Linear LED T8 Lamp

advertisement
Linear LED T8 Lamp
Direct Replacement LED T8
F32T8/8xx/LED/22W/IS Series
5 Year Warranty! Why Linear LED?
Energy Efficient
Reduced
Maintenance
Sustainable
•  Very efficient converting electric power to light output
•  Energy savings compared to T12 systems
•  Lower energy usage reduces energy costs
•  Longer rated life over incandescent, HID, and
fluorescent lighting systems
•  Longer rated life means lower maintenance costs of
lamp change outs
•  Better environmental choice
•  High quality lighting gives design flexibility
•  Can be used with lighting controls without
compromising lamp life
LEDT8 Features
•  Does not require electrical re-wiring to install
•  For use with Electronic Instant Start Ballasts
•  Automatically adjusts to the corresponding Ballast Factor
•  19w (Low Ballast Factor)
•  22w (Standard Ballast Factor)
•  26w (High Ballast Factor)
•  Environmentally friendly – no mercury, no UV or infrared light
•  Low lumen depreciation – maintains brightness over its 50,000 hour
rated life
•  Minimum heat emission, reducing load on building cooling systems
•  No flickers
•  ETL tested to comply with OSHA safety standards
•  DesignLights Consortium® Listed Product (4100K & 5000K lamps).
Visit designlights.org to view the Qualified Products List
....Another important consideration when replacing linear
fluorescent lamps with LED products is electrical safety.
Nearly all LED replacements bypass the existing ballast.
HOWARD LEDT8 USES THE
EXISTING INSTANT START
BALLAST
Most have their drive electronics integrated in the tube
HOWARD LEDT8
DOES NOT
while some are provided with external drivers that replace the existing
fluorescent ballast.
HOWARD LEDT8
DOES NOT
Bypassing the existing ballast results in line voltage being delivered to
the sockets (“tombstones”) in the fluorescent fixture, creating a hazard if
a fluorescent lamp is later re-installed in that same fixture.
HOWARD LEDT8
DOES NOT
If a fixture is modified such that it can no longer accept its original lamp,
it must have a label affixed (provided by the LED replacement
manufacturer) clearly indicating this condition.
HOWARD LEDT8 DOES NOT,
NO LABEL IS NEEDED
SOURCE DEPARTMENT OF ENERGY:
http://apps1.eere.energy.gov/buildings/publications/pdfs/ssl/led-t8-fluorescent-replacement.pdf
4’ T8 Lamp Change out with
New LED T8 Lamp
Present Bulb Wattage
LED Bulb Wattage
29.5 watts (F32T8 Lamp)
Using Normal Power Factor
Instant Start Multi-volt Ballast
22 watts (using Standard Ballast Factor Ballast)
Wattage Saved
7.5 watts
LED Bulb Life
50,000 hours
Energy Saved
375,000 watts over lamp life
To convert to Kilowatt Hours Divide by 1000
Energy Saved
KwH Rate
Amount saved per lamp
375 KwH
$0.12
$45.00
$0.10
$37.50
$0.08
$30.00
Energy and Cost Savings
Compared to T8 System
System descriptions
(optional)
Existing System
New System
4 Lamp F32T8
Linear Fluorescent Fixture
4 Lamp LED System
Linear Fluorescent Fixture
Hours burned
per year
4368
Number of Fixtures
1
Number of Fixtures
1
Cost per kWh $
0.12
Watts per Fixture
(exiting system)
110
Watts per Fixture
(new system)
88
Energy used per yr.
(existing system)
$57.65
Energy used per yr.
(new system)
$46
Energy Cost Estimation
Energy savings per year
(each new system fixture)
20%
Energy Saved!
$11.65
Ideal for a wide range of applications
•  Manufacturing facilities
•  Schools
•  Food Processing
•  Office Buildings
•  Dusty applications
•  Other applications
•  Re-lamping to comply with DOE energy efficiency standards
•  Hallways, Stairwells and other areas needing more directional
light and 24/7 operation
LEDT8 Series Specifications
Ballast Factor (BF)*
Power Consumption (P)
Luminous Flux (F)
Luminous Efficacy**
Low (78%)
Standard (88%) High (110%)
19 watts
22 watts
1,900 lumens
2,200 lumens
26 watts
2,600 lumens
100 lm/W
Input Voltage
110-277v (Instant Start Electronic Ballast only)
Power Factor
0.90
Color Temperature
Color Rendering Index
Rated Life
80+ CRI
3500K, 4100K, or 5000K
50,000 hours
* The LED26T8 Lamp “self-adjusts” light output that matches the corresponding ballast factor of the supply (or
control) ballast. The new “system matched” light output will meet or exceed that of the one it is replacing.
**Efficiency measured using 4100K with clear lens.
Ordering Information
F32T8/835/LED/22W/IS
4ft. Linear T8 LED Lamp,
80+CRI, 3500K
799385-62008 F32T8/841/LED/22W/IS*
4ft. Linear T8 LED Lamp,
80+CRI, 4100K
799385-62009 F32T8/850/LED/22W/IS*
4ft. Linear T8 LED Lamp,
80+CRI, 5000K
799385-62007
*
Download