Siding Blocks Brochure

advertisement
123491_Lngfrd.3
6/10/08
4:34 PM
Page 1
U L / C S A L I ST E D
THE SIDING SOLUTION!
TM
PAI NTAB LE S I D I N G M O U NTI N G B OX E S ,
K ITS & B LO C KS F O R A LL S I D I N G
T YP E S AN D F L AT S U R FAC E S
Arlington
New and
Retro Siding
Box Kits
pages
6-9
One-Piece
Fixture Box
page
8
Retro Siding
Box Kits
pages
10-12
8081
Flangeless, w/ vertical box opening
For standard light fixtures/devices
• • • •
8081F
With flanges, vertical box opening
For standard light fixtures/devices
• • • •
8081DBL
Double height, flangeless, w/ vertical box opening
For large light fixtures
• • • •
8081FDBL
Double height, with flanges, vertical box opening
For large light fixtures
• • • •
8082F
With flanges, vertical box opening
For fixtures/devices
• •
8091F
With flanges, deep vertical box opening
For GFCIs, large devices, fixtures w/ ballast
• • • •
8091FDBL
Siding box kit w/ MEGA mounting plate
For extra large fixtures, coach lamps
• • • •
8141F
One-piece fixture box
For light fixtures and receptacles
• • • •
8131
Kit with built-in electrical box
For mounting standard fixtures on 1/4, 5/16" siding
•
8141
Kit with built-in electrical box
For mounting standard fixtures on 1/2" siding
•
8141DBL
Kit with built-in electrical box
For mounting standard fixtures on 1/2" double siding
•
8151
Kit with built-in electrical box
For mounting standard fixtures on 5/8" siding
•
8161
Kit with built-in electrical box
For mounting standard fixtures on flat siding
•
8171
Kit with built-in electrical box
For mounting standard fixtures on dutch lap siding
•
8100LP
Oversized mounting cover converts Arlington’s standard siding
boxes for larger surface mounting
For large fixtures
MEGA
Siding Plates
page
13
8100MLP
Super MEGA siding plate converts Arlington’s standard
siding boxes for larger surface mounting
For extra large fixtures or coach lamps
S
Dutch Lap
Siding Solutions from Arlington!
5/8"
Page 2
1/2"
7:05 AM
1/4", 5/16"
6/6/08
Flat
123491_Lngfrd.2
T
Y
L
I
S
H
•
U
L
L
I
S
T
E
D
For
ID
RIG
NEWsiding
electrical box with
Retro
Fixture
Boxes with
Threaded
Openings
weatherproof-in-use cover
lap siding (also for stucco or
textured surfaces). Non-metallic
cover and base. Accepts most
single-gang wiring devices and
a GFCI cover plate. Box and white
cover are textured/ paintable. UV-
■
standard GFCI face plate, (1) NM cable connector, block bushing with washer, and an
in-place disposable mud cover.
Installs in the wall, so less of it
shows outside
Also for stucco or textured surfaces in new construction...
Mounting
Bases for
Meters and
other Products
pages
16-17
Install option: Cover is
removable for easier device
installation
B
22 cu. in.
Install NM cable connector
and wire. Attach recessed
IN BOX to block. Holes in
flange allow stucco to bond
firmly.
Make a 3-1/4" x 5-1/2" hole
in block. Pull wiring through
plastic block bushing and opening in block. Block bushing
mounts to interior side of block.
A
Install wiring device per
manufacturer’s instructions,
and local and National
Electrical Codes.
Retro Outlet
Boxes with
Threaded
Openings
Mounts
to block
C
E
NM cable
Block
bushing
Note: Meets 2008 NEC Section 406-8;
for the protection of exterior outlets
which require the use of a weatherproof while-in-use cover for all outdoor 15 or 20 AMP receptacles.
DBVM1C
Washer
Cable
Completed installation with
weatherproof-in-use cover.
(Ready for assembly of furring strips and drywall)
IN BOX and plastic block bushing mounted in concrete block
CATALOG
NUMBER
UPC/DCI/NAED
MFG #01 8997
Orientation/
Cover color
UNIT
PKG
STD
PKG
DIM
A
DIM
B
DIM
C
DIM
D
DIM
E
14315
14316
77608
77610
Vertical/Clear
Vertical/White
Horizontal/Clear
Horizontal/White
1
1
1
1
4
4
4
4
9.058
9.058
7.012
7.012
7.012
7.012
9.058
9.058
5.160
5.160
5.160
5.160
1.805
1.805
1.805
1.805
3.222
3.222
3.222
3.222
Retro
Weatherproof
Electrical
Boxes
DBVM1C
DBVM1W
DBHM1C
DBHM1W
Arlington
24
20
T
Y
L
I
S
H
U
L
L
I
S
T
E
D
MM18
Plastic mounting base, 17-5/8" x 15-7/8"
For mounting meters on siding
• • • •
DBHR151C , DBHR151W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
MM23
Plastic mounting base, 23" x 17-5/8"
For mounting meters on siding
• • • •
DBHR171C , DBHR171W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
FS8131T
Outlet box with threaded opening at top and bottom
For use on 1/4" or 5/16" rigid siding
•
DBVR131C , DBVR131W
Clear/White • Vertical
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
T
A
B
L
E
•
E
•
• • • •
A
S
•
•
•
•
•
DBHM1C , DBHM1W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for NEW Rigid Siding, Stucco and Textured Surfaces
•
DBVR131 Vertical, DBHR131 Horizontal
IN BOX™ Siding Profile Adapter Plate for Existing 1/4" or 5/16" Siding
•
DBVR151 Vertical, DBHR151 Horizontal
IN BOX™ Siding Profile Adapter Plate for Existing 5/8" Vinyl Siding
•
DBVR171 Vertical, DBHR171 Horizontal
IN BOX™ Siding Profile Adapter Plate for Existing Dutch Lap Siding
IN BOX™
•
Replacement Covers
T
O
I
N
S
T
A
L
L
S
T
DBVC , DBVW
IN BOX™ Replacement Covers
Clear/White • Vertical
DBHC , DBHW
IN BOX™ Replacement Covers
Clear/White • Horizontal
DV1
Dryer Vent mounting block kit
For mounting dryer vents on siding
Y
•
DBVM1C , DBVM1W
Clear/White • Vertical
IN BOX™ Weatherproof-in-use, recessed electrical box
for NEW Rigid Siding, Stucco and Textured Surfaces
DBVR141 Vertical, DBHR141 Horizontal
IN BOX™ Siding Profile Adapter Plate for Existing 1/2" Vinyl Siding
•
Y
•
DBVR171C , DBVR171W
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
Clear/White • Vertical
•
Dryer Vent
mounting block kit
N
•
DBVR151C , DBVR151W
Clear/White • Vertical
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
•
Back Cover
I
•
DBVR141C , DBVR141W
Clear/White • Vertical
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
•
FS8171
Plastic, stepped weatherproof electrical box
Deep design for GFCIs – For use on dutch lap siding
A
Dutch Lap
DBHR141C , DBHR141W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
FS8161
Plastic, stepped weatherproof electrical box
Deep design for GFCIs – For use on flat surfaces or siding
P
5/8"
• • • •
L
I
S
H
•
U
L
•
•
•
• • • •
Back Cover
•
1/2"
MM10
Plastic mounting block, 7" x 10"
Mount disconnects, timers, cable TV boxes, and more on siding
Patents Pending.
S
1/4", 5/16"
•
FS8151
Plastic, stepped weatherproof electrical box
Deep design for GFCIs – For use on 5/8" siding
page
Flat
DBHR131C , DBHR131W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Vinyl Siding
FS8141
Plastic, stepped weatherproof electrical box
Deep design for GFCIs – For use on 1/2" siding
R
with
grounding
lug
•
FS8091F
Plastic, weatherproof electrical box
For single-gang devices, including GFCIs
NM cable
connector
•
• • • •
FS8171T
Outlet box with threaded opening at top and bottom
For use on dutch lap siding
Stucco
D
DBHR1C , DBHR1W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for Flat Surfaces and Siding
DBHS1C, DBHS1W
Clear/White • Horizontal
IN BOX™ Weatherproof-in-use, recessed electrical box
for NEW Vinyl Siding
•
FS8161T
Outlet box with threaded opening at top and bottom
For use on flat siding or surface
IN BOX™
•
• • • •
FS8151T
Outlet box with threaded opening at top and bottom
For use on 5/8" siding
18-19
21-25
DBVR1C, DBVR1W
Clear/White • Vertical
IN BOX™ Weatherproof-in-use, recessed electrical box
for Existing Flat Surfaces and Siding
DBVS1C , DBVS1W
Clear/White • Vertical
IN BOX™ Weatherproof-in-use, recessed electrical box
for NEW Vinyl Siding
FS8141T
Outlet box with threaded opening at top and bottom
For use on 1/2" siding
pages
pages
•
8171TR
Kit with built-in electrical box, round with (2) threaded openings
For mounting fixtures on dutch lap siding
Box with weatherproof-in-use cover, installed bug plugs, (1) standard duplex and (1)
One-piece assembly replaces
the installation of an electrical
box and bubble cover assembly
Weatherproof-in-use,
Low Profile
Recessed Electrical Box
•
8161TR
Kit with built-in electrical box, round with (2) threaded openings
For mounting fixtures on flat siding or surfaces
IN BOX for NEW rigid siding includes...
rated plastic for long outdoor life.
IN BOX™
8151TR
Kit with built-in electrical box, round with (2) threaded openings
For mounting fixtures on 5/8" lap siding
14-15
DBVM1C
•
8141TR
Kit with built-in electrical box, round with (2) threaded openings
For mounting fixtures on 1/2" lap siding
pages
DBHM1W
uses standard indoor wall plates or
■
8131TR
Kit with built-in electrical box, round with (2) threaded openings
For mounting fixtures on 1/4" or 5/16" siding
One-piece, recessed
for new cementitious or fiber rigid
■
Flat
IN BOX™ Weatherproof-in-use, Recessed Electrical Box for NEW Rigid Siding
Dutch Lap
Page 1
5/8"
1:55 PM
1/2"
6/10/08
1/4", 5/16"
123491_Lngfrd6pgr
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:05 AM
Page 7
Installation of 8081F, 8081FDBL, 8082F, and 8091F with Flange
Insert provided NM cable
connector through the
knockout of your choice and
push the wire through.
For
inst
alla
tion
sidi
ng i
s in
stal
led
An electrical box
and cover, all-in-one!
BEFO
RE
Before siding is installed,
using the ’flanged’ style,
screw the box to the wall
using the holes provided in
the flange.
Install siding around box
section and caulk as required.
Attach the cover
(8081F shown).
Connect the wires and install
the fixture.
For
inst
alla
tion
sidi
ng i
s in
stal
led
1
2
Place box
section in
desired
location
and pencil
outline
onto
siding.
3
Cut along
pencil line
with razor
knife and
remove
vinyl
siding.
4
or
Siding
Type
Unit
Pkg
Standard
Pkg
8081
80812
All Types
25
8081DBL
80813
All Types
25
8081F
80814
All Types
25
Dim
Style
25
6.5" x 6.5"
w/o Flange
25
10.5" x 6.5"
w/o Flange
25
6.5" x 6.5"
with Flange
8081FDBL
80815
All Types
25
25
10.5" x 6.5"
with Flange
8082F
32240
1/2" or Less
25
25
6.5" x 6.5"
with Flange
8091F
17856
All Types
25
25
6.5" x 6.5"
with Flange
8081FB
10941
All Types
25
25
—
Box Only
8081FC
10939
All Types
25
25
—
Cover Only
8091FB
10945
All Types
10
10
—
Box Only
8091FC
10946
All Types
10
10
—
Cover Only
8081FDBLC
10943
All Types
10
10
—
Cover Only
8091FDBLC
10947
All Types
10
10
—
Cover Only
I
N
T
A
B
L
Install a
duplex
receptacle!
Connect
wires and
install fixture.
UPC/DCI/NAED
MFG #01 8997
A
Mount
box
section to
substrate.
Caulk as
required.
5
Place siding
block over
box section
(8081
shown).
P
The rectangular
hole provides
access to the wire
connections.
Siding block cover
is placed over the
electrical box.
AFTE
R
Installation of 8081 and 8081DBL without Flange
Catalog
Number
8081F
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
7
123491_Lngfrd.2
6/6/08
7:05 AM
Page 8
One-Piece Fixture Box
tion
talla FTER
s
n
i
A
For
Arlington’s one-piece
E soirnstalled
R
O
i
F
g
E
n
fixture
box is the easiest
B sidi
Patented
8141F Installation
Before siding is up...
No Extra Cover
to Lose or Store!
way to install light fixtures and
receptacles on siding.
1 Remove knockout from 8141F.
Insert cable connector. Push
NM cable through connector.
Its one-piece construction offers
2 Attach mounting block to
easy installation, and there’s no
substrate with (2) screws.
3 Install fixture according to
cover to lose or store.
manufacturer’s instructions.
8141F provides smooth vertical
4 Caulk as required.
mounting of light fixtures on all
siding types — before or after the
After siding is up...
siding goes up.
1 Cut hole in siding.
2 Break flanges off the back of the
8141F. Remove knockout. Insert
cable connector in KO, then push
NM cable through connector.
3 Attach mounting block to
8141F Costs 20%
Less than 8081F!
substrate with (2) screws.
4 Install fixture according to
manufacturer’s instructions.
5 Caulk as required.
■
For light fixtures
■
One-Piece design
■
For use with All Siding Types
■
UL/CSA Listed
■
With flange, use for mounting
before the siding is installed...with
flange removed, can be used after
the siding installation!
■
Made of high impact, UV-rated
plastic for long outdoor life
■
Textured, paintable finish
■
NM cable connector included
8141F
8141F
Fixture Box
VS
One-piece construction
2-pieces...electrical
cover & box
For lighting fixtures
R
with
grounding
lug
UPC/DCI/NAED
MFG #01 8997
8141F
10761
S
T
Y
L
I
S
H
•
For lighting fixtures &
standard receptacles
Description
Unit
Pkg
Standard
Pkg
One-Piece
10
10
Fixture Box
4-1/8" diameter x 1/2" deep
For All Siding Types
Arlington
8
Catalog
Number
8081F
Electrical Box
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:05 AM
Page 9
Siding Box Kit with MEGA Mounting Plate!
8091FDBL Installation
Mount coach lamps
that are too big for
BEF For instal
latio
O
n
sidinRE o
g is r A
inst FTE
alled R
smaller mounting plates with
Oversized 7-1/8" x 13-1/2" Mounting Plate
gives rigid support to large coach lamps.
8091FDBL. It has the largest
mounting plate available and an
Extra Deep 24.5 cubic inch UL Listed box - for
fixtures with transformers under the base.
extra deep electrical box.
1 Insert provided NM cable connector
through the knockout of your choice and
push the wires through.
The box and cover are made of
2 Box section mounts to substrate.
Caulk as required.
painted to accommodate any
3 Place MEGA block plate over box section.
color scheme.
UV-rated plastic and can be
4 Install fixture.
Mount the Largest Coach
Lamps with 8091FDBL!
■
Sturdy mounting surface provides
a solid mount for large fixtures.
■
Provides a UL Listed installation.
■
For use with All Siding Types.
■
With flange, use for mounting
before the siding is installed...with
flange removed, can be used after
the siding installation!
■
Kit includes a NM cable connector.
■
Cover may be rotated 180° to
accommodate fixtures with
mounting holes above or below
center line.
8091FDBL
Notched on back for
removal of outside
flange for retrofit
work.
Use ‘Down’ or ‘Up’ to fit any mounting hole
configuration.
R
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Description
24168
MEGA Mounting
8091FDBL
A
Standard
Pkg
10
10
with
grounding
lug
Plate Assembly
7-1/8" x 13-1/2"
For All Siding Types
P
Unit
Pkg
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
9
123491_Lngfrd.2
6/6/08
7:05 AM
Page 10
Siding Mounting Kits
with Built-in Box
Patented
For Installing Light Fixtures Vertical on Sided Structures.
Arlington offers a complete
Siding Mounting Kit for
Determine your Siding Type, to Select the Proper KIt...1/4" & 5/16", 1/2", 5/8", or Dutch
Lap Siding!
smooth, vertical mounting of
lighting fixtures on all siding
types!
tion
talla
s
n
i
For
ER d
AFiTs installe
g
sidin
Made of UV-rated plastic for
long, outdoor life, the textured
surface is paintable to match
the mounting surface.
The built-in electrical box
design ensures a UL Listed
installation every time.
Each kit includes:
Mounting Block with Built-in Electrical Box,
NM Cable Connector and 4 Screws.
R
with
grounding
lug
Arlington
10
S
T
Y
L
I
S
H
•
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:05 AM
Page 11
8131, 8141, 8151, and 8171 Siding Installation
8141
1
Select location for light fixture and caulk
opening around cable.
2
Remove knockout from electrical box and
insert cable connector. Push cable
through connector and position
mounting block onto siding.
B
C
A
Dutch
Lap
Lap
Siding
3
Secure mounting block with provided
screws. Install fixture.
8141DBL
Easily converts to an
Oversized fixture see MEGA
Siding Plate on page 13!
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Siding
Type
Std
Pkg
Dim
A*
Dim
B*
Dim
C*
8131
08131
1/4" & 5/16" Lap
10
4" Diameter
x 1/2" Deep
6.625"
6.625"
8141
10751
1/2" Lap
10
4" Diameter
x 1/2" Deep
6.625"
6.625"
8141DBL
54524
1/2" Double
10
4" Diameter
x 1/2" Deep
6.625"
10.200"
8151
10753
5/8" Lap
10
4" Diameter
x 1/2" Deep
6.625"
6.625"
8161
08161
Flat Surfaces
10
4" Diameter
x 1/2" Deep
6.625"
6.625"
8171
10757
Dutch Lap
10
4" Diameter
x 1/2" Deep
6.625"
6.625"
B
C
A
1/2" Double
Lap Siding
8141DBL
*For Dimensions A, B, and C, see drawings above
P
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
11
123491_Lngfrd.2
6/6/08
7:05 AM
Page 12
Siding Mounting Kit
with Built-in Box for installing light fixtures on FLAT Surfaces!
8161 Flat Surface
Installation
1
Select location for light fixture
and caulk opening around cable.
Remove KO, insert cable
connector, push cable through
and position block on surface.
2
Secure mounting block with
provided screws and apply paint
to textured block to match wall
surface.
8161...Installs Light Fixtures Vertically on Any FLAT Surface!
8161
3
B
Flat
Secure mounting block with
provided screws. Install fixture.
8161
C
A
Catalog
Number
R
with
grounding
lug
UPC/DCI/NAED
MFG #01 8997
Siding
Type
Std
Pkg
Dim
A*
Dim
B*
Dim
C*
08161
Flat Surfaces
10
4" Diameter
x 1/2" Deep
6.625"
6.625"
8161
Arlington
12
S
T
Y
L
I
S
H
•
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/10/08
3:01 PM
Page 13
MEGA Siding Plates...the Largest Mounting Covers in the Industry!
For use with Arlington’s Siding
Blocks and Boxes...
8131 ■ 8141
■ 8161
■ 8171
* for 8100MLP only
8151
■ 8082F
■
For
inst
allat
sidinAFTE ion
g is
R
inst
alled
Support large
fixtures or coach
lamps the easy way by
■
■
converting the standard size cover
8091F*
to a MEGA or SUPER MEGA cover.
And most other manufacturers’ mounting blocks.
There’s no need to remove the
octagonal block you’ve already
installed. The MEGA mounting plate
MEGA Siding Plate installation
fits right over the existing block.
1 Remove existing light fixture and
mounting bracket.
8100LP
2 Determine the mounting location
for new fixture on mounting plate.
May be rotated 180°
to accommodate
fixtures with offcenter mounting.
3 Place the 8100LP MEGA Siding
Plate over the fixture mounting
screws.
4 Install the new, large light fixture.
8100MLP
May be rotated 180°
to accommodate
fixtures with offcenter mounting.
SUPER MEGA Siding Plate installation
1 Use with an existing mounting
block.
2 Disconnect electrical power. Align
slots and secure the 8100MLP to
the siding block.
3 Install extra large fixture per
manufacturer’s instructions.
4 If screw holes are offset, simply
rotate the 8100MLP 180°.
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Description
Unit
Pkg
Standard
Pkg
8100LP
10749
MEGA Siding Plate
7-1/8" x 13-1/2"
1
10
8100MLP
10752
SUPER MEGA Siding Plate
8-1/2" x 16"
1
10
P
A
I
N
T
A
B
L
E
•
E
A
S
■
Accommodates light fixtures with
mounting brackets up to 12"
■
Provides a smooth, secure
mounting surface for large fixtures
■
Instantly converts a previously
installed octagonal siding block to
a MEGA siding plate
■
Adjusts up to 1" for offset
mountings
■
Features alignment mounting slots
to guarantee the MEGA Siding Plate
will stay securely in position
■
Made of UV-rated, paintable plastic
Patented / Other patents pending.
Y
T
O
I
N
S
T
A
L
L
13
123491_Lngfrd.2
NEW
6/6/08
7:06 AM
Page 14
Fixture Boxes with Threaded Openings
8161TR for Flat Surfaces
Install a fixture now, anywhere
you want it – add another fixture
later. It’s easy with Arlington’s
non-metallic fixture boxes with
threaded openings.
Saves Time. Convenient!
This box installs in either the
horizontal or vertical orientation,
and gives you the option of
installing your fixture where you
need it. You can also install
Add another Fixture or Outlet, the EASY way!
additional security or flood lights
at a later time through the
threaded openings.
8161TR Installation
Convenient and versatile, 8161TR
is designed for flat surfaces. We
also have an adapter plate for
each siding type that allows this
box to be used on all siding types
(see pages 18-19 for outlet boxes
Patent
pending
with threaded openings).
■
Non-metallic
■
Includes two threaded openings
■
Installs fixtures on flat, exterior
surfaces
■
UV-rated
■
Textured, paintable finish
1
Pull wire. Attach box to flat surface.
2
Install fixture.
3
Use threaded opening(s) and PVC
conduit...
4
to install additional fixture(s).
8161TR
fixture box
for flat
surfaces
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Siding Type
Unit
Pkg
Standard
Pkg
8161TR
00878
Flat Surfaces
10
10
Includes NM cable connector, (4) screws, (2) 1/2" NPT plugs
Arlington
14
S
T
Y
L
I
S
H
•
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:06 AM
Page 15
8131TR, 8141TR, 8151TR, 8171TR for Siding
We designed an adapter plate
that converts the 8161TR box for
flat surfaces into a fixture box that
can be used on any siding type.
■
Non-metallic
■
Includes two threaded openings
■
Install fixtures on any siding type
■
UV-rated
■
Textured, paintable finish
Patent
pending
An adapter plate
converts the flat
style for use on
any siding type
8171TR
for Dutch Lap
8161TR
8171TR Installation
1
Pull wire. Attach box to siding surface.
Install fixture.
2
Use threaded opening(s) and PVC
conduit...to install additional fixture(s).
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Siding Type
Unit
Pkg
Standard
Pkg
8131TR
8141TR
8151TR
8171TR
00875
00876
00877
00879
Rigid 1/4" or 5/16"
1/2"
5/8"
Dutch Lap
10
10
10
10
10
10
10
10
Includes NM cable connector, (4) screws, (2) 1/2" NPT plugs
P
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
15
123491_Lngfrd.2
6/10/08
2:10 PM
Page 16
Mounting Bases for Meters and other Products
tion
talla
s
n
i
For
Arlington’s one-piece,
ORE led
BEgFis instal
n
non-metallic
Mounting
i
sid
MM18, MM23 meter mounting bases
Bases provide a secure, flat
Support even the largest
electric meters
mounting surface for even the
largest electric meters.
MM23
Redesigned for even easier use,
the squared-off corners allow the
MM18
bases to be butted together for
gang installations!
They install before or after the
siding goes up, work with any
siding type, and accommodate
almost all meter sizes! They’re
UV-rated for long outdoor life and
paintable to match any color
scheme.
■
Provides a flat mounting surface
■
UV-rated for long outdoor use
■
Textured, paintable surface
■
One-piece, non-metallic
■
Provides a 1" overhang to cover
cut ends of siding
■
Gangable to accommodate most
meters and other products
MM10 mounting block
Mounts a variety of products on siding — fast!
■
Disconnects
■
Keypads
■
Timers
■
Telephone Boxes
■
Cable TV Boxes
Our 7” x 10” one-piece Mounting Blocks
mount a variety of products simply and
securely on siding. The block’s overhang
hides cut ends of siding for a clean,
attractive installation.
See chart on next page to select
the product matching your specific
installation condition.
MM10
Arlington
16
S
T
Y
L
I
S
H
•
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:06 AM
Page 17
MM10, MM18, and MM23 Installation
1
1
Fasten to substrate through
‘notched flanges’.
2
Siding butts to Meter Base,
overlapping the ‘notched
flanges’.
3
Meter Base mounting surface
provides a 1" overhang to hide
cut ends of siding.
4
And you’re ready to mount the
meter.
5
Caulk as required.
4
2
3
Gangable Meter Base
combinations
Mounting options
MM10
14"
MM18
MM10
MM18
31-3/4"
10"
35-1/4"
MM23
MM18
MM18
MM10
MM18
20"
MM10
17-5/8"
15-7/8"
7"
Seal all vertical joint channels
with Arlington’s DSC1 Duct
Sealing Compound
MM23
MM23
MM23
46"
35-1/4"
38-7/8"
MM23
MM18
MM23
17-5/8"
23"
17-5/8"
MM18
MM18
Rotate all illustrated combinations 90° for additional surface mounting options.
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Description
Unit
Pkg
Standard
Pkg
MM10
42278
Meter Mounting Block
7" x 10"
10
10
MM18
42280
Meter Mounting Base
10
10
10
10
17-5/8" x 15-7/8"
42282
MM23
Meter Mounting Base
For All Siding Types
P
23" x 17-5/8"
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
17
123491_Lngfrd.2
NEW
6/6/08
7:06 AM
Page 18
Outlet Box with Threaded Openings
FS8161T for Flat Surface
Shown with Arlington’s 60VW IN and OUT™ Cover (sold separately)
Install a receptacle where you
need it; add another outlet box
later. It’s easy with Arlington’s
non-metallic threaded-opening
outlet boxes.
Saves Time. Convenient!
The FS8161T box gives you the
option of installing the receptacle
where you need it – in horizontal
or vertical orientation. The
threaded openings allow for the
installation of additional outlet
boxes at a later time.
Patent
pending
Convenient and versatile,
FS8161T is designed for flat
surfaces. We also have an adapter
plate for each siding type that
FS8161T
outlet box
for flat surfaces
converts the FS8161T box for use
on all siding types.
■
Non-metallic
■
Includes two threaded openings
■
Installs devices on flat, exterior
surfaces
■
UV-rated
■
Textured, paintable finish
Add another Outlet,
the EASY way!
FS8161T Installation
1
R
with
grounding
lug
Pull wire. Attach box to
flat surface.
2
Install receptacle.
3
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Siding Type
Unit
Pkg
Standard
Pkg
FS8161T
00873
Flat
10
10
Includes (2) 1/2" NPT plugs
Arlington
18
S
T
Y
L
Use threaded opening(s)
and PVC conduit to install
additional outlet boxes.
I
S
H
•
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:06 AM
Page 19
FS8131T, FS8141T, FS8151T, FS8171T Outlet Boxes with Threaded Openings for Siding
We offer an adapter plate that
converts the FS8161T box for flat
surfaces into an outlet box that
can be used on any siding type.
■
Non-metallic
■
Includes two threaded openings
■
Install devices on any siding type
■
Horizontal or vertical installation
■
UV-rated
■
Textured, paintable finish
Patent
pending
FS8171T
outlet box with
adaptor for dutch
lap siding
FS8171T Installation
The adapter
plate converts
the flat box for
use on any
siding type
1
Pull wire. Attach the
appropriate adapter to
the FS8161T box and
install on siding.
2
Install receptacle.
3
FS8161T
Use the threaded
openings to add another
Outlet Box.
Use the threaded openings to add
another Outlet Box!
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Siding Type
Unit
Pkg
Standard
Pkg
FS8131T
FS8141T
FS8151T
FS8171T
00870
00871
00872
00874
Rigid 1/4" or 5/16"
1/2"
5/8"
Dutch Lap
10
10
10
10
10
10
10
10
FS8171T
for Dutch Lap
Includes (2) 1/2" NPT plugs
P
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
19
123491_Lngfrd.2
6/6/08
7:06 AM
Page 20
Weatherproof Outlet Box and FS Boxes
tion
talla FTER
s
n
i
A
For
For fast and easy
E soirnstalled
R
O
i
F
g
E
n
vertical
or horizontal installi
B sid
Outlet Box for
single-gang
devices,
including
GFCIs!
ation of devices in dry locations,
FS8091F is your best buy for areas
that don’t require a weatherproof
Add a weatherproof- in-use cover
to meet code in wet locations.
To save money on the total cost of
the box and cover –
and get a great
looking job too,
check out our
one-piece
IN BOX™ for siding
on page 22.
while in use cover.
Although FS8091F can be used
with a bubble cover for wet
locations as required by the NEC,
our IN BOX™ (DBVS1C or W)
FS8091F
on page 22 costs less than the
FS8091F Installation
combined cost of the outlet box
and a bubble
cover – and
looks a whole
lot better!
R
Before siding is up...
after siding is up...
1 Remove knockout and insert cable
connector. Push NM cable through
connector.
1 Cut hole in siding.
■
For all siding types
■
Installs before or after siding
■
Works with all single-gang,
devices including GFCIs
4 Install single-gang device (regular or GFCI).
4 Caulk as required.
5 Caulk as required.
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
17303
FS8091F
n
atio
stall
n
i
r
Fo
ER d
AFiTs installe
g
sidin
3 Attach outlet box to substrate with (2) screws.
3 Install device, FS8091F works with all
single-gang devices.
For All Siding Types
Description
Unit
Pkg
Standard
Pkg
Outlet Box for
10
10
installing devices on siding
Weatherproof FS Boxes
■
Non-metallic
■
For use with All Siding Types...1/2",
5/8", Dutch Lap, and Flat Surfaces.
mounting GFCIs, switches, and
■
For GFCI, switches, and outlets.
outlets on all
■
UV-rated for outdoor applications.
■
Provides a UL Listed installation.
■
Textured, paintable finish.
Arlington’s one-piece FS Box
ensures a solid, UL Listed
installation every time. Perfect for
siding types or flat
surfaces, the FS
Box is easy to
convenient to use.
FS8171 for Dutch Lap Siding
R
with
grounding
lug
Arlington
S
T
Now There’s a Plastic,
Weatherproof FS Box for Siding!
Install your choice
of either a GFCI,
Switch or Duplex
receptacle. The FS
Box’s unique
design accepts
them all!
install and
20
2 Break flanges off the back of the FS8091F.
Remove knockout. Insert cable connector in KO,
then push NM cable through connector.
2 Attach outlet box to substrate with
(2) screws.
FS8091F
with
grounding
lug
Y
L
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Description
Unit
Pkg
Standard
Pkg
FS8141
17340
1/2" Lap Siding
25
25
FS8151
17341
5/8" Lap Siding
25
25
FS8161
17342
Flat Surfaces
25
25
FS8171
17343
Dutch Lap Siding
25
25
I
S
H
•
U
L
L
I
S
T
E
D
123491_Lngfrd.2
6/6/08
7:06 AM
Page 21
IN BOX™ Weatherproof-in-use, Recessed Electrical Box for Flat Surfaces and Siding
ting
S One-piece,
exis
ACE recessed electrical
For
F
R
T SUsiding
box with weatherproofFLA and
in-use cover for flat surfaces in
existing construction. Non-metallic
cover and base. Accepts most
single-gang wiring devices and
DBHR1W
uses standard indoor wall plates
DBVR1C
or a GFCI cover plate. Box and
white cover are textured/
IN BOX for retrofit, flat surfaces and siding includes...
paintable. UV-rated plastic for long
Box with weatherproof-in-use cover, installed bug plugs, (1) standard duplex and
outdoor life.
(1) standard GFCI face plate, (1) set installation screws, (1) NM cable connector,
and (1) roll of caulk.
■
IN BOX’s one-piece assembly
replaces the installation of an
electrical box and bubble cover
assembly
■
Installs in the wall, so less of it
shows outside
■
Use the retrofit IN BOX on flat
siding, T-111, and other flat
surfaces
■
Install option: Cover is removable
for easier device installation
■
No gaskets required
Installation Instructions
1
Cut a 3-1/4" x 5-1/2"
hole in substrate. Pull
wiring.
2
Apply the supplied caulk
around back edges of
flange. Install NM cable
connector and wire,
then press onto surface.
Attach IN BOX with
stainless steel screws
provided.
3
Bug Plugs ship
installed in all
IN BOX styles
to seal unused
cord hole
openings.
22 cu. in.
A
4
Install wiring device per
manufacturer’s
instructions, local and
National Electrical Codes.
CATALOG
NUMBER
DBVR1C
DBVR1W
DBHR1C
DBHR1W
Accepts most single gang
wiring devices, and uses a
standard indoor wall plate.
DBVR1C shown.
B
DBVR1W shown.
IN BOX Saves Time.
Looks Great!
D
C
UPC/DCI/NAED
MFG #01 8997
Orientation/
Cover color
UNIT
PKG
STD
PKG
DIM
A
DIM
B
DIM
C
DIM
D
DIM
E
14313
14314
77604
77606
Vertical/Clear
Vertical/White
Horizontal/Clear
Horizontal/White
1
1
1
1
4
4
4
4
7.186
7.186
4.934
4.934
4.934
4.934
7.186
7.186
5.160
5.160
5.160
5.160
1.313
1.313
1.313
1.313
3.847
3.847
3.847
3.847
E
Note: Meets 2008 NEC Section 406-8;
for the protection of exterior outlets
which require the use of a weatherproof while-in-use cover for all outdoor
15 or 20 AMP receptacles.
R
Replacement covers and siding profiles to convert for use on existing siding available on page 25.
Patents Pending.
P
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
with
grounding
lug
O
I
N
S
T
A
L
L
21
123491_Lngfrd.2
6/6/08
7:06 AM
Page 22
IN BOX™ Weatherproof-in-use, Recessed Electrical Box for NEW Vinyl Siding
For
YL
VIN
W
g
NE sidin
Our one-piece
IN BOX for new siding
eliminates the need to
install an electrical box and a siding
block, and a bubble cover
assembly.
■
Outer flange covers
cut ends of siding
■
Fits all siding types
■
Install before new siding
goes up
■
Clear or white, vertical or
horizontal styles
DBHS1W
DBVS1C
Installation of IN BOXES or NEW Vinyl Siding
1
Cut hole. Pull wiring. Install
NM cable connector and
wire. Attach IN BOX to
substrate.
2
Siding profile
Install siding, inserting
the cut ends of the
siding under the outer
flange of the IN BOX.
3
IN BOX accepts most single gang wiring devices,
and uses a standard indoor wall plate.
Catalog
Number
adapter plate
allows use of
the retrofit
IN BOX on
any siding type.
UPC/DCI/NAED
MFG #01 8997
Orientation/
Cover Color
Unit/Std
Pkg
DBVS1C
DBVS1W
14317
14318
Vertical/Clear
Vertical/White
4
4
DBHS1C
DBHS1W
77600
77602
Horizontal/Clear
Horizontal/White
4
4
R
with
grounding
lug
Arlington
22
S
T
Y
L
I
S
H
•
U
L
Install wiring device
L
I
S
T
E
D
123491_Lngfrd6pgr
6/10/08
4:26 PM
Page 2
IN BOX™ Weatherproof-in-use, Recessed Electrical Box for EXISTING Vinyl Siding
Siding Box Kits
Arlington siding box kits give you
Siding
from
Arlington!
Solutions
DBVR141W
Listed and approved installation—
Box
Depth:
1.125
(15.5
cu. in.)
because this siding box is an
actual electrical junction box!
Each kit includes an electrical box,
8081F, 8081
cover, and NM cable connector
Arlington’s siding mounting boxes and kits give you what you need
and works on all siding types,
to install any kind of receptacle or light fixture on any kind of siding—
before or after the siding
L We fitted our
INY
V
retrofit IN BOX
G
STINsiding with a siding profile
I
X
E
For
.895
everything you need for a UL
8081 (flangeless)
adapter plate for use on
existing siding!
Note:
8081 is flangeless
For Standard Light Fixtures
and Devices
8081F (with flanges)
is installed. Before the siding is
before or after the siding goes up!
A
installed, use the ‘flanged’ 8081F,
.895
8081FDBL, 8082F, or 8091F. If the
Outdoor receptacles, boxes, meters, light fixtures, even extra large
Box
Depth:
1.125
(15.5
cu. in.)
siding is up or for retrofit work,
coach lamps, can now be mounted firmly and securely with
break the flanges off the flanged
Arlington’s ‘Siding Solutions’! Whatever your siding type or installation
styles above along the prescored
condition, we have what you need. From flanged to unflanged,
lines or use our ‘flangeless’ styles
standard electrical boxes or deeper ones for GFCIs, regular or extra
8081 or 8081DBL. For fixtures and
D
Installation of IN BOXES for EXISTING Vinyl Siding
C
A
Note:
8081DBL is
flangeless
A
B
E
B
8081FDBL, 8081DBL
receptacles that require GFCIs,
large mounting plates and individual boxes and covers, even flat
B
22 cu. in.
8081DBL (flangeless)
For Large Light Fixtures
8081FDBL (with flanges)
use the deeper 8091F.
surface designs, Arlington siding mounting products provide the
Easy to install, this series of
answer.
.375
siding mounting boxes features
premolded screw locations for
Installation is fast and easy. And with Arlington’s mounting boxes
Box
Depth:
1.125
(15.5
cu. in.)
devices and lighting fixtures. The
and kits you get smooth vertical mounting of all fixtures and
box enclosure can be installed in
receptacles. Plus, mounting boxes made of UV-rated plastic provide
two ways. The first method uses
long outdoor life. The textured surface is paintable to blend in with
the location holes for a typical
the color of your siding.
3-1/2" or 4" diameter box. The
8082F
1
Using the siding
profile adapter
plate as a
template, cut hole
in existing siding.
Pull wiring.
2
second uses the screw locations
for device mounting when
For Canadian shipments the grounding lug
rotated 90°.
is included as required by CSA.
Box
Depth:
1.625
(24.5
cu. in.)
rectangular hole for accessing the
shown with grounding lug.
the Arlington solution that’s right for you!
wire connections in the box
enclosure.
8091F
For GFCIs, Large Devices and Fixtures,
Fixtures with Ballast
8091F (with flanges)
Notched for removal of outside
flange for retrofit work
6.625
4.500
R
R
with
grounding
lug
Arlington
3A. Apply caulk to
reverse side of IN BOX
flange.
3B. Install NM cable
connector and wire,
then attach with long
screws (provided). Trim
excess caulk as needed.
Install wiring device.
.925
These mounting boxes provide a
Refer to the Product Selector Guide to find
3
2B. Attach adapter to
siding with short screws
(supplied) through the
holes noted above. Trim
excess caulk as needed.
For Fixtures and Devices on T-111 Siding
8082F (with flanges)
2A. Apply caulk around
edges of back of
adapter. Press onto
siding.
Front View
(Flanged)
Front View
(Without
Flange)
Back View
(Flanged)
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Orientation
Cover Color
Siding
Lap Size
Unit/Std
Pkg
77612
77614
77616
77618
77620
77622
77624
77626
14370
14375
14371
14376
14372
14377
14373
14378
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Clear
White
Clear
White
Clear
White
Clear
White
Clear
White
Clear
White
Clear
White
Clear
White
1/4, 5/16
1/4, 5/16
1/2
1/2
5/8
5/8
Dutch Lap
Dutch Lap
1/4, 5/16
1/4, 5/16
1/2
1/2
5/8
5/8
Dutch Lap
Dutch Lap
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
DBHR131C
DBHR131W
DBHR141C
DBHR141W
DBHR151C
DBHR151W
DBHR171C
DBHR171W
DBVR131C
DBVR131W
DBVR141C
DBVR141W
DBVR151C
DBVR151W
DBVR171C
DBVR171W
Arlington
5
6
S
T
Y
L
I
S
H
•
U
L
L
I
S
T
E
D
P
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
23
123491_Lngfrd.2
6/6/08
10:15 AM
Page 25
Installation Instructions for New Rigid Siding - Method 1
1
Install NM cable connector
and wire. Attach IN BOX to
stud.
2
Install moisture barrier
around IN BOX per
manufacturer’s instructions.
Cut rigid siding to fit
around IN BOX. Caulk
around box.
3
4
Install wiring device per
manufacturer’s instructions,
local, and National Electrical
Codes. Accepts most
devices and a standard
indoor wall plate. DBVM1W
shown.
4
Install wiring device per
manufacturer’s instructions,
local, and National Electrical
Codes. Accepts most
devices and a standard
indoor wall plate. DBVM1W
shown.
Installation Instructions for New Rigid Siding - Method 2
1
Make a 3-1/4" x 5-1/2" hole
in plywood. Pull wiring
through opening.
2
Install NM cable connector
and wire. Attach recessed
IN BOX to substrate, then
install moisture barrier
around box as shown above
in Method 1.
Cut rigid siding to fit
around IN BOX. Caulk
around box.
3
IN BOX™ Siding Profile Adapter Plates for Existing Siding Retrofit
ting
Exis
For
YL
g
VIsN
i
id n
Adapter plates convert the flat surface
retrofit DBVR1 and DBHR1 IN BOX series
(see page 21) for use on existing siding. Order
the siding profile adapter plate to fit
your particular siding type. UV-rated
plastic for long outdoor life. Paintable.
DBVR141
Catalog
Number
UPC/DCI/NAED
MFG #01 8997
Orientation
Siding
Type
Std
Pkg
DBVR131
14368
Vertical
1/4" or 5/16" Lap
4
DBVR141
14379
Vertical
1/2" Lap
4
DBVR151
14381
Vertical
5/8" Lap
4
DBVR171
14383
Vertical
Dutch Lap
4
DBHR131
77654
Horizontal 1/4" or 5/16" Lap
4
DBHR141
77656
Horizontal
1/2" Lap
4
DBHR151
77658
Horizontal
5/8" Lap
4
77660
Horizontal
Dutch Lap
4
DBHR171
Adapter plate for IN BOX includes...Siding profile adapter plate,
installation screws, and (1) roll of caulk.
P
A
I
N
T
A
B
L
E
•
E
A
S
Y
T
O
I
N
S
T
A
L
L
25
123491_Lngfrd.3
6/10/08
4:33 PM
Page 26
IN BOX™ Replacement Covers
Replacement covers sold
separately. Clear is not paintable
and white is
textured,
paintable.
DBHW
A
UV-rated
DBVC
plastic for
long outdoor
life.
ion
allat
inst
For
R
O E led
BEgFis instal
sidin
Catalog
Number
B
C
UPC/DCI/NAED
MFG #01 8997
Orientation
Siding
Type
Std
Pkg
Dim
A
Dim
B
Dim
C
DBVC
77640
Vertical/Clear
1
4
5.650
3.420
.370
DBVW
77642
Vertical/White
1
4
5.650
3.420
.370
DBHC
77650
Horizontal/Clear
1
4
3.420
5.650
.370
DBHW
77652
Horizontal/White
1
4
3.420
5.650
.370
Dryer Vent Mounting Block Kit
Arlington’s one-piece, non-metallic dryer vent mounting
■
Clean, attractive installation
– overhang covers cut ends
of siding
■
Smooth vertical mounting
of dryer vents on any siding
type
■
For new siding construction
■
Easy installation
■
Colors: Paintable White
■
Pre-mounted vent:
4" x 10-1/2" tube dimension
block kit provides the secure, attractive – and time-saving
way to install dryer vents on new siding.
Our 8 x 8 inch dryer vent mounting block kit comes complete
with a low profile, louver-type hood, a snap-together 4"
aluminum tube and a siding block with a built-in j-channel.
It fits all siding types: 1/2" and 5/8" step, and dutch lap.
UV-rated, and weather-resistant for long outdoor life, they’re
also paintable to match any color scheme.
DV1
Installation of Dryer Vent Mounting Block Kit
1
Cut hole in substrate
with a 4-1/2" hole saw.
Insert vent tube into
opening.
Catalog
Number
All products are Patented and/or
other Patents Pending.
DV1
2
Use screws to mount
dryer vent to substrate
through flanges.
3
UPC/DCI/NAED
MFG #01 8997
Description
Siding
Type
Unit
Pkg
Standard
Pkg
43607
Dryer Vent Mounting Block
8" x 8" vented plastic block
Mounts before siding
All
1
10
Arlington
1 Stauffer Industrial Park
Scranton, PA 18517
800/233.4717
Fax 570/562.0646
www.aifittings.com
©1999-2007 Arlington Industries, Inc.
26
0608/50M
S
T
Y
L
I
S
H
Install siding. Overhang
on vent flange hides cut
ends of siding. Caulk as
required. DV1 Dryer Vent
Mounting Block installed.
•
U
L
L
I
S
T
E
D
Download