-39
19
6
167
1 x 500, 1 x 1000
PE-89
22
6
78
1 x 500, 1 x 1000
PE-54
19
3
84
1 x 500, 1 x 1000
DBS203P
20
3
59.7
1 x 500, 1 x 1000
1804S
18
2
65
1 x 500, 1 x 1000
Toro®
Communication
Cable
Soft Drawn Bare Copper,
PVC, 600 V Rating
Awg Size
Stranding
Wt./1000’
Std. Pkg.
16
7 Strand
54
1 x 500, 1 x 1000, 1 x 2500
Put-Up Code(P): 1-500’, 2-1000’, 5-2500’
Put-Up Code(P): 1-500’, 2-1000’
830 South West Street • Sikeston, Missouri 63801 • 800.876.3020 • 573.472.2990 • Fax800.333.5676
www.regencywire.com
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3, B-8 and B-787.
Gauge sizes 14 thru 8 are solid conductors. Sizes 6 thru 4/0 are stranded conductors.
The insulation is a high quality polyvinylchloride (PVC) for systems applications of up to 600 volts and conductor temperatures up to 60° C.
Application: Suitable for use as direct burial power and control wire for irrigation systems.
Conductor: Soft drawn bare copper (ASTM Specs. B-3, B-8 and B-787), Solid (14 awg thru 8 awg), Stranded (6 awg thru 4/0 awg).
Insulation: Polyvinylchloride (PVC) Temperature: 60° C Voltage: 600 volts
Conductor Size
14 awg thru 10 awg
8 awg thru 2 awg
Insulation Thickness
.060
.080
Material must be able to pass the following tests without showing signs of degradation:
Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being
subjected to –25° C for four (4) hours.
Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure.
Regency’s Type UF cables are intended for use in accordance with Article
339 and other applicable parts of the National Electrical Code in wiring
systems operating at a potential of 600 V or less.
RoHS
Compliant
Please visit www.regencywire.com for complete specifications.
PE Sprinkler Systems Wire
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes
14 thru 10 are solid conductors.
The insulation is a linear low density, high molecular weight polyethylene for systems applications of up to 600 volts.
Application: Suitable for use as direct burial power and control wire for irrigation systems.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg).
Insulation: Polyethylene (PE)
Temperature: 75° C
Voltage: 600 volts
Conductor Size
14 awg thru 10 awg
Insulation Thickness
.045
Material must be able to pass the following tests without showing signs of degradation:
Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being
subjected to –25° C for four (4) hours.
Electrical — AC test voltage, 60 seconds at 7500 volts.
Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square inch.
Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure.
Regency’s single conductor PE Sprinkler Systems Wire
is manufactured for the purpose of direct burial power
wire applications in accordance with the National
Electric Code.
RoHS
Compliant
CONTROL WIRE
UF-TWU Irrigation Wire
Multi Conductor
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The
18 awg conductors are solid copper.
The insulation is a color coded high quality polyvinylchloride (PVC) for systems applications of up to 600 volts
and conductor temperatures up to 60° C. The outer jacket is linear low density, high molecular weight,
sunlight resistant, polyethylene (PE) with a nylon cord.
Application: Suitable for use as direct burial control cable for wiring central control systems to field controls.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (18 awg).
Insulation: Color coded polyvinylchloride (PVC)
Outer Jacket: Black polyethylene (PE)
Temperature: 60° C
Voltage: 600 volts
Conductor Size and No.
18-2
18-3
18-4
18-5
18-6
18-7
18-8
18-9
18-10
18-12
18-13
18-16
18-19
18-25
Conductor Insulation
.015
.015
.015
.015
.015
.015
.015
.015
.015
.015
.015
.015
.015
.015
Outer Jacket
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
RoHS
Compliant
Regency Wire & Cable
Underground Low Energy Circuit Cable
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes
18 and 16 are solid conductors.
The insulation is a high quality polyvinylchloride (PVC) for systems applications of up to 30 volts and conductor temperatures
up to 60° C.
Application: Suitable for use as direct burial power and control wire for irrigation systems.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (18 awg and 16 awg).
Insulation: Polyvinylchloride (PVC)
Temperature: 60° C
Voltage: 30 volts
Conductor Size
18 awg thru 16 awg
Insulation Thickness
.045
Material must be able to pass the following tests without showing signs of degradation:
Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being
subjected to –25° C for four (4) hours.
Electrical — AC test voltage, 60 seconds at 5000 volts.
Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure.
Regency’s single conductor Low Energy Circuit Cable is
manufactured for the purpose of direct burial power wire
applications in accordance with the National Electric Code.
RoHS
Compliant
Conductor construction is soft drawn bare copper meeting ASTM Specifications B-3 & B-787. THWN is available as stranded in sizes 14 thru 4/0 and solid in
sizes 14 thru 10.
The insulation is a high quality polyvinylchloride (PVC) with a nylon jacket for systems applications of up to 600 volts and conductor temperatures up to 75° C.
Application: Suitable for use as power wire for irrigation systems, when buried in conduit.
Conductor: Soft drawn bare copper meeting applicable ASTM Specifications, Stranded (14 awg thru 4/0 awg), Solid (14 awg thru 10 awg).
Insulation: Polyvinylchloride (PVC)
Jacket: Nylon
Temperature: 90° C
Voltage: 600 volts
Conductor Size
14 awg thru 12 awg
10 awg
8 awg thru 6 awg
4 awg thru 2 awg
1 awg thru 4/0 awg
Insulation Thickness
15
20
30
40
50
Jacket Thickness
4
4
5
6
7
RoHS
Compliant
800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com
Flat Jacketed–Type UF-B
Regency’s Type UF cables
are intended for use in
accordance with Article
339 and other applicable
parts of the National
Electrical Code in wiring
systems operating at a
potential of 600 V or less.
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-787.
Gauge sizes 14 and 10 are solid copper conductors. Sizes 8 thru 6 are stranded conductors. All ground wires are solid.
The insulation is a color coded THHN / THWN type for wet, dry or corrosive applications of up to 600 volts and conductor
temperatures up to 75° C. The outer jacket is a sunlight resistant, high quality polyvinylchloride (PVC).
Application: Suitable for use as direct burial or indoor branch circuit wiring.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (14 awg thru 10 awg), Stranded (8 awg and 6 awg),
Solid ground.
Insulation: Polyvinylchloride (PVC) with a nylon sheath
Outer Jacket: Polyvinylchloride (PVC)
Temperature: 75° C
Voltage: 600 volts
Conductors
2 w/grd
3 w/grd
2 w/grd
3 w/grd
2 w/grd
3 w/grd
2 w/grd
3 w/grd
2 w/grd
3 w/grd
Gauge Size
14
14
12
12
10
10
8
8
6
6
Conductor Stranding
Solid
Solid
Solid
Solid
Solid
Solid
Stranded
Stranded
Stranded
Stranded
Ground Size
14
14
12
12
10
10
10
10
10
10
CONTROL WIRE / POWER WIRE
THHN/THWN-2
Tray Cable Type TC
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3
and B-787. Gauge sizes 12 thru 2 are stranded copper conductors.
The insulation is a color coded polyvinylchloride (PVC) rated for continuous use at 90° C dry or wet and up to 600
volts. Each insulated conductor is sheathed with a nylon jacket that meets the requirements for THHN or THWN wire.
May be used in wet or dry locations, sunlight resistant, and suitable for direct burial. The Tray Cable will have a
polyvinylchloride (PVC) outer jacket.
Application: Suitable for use as power and control tray cable in direct burial applications.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-787), Stranded (12 awg thru 2 awg).
Insulation: Polyvinylchloride (PVC) with a nylon jacket Outer Jacket: Polyvinylchloride (PVC)
Temperature: 90° C dry or wet Voltage: 600 volts
Gauge
Number of
Conductor
Conductor
Jacket
Color
Size
Conductors
Stranding
Colors
12
3
19
Black, Red, Blue
Black
10
3
19
Black, Red, Blue
Black
8
3 w/bare grd.
19
1-2-3
Black
6
3 w/bare grd.
19
1-2-3
Black
4
3 w/bare grd.
19
1-2-3
Black
2
3 w/bare grd.
19
1-2-3
Black
Call Regency Wire and Cable for availability of other sizes and number of conductor tray cables.
RoHS
Compliant
Regency Wire & Cable
Toro® Communication Cable — Shielded/Armored
Conductor construction is tin coated, soft drawn bare copper meeting the requirements of ASTM Specification B-33.
The two conductors shall be insulated with a high quality polyvinylchloride (PVC) covered with a clear nylon sheath for
systems applications up to 600 volts. One conductor will be insulated yellow and the other conductor insulated gray.
Shielded: A 2 mil aluminum backed polyester shielding with a 16 awg solid tinned copper drain wire in contact with
the aluminum side is applied. The shield has a 25% minimum overlap.
Armored: The conductors and shielding are armored by helically wrapping the core with a .005” x .500” type 304
stainless steel tape. The armor has a minimum 25% overlap.
A polyethylene (PE) jacket covers the assembly.
Application: Suitable for use as Toro’s® communication cable for control of Toro® golf course sprinkler systems.
Conductor: Tin coated, soft drawn bare copper (ASTM Spec. B-33). Two (2) conductors. Stranded (16 awg).
Insulation: Polyvinylchloride (PVC) with a nylon sheath
Outer Jacket: Polyethylene (PE)
Temperature: 90° C
Voltage: 600 volts
Gauge Size
16
Strand
7
Insulation
Thickness
.015
Regency’s Toro® Communication Cable is manufactured for direct burial application of
Toro’s® golf course sprinkler systems.
Outer Jacket
Thickness
.045
RoHS
Compliant
Conductor construction is tin coated, soft drawn bare copper meeting the
requirements of ASTM Specification B-33.
The two conductors shall be insulated with a high quality polyvinylchloride
(PVC) for systems applications up to 600 volts. One conductor will be insulated
black and the other conductor insulated red. Both conductors shall be of the
same size as specified and/or shown on the drawings and as required for the
proper operation of the Satellite and Decoder units connected to it.
The two conductors shall be laid parallel and pressure extruded with a solid
color, linear high density, sunlight resistant polyethylene (PE) outer jacket.
The jacket comes in a variety of colors to accommodate easy identification.
Comes with pull cord for easy stripping.
Application: Suitable for use as Rain Bird’s® communication wire for control
of Maxi control systems.
Conductor: Tin coated, soft drawn bare copper (ASTM Spec. B-33),
Two (2) conductors, Solid (14 awg and 12 awg).
Insulation: Polyvinylchloride (PVC)
Outer Jacket: Polyethylene (PE)
Temperature: 60° C
Voltage: 600 volts
Gauge Size
14
12
Conductor Insulation
.060
.060
Outer Jacket
.045
.045
Regency’s Decoder Cable is manufactured for
the purpose of direct burial applications in
accordance with the National Electric Code.
RoHS
Compliant
Please visit www.regencywire.com for complete specifications.
1804S Irrigation Control Cable
Conductor construction is soft drawn bare copper meeting the requirements
of ASTM Specifications B-3 and B-8.
The insulation is color coded polyvinylchloride (PVC). Each insulated conductor
is sheathed with a clear nylon jacket and is twisted and color coded to facilitate
pair identification. The cable is then wrapped with an aluminum polyester tape.
Application: Suitable for control circuits for operation and interconnection of
protective and signaling devices. U.L. listed and labeled for installation in duct,
conduit and wireways. May be used in wet or dry locations, sunlight resistant,
and suitable for direct burial.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8),
Four (4) conductors, Stranded.
Insulation: Polyethylene (PE)
Conductor Size
18 awg
Number of
Conductors
4
Temperature: 90° C dry, 75° C wet
Voltage: 600 volts
Resistance: 6.92 OHMS per M at 68° F
Capacitance: 44.8 Pico Farads Nominal
Lbs./M': 65
Color Coding: Per ICEA method 1;
Pairs – black and white. One
conductor in each pair is printed
alphanumerically for easy
identification.
Conductor
Stranding
7
Drain Wire: 20 awg tinned copper laid between aluminum shield and PVC
insulation
Insulation: Polyvinylchloride (PVC) with a nylon sheath. Nominal insulation
thickness .015". Nylon thickness .004"
Outer Jacket: Polyvinylchloride (PVC) Nom. jacket thickness .045"
Nominal O.D.: .335"
Shield: Aluminum/Polyester
Regency’s Irrigation Control Cable is
manufactured for the purpose of power
and control cable applications in accordance
with the National Electric Code.
POWER WIRE / COMMUNICATION CABLE
Parallel Communication Cable
DBS203P Communication Cable
Conductor construction is soft drawn tinned bare copper meeting the
requirements of ASTM Specification B-33.
The conductors are 20 awg stranded with a polypropylene insulation. Each of
the insulated pairs are twisted and color coded to facilitate pair identification
with an aluminum polyester tape shielding and a drain wire. The overall jacket
is constructed with polyethylene insulation.
The cable assembly is then longitudinally wrapped with an electrically
continuous thick polymer-coated smooth aluminum tape overlapped to give
100% coverage.
Application: Suitable for use in requirements in communication for weather
station or pump station control equipment. U.L. listed and labeled for direct
burial.
Conductor: Soft drawn tinned bare copper (ASTM Spec. B-3).
Conductor Size
20 awg
Number of Pairs
3
Voltage: 350 volts
Nominal O.D.: .334"
Cable Wt.: 59.77 lb. / 1000'
Color Coding: Pair 1 - Black, Red; Pair 2 - Black, White; Pair 3 - Black, Green
Print Legend: Regency Wire 3 Pair 20 awg Shielded DBS203P U.L.
Conductor Stranding
10 x 30
Insulation: Polypropylene, nominal insulation thickness .0150"
Shielding: .00235" aluminum polyester tape, helically wrapped, over each
pair giving 100% shielding
Drain Wires: 20 awg tinned copper drain wire, for each pair laid under the
shield in contact with aluminum side for each pair
Jacket: .040" black sunlight resistant polyethylene
Resistance: 10.9 OHMS Per M at 68° F
Capacitance: 25.7 Pico Farads Nominal
Regency’s DBS203P
Communication Cable
is a three (3) pair cable
manufactured for the
purpose of direct burial
systems communication
for weather and pump
station applications in
accordance with the
National Electric Code.
Regency Wire & Cable
PE-89 Communication Cable
Conductor construction is soft drawn bare copper meeting the requirements
of ASTM Specification B-3. The conductors are 22 awg
solid copper.
The conductors are insulated with polyethylene (PE) in distinctive colors to
facilitate pair identification and are twisted into pairs with varying lays to
minimize crosstalk.
The interstices between the pairs are filled with an 80° C filling compound and
covered with a low density, high molecular weight black polyethylene (PE).
The assembly is then wrapped with two metal shield tapes: A corrugated .008"
thick polymer coated aluminum tape and a corrugated .006" polymer coated
steel tape.
Application: Suitable for use as direct burial communication applications
where protection against water and moisture entry is a critical requirement.
PE-89 is recommended where rodent attack is possible.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (22 awg).
Insulation: Polyethylene (PE)
Outer Jacket: Polyethylene (PE)
Temperature: 60° C
Resistance: 17.235 OHMS Per M Feet at 68° F
Number of Pairs
6
Outside Diameter
.40 in.
Regency’s PE-89 Communication Cable is a six (6) pair
cable manufactured for the purpose of direct burial
systems communication applications in accordance with
the National Electric Code.
Cable Weight
78 / M'
Conductor construction is soft drawn bare copper meeting the requirements
of ASTM Specification B-3. The conductors are 19 awg solid copper.
The conductors are insulated with polyethylene (PE) in distinctive colors to
facilitate pair identification and are twisted into pairs with varying lays to
minimize crosstalk.
The interstices between the pairs are filled with Waterbloc compound and
covered with a non-hygroscopic core wrap. The inner and outer surfaces of the
core wrap are coated with Waterbloc compound.
The assembly is then longitudinally wrapped with a corrugated .008" (0.2 mm)
thick copolymer-coated aluminum tape. This tape reduces the possibility of
shield corrosion and lightning damage. The outer surface of the shield is
flooded with Enviroblock compound. The outer jacket is polyethylene (PE).
Application: Suitable for use as direct burial communication applications
where protection against water and moisture entry is a critical requirement.
PE-39 is recommended where rodent attack is possible.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (19 awg).
Insulation: Polyethylene (PE)
Outer Jacket: Polyethylene (PE)
Temperature: 60° C
Voltage: 8.523 OHMS Per M Feet at 68° F
Number of Pairs
6
Outside Diameter
.061
Cable Weight
137 / M'
Regency’s PE-39 jacketed cable is manufactured
for the purpose of direct burial power wire
applications in accordance with the National
Electric Code.
800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com
PE Pet Containment Wire — 30 mil
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge
sizes 14 thru 10 are solid conductors.
The insulation is a linear low density, high molecular weight polyethylene for systems applications of
up to 600 volts.
Application: Suitable for use as tracer wire or pet containment wire.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg).
Insulation: Polyethylene (PE)
Temperature: 75° C
Voltage: 30 volts
Conductor Size
14 awg thru 10 awg
Insulation Thickness
.030
Material must be able to pass the following tests without showing signs of degradation:
Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after
being subjected to –25° C for four (4) hours.
Electrical — AC test voltage, 60 seconds at 7500 volts.
Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square inch.
Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure.
RoHS
Compliant
COMMUNICATION CABLE / PET CONTAINMENT WIRE
PE-39 Communication Cable
Low Voltage Lighting Cable
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-174.
Sizes 18-2, 12-2, 10-2 and 8-2 have flexible stranding conductors.
The insulation is a high quality polyvinylchloride (PVC) for conductor temperatures up to 60° C.
Application: Suitable for use in direct burial landscaping and lighting applications. Sunlight resistant.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-174), Flexible Stranded (18 awg thru 8 awg).
Insulation: Polyvinylchloride (PVC)
Temperature: 60° C
Voltage: 30 volts
Insulation
Conductor Size
Stranding
Thickness
18
16
.045
16
26
.045
14
41
.045
12
65
.045
10
105
.045
8
165
.060
• Call regarding colors other than black.
RoHS
Compliant
Regency’s Low Voltage Lighting Cable
is manufactured for the purpose of
direct burial landscape and lighting
applications.
Regency Wire & Cable
Hunter® Decoder Cable Non-Jacketed
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge
sizes 14 thru 10 are solid conductors.
The insulation is a low density, high molecular weight polyethylene. The conductors are twisted for systems
applications of up to 600 volts. UV inhibitors added for color stability. Conductor colors are blue and red and shall be
twisted with a 4" lay.
Application: Suitable for use as power and control wire of irrigation systems.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (14 awg and 12 awg).
Insulation: Polyethylene (PE)
Temperature: 75° C
Voltage: 600 volts
Conductor Size
14 awg and 12 awg
Insulation Thickness
.060
RoHS
Compliant
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14
and 12 are solid conductors.
The conductors are twisted for systems applications of up to 600 volts. Conductor colors are blue and red and shall be
twisted with a 4” lay. The jacket comes in a variety of colors to accommodate easy identification. Comes with pull cord
for easy stripping.
Application: Suitable for use as power and control wire of irrigation systems.
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (14 awg and 12 awg).
Insulation: Polyethylene (PE)
Outer Jacket: High Density Polyethylene (HDPE)
Temperature: 75° C
Voltage: 600 volts
Conductor Size
14 awg and 12 awg
Insulation Thickness
.045
Jacket Thickness
.035
Regency’s Decoder Cable is manufactured for
the purpose of direct burial applications in
accordance with the National Electric Code.
RoHS
Compliant
Please visit www.regencywire.com for complete specifications.
Toro® GDC Decoder Cable
Conductor construction is soft drawn bare copper meeting the requirements
of ASTM Specification B-3. Toro® GDC Decoder Cable features solid copper
conductors.
The conductors are twisted with a 4” lay and rated for systems applications of
up to 600 volts. Individual conductor colors are black and white. Comes with
pull cord for easy stripping.
Application: Suitable for use in direct burial applications for communication
with and control of Toro® decoder systems.
Conductor: Solid soft drawn bare copper (ASTM Spec. B-3 or B-8).
Insulation: Polyethylene (PE)
Outer Jacket: High Density Polyethylene (HDPE)
Temperature: 60° C
Voltage: 600 volts
Conductor
Size
14 awg
Insulation
Thickness
.045
Regency’s Decoder Cable is
manufactured for the purpose
of direct burial applications in
accordance with the National
Electric Code.
Jacket
Thickness
.035
RoHS
Compliant
LIGHTING CABLE / DECODER CABLE
Hunter® Decoder Cable Jacketed
Decoder / Solenoid Cable
Conductor construction is soft drawn bare copper meeting the requirements
of ASTM Specifications B-3.
The insulation is a linear low density, high molecular weight polyethylene (PE)
for conductor temperatures up to 75° C. A raised polarity ridge is present on
one leg.
Application: Suitable for use with decoder systems in direct burial
applications.
Conductor: Solid, soft drawn bare copper (ASTM Specs. B-3).
Insulation: Polyethylene (PE)
Temperature: 75° C
Voltage: 600 volts
Conductor Size
14
Insulation Thickness
.045
RoHS
Compliant
Regency Wire & Cable
PE Tracer Wire — 45 mil
Conductor construction is soft drawn bare copper meeting the requirements of ASTM
Specification B-3. Gauge sizes 14 thru 10 are solid conductors.
The insulation is a linear low density, high molecular weight polyethylene for systems
applications of up to 600 volts.
Application: Suitable for use as tracer wire.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8),
Solid (14 awg thru 10 awg).
Insulation: Polyethylene (PE)
Temperature: 75° C
Voltage: 600 volts
Conductor Size
14 awg thru 10 awg
Insulation Thickness
.045
Material must be able to pass the following tests without showing signs of degradation:
Cold Bend — The insulation shall not show any cracks when sample is bent around a
3X mandrel after being subjected to –25° C for four (4) hours.
Electrical — AC test voltage, 60 seconds at 7500 volts.
Mechanical Water Absorption — Insulation shall not absorb more than 25 mg
mass of water per square inch.
Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc
or xenon-arc exposure.
RoHS
Compliant
Regency’s single conductor Tracer Wire is
manufactured for the purpose of direct burial
power wire applications in accordance with the
National Electric Code.
DECODER CABLE / TRACER WIRE / THERMOSTAT WIRE
PE Tracer Wire — 30 mil
Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3.
Gauge sizes 14 thru 10 are solid conductors.
The insulation is a linear low density, high molecular weight polyethylene for systems applications of up
to 600 volts.
Application: Suitable for use as tracer wire..
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg).
Insulation: Polyethylene (PE)
Temperature: 75° C
Voltage: 30 volts
Conductor Size
14 awg thru 10 awg
Insulation Thickness
.030
Material must be able to pass the following tests without showing signs of degradation:
Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being
subjected to –25° C for four (4) hours.
Electrical — AC test voltage, 60 seconds at 7500 volts.
Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square
inch.
Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure.
RoHS
Compliant
800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com
Thermostat Wire
Conductor construction is soft drawn bare copper meeting the requirements
of ASTM Specification B-3. The 20 awg conductors are solid copper.
The insulation is a color coded high quality polyvinylchloride (PVC) for
conductor temperatures up to 75° C. The outer jacket is brown
polyvinylchloride (PVC).
Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (20 awg).
Insulation: Color coded polyvinylchloride (PVC)
Outer Jacket: Brown polyvinylchloride (PVC)
Temperature: 75° C
Voltage: 30 volts
Regency’s Thermostat Wire is
manufactured for the purpose
of thermostat applications in accordance with the National Electric Code.
Conductor Size
and Number
20-2
20-3
20-4
20-5
20-6
20-7
20-8
20-9
20-10
20-12
Conductor
Insulation
.008
.008
.008
.008
.008
.008
.008
.008
.008
.008
Outer
Jacket
.013
.013
.013
.013
.013
.013
.013
.013
.013
.013
Cadweld
Cadwelds
Regency Part #
Size
Flint Type
Control Unit Type
GR1161G
6 and 8 awg
CGR1161G
CGR1161G-PLUS
GR1161L
4 awg
CGR1161L
CGR1161L-PLUS
GR1161V
2 awg
CGR1161V
CGR1161V-PLUS
GT1161G
6 and 8 awg
CGT1161G
CGT1161G-PLUS
GT1161L
4 awg
CGT1161L
CGT1161L-PLUS
GT1161V
2 awg
CGT1161V
CGT1161V-PLUS
NT1161G
6 and 8 awg
CNT1161G
CNT1161G-PLUS
NT1161L
4 awg
CNT1161L
CNT1161L-PLUS
NT1161V
2 awg
CNT1161V
CNT1161V-PLUS
NX1161G
6 and 8 awg
CNX1161G
CNX1161G-PLUS
NX1161L
4 awg
CNX1161L
CNX1161L-PLUS
1 Way
2 Way
3 Way
4 Way
* If ordering flint type Cadweld order CT320 igniter.
* If ordering control unit type Cadweld order ERIPLUSCU igniter.
Regency Wire & Cable
Cadweld Igniters
Flint Gun
Regency Part # CT320
Control Unit
Regency Part # ERIPLUSCU
CADWELD / GROUNDING
Ground Rods
Ground Rods
5/8" Diameter x 8'
5/8" Diameter x 10'
UL
®
Ground Rods are suitable for use as grounding electrodes
in accordance with ANSI/NFPA 70, National Electrical
Code (NEC), and are also suitable for use in installation
of lightning protection equipment.
Please visit www.regencywire.com for complete specifications.
Ground Enhancing Material (GEM)
Estimated bags of GEM for backfilling around ground rods to a density of 1442 kg/m3 (90 lb/cu ft).
Diameter of Hole
Depth of Hole (feet)
1.8 m
(6')
2.1 m
(7')
2.4 m
(8')
2.7 m
(9')
5.2 m
(17')
5.8 m
(19')
6.1 m
(20')
7.5 cm (3")
2
2
2
2
4
4
4
10.0 cm (4")
2
3
3
3
6
7
7
12.5 cm (5")
3
4
4
5
9
10
10
15.0 cm (6")
5
5
6
7
13
14
15
17.5 cm (7")
6
7
8
9
17
19
20
20.0 cm (8")
8
9
11
12
22
25
26
22.5 cm (9")
10
12
13
15
28
31
32
25.0 cm (10")
12
14
16
18
34
38
40
Regency Part # GEM
Bare Copper Wire
Conductor construction is soft drawn bare copper meeting the
requirements of ASTM Specifications B-3 and B-8. Gauge sizes 14 thru 10 are
solid copper.r.r Sizes 8 thru 2 are available in either solid or 7 stranded. Gauge
size 1/0 thru 4/0 is available in either 7 or 19 stranded.
Application: Suitable for use in grounding purposes.
Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8),
Solid (14 awg thru 10 awg), Solid or 7 stranded (8 awg thru 2 awg),
7 or 19 stranded (1/0 awg thru 4/0 awg).
Size
14
12
10
8
6
4
2
Stranding
Solid
Solid
Solid
Solid / 7 STR
Solid / 7 STR
Solid / 7 STR
Solid / 7 STR
Regency’s Bare Copper Wire is manufactured for
grounding purposes in accordance with the National
Electric Code.
Gross Weight
Per MFT
12
20
32
51
81
129
205
Regency Wire & Cable
Ground Plate w/Insulated Ground Wire
Grroouunnddiinngg wi
G
wirree co
connssttrruuccttiioonn is .015 Polyethylene insulated soft drawn
copper meeting the requirements of ASTM Specification B-3. The plate is cut
to size from sheets of copper allow 110. The ground wire is connected to the
plate with a weld joint.
Application: Suitable for use in grounding applications as an alternative to
ground rods.
Construction Plate: Copper alloy 110
Conductor: Soft drawn insulated 6 awg solid copper (ASTM Spec. B-3)
Insulation: .015 Polyethylene (PE)
Plate
Dimensions
12" x 36" x .064
4" x 96" x .064
4" x 36" x .064
Ground
Wire Length
10'
25'
25'
Ground
Wire Size
6 awgg
6 awgg
6 awgg
Regency’s Grounding Plates are manufactured for the purpose of grounding
applications as an alternative to ground rods.
Underground Low
Energy Circuit Cable
Part #
Desc.
Wt/1000’
Std. Pkg.
Multi-Conductor
Irrigation Control Cable
Colors
Part #
Desc.
Wt./1000’
Std. Pkg.
UF Irrigation Cable
Part #
Desc.
Wt./1000’
Std. Pkg.
Colors
PE Sprinkler Systems Cable
Part #
Flat Jacketed—Type UF-B
w/Ground-Direct Burial
Desc.
Wt./1000’
Wt./1000’
Std. Pkg.
Colors
Low Voltage
Lighting Cable
Part #
Part #
Desc.
Desc.
Wt./1000’
Std. Pkg.
Std. Pkg.
800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com
830 South West Street, Sikeston, Missouri 63801
800.876.3020 • 573.472.2990 • Fax 800.333.5676
www.regencywire.com
Download