DOOR CONTROLLERS
type a dead man controller
Supplied as standard with all electric doors and grills, unless another type specified.
Comprises a box containing UP and DOWN contactors, terminals for supply, motor and limit switch. UP and DOWN buttons
on box drive door as long as button pressed – door will stop when you take finger off button (“dead Man control”) or when
door hits limit.
CODE
DESCRIPTION
DC-1A
Push to run, 1 phase type A controller with UP-DOWN contactors and push buttons, in IP65 enclosure.
DC-3A
Push to run, 3 phase type A controller, with UP-DOWN contactors and push buttons, in IP65 enclosure.
DC-VSD
Push to run, VSD type A controller with UP-Down push buttons and integral VSD for single phase
supply and 3 phase motor, soft start and stop and variable speed.
type m maintained controller
Similar to Type A, but when UP button pressed, door will go all the way up, until stopped by up limit. (“Maintained”)
DOWN button operates same as Type A, ie. “dead man”
CODE
DESCRIPTION
DC-1M
Single Phase. Maintained UP, Push to Run DOWN, 3 phase type M Controller, with contactors, overload
and UP-STOP-DOWN push buttons, in IP65 enclosure
DC-3M
Maintained, 3 phase type M controller, with contactors, overload and UP-STOP-DOWN push buttons, in
IP65 enclosure.
radio remote controllers
CODE
DESCRIPTION
RR3
Single Phase or 3 Phase. Complete stand alone, multi-mode Automatic Controller, single or 3 phase,
with UP-DOWN contactors and overload relay, UP-DOWN button, Modes are Toggle (Radio Remote),
Auto Close and Security Close. Beam and radio controls are extra
RR3 kit
Single Phase or 3 Phase. Complete stand alone, multi-mode Radio Remote Controller, single or 3
phase, with UP-DOWN contactors and overload relay, UP-DOWN button, and LRX-1E radio receiver
and 1 – LTX-1 Remote
Beam is extra
Modes are Toggle (Radio Remote), Auto Close and Security Close
CODE
DESCRIPTION
RRI1
Single Phase or 3 Phase. Radio Remote Interface for retrofit to local starter, motor set or tube motor.
RR1 kit
Single Phase or 3 Phase. Radio Remote Interface kit for retrofit to local starter, motor set or tube motor,
comprising RRI-1 unit, LRX-1E Receiver and 1 – LTX-1 Remote
Beam is extra.
Toggle mode only
auto logic controllers
Used on Car Parks, Hospitals, Fire Stations, Police, Courts, Prisons, Apartment and Office Blocks and any site where logic
control and interface with security or building management system is required.
CODE
DESCRIPTION
AL2-3P
Complete stand alone, full featured, multi-mode, automatic door controller for 3 phase motor. In IP65
enclosure with pad-lockable isolator, contactors, electronic overload relay, multi-mode logic board, with
mode switch and adjustable timers.
Modes are toggle (radio remote), auto close and security close.
The multi mode feature enables mode to be changed after installation. For example, if the tenant/owner
wants to change from toggle (UP-Down) mode to auto close, it only involves changing the dip switch on
PCB (printed circuit board).
Timers have screwdriver adjustment. No programming required.
Security close mode is new - door closes immediately after vehicle passes
beam - stops “tailing” and improves security.
Over run timer - to stop door if limits do not operate.
Auto/manual key switch enables easy setting of limits and facilitates service.
UP-DOWN limit switch and beam status contacts are provided.
With security and building management system inputs.
AL2-VSD
Complete stand alone, full featured, multi-mode, automatic door controller with integral VSD for single
phase supply and 3 phase motor, soft start and stop and variable speed.
In IP65 enclosure with pad-lockable isolator, contactors, multi-mode logic board, with mode switch and
adjustable timers.
Modes are toggle (radio remote), auto close and security close.
With security and building management system inputs.
radio remote controllers
This is the latest version of “Radio Remote Controller” but now features:
• Multi‐mode – Toggle, Auto Close and Security Close selected by switch on PCB.
• Screwdriver set timers ‐ No programming required!
• Over Run timer – Auto or Manual ‐ set to stop door if limits do not operate.
• Electronic overload relay – adjustable from 0.5 to 6.5 Amps.
• The multi Mode feature enables Mode to be changed after installation, for example, if the tenant/owner
wants to change from toggle (UP/DOWN) mode to Auto Close, it only involves changing the dip switch on PCB (printed
circuit board)
• Both Auto Close and Manual Run timers adjusted by screwdriver – no programming required!
• Security Close feature is new – door closes immediately after vehicle passes beam – stops “tailgating” and improves security.
• Remotes and Accessory connections are extra low voltage 24VAC.
RR‐3 is not a low cost alternative to AL‐2
It does not have inputs for security and building management systems, and does not have lockable isolator, manual mode or
variable speed control.
RR‐3 is a good low cost option for “stand alone” doors on factories, houses, and multiple storage facilities etc and control can
be by radio remote, prox, swipe card, ground loop and push button.
Fitting of beam is recommended.
ACCESSORIES
safety beam
CODE
DESCRIPTION
SB3
Safety Beam
The SB-3 is used as a safety device when fitted in conjunction with garage doors, rolling doors, sliding
gates, swinging gates and parking barriers.
It has a through beam photo cell with separate transmitter and a 10m range receiver, IP66
weatherproof. Power Supply 12-24v AC/DC, Relay contacts 5A 30V AC/DC.
remote receivers and transmitters
CODE
DESCRIPTION
LRX-1E
1 Channel
receiver with
antenna
Complete with an industrial type antenna and pre-fitted “F” connector for flexible mounting systems
these industrial/commercial receivers utilize a 1024 code. Code system that integrates perfectly with
our full line transmitters.
LTX-1
1 Button key
chain transmitter
Complete with LED to show the strength of your 12 volt alkaline battery, this portable transmitter
offers 1, 024 codes and operates at full distance range. It’s handsome neutral coloured, fine grained
finished case and moulded in hole to
accept your key ring or chain will add to the ease of using this key chain transmitter.
LTX-2
2 Button
key chain
transmitter
With all the capabilities of the 1 button model, the two button model offers you the capability of
operating either your gate and garage door, or 2 separate garage doors with one transmitter. This
model also offers 1024 codes on each of the channels to insure your security.
LTX-1V
1 Button Visor
Transmitter
One button, one channel 9 volt battery powered transmitter, with removable visor clip. 1024 codes.
LTX-2V
2 Button visor
transmitter
Two button, two channel 9 volt battery powered transmitter, with removable visor clip. 1024 codes on
each channel.
LTX-3V
3 Button visor
transmitter
Three button, three channel 9 volt battery powered transmitter, with removable visor clip. 1024 codes
on each channel.
LRX-C5
Coaxial cable
To be used in conjunction with LRX-1E. This is a 5 meter length of coaxial cable, with “F” type fittings
both ends. The mounting bracket is 130mm long with a 63mm outward extension. This allows for the
antenna to be mounted higher in the air or closer to the opening.
key switches
CODE
DESCRIPTION
KS-HDF
Heavy Duty, stainless steel plate and enclosure. 6 pin Lockwood 5 profile, with random key, and can be
fitted with most types of security cylinder, and master keyed.
Light Duty all have same key no, and cannot be changed.
Flush Plate UP-DOWN.
CODE
DESCRIPTION
KS-HD
Heavy Duty, stainless steel plate and enclosure. 6 pin Lockwood 5 profile, with random key, and can be
fitted with most types of security cylinder, and master keyed.
Light Duty all have same key no, and cannot be changed.
Enclosed UP DOWN
CODE
DESCRIPTION
KS-LD
Heavy Duty, stainless steel plate and enclosure. 6 pin Lockwood 5 profile, with random key, and can be
fitted with most types of security cylinder, and master keyed.
Light Duty all have same key no, and cannot be changed.
Light Duty UP DOWN enclosed.
UNIVERSAL LOOP DETECTOR
The only loop detector you’ll ever need.
CODE
DESCRIPTION
00-DSP-10
Loop Detector DSP-10 ”Universal” 10-30V AC/DC
features
Loop Size - Works on any in-ground inductive loop from 20
to
Indicators - Separate Power/Fail and Detect LEDs.
1000 uH.
small plastic case.
Fail Safe or Fail Secure Operation - Can be easily changed
to
Hold time - Normal or extended hold time is selectable.
either mode in the field.
Power Brownout Call Memory – Power interruptions of
short
duration are ignored. If power fails for approximately three
seconds or less the DSP-10 “remembers” a vehicle.
Intelligent Power Protection – A DSP-10-LV is protected
from damage if plugged into a higher voltage. No need
to change a fuse or reset a circuit breaker, simply plug the
detector into the proper voltage and it works.
Compact Size - Industry standard 11 pin connector in a
Loop failure - If the loop fails (opens or shorts) the
power indicator flashes. Output B can also indicate this
condition if desired (see above).
The option to “remember” an intermittent loop failure is
also provided.
Delay - Can be selected to ignore fast moving vehicles
over the loop.
Extension - Extends a call for slow moving vehicles.
front panel selectable switches
Sensitivity - Ten sensitivity settings.
Frequency - Automatically tunes within one of four
operating ranges.
Outputs - Two separate relay outputs with features that are
front panel programmable as follows:
Sensitivity Boost - Can be used in special applications to
insure complete detection of high-bed vehicles.
Output A - Main detection output. Can be modified by delay
and extension. Factory set to be fail safe. Fail mode operation
is easily changeable by internal jumpers.
Output B - Can be set to one of the following:
1) True presence (no extension or delay)
2) Pulse on vehicle entering loop
3) Pulse on vehicle exiting loop
4) Loop Fail output
OPERATION
The DSP-10 vehicle detector has been specifically designed to handle all parking, drive-through and access control
applications, working on virtually any size loop, the DSP-10 automatically tunes itself to the best operating frequency.
Environmental conditions are constantly compensated with the DSP-10’s HYPERTRACK software.
The DSP-10’s inherent noise filtering algorithms allow it to work reliably in any electrical situation, and it can be used as
either a safety loop or free exit loop detector. With the flexibility to be either “fail safe” or “fail secure,” it is the only parking
detector you will ever need.
The DSP-10 is available in two voltage ranges:
DSP-10-LV 10 to 30 Volts, AC or DC
DSP-10-230 230 Volts AC
With its compact size, front panel switch features, and built-in flexibility the DSP-10 is the most “user friendly” detector on
the market today.
dsp-10 instructions and specifications
Delay - With DIPSWITCH 1 turned off there is no delay.
With DIPSWITCH 1 turned on there is a 2 second delay
before output A occurs. This 2 second delay is “flashed” on
the CALL LED. If the vehicle leaves before the two seconds
has timed out, the output will not occur. Delay only affects
Output A.
Extension - DIPSWITCHES 2 and 3 are used to select
extension timing. See chart below for extension times.
Extension allows a vehicle to be “remembered” for a
period of time after the vehicle has left the loop. Selected
extension time is flashed on the call LED. Extension timing
only affects Output A.
DIP Switch 2 DIP Switch 3
0 seconds Off Off
2 seconds On Off
5 seconds Off On
10 seconds On On
Sensitivity Boost - DIPSWITCH 4 selects this feature. With
switch 4 turned on, sensitivity is automatically boosted
during a call to improve detection of high-bed vehicles
and truck/trailer combinations. Sensitivity boost is not
applicable to most situations.
Output B Function Select - DIPSWITCHES 5 and 6
determine the function of the second output relay, Output
B. See chart below to select a specific function. This output
can be used in any one of the following ways:
True presence - The relay is energized whenever a vehicle is
present. The relay is not affected by any delay or extension
timing.
Entry pulse - The relay is energized for 250 mS when
a vehicle enters the loop, or after the delay interval, if
programmed.
Exit pulse - The relay is energized for 250 mS when
a vehicle exits the loop or after the extension time, if
programmed.
Loop fail - If the inductive loop fails (opens or shorts), the
output B relay energizes.
DIP Switch 5 DIP Switch 6
True Presence Off Off
Entry Pulse On Off
Exit Pulse Off On
Loop Fail On On
Presence - DIPSWITCH 7 is normally left in the off position.
If extended presence is required, this switch is turned on.
This feature is only used in those rare cases when a vehicle
will be over the loop for a long time (loading dock, etc.).
Sensitivity - Experience has shown that almost all parking
and access control applications can be handled with
sensitivity set at NORMAL (level 5). The rotary sensitivity
switch is rarely moved from NORMAL. However, the DSP-10
has ten sensitivity settings varying from LOW (level 0) to
HIGH (level 9).
Loop Failure Memory - With DIPSWITCH 8 turned on, the
DSP-10 will indicate a prior intermittent loop failure.
Frequency - One of four operating frequencies can be
selected by using front panel DIPSWITCHES 9 and 10.
DIP Switch 9 DIP Switch 10
High Off Off
Medium High On Off
Medium Low Off On
Low On On
Fail Safe Operation (Factory Default) - In fail safe mode the
output A relay is energized and will de-energize for any one
of the following conditions: vehicle detection, loop failure,
or power failure. In this mode, continuity will occur between
connector pins 5 and 10 whenever a vehicle is detected.
Fail Secure Operation - In fail secure mode the output A relay
is de-energized and will energize for either vehicle detection
or loop failure. In this mode, continuity will occur between
connector pins 5 and 6 whenever a vehicle is detected.
NOTE - Changing any DIPSWITCH or ROTARY SWITCH
setting automatically resets the detector.
Indicators - The green POWER LED shows the following status:
Normal On
Loop open 1 flash/second
Loop shorted 2 flashes/second
Intermittent loop 3 flashes/second
The red DETECT LED shows the following status:
Delay Blinks slowly
Call On
Extension Blinks fast
No Detect Off
Output Relay Ratings - 3A, 150 VDC or 300 VAC.
Power - DSP-10-LV (10 to 30 Volts AC or DC), DSP-10-117 (117
Volts AC) and DSP-10-230 (230 VAC). Power consumption less
than 3 Watts (all models).
Enclosure - Impact resistant, high temperature plastic.
H - 2.375” (60mm) W - 1.75” (45mm) D - 3.61” (92mm)
Connector - Amphenol 11-pin connector:
1 (Black) - AC hot / DC +
2 (White) - AC neutral / DC COM
3 (Orange) - B relay (Closes for detect)
4 (Green) - Chassis ground
5 (Yellow) - A relay COM
6 (Blue) - A relay (Closes for detect)
7 (Gray) - Loop
8 (Brown) - Loop
9 (Red) - B relay Common
10 (Pink) or (White/Black) - A relay (Opens for detect)
11 (Violet) or (White/Red) - B relay (Opens for detect)
Operating Temperature - -35°F to 165°F (-37°C to 74°C).
integrated operators
Integrated Operators with Motor Controller and Limit Switches fitted with pre-wired pendant button (6M cord).
All operators are rated for High Cycle duty. Power Cord for “PLUG AND PLAY” installation. Except – N models
CODE
DESCRIPTION
LT-037-1P-DC-1A
0.37KW 0.5HP 240VAC 50Hz. Shaft Output: 80Nm, 28RPM, 85mm dia
Operation: Press to Run UP/DOWN
LT-037-1P-RR3
0.37KW 0.5HP 240VAC 50Hz. Shaft Output: 80Nm. 28RPM. 85mm dia
Operation: Complete Stand alone Multi mode automatic controller. Toggle, Auto Close or Security
Close
Integrated Operators with Motor Controller and Limit Switches fitted with pre-wired pendant button (6M cord). All operators
are rated for High Cycle duty. Power Cord for “PLUG AND PLAY”
LT-075-1P-DC-1A
0.75KW 1.0HP 240VAC 50Hz. Shaft Output: 160Nm, 28RPM, 95mm dia
Operation: Press to Run UP/DOWN
LT-075-1P-RR3
0.75KW 1.0HP 240VAC 50Hz. Shaft Output: 160Nm. 28RPM. 95mm dia
Operation: Complete Stand alone Multi mode automatic controller. Toggle, Auto Close or Security
Close
Integrated Operators with Motor Controller and Limit Switches fitted with pre-wired pendant button (6M cord). All operators
are rated for High Cycle duty. Requires three phase power supply only to be connected at installation
LT-037-3P-DC-3A
0.37KW 0.5HP 415VAC 50Hz. Shaft Output: 80Nm, 28RPM, 85mm dia
Operation: Press to Run UP/DOWN
LT-037-3P-RR3
0.37KW 0.5HP 415VAC 50Hz. Shaft Output: 80Nm. 28RPM. 85mm dia
Operation: Complete Stand alone Multi mode automatic controller. Toggle, Auto Close or Security
Close
Integrated operators with motor controller and limit switches fitted with pre-wired pendant button (6m cord). All operators are
rated for high cycle duty. Requires three phase power supply only to be connected at installation.
LT-075-3P-DC-3A
0.75KW 1.0HP 415VAC 50Hz. Shaft Output: 160Nm, 28RPM, 85mm dia
Operation: Press to Run UP/DOWN
LT-075-3P-RR3
0.75KW 1.0HP 415VAC 50Hz. Shaft Output: 160Nm. 28RPM. 85mm dia
Operation: Complete stand alone multi mode automatic controller. Toggle, auto close or security
close
Also available Integrated operators only, These operators are rated for high cycle duty. No motor controller fitted
- Naked for connection to separate wall mounted controller.
LT-037-1P-N
0.37KW 0.5HP 240VAC 50Hz. Shaft Output: 80Nm. 28RPM. 85mm dia
Operation: Naked.
LT-075-1P-N
0.75KW 1.0HP 240VAC 50Hz. Shaft Output: 160Nm. 28RPM. 85mm dia
Operation: Naked
electric motors
CODE
DESCRIPTION
ML7124
Single Phase 230V 50Hz
0.37kW 0.5hp D71 B34 frame foot and face mounting.
ML8024
Single Phase 230V 50Hz
0.75kW 1.0 hp D80 B34 frame foot and face mounting.
RMS7124
3 Phase 400V star or 230V delta 50Hz
0.37kW 0.5hp D71 B34 foot and face mounting.
RMS8024
3 Phase 400V star or 230V delta 50Hz
0.75kW 1.0hp D80 B34 foot and face mounting.
electric gear boxes
LEES TECH High Cycle Roller Shutter Operators feature a heavy duty industrial TEFC motor coupled to a cast aluminium
gearbox.
CODE
DESCRIPTION
01-LT037-3P 40:1
3 phase 400V Operator, 0.37kW 3 phase HCR Operator 40:1 ratio
01-LT037-3P 50:1
3 phase 400V Operator, 0.37kW 3 phase HCR Operator 50:1 ratio.
01-LT075-3P
3 phase 400V Operator, 0.75kW 3 phase HCR Operator
01-LT110-3P
3 phase 400V Operator, 1.1kW 3 phase HCR Operator
01-LT150-3P
3 phase 400V Operator, 1.5Kw 3 phase HCR Operator
01-LT220-3P
3 phase 400V Operator, 2.2kW 3 phase HCR Operator 50:1
01-LT037-1P 40:1
1 phase 230V Operator, 0.37kW 1 phase HCR Operator 40:1 ratio.
01-LT037-1P 50:1
1 phase 230V Operator, 0.37kW 1 phase HCR Operator 50:1 ratio.
01-LT075-1P
1 phase 230V Operator, 0.75kW 1 phase HCR Operator
rotary limit switch
CODE
DESCRIPTION
RLS-1
RLS-1 comprises a stainless steel worm shaft operating 2 micro switches rated for control circuit
up to 440VAC