DUAL-LITE
Serves the architectural, commercial and
industrial market place since 1940. Recognized
for innovative designs and quality life safety
products. Dual-Lite offers LED Emergency
lighting units, exit signs, battery packs and
central lighting inverters.
392
EV
Architectural LED Emergency Light
FEATURES
•
•
•
•
•
•
Architectural LED based emergency light for wall or ceiling commercial application
High impact, flame rated and UV stable white thermoplastic housing
Fully adjustable high output LED lamp-heads
Environmentally Friendly Nickel Metal Hydride Battery
Includes top mount conduit entry
Temperature Range: 20°C to 30°C(68°F to 86°F), damp: 10°C to 40°C(50°F to 104°F)
UL924 Listed(optional damp location listed)
EMERGENCY LIGHTING
U.S. Patents Pending
ORDERING INFORMATION
EV
MODEL
RATING
Blank Standard Model
D Damp Location
CAPACITY
2 1 W LED heads
4 2W LED heads4 OR
SELF DIAGNOSTICS
Blank None
I Spectron®
Listing2
1W LED w/ remote cap.
Capacity to run 2 head remote
EV2 available with or with-out damp listing, all other models include damp
3
-24K option only available with damp plus Spectron®
4
Not capable of running remote heads
5
Can only be run from EV4 model
6
-0 No-head option only available with EV4D-02L, with or without Spectron®
NOTE: Remote Capacity Option will only power the EVR2 and EVO remotes
1
1
OPTIONS
B Black Finish
24K 220-240VAC60Hz with
Spectron®3
Self-diagnostic
02L 2 watt LED heads5
2
0 No-head option to run
external remotes only6
ELECTRONICS
POWER CONSUMPTION
HZ.
AMPS.
WATTS
120
240
277
120
240
277
60
60
60
60
60
60
0.015
0.009
0.008
0.022
0.015
0.014
1.10
1.43
1.45
2.00
2.51
2.75
0.61
0.62
0.62
0.73
0.65
0.63
EV2
EV2D
AC VOLTAGE
POWER
FACTOR
EV4D
EMERGENCY LIGHTING
•
•
•
•
•
120/277VAC input with Intelligent 2 wire connection
AC lockout and Low Voltage disconnect
Battery re-charge within 24 hours
Optional Self-Test/Self-Diagnostic circuitry
MATCHING INDOOR REMOTE FIXTURES
WHITE SINGLE
BLACK SINGLE
EVR2
EVR2B
• The EV Series meets proposed California Energy Commission(CEC) requirements for
limits on power consumption in maintenance mode with less than 0.5 watts.
EV-LED
ACCESSORIES
MODEL DESCRIPTION
VRS3 Vandal resistant shield
WGLZ Wire Guard
MULTI-UNIT SPACING
5"
S
8.5"
2.19"
PW
1 fc Average
1 fc Minimum
Using 1 Watt
Heads
Using 2 Watt
Heads
Using 1 Watt
Heads
Using 2 Watt
Heads
Path Width
(PW)
Spacing
(S)
Spacing
(S)
Path Width
(PW)
Spacing
(S)
Spacing
(S)
3’
27’
39’
3’
14’
18’
6’
20’
33’
6’
10’
14’
Meets Life Safety Code minimum illuminance of 0.1 fc and average illuminance of 1.0 fc. Assumes open space with no obstructions, mounting height
of 7.5', ceiling height of 9' and reflectances of 80/50/20. Photometry files available on the Dual-Lite web site (www.dual-lite.com).
393
EVHC
High Lumen LED Emergency Light
FEATURES
EMERGENCY LIGHTING
•
•
•
•
•
High lumen output for high mounting height application
Fully adjustable LED lamp-heads
Long-Life Lithium Iron Phosphate Battery
Temperature Range: 10˚C to 40˚C (50˚F to 104˚F)
Listed to UL924 standards
U.S. Patents Pending
ORDERING INFORMATION
EVHC
MODEL
CAPACITY
6 6 Watts
12 12 Watts
SELF DIAGNOSTICS
Blank No Self-Diagnostics
I Spectron® Self-Diagnostics 4
FINISH
Blank White
B Black
OPTIONS
06L 6 Watt LED Lamps1
BC Battery
Compartment
Only available on EVHC with 12 watt capacity
BC option only available in White Finish
BC option only available with EVHC6, EVHC6I, EVHC12 or EVHC12I, not available with EVHC12-06L or EVHC12I-06L
4
Not for use with 220-240VAC input
1
2
3
ELECTRONICS
INPUT POWER CONSUMPTION
EVHC6
EVHC6I
EVHC6I2
EVHC6I2I
•
120 through 277 VAC, 50/60Hz input with intelligent 2 wire connection
AC lockout and Low Voltage disconnect
Battery re-charge within 24 hours
Optional Self-Test/Self-Diagnostic circuitry
-BC option adds ease of access battery compartment with polarity sensitive connector
INPUT V.
AMPS.
MAX. WATTS
120
0.028
2.30
277
0.028
2.2
120
0.023
2.30
277
0.028
2.2
MATCHING INDOOR REMOTE FIXTURES
WHITE DOUBLE
120
0.04
3.7
277
0.04
4.0
120
0.035
3.7
277
0.04
4.0
•
•
•
•
EVHCR2
Maintenance Mode Power Consumption 120 VAC - 0.32W; 277VAC - 0.36W
The EVHC Series meets proposed California Energy Commission(CEC) requirements for limits
on power consumption in maintenance mode with less than 0.5 watts.
EVHC-LED
7.375"
11"
394
3.25"
-BC option
EVE
LED Emergency Exit Sign
FEATURES
•
•
•
•
•
•
EXIT SIGNS
•
Compact LED based EXIT sign for wall, ceiling or end mounting
Matching Family Appearance
Bright and even EXIT panel illumination
AC only or 90 minute panel illumination in the event of power outage
Environmentally friendly, long life-cycle Nickel Metal Hydride battery
UL924 Damp Location Listed
Long-Life LEDs, 100,000 hours
ORDERING INFORMATION
EVE
MODEL
1
2
3
4
5
6
7
8
FACES
U Universal Face
LETTER COLOR
R Red
G Green
For use with Spectron self-diagnostic models only
For use with AC models only
Operates with 24 volt AC or DC fire alarm panels
For emergency illumination of sign from remote 6-24 VDC power source
-DC option may not be specified with -2C or -FAP options
- AF,-FM and -FAP options may not be specified together
See page 2 for special wording options
Special worded sign ships as a universal single or double face
FINISH
W White
B Black 7
OPERATION
Blank Standard Model
E Emergency
SELF DIAGNOSTICS
Blank None
I Spectron®
Self-diagnostic 6
OPTIONS
2C
FAP
FM
AF
DC
24K
2 circuit operation 2, 5
Fire Alarm Panel 1,3,5,6
Flasher Module 1,6
Audible Flasher 1,6
Remote DC Operation 2,4,6
220-240VAC
50,60Hz with Spectron®
SW Special Wording7,8
MATCHING FAMILY FIXTURES
5 .25
MODEL DESCRIPTION
EV Unit 2 LED Indoor Emergency Light
EVC Exit Sign/ LED Emergency Light
ACCESSORIES
MODEL DESCRIPTION
WGLX
WGLXC
Wire Guard (Wall Mount)
9.63
Wire Guard (Ceiling Mount)
SPECIAL WORDED OPTION SELECTION:
MODEL DESCRIPTION
SW3
SW4
SW10
SW11
SW13
SW69
IN USE
X-RAY IN USE
AREA OF REFUGE
AREA OF REFUGE WITH WHEELCHAIR
AREA OF RESCUE ASSIST. WITH WHEELCHAIR
SALIDA
11.5
1.5
* All special worded selections ship as a universal
sign for single or double-face application.
395
EVC
Architectural LED Combination EXIT/Emergency Light
FEATURES
•
EXIT SIGNS
•
•
•
•
•
•
•
Compact, Architectural LED based combination EXIT/emergency light for wall,
ceiling or end mounting
High impact, flame rated and UV stable thermoplastic housing
Dual-ratcheting design for full range LED lamp-head positioning
Bright and even EXIT panel illumination
Environmentally friendly, long life-cycle Lithium Iron Phosphate battery
Includes top mount conduit entry
Temperature Range: 20°C to 30°C(68°F to 86°F), damp: 10°C to 40°C(50°F to 104°F)
UL924 Listed(optional damp location listed)
U.S. Patents Pending
ORDERING INFORMATION
EVC
MODEL
FACES
U Universal Face
LETTER COLOR
R Red
G Green
FINISH
W White
B Black 7
Can only be specified with Spectron® Self-Diagnostics and remote capacity
Damp Location Listed not available with EVCURW and EVCUGW base models, standard
with all other models
3
No-head option only available on the EVC with remote capacity
4
-24K option only available with Spectron® Self-Diagnostic and remote capacity
5
FAP, FM or AF options may not be specified together
6
Spectron® Self-Diagnostics only available with damp
7
Black finish only available with damp option
1
APPLICATION
Blank Standard Model
D4 2 LED Remote
Capacity
D Damp Listed 2
SELF DIAGNOSTICS
Blank None
I Spectron®
Self-diagnostic 6
2
POWER CONSUMPTION
AC VOLTAGE
HZ.
AMPS.
WATTS
POWER
FACTOR
120
277
60
60
0.021
0.017
1.65
2.42
0.65
0.52
No Lamp-heads 3
Fire Alarm Panel 1,5
Flasher Module 1,5
Audible Flasher 1,5
220-240VAC
50,60Hz with Spectron® 4
SINGLE UNIT COVERAGE
1 FC AVERAGE
PATH DEPTH
(D)
PATH WIDTH
(W)
16’
10’
MATCHING REMOTE FIXTURES
MODEL DESCRIPTION
EVR2
EVO
EVR2B
VRS3
OPTIONS
0
FAP
FM
AF
24K
1 FC MINIMUM
D
2 LED indoor remote
Single or Double head outdoor remote
2 LED Remote with Black Finish
Vandal Resistant Shield
PATH DEPTH
(D)
PATH WIDTH
(W)
6’
10’
W
ACCESSORIES
MODEL DESCRIPTION
VRS3 Vandal resistant shield
Meets Life Safety Code minimum illuminance of 0.1 fc and average
illuminance of 1.0 fc. Assumes open space with no obstructions,
mounting height of 7.5', ceiling height of 9' and reflectances of 80/50/20.
EVC
Photometry files available on the Dual-Lite web site (www.dual-lite.com).
ELECTRONICS
•
•
•
•
120/277VAC input
AC lockout and Low Voltage disconnect
Battery re-charge within 24 hours
Optional Self-Test/Self-Diagnostic circuitry
9"
12"
Overall height with Canopy is 9.8”
396
2.55"
EVO
EVE Series
EVO
Outdoor LED Remote
R E M OT E H E A D S
•
•
•
•
•
•
R E M OT E H E A D S A N D F I X T U R E S
FEATURES
•
Matching LED remote for the Evolution family
High performance LEDs
Architectural remote specifically for the Evolution family
Durable Die-Cast Construction
Fully gasketed, waterproof construction
Single or Double Lamp-heads
Corrosion resistant Black or White finish
ORDERING INFORMATION
EVO
MODEL
S Single
HEADS
FINISH
B Black
D Double
W White
CAUTION: The EVO remote can only accept input power from the EV4D, EV4DI emergency lightor EVC-D4 combo with remote capacity. The EVO will not
work with any other emergency units.
INPUT POWER REQUIREMENTS
•
4.8Vdc at 1 watt per head provided exclusively from an EV4D or EV4DI emergency light with
remote capacity
SPECIFIC LED INFORMATION
•
•
•
•
Lamp color: Cool white
Total lamp output: 88 lumens per head
System Efficacy: 80 Lumens per LED
Rated LED Lamplife: Greater than 100,000 hrs.
EVO
OUTDOOR LED REMOTE
4.8"
7.3"
4.2"
DIMENSIONAL NOTE
Dimensions reflect maximum fixture width and depth.
397
PG
Emergency LED Sconce
FEATURES
EMERGENCY LIGHTING
•
•
•
•
•
•
•
•
Emergency unit for indoor/outdoor architectural applications
Sturdy, ADA compliant, vandal-resistant, die-cast aluminum construction
Four long-life, 6350K, high-output LEDs configured in redundant pairs
Wide area illumination pattern with no heads to aim
Maintenance-free nickel-cadmium battery with fully automatic charger
Temperature range: 0°C to 50°C (32°F to 122°F), w/heater: -30°C to 50°C (-22°F to 122°F )
UL 924 Wet location Listed
U.S. Patent No. D627,916.
ORDERING INFORMATION
PG
MODEL
FINISH
W White
Z Dark Bronze
P Platinum
OPTIONS
HTR Battery Heater
Add suffix to model
Silver
B Black
ELECTRONICS
•
•
•
•
•
POWER CONSUMPTION
120/277 60 Hz VAC operation, test switch and LED AC-On indicator light
Spectron® self-test/self-diagnostic circuitry
Transformer isolation, surge, transient and low voltage disconnect protection
Standard electrical box and conduit entry provisions
Reverse polarity, short circuit and AC lockout protection
MODEL WITHOUT HEATER
MODELS WITH HEATER
120VAC
2.78 Watts
120VAC
15.2 Watts
277VAC
2.88 Watts
277 VAC
15.7 Watts
Power factor, average: .60 (lagging)
Power factor, average: .97 (lagging)
MULTIPLE UNIT SPACING
SINGLE UNIT COVERAGE
Mounting Height: 9'
Illuminated Path Depth: 6’
Outdoor Reflectance: 0/30/10
Indoor Reflectance: 80/50/20
Mounting Height: 9'
Outdoor Reflectance: 0/30/10
Indoor Reflectance: 80/50/20
D
W
INDOOR
OUTDOOR
1 FC Average (W x D)
33' X 10'
27' X 10'
1 FC Average
1 FC Minimum (W x D)
10' X 10'
9' X 10'
1 FC Minimum
11
7
11
398
7
INDOOR
OUTDOOR
44'
33'
16'
15'
PGF1
High Performance LED Sconce
FEATURES
EMERGENCY LIGHTING
•
•
•
•
•
•
•
•
High performance LED wall-pack
Sturdy, ADA compliant, vandal resistant, die-cast aluminum construction
7 long life 4300K high output LED’s; 50,000 hours
Wide area illumination with no heads to aim
Dark Sky Compliant with use of supplied full cut-off shield
Available with optional 120VAC photo-control
Temperature range of -30˚C to 50˚C(-22˚F to 22˚F)
Certified to UL1598 for use in wet locations
U.S. Patent No. 0627,916
EMERGENCY LIGHTING
•
ORDERING INFORMATION
PGF1
MODEL
FINISH
Z Dark Bronze
OPTIONS
PC1 120VAC Photo-control
P Platinum Silver
INPUT POWER REQUIREMENTS
•
17.7 watts at 120/277VAC
SPECIFIC LED INFORMATION
•
•
•
Lamp color: Cool white, 4300K
Total lamp output: 1067 lumens
LED Lamplife: 50,000 hrs.
7
11
7
11
399
PGN
High Performance LED Sconce
FEATURES
EMERGENCY LIGHTING
•
•
•
•
•
•
•
•
•
Normally-on sconce for indoor/outdoor architectural applications
Compatible with remote DC input for emergency operation on same circuit
Sturdy, ADA compliant, vandal-resistant, die-cast aluminum construction
Four long-life, 4000K, high-output LEDs configured in redundant pairs
Wide area illumination pattern with no heads to aim
Dark sky compliant with use of supplied full cutoff shield
Temperature range: -30°C to 50°C (-22°F to 122°F)
UL 924 Wet location Listed
U.S. Patent No. D627,916.
ORDERING
ORDERING INFORMATION
INFORMATION
PGN
MODEL
FINISH
W White
Z Dark Bronze
P Platinum
Silver
B Black
ELECTRONICS
POWER CONSUMPTION
AC
•
DC
120 VAC
17 Watts
6 VDC
12 Watts
277 VAC
17 Watts
12 VDC
12.5 Watts
Power factor, average: .80 (lagging)
•
•
•
120/277 60 Hz VAC operation
Compatible with switched circuits
Transformer isolation, surge, and transient protection
Short circuit protection
SINGLE UNIT COVERAGE
MULTIPLE UNIT SPACING
Mounting Height: 9'
Outdoor Reflectance: 0/30/10
Indoor Reflectance: 80/50/20
Mounting Height: 9'
Illuminated Path Depth: 6’
Outdoor Reflectance: 0/30/10
Indoor Reflectance: 80/50/20
D
W
1 FC Average (W x D)
1 FC Minimum (W x D)
INDOOR
OUTDOOR
35' X 10'
29' X 10'
11' X 10'
1 FC Average
10' X 10'
7
1 FC Minimum
11
7
11
400
INDOOR
OUTDOOR
49'
37'
19'
16'
PGR
High Performance LED Remote
EMERGENCY LIGHTING
•
•
•
•
•
R E M OT E H E A D S A N D F I X T U R E S
FEATURES
•
High performance LED remote designed for indoor/outdoor applications
Sturdy , ADA compliant, vandal resistant, die-cast aluminum construction
Four long-life, high-output 4000K LEDs configured in redundant pairs
Design optimized for wide area illumination pattern with no heads to aim
90-minute emergency operation from external 6-12V DC source
U.S. Patent No. D627,916
ORDERING INFORMATION
PGR
MODEL
FINISH
W White
B Black
Z Dark Bronze
P Platinum Silver
INPUT POWER REQUIREMENTS
•
12 watts at 6vDC, 13 watts at 12vDC
SPECIFIC LED INFORMATION
•
•
•
•
Lamp Color: Neutral White, 4000K
Color Rendering Index (CRI): 75
Total Lamp Output: 445 Lumens min. Initial
LED Lamplife: 48,000 hrs. at 70% of Initial
7
11
7
11
401
DYN
NEMA4X LED Emergency Light
FEATURES
EMERGENCY LIGHTING
•
•
•
•
•
•
•
•
•
U.S. Patents Pending
I ndustrial LED based emergency light for wall or ceiling mount application
High impact gray finish housing in ABS thermo-plastic, covers and shield in polycarbonate
Fully adjustable high output LED lamp-heads with locking feature
Food Processing option(FP) includes shield over lamp-heads
Environmentally Friendly, Long-Life Lithium Iron Phosphate Battery
Continuous Lumen Output over the full 90 minute discharge requirement
Includes conduit entry through top center and both sides
Temperature Range: Wet/NEMA4X 10°C to 50°C(50°F to 122°F),
Heater Option: -30°C to 50° (-22°F to 122°F)
Listed to UL924, Wet Location and NEMA4X/IP66 Certified
ORDERING INFORMATION
DYN
MODEL
SELF DIAGNOSTICS
Blank No Self-Diagnostics
I Spectron® Self-Diagnostics
CAPACITY
6 6 Watts2
12 12 Watts3
Only available on EVHC with 12 watt capacity
DYN6 only available in the following configurations-DYN6, DYN6I, DYN6-4X, DYN6I-4X, DYN6I-4X-HTR, DYN6I-4X-FP,
DYN6I-4X-HTR-FP
3
DYN12 only available in the following configurations-DYN12, DYN12I, DYN12-4X, DYN12-4X-FP, DYN12I-4X,
DYN12I-4X-HTR, DYN12I-4X-FP, DYN12I-4X-HTR-FP, DYN12-06L, DYN12I-06L, DYN12-4X-06L, DYN12-4X-FP-06L,
DYN12I-4X-06L, DYN12I-4X-HTR-06L, DYN12I-4X-FP-06L, DYN12I-4X-HTR-FP-06L
4
FP option must be ordered with 4X option. Example: DYN6I-4X-FP
5
HTR option only available with Spectron
1
APPLICATION
Blank Wet Location
4X NEMA4X/IP66
rated
FP Food Processing
Rated4
2
INPUT POWER CONSUMPTION
DYN6
DYN6
with heater
CURRENT
•
120
0.03
3.40
•
277
0.04
3.49
•
120
0.18
20.94
277
0.08
21.13
120
0.05
5.98
277
0.04
6.52
120
0.21
25.30
277
0.09
25.60
•
•
•
Temp5
1 20 through 277VAC input at 50/60Hz with Intelligent 2 wire input connection
AC lockout and Low Voltage disconnect
Battery re-charge within 24 hours
Optional Self-Test/Self-Diagnostic circuitry
Optional Heater Circuitry
Optional remote capacity to run matching remote heads
6.04
DIMENSIONS
9.78
DYN12
HTR Heater for Cold
ELECTRONICS
MAXIMUM
WATTAGE
INPUT
VOLTS
OPTIONS
Blank 3 Watt lamps
06L 6 Watt LED lamps1
9.78
4.25
1.24
DYN12
with heater
5.15
11.25
11.61
Maintenance Mode Power Consumption 120 VAC - 0.33W; 277VAC - 0.36W
4.34
MATCHING REMOTE FIXTURE
REMOTE HEADS
3.54
5.15
DYNRS-4X
NEMA4X Rated
Single Head Remote
DYNRD-4X
10.54Rated
NEMA4X
Double Head Remote
DYNRS-4X-FP
Food Processing rated Single Head Remote
DYNRD-4X-FP
3.72Head
Food Processing rated Double
Remote
9.78
9.78
10.54
9.78
9.78
4.94
4.94
3.72
11.25
11.25
11.61
11.61
4.34
4.34
6.3
6.11
5.15
5.15
402
9.75
11.04
10.54
10.54
9.7510.54
10.54
11.04
4.94
4.94
DYNR
NEMA4X LED Remote
•
•
•
•
•
R E M OT E H E A D S A N D F I X T U R E S
FEATURES
Matching LED remote for the DYN series
Available in wet/NEMA4X or food processing option
Food processing option adds a shield
Single or double lamp-head
Designed for -22°F to 122°F (-30°C to 50°C)
ORDERING INFORMATION
DYNR
4X
MODEL
HEADS
S
D
Single
Double
OPTIONS
APPLICATION
Blank
FP
4X
NEMA4X
Food Processing
Rated with Shield
6.04
9.78
9.78
4.25
1.24 with remote capacity. The DYN remote will not work
CAUTION: The DYN remote can only accept input from the DYN emergency light
correctly with input from any other unit.
5.15
INPUT POWER REQUIREMENTS
•11.25
12.8vdc
11.61
at 3 watts per head provided exclusively from a DYN12 or DYN12I with remote capacity
SPECIFIC LED INFORMATION
•
•
•
Lamp color: Cool white, 5000K
Total lamp output: 331 lumens per lamp
Rated LED Lamplife: Greater than 100,000 hrs.
4.34
3.54
5.15
OPTIONAL FOOD PROCESSING WITH SHIELD DIMENSIONS
DIMENSIONS
10.54
10.54
4.94
4.94
3.72
6.3
3.72
6.3
6.11
9.75
11.04
9.75
11.04
403
HLEBS
Hazardous Location Emergency Light
FEATURES
EMERGENCY LIGHTING
•
•
•
•
Hazardous location LED based emergency lighting system
Copper free(less than 0.4%) aluminum housing with a baked on
electro-statically applied epoxy
Long-life Nickel Cadmium batteries
Integral Push-To-Test switch and AC indicator
ORDERING INFORMATION
HLEBS
MODEL
23DH
P
CAPACITY
23DH 23 Watts with two
heads for 90 min
TEST OPTIONS
P Integral PTT
on Enclosure
T
TIME DELAY
T 15 Min Time Delay
(120 or 277VAC)
LAMP-HEAD OPTIONS
N
A
BG
BE
CG
CE
D
EG
EE
DIRECT MOUNT CONFIGURATION EXAMPLES
A- HK Heads
Attached
BE-EL Heads
and Exit Acc.
CG-HK and
EL Heads
404
No heads - For Remote Heads Ordered Separately
2 HLEBSHK1030 Heads Factory Attached
2 HLEBSEL1030 Heads with Guards and Fittings for Attachment
2 HLEBSEL1030 Heads with 1 Guard and 1 HEXA-100 EXIT and
Fittings for Attachment
1 HLEBSHK1030 Heads Attached and 1 HLEBSEL1030 Head with
Guard and Fittings for Attachment
1 HLEBSHK1030 Heads Attached and 1 HLEBSEL1030 Head with
HEXA-100 EXIT and Fittings for Attachment
1 HLEBSHK1030 Only (2nd Head Remote - Ordered Separately)
1 HLEBSEL1030 Only with Guard and Fittings for Attachment
(2nd Head Remote - Ordered Separately)
1 HLEBSEL1030 Only with HEXA100 EXIT and Fittings for Attachment
(2nd Head Remote - Ordered Separately)
HLEBS
Hazardous Location Emergency Light
FEATURES
•
•
•
The EL and HK heads are available for indirect remote mounting and are used in
conjunction with the HLEBS housing/charger assembly designed to run 2 heads max.
All remote heads are hazardous location listed
All heads are 30VDC input with 10W load
EL heads offer 1021 lumens and HK heads offer 905 lumens initial output
EMERGENCY LIGHTING
•
Pendant
INDIRECT MOUNT CONFIGURATION EXAMPLES (ORDERED SEPARATELY)
Pendant
Wall
Ceiling
EL Remote
Heads
10W 30VDC
Pendant 3⁄4”
Ceiling
3
⁄4”
Wall
3
⁄4”
With Guard
HLEBSEL1030A2G
HLEBSEL1030X2G
HLEBSEL1030B2G
Without
Guard
HLEBSEL1030A2
HLEBSEL1030X2
HLEBSEL1030B2
Classification: CID1CD; CIID1EFG
HK Remote Heads 10W 30VDC
EBSHK1030-RFSC
HK Head with Adjustable Factory Sealed
“C” fittings set
HLEBSHK1030-RFSC
HK Head with Adjustable Factory Sealed
“L” fittings set
HLEBSHK1030-RFSL
Classification: CID1D; CIID1EFG
EBSHK1030-RFSL
DIMENSIONS
LUMINAIRE ACCESSORIES
MODEL DESCRIPTION
HEXA-100 Exit Accessory
13.75 ”
13.75 ”
14.5 ”
14.5 ”
14.5 ”
7.38”
12.13”
16 ”
10.5 ”
10.5 ”
10.5 ”
75
EMG1 Globe Guard
EMG1R Red Globe Guard
14”
7.5 ”
Pendant
1”
11.5”
14.5 ”
7.5 ”
7”
7”
7.75”
Wall
Ceiling
7.38”
12.13”
7.38”
7.38”
3.75
14”
8”
3.75
3.75
6”
14”
14”
Standard Dome
7”
7”
1”
12.13”
Exit Sign
11.5”
12.13”
12.13”
ERSD15 Dome Reflector
ERA15 Angle Reflector
7.75”
1”
1”
Exit Accessory
8”
6”
12.13”
7”
7”
7”
7”
11.5”
11.5”
Angled
7.75”
7.75”
8”
8”
6”
6”
405
LE
Recessed Mounting Edge-Lit LED Exit Sign
FEATURES
•
•
EXIT SIGNS
•
•
•
•
•
•
•
ORDERING INFORMATION
LE
MOUNTING
C Ceiling mount
W Wall mount
E End mount
MODEL
FACES
S Single
D Double*
LETTER
COLOR
R Red
G Green
*Not for use with
wall mounted
models.
DIRECTIONAL
ARROWS
X
R
L
D
No arrows EXIT
Right arrow* EXIT>
Left arrow* <EXIT
Double arrows
<EXIT>
C L/R arrows**
<EXIT/EXIT>
FINISH
N Satin
W
C
B
S
Z
Aluminum
White
Chrome
Black
Satin brass
Dark Bronze
*Not for use with double
face models. Use “C” L/R
arrow designator
** Double face models
only. Provides reversible
right or left arrow
indicator
POWER CONSUMPTION
MODEL
Red AC Only
Green AC Only
Red Emergency
Green Emergency
ACCESSORIES
SINGLE
FACE
DOUBLE
FACE
2.2W
2.5W
3.3W
3.6W
3.7W
4.4W
4.7W
5.2W
Wattage figures include LED lamps, transformers and
electronics power requirements.
Power factor, average: .80 (lagging)
MODEL DESCRIPTION
For use with AC models only.
Rough-in kit may not be ordered separately on models
specified with -24K option.
c
Must be ordered in conjunction with -2C option on exit
sign.
To Order Rough-In Kit Separately
To order rough-in kit only for early installation,
add “-XK” option suffix to exit model number and
order “URK” or “URK2C” kit separately.
•
•
•
406
SW
2C
FAP
FM
AF
DC
24K
XK
W
M
8L
b
Transformer isolation, surge, transient, and
low voltage disconnect protection
90 minute emergency operation
Reverse polarity, short circuit and AC-lockout
protection
120/277VAC 60Hz operation, test switch and
LED AC-On indicator light
SELF-DIAGNOSTIC
Blank None
I Spectron
self-testing/
self-diagnostic
electronics*
OPTIONS
MODEL
a
•
OPTIONS
See “Options”
section
*For use with emergency
models only.
URK Universal rough-in kit
URK2C Universal 2-circuit rough-in kit a,b,c
ELECTRONICS
OPERATION
A AC only
E Emergency
DESCRIPTION
Special Wording 12
2-circuit operation 2,5
Fire alarm panel interface 3,5,6
Flasher module 1,6
Audible/Flasher module 1,6
Remote DC Operation 2,4,5
220-240VAC, 60 Hz. operation 9
Recessed mount exit sign less rough-in kit 7,9
White plaque background
Mirror plaque background 8
8 inch letter plaque (red letters only) 10,11
For use with emergency models only.
For use with AC models only.
3
Operates with 24-volt AC or DC fire alarm panels.
4
For emergency illumination of sign from remote 6-24 VDC power sources.
5
-DC option may not be specified with -2C or -FAP options.
6
-AF, -FM and -FAP options may not be specified together.
7
Allows ordering of rough-in kit separately for recessed mount (LE) models.
See “Accessories”.
8
For use with single face models only. Standard on double face models.
9
Rough-in kit may not be ordered separately on models specified with -24K
option.
10
LE exit models with 8" plaques registered under NYC-BEC Calendar Number
42135 for use in New York City.
11
Single face LE exit signs specified with the -8L option are supplied without
backgrounds. Double face models specified with the -8L option are
supplied with mirror backgrounds.
12
Enter Special Wording choice from page 963: example: SW41. Special
wording option not available with 8" letter plaque. Some special wording
signs not available with directional arrows.
1
2
EXIT SIGNS
•
Edgelit exit sign for recessed mounted architectural and commercial applications
Clear, injection molded, dual plaque acrylic with clear, white or mirror backgrounds
High strength, extruded aluminum housing in multiple finishes
Energy saving, long-life LED lamps exceeds brightness and uniformity requirements
Custom printed, silk screened chevron arrows; 6" letters with ¾" stroke
End/ceiling/wall mount and included die-cast aluminum canopy
Maintenance-free nickel-cadmium battery with fully automatic charger
Temperature range: 20°C to 30°C (68°F to 86°F)
UL 924 Wet Location Listed
Special Worded signs certified to UL48-Electric Signs
SEMPRA
SE
®
Die-cast Exit Sign
FEATURES
•
•
•
•
•
•
•
•
MODEL
SE
(Surface)
SEMR (Master/Remote)
SERS (Recessed)
FACES
S Single
D Double
LETTER COLOR
R Red
G Green
OPERATION
Blank AC only
E Emergency
Brushed Face
WN White with
Brushed Face
MODEL
•
DESCRIPTION
Special Wording
2-circuit operation (2)(5)
Fire alarm panel interface (1)(3)(5)(6)
Flasher module (1)(6)
Audible/Flasher module (1)(6)
Remote DC operation (2)(4)(5)
220-240VAC, 60 Hz. operation
Vandal/tamper resistant option(8)
Sign assembly less rough-in back box – SERS only
(7)
•
•
•
•
Transformer isolation, surge, transient, and
low voltage disconnect protection
Pre-stripped pigtail leads with push in wiring
connectors
120 minute emergency operation
120/277VAC 60Hz operation, test switch and
LED AC-On indicator light
Reverse polarity, short circuit and AC lockout
protection
Rough-In Back Box
9 1/8”
120VAC
277VAC
2.6W
2.1W
3.8W
3.5W
2.6W
2.1W
3.8W
3.5W
Wattage figures include LED lamps, transformers and
electronics power requirements. LED lamp assemblies
(red or green) consume less than 1 watt.
Power factor, average: .8 (lagging)
12 3/8” (31.4 cm)
10”
(25.5 cm)
SE
or
Master Sign
MODEL
Red AC Only
Green AC Only
Red Emergency
Green Emergency
MODEL DESCRIPTION
(23 cm)
1 5/8”
testing/selfdiagnostic
electronics
VRS-3 Vandal resistant shield
FCM-R Kit converts AC red letter models to
emergency operation
FCM-G Kit converts AC green letter models to
emergency operation
PMCW 12½" Pendant mounting kit (white)
PMCB 12½" Pendant mounting kit (black)
WGLX Wire guard (Wall mount)
WGLXC Wire guard (Ceiling mount)
WGLXE Wire guard (End mount)
RBB Rough in back box kit
SERS
or
Remote Sign
(4.14 cm)
OPTIONS
See “Options”
section
ACCESSORIES
(1) For use with Spectron® self-diagnostic models only.
(2) For use with AC models only.
(3) Operates with 24-volt AC or DC fire alarm panels.
(4) For emergency illumination of sign from remote 6-24 VDC power sources.
(5) -DC option may not be specified with -2C or -FAP options.
(6) -AF, -FM and -FAP options may not be specified together.
(7) Enter Special Wording choice from page 959: example SW10. Not available
with SEMR or SERS models.
(8) Provides polycarbonate face shield and tamper-proof screws. Meets UL
listing requirements for floor proximity use.
11 3/4” (30 cm)
12 5/8” (32 cm)
SELF-DIAGNOSTIC
Blank None
I Spectron self-
POWER CONSUMPTION
ELECTRONICS
OPTIONS
SW
2C
FAP
FM
AF
DC
24K
VTR
LRBB
FINISH
W White
B Black
BN Black with
EXIT SIGNS
•
Die-cast aluminum exit sign for commercial or light industrial applications
Master/remote - SEMR (2 sign set) and recessed - SERS models available
Universal end/ceiling/wall mount and included die-cast aluminum canopy
Energy saving, long-life LED lamps exceed brightness and uniformity requirements
Completely concealed break out chevron arrows; 6" letters with ¾" stroke
Maintenance-free nickel-cadmium battery with fully automatic charger
Temperature range: 0°C to 40°C (32°F to 104°F)
UL 924 Listed; UL 924 Damp Location Listed (SE models only)
U.S. Patent No. 6,050,013 and 6,082,031
/8”
5
(1.6 cm)
9 5/8”
(24.4 cm)
407
LE, LES, SE
SPECIAL WORDING
Special Worded Sign
SE SEMPRA® SERIES SPECIAL WORDED SIGNS
EXIT SIGNS
EXIT SIGNS
Dual-Lite's cast-aluminum SE Series exit signs feature an option for custom or standard special-wording. The images
below represent a sample of standard special-worded signs available. Please review the SE Series specification sheet
for a complete list of standard special-worded signs or contact the factory to request your custom special-worded sign.
SW65 (Makhraj Arabic)
SW10
SW13
SW40
SW47
SW5
SW101
SW7
SW97
SW22
SW31
SW45
SW37
SW98
SW9
SW30
SW69
SW48
SW73
SW4
LE/LES SERIES SPECIAL WORDED SIGNS
LES Series architectural surface-mounted LED edge-lit exit signs feature an option for standard or custom specialwording. The images below represent standard special-worded signs available for the LES Series. The artwork and silkscreening for the standard signs shown below were previously developed therefore pricing for these special-worded
signs do not incur a setup charge.
If your special-worded requirements do not appear on this page, please contact the factory to request your custom
special-wording sign. Custom special wording signs incur a one time set-up charge for each development.
STANDARD SPECIAL WORDING SIGNS WITH DIRECTIONAL ARROWS
SW118
SW41 (Arabic/Exit)
SW13
SW10
SW69
SW11
STANDARD SPECIAL WORDING SIGNS WITHOUT DIRECTIONAL ARROWS
408
SW4
SW3
SW31
SW2
SEWL
Wet Location/NEMA 4X Die-cast Exit Sign
FEATURES
•
•
•
•
•
•
•
•
•
EXIT SIGNS
•
Exit sign for wall mounting in harsh applications or industrial environments
Heavy-gauge, corrosion resistant and gasketed die-cast aluminum housing
Spectron® self-test/self-diagnostic circuitry
Vandal resistant polycarbonate shield, with tamper resistant stainless steel screws
Universal end/ceiling/wall mount and included die-cast aluminum canopy
Energy saving, long-life LED lamps exceed brightness and uniformity requirements
Completely concealed break out chevron arrows; 6" letters with ¾" stroke
Maintenance-free, nickel-cadmium battery with fully automatic charger
Temperature range: -30°C to 50°C (-22°F to 122°F)
Certified to UL 924 Wet Location Standards; optional IP66; Nema 4X rating
ORDERING INFORMATION
SEWL
MODEL
FACES
S Single
D Double
LETTER COLOR
R Red
G Green
FINISH
B Black
W White
OPERATION
Blank AC Only
E Emergency
OPTIONS
HTR Internal heater 1
4X NEMA 4X rating 2
1
For use with emergency
models only.
2
Heater comes standard with
4X option on emergency
models.
POWER CONSUMPTION
ELECTRONICS
•
•
•
•
•
Transformer isolation, surge, transient, and low voltage disconnect protection
Pre-stripped pigtail leads with push in wiring connectors
90 minute emergency operation
Reverse polarity, short circuit and AC lockout protection
120/277VAC 60Hz operation, test switch and LED AC-On indicator light
MODEL
Red AC Only
Green AC Only
Red Emergency
Green Emergency
120VAC
277VAC
2.6W
2.1W
8.7W
8.3W
2.6W
2.1W
8.4W
8.1W
Wattage figures include LED lamps, transformers,
heaters with emergency models and electronics power
requirements. LED lamp assemblies (red or green)
consume less than 1 watt.
Power factor, average: .95 (lagging)
5¼" Square
Single Face 3" Deep
Double Face 3½" Deep
Single Face NEMA 4X 3¾" Deep
103⁄16"
97⁄16"
1411⁄16"
157⁄16"
409
UFO-LED
UFO-LED
LED Battery Pack
LED Battery Pack
FEATURES
FEATURES
Battery pack with 120/277 VAC 60Hz inverter output to power driver for an LED
•
luminaire
•
Battery pack with 120/277 VAC 60Hz inverter output
driver/LED at full lumen output for 90 minutes
• •
Can
bebeused
Can
usedwith
withswitched
switchedororunswitched
unswitchedluminaires
luminaires
• •
Installation
Installationmay
maybebewithin,
within,ororremote
remotefrom
fromthe
theluminaire;
luminaire indoor installation for indoor
or outdoor luminaires
Indoor installation for indoor or outdoor luminaires
120/277 VAC 60 Hz input operation, remote test switch with AC-On indicator light
120/277 VAC 60 Hz input operation
Temperature range: 0˚C to 50˚C (32˚F to 122˚F)
• Remote test switch with AC-On indicator light
UL 924 Damp Location Listed
• Temperature range: 0°C to 45°C (32°F to 113°F); 20VA/W only for
45°-50°C (113°-122°F)
• UL 924 Damp Location Listed
•
•
•
•
•
ORDERING INFORMATION
ORDERING INFORMATION
U LED
UFO-LED
MODEL
MODEL
UFO-LED
25
20
OUTPUT VA/W
CAPACITY 20
25 VA/W
ACCESSORIES
ACCESSORIES
SPECIFICATIONS
SPECIFICATIONS
MODEL DESCRIPTION
DESCRIPTION
MODEL
SPRTS Remote test
test switch
switch/charge
/chargeindicator
indicatormodule
module1 1,2
11
2
Fits single-gang
single-gang box
box
Fits
Comes standard; additional may be ordered
CATALOG
NUMBER
CATALOG
NUMBER
INPUT
WATTAGE
INPUT
WATTAGE
MAX.
LOAD
VA/W
MAX.
LOAD
VA/W
F PF)
(UNITY
LAMP
TYPETYPE
LAMP
UFO-LED25
UFO-LED25
9.59.5
25 25
LEDLED
UFO-LED
UFO-LED25
SPRTS (included remote test switch with charging indicator)
UFO-LED25
SPRTS (INCLUDED REMOTE TEST SWITCH WITH CHARGING INDICATOR)
0.2”
(5mm)
2.85"
2.8"
4.55”
(116mm)
16.6"
978
410
2.75”
(70mm)
BAT T E RY PAC K S
BAT BAT
T E RY
KS KS
T EPAC
RY PAC
• •
Sealed
Sealednickel-cadmium
nickel-cadmiumbattery;
battery powers
LPS
Central Lighting Micro Inverters
FEATURES
•
•
•
•
•
•
M I C R O I N V E RT E R
•
AC output provides full lumen output for emergency lighting loads in
commercial or industrial applications
Compatible with incandescent, LED, compact and linear fluorescent lamps
White painted steel enclosure
Offline operation for greater efficiency
Maintenance-free Lead-Calcium or Nickel-Cadmium batteries
Temperature range: 20°C to 30°C (68°F to 86°F)
UL 924 Listed
ORDERING INFORMATION
LPS
CAPACITY
20 20 VA/W 1
32 32 VA/W 2
35 35 VA/W 1
55 55 VA/W 2
MODEL
MOUNTING
S Surface Wall
R Recessed Wall
T Recessed Ceiling T-Grid
Surface Mount Housing
1 Nickel-Cadmium battery type
2 Lead Calcium battery type
ELECTRONICS
SPECIFICATIONS
LPS32
LPS55
LPS20
LPS35
INPUT/
OUTPUT
VOLT
MAX
INPUT
(A)
120V
0.34
277V
0.15
120V
0.54
277V
0.23
120V
0.25
277V
0.11
120V
0.37
277V
0.16
WEIGHT WITH
BATTERIES
POWER RATING
(VA/W)
14lbs.
32
18lbs.
55
TEMP.
RANGE
20°C
-30°C
11lbs.
SYSTEM DC
VOLTAGE
RECHARGE
TIME (HR)
12
20
96
TEST
AC
CHG
INV
PUSH
ON
ON
ON
ACCESSORIES
8.88”
ORDER SEPARATELY
RTSLP
12lbs.
7.38”
Operates with normally-on, normally-off and switched loads
• AC lockout and Low Voltage Battery disconnect
• Brownout 14.75”
Protection: Automatically transfers
to emergency
4.38”
3.13” power
(models
(models
• Overload and Short Circuit Protection: Protects
AC and DC
LPS-20
LPS-35
• Charger Type: Temperature compensated, dual-mode
& LPS-32 )
& LPS-55)
Recessed
Mount Housing
• LED status indicator and push button test switch
• Load can be up to 1000 feet away
•
35
Remote Test Switch for LPS
16.25”
Surface Mount Housing
Ceiling T-grid Mount Housing
.50 Extrusion from wall
after installation
4.75”
8.56”
8”
7.38”
23.88”
14.75”
Recessed Mount Housing
TEST
AC
CHG
INV
PUSH
ON
ON
ON
4.38”
3.13”
(models
LPS-35
& LPS-55)
(models
LPS-20
& LPS-32 )
6.19”
8.88”
16.25”
Ceiling T-grid Mount Housing
.50 Extrusion from wall
after installation
4.75”
411
8.56”
8”
LG
Single-Phase Central Lighting Inverter
FEATURES
•
•
•
•
•
•
ORDERING INFORMATION
LG
MODEL
CAPACITY
1 100 VA/W
2 250 VA/W2
MOUNTING
S Surface Wall Mounting
T Recessed Ceiling Mounting1
SELF DIAGNOSTICS
Blank None
I Spectron Self-test/Selfdiagnostic Electronics3
Only available on 100 VA/W models
Housing (LG2SLB) and batteries (0120935) ship in separate cartons
3
Only available on 250 VA/W models
1
2
LG1S with
TRMLG Trim Plate
LG1T
LG1S
SPECIFICATIONS
ELECTRONICS
BASE
CATALOG
NUMBER
FORM AND
FIT
WEIGHT
(LB) WITH
BATTERIES
POWER
RATING(VA/W)
POWER
FACTOR
MAXIMUM INPUT
CURRENT (A)
SYSTEM DC
VOLTAGE
RECHARGE
TIME(HR)
LG1S
Wall Mount
Surface
43
100
0.8 lead to
0.75 lag
120 VAC: 1.02 A
277 VAC: 0.47 A
12
48
LG1T
Ceiling Mount
Recessed
T-grid
45
100
0.8 lead to
0.75 lag
120 VAC: 1.02 A
277 VAC: 0.47 A
12
48
LG2S
Wall Mount
Surface
78
250
0.8 lead to
0.7 lag
120 VAC: 2.5 A
277 VAC: 1.1 A
24
72
•
•
•
•
•
•
Interruptible design; automatically transfers in 2 seconds or less
Load can be up to 1,000 feet away
Temperature compensated battery charger
Operates with normally-on, normally-off and switched loads
LVD, AC lockout, short circuit, current limiting, overload and
brownout protection
LED status indicator and push button test switch
ACCESSORIES
MODEL DESCRIPTION
WGTW Wire Guard for LG1S
RTSLG Remote Test Switch for LG2S
TRMLG Recessed Mount Trim Plate for LG1S; Refer to
existing specification sheet
412
I N V E RT E R S
I N V E RT E R S
•
AC output provides full lumen output for emergency lighting loads in commercial or industrial applications
Compatible with incandescent, LED, compact and linear fluorescent lamps
White painted steel enclosure
Offline operation for greater efficiency
Maintenance-free lead-calcium batteries
Temperature range: 20°C to 30°C (68°F to 86°F)
UL 924 Wet Location Listed
LG
Single-Phase Central Lighting Inverter
LG1S
Wall Mount Surface Model
I N V E RT E R S
4.313"
5.5"
5.5"5.5"
I N V E RT E R S
4.313"
14.188" 14.188"
5.5"
23.875"
18.125" 18.125"
4.313"
14.188"
5.5"
5.5"
10.563"
LG1T
Recessed T-Grid Ceiling Mount Model
23.875"
23.875"
18.125"
5.75"
10.563"
10.313"
10.125"
23.875"
23.875"
7"
5.75"
14.189"
LG1S
with Wall Mount Recessed Trim Plate
14.189"
10.313"
10.563"
.625"
.625"
10.125"
18.343"
23.875"
5.75"
7"
10.200"
18.125"
21.689"
18.125"
21.689"
10.313"
10.125"
14.189"
.625"
8.563"
18.343"
7"
4.25"
4.25"
10.200"
LG2S
Wall Mount Surface Model
8.250"
8.563"
18.343"
18.125"
21.689"
18.343"
8.563"
4.25"
10.200"
8.563"
8.250"
18.343"
8.563"
413
DLS
Single-Phase Central Lighting Inverter
FEATURES
•
I N V E RT E R S
•
•
•
•
•
•
AC output provides full lumen output for emergency lighting loads in commercial or industrial applications
Compatible with any lighting load including incandescent, fluorescent,
HID and LED lamps
Painted steel enclosure
Offline operation up to 98% efficient
Maintenance-free lead-calcium batteries
Temperature range: 20°C to 30°C (68°F to 86°F)
UL 924 Listed; Made in USA
ORDERING INFORMATION
DLS
MODEL
INPUT/OUTPUT
VOLTAGE
120 120VAC
277 277VAC
CAPACITY RATING1
400 400 VA/Watts
525 525 VA/Watts
750 750 VA/Watts
1000 1000 VA/Watts
1500 1500 VA/Watts
2100 2100 VA/Watts
1
Output Circuit Breakers:
• 400 VA and 525 VA models
are supplied with one, 15 amp
normally on circuit breaker
• 750 VA through 2100 VA
models: output circuit breakers
are optional
OUTPUT CIRCUIT
BREAKER VOLTAGE
RATING
A 120VAC
B 277VAC
OUTPUT CIRCUIT
BREAKER TYPE
Blank
N
Normally-On
Normally-Off2
A maximum of 4, normallyoff circuit breakers may be
specified. Maximum rating
of normally-off circuit
breakers is 20 amperes.
Normally-off circuit
breakers include a built-in,
15-minute retransfer delay
to accomodate HID lighting
loads
2
OUTPUT CIRCUIT
BREAKER AMPERE
RATING
15 15 Amperes
20 20 Amperes
25 25 Amperes
30 30 Amperes
OUTPUT CIRCUIT
BREAKER QUANTITY
01 1 circuit breaker
02 2 circuit breakers
03 3 circuit breakers
04 4 circuit breakers
05 5 circuit breakers
06 6 circuit breakers
07 7 circuit breakers
08 8 circuit breakers
09 9 circuit breakers
10 10 circuit breakers
ELECTRONICS
•
•
•
•
•
•
Uninterruptible “no break” transfer
Microprocessor controlled pulse width modulation (PWM) using IGBT technology
LVD, short-circuit, current limiting and overload protection
True sine wave output
Power factor range of 0.8 lead to 0.75 lag
LED status indicator, audible alarm system and push button test switch
400VA to 525VA Models
(may be wall mounted)
414
750VA to 2100VA Models
(floor mount only)
OUTPUT CIRCUIT
BREAKER
SUPERVISION
Blank Monitored
U Unmonitored3
3
A maximum of 6
monitored or 10
unmonitored normally
on circuit breakers may
be specified
415
COMPASS
Offers products such as emergency lighting units and exit signs for
the commercial and institutional market place. Compass provides
value engineered-product without sacrificing performance.
416
CU2
LED Emergency Light
FEATURES
EMERGENCY
FLOODLIGHTS
•
•
•
•
•
•
•
Emergency unit for commercial applications
UV stable thermoplastic white or black housing available
Quick installation with fully adjustable lamp-heads
LED Lamps with a life-cycle of more than 10 years
Dual-voltage 120 or 277V AC input
Remote capacity or extended runtime option
Long-life Nickel Cadmium battery with fully automatic charger
UL 924 Damp Location Listed
EMERGENCY LGIHTING
•
ORDERING INFORMATION
CATALOG NUMBER
CU2
DESCRIPTION
White Thermoplastic, Dual-Head LED Emergency Light , 120/277 Input, Damp Location Listed, 3 VDC, 1 Watt
CU2B
Black Thermoplastic, Dual-Head LED Emergency Light, 120/277 Input, Damp Location Listed, 3 VDC, 1 Watt
CU2RC
White Thermoplastic, Dual-Head LED Emergency Light, 120/277 Input, Damp Location Listed, Remote Capacity, 3 VDC, 1 Watt
CU2RCB
Black Thermoplastic, Dual-Head LED Emergency Light, 120/277 Input, Damp Location Listed, Remote Capacity, 3 VDC, 1 Watt
Note: Remote Capacity Unit will only power the Compass Indoor and Outdoor Remote(CIR and COR Series)
MATCHING REMOTE FIXTURES
MODEL DESCRIPTION
CIR LED Indoor Remote Heads
COR LED Outdoor Remote Heads
ACCESSORIES
CU2B
MODEL DESCRIPTION
WGLZ
Wireguard- 6.25” H X 14” W X 4” D
ELECTRONICS
•
•
90 minute emergency operation
Test switch and LED AC-on indicator light
Single Carton Weight: 1 lbs.
Master Carton Quantity: 12 each
C IRD
C IRS
C 0RS
C 0RD
417
CE
LED Emergency Exit Sign
FEATURES
•
EXIT SIGNS
•
•
•
•
•
•
Exit sign for commercial applications
UV stable thermoplastic white or black housing available
Long life LED lamps provide bright, even illumination
Universal end or ceiling mount
Dual-voltage 120 or 277V AC input
Remote capacity or extended runtime option
Long-life Nickel Cadmium battery with fully automatic charger
UL 924 Damp Location Listed
EXIT
•
ORDERING INFORMATION
CATALOG NUMBER
CER
DESCRIPTION
White Thermoplastic Exit, Universal Face, Red LED Emergency Exit
CERB
Black Thermoplastic Exit, Universal Face, Red LED Emergency Exit
CEG
White Thermoplastic Exit, Universal Face, Green LED Emergency Exit
CEGB
Black Thermoplastic Exit, Universal Face, Green LED Emergency Exit
CERRC
White Thermoplastic Exit, Universal Face, Red LED Emergency Exit,Remote Capacity
CERRCB
Black Thermoplastic Exit, Universal Face, Red LED Emergency Exit,Remote Capacity
CEGRC
White Thermoplastic Exit, Universal Face, Green LED Emergency Exit, Remote Capacity
Note: Remote Capacity Unit will only power the Compass Indoor and Outdoor Remote(CIR and COR Series)
12.6”12.6”
MATCHING REMOTE FIXTURES
MODEL DESCRIPTION
CIR LED Indoor Remote Heads
COR LED Outdoor Remote Heads
ACCESSORIES
MODEL DESCRIPTION
WGLX
Wall Mount Wireguard- 10” H X 14” W X 2.25” D
CEGB
ELECTRONICS
•
•
90 minute emergency operation with 1 double or 2
single remotes
Test switch and LED AC-on indicator light
C IRD
CIR S
C 0RS
C0RD
418
Single Carton Weight: 2 lbs.
Master Carton Quantity: 6 each
CC
Combination LED Exit/Light
FEATURES
•
•
EXIT
•
•
•
•
•
EXIT SIGNS
•
Combination unit for commercial applications
UV stable thermoplastic white or black housing available
Long life LED lamps in exit sign rated at 50,000 hour life expectancy
LED Lamps with a life-cycle of more than 10 years
Dual-voltage 120 or 277V AC input
Remote capacity or extended runtime option
Long-life Nickel Cadmium battery with fully automatic charger
UL 924 Damp Location Listed
ORDERING INFORMATION
CATALOG NUMBER
DESCRIPTION
CCR
White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters
CCRB
Black Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters
CCG
White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Green Letters
CCGB
Black Thermoplastic, Combination Exit/Emergency Light, Universal Face, Green Letters
CCRRC
White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters, Remote Capacity
CCRRCB
Black Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters, Remote Capacity
CCGRC
White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Green Letters, Remote Capacity
Note: Remote Capacity Unit will only power the Compass Indoor and Outdoor Remote(CIR and COR Series)
MATCHING REMOTE FIXTURES
MODEL DESCRIPTION
CIR LED Indoor Remote Heads
COR LED Outdoor Remote Heads
ACCESSORIES
MODEL DESCRIPTION
WGEL
Wall Mount Wireguard- 8” H X 20” W X 8” D
CCGB
ELECTRONICS
•
•
90 minute emergency operation with 1 double or 2
single remotes
Test switch and LED AC-on indicator light
C IRD
C IRS
C O RS
Single Carton Weight: 2.5 lbs.
Master Carton Quantity: 6 each
C O RD
419
CIR
LED Indoor Remote
FEATURES
•
R E M OT E H E A D S
•
•
•
•
•
Single or Double lamp-head remote with base-plate
LED life-cycle of more than 10 years
Quick installation
Dual-voltage 120 or 277V AC input
UL924 Damp Location Listed
Fully adjustable lamp-heads
ORDERING INFORMATION
CATALOG NUMBER
CIRS
CIRD
DESCRIPTION
LED Remote, Single Mounting Base, 3 VDC, 1 Watt
LED Remote, Double Mounting Base, 3 VDC, 1 Watt
Note: Powered by the Compass Exit, Combo or Emergency Light with Remote Capacity
CIRS
Single Remote Carton Weight: 1 lbs.
Master Carton Quantity: 20 each
420
12.6”
CIRD
Double Remote Carton Weight: 1.2 lbs.
Master Carton Quantity: 20 each
COR
LED Outdoor Remote
FEATURES
•
•
•
•
Single or Double lamp-head remote with base
LED life-cycle of more than 10 years
Quick installation
Fully adjustable lamp-heads
Fully gasketed for application in wet environment
R E M OT E H E A D S
•
ORDERING INFORMATION
CATALOG NUMBER
CORS
CORD
DESCRIPTION
LED Outdoor Remote, Single, Mounting Base, 3 VDC, 1 Watt
LED Outdoor Remote, Double, Mounting Base, 3 VDC, 1 Watt
Note: Powered by Compass Exit, Combo or Emergency Light with Remote Capacity
CORS
CORD
Single Remote Carton Weight: 1 lbs.
Master Carton Quantity: 20 each
Double Remote Carton Weight: 1.2 lbs.
Master Carton Quantity: 20 each
421
CUW
Decorative LED AC/Emergency Light
EMERGENCY LIGHT
FEATURES
• Normally-on and emergency operation
• Durable die-cast aluminum housing
• Prismatic polycarbonate refractor
• 10 year LED life cycle
• Long-life Nickel Cadmium battery
• Fully sealed and gasketed design
• Includes self-diagnostic/self-test
• Includes conduit entry at top of unit
• Optional heater and photo-cell
• Temp. range standard, 0°C to 50°C with heater, -20°C to 40°C
• UL924 Wet Location Listed
ORDERING INFORMATION
CATALOG NUMBER
DESCRIPTION
CUWZ
Die-Cast, Normally on/Emergency, 0° to 50°C, Dark Bronze Finish
CUWZ-HTR
Die-Cast, Normally on/Emergency, -20° to 40°C, with Heater, Dark Bronze Finish
CUWZ-HTR-PC
Die-Cast, Normally on/Emergency, -20° to 40°C, with HTR and Photo-Conrol, Dark Bronze Finish
6.54”
ELECTRONICS
•
•
•
•
Universal 100-300VAC input
4.8VDC Nickel Cadmium battery
Battery re-charge within 24 hours
Fully automatic solid-state charger
10.47”
3.78”
Single Carton Weight: 4.0 lbs.
Master Carton Quantity: 6 each
422
CCE
Thin Die-Cast LED Emergency Exit Sign
FEATURES
•
•
•
•
•
•
EXIT SIGNS
•
Thin die-cast aluminum Exit sign for commercial or light industrial applications
Painted black housing with brushed aluminum face
Long life LED lamps provide bright, even illumination
Universal end or ceiling mount with canopy included
Dual-voltage 120 or 277V AC input
Emergency models include long-life Nickel Cadmium battery
UL 924 Damp Location Listed
ORDERING INFORMATION
CATALOG NUMBER
CCESRE
DESCRIPTION
Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Red Letters, Emergency
CCEDRE
Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Red Letters, Emergency
CCESGE
Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Green Letters, Emergency
CCEDGE
Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Green Letters, Emergency
CCESR
Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Red Letters, AC
CCEDR
Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Red Letters, AC
CCESG
Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Green Letters, AC
CCEDG
Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Green Letters, AC
12.6”
ELECTRONICS
•
•
•
90 minute emergency operation
AC or Emergency operation
Test switch and LED AC-on indicator light
Single Carton Weight: 2.8 lbs.
Master Carton Quantity: 8 each
423
CEL
Edge-Lit LED Emergency Exit Sign
FEATURES
•
•
•
•
•
•
•
EXIT
EXIT SIGNS
•
Edgelit exit sign for architectural applications
Brushed aluminum housing with field installed directional arrows
Long life LED lamps provide bright, even illumination
Recessed or surface mount with canopy included
Mirror divider on single and double-face models
Dual-voltage 120 or 277V AC input
Emergency models include long-life Nickel Cadmium battery
UL 924 listed
ORDERING INFORMATION
CATALOG NUMBER
CELS1RNE
DESCRIPTION
Edge-Lit Exit, Surface Mount, Single Face, Red Letters, Brushed Aluminum, Battery
CELS1GNE
Edge-Lit Exit, Surface Mount, Single Face, Green Letters, Brushed Aluminum, Battery
CELS2RNE
Edge-Lit Exit, Surface Mount, Double Face, Red Letters, Brushed Aluminum, Battery
CELS2GNE
Edge-Lit Exit, Surface Mount, Double Face, Green Letters, Brushed Aluminum, Battery
CELR1RNE
Edge-Lit Exit, Recessed Mount, Single Face, Red Letters, Brushed Aluminum, Battery
CELR1GNE
Edge-Lit Exit, Recessed Mount, Single Face, Green Letters, Brushed Aluminum, Battery
CELR2RNE
Edge-Lit Exit, Recessed Mount, Double Face, Red Letters, Brushed Aluminum, Battery
CELR2GNE
Edge-Lit Exit, Recessed Mount, Double Face, Green Letters, Brushed Aluminum, Battery
ELECTRONICS
•
•
90 minute emergency operation with 1 double or 2
single remotes
Test switch and LED AC-on indicator light
ADDITIONAL MOUNTING OPTIONS
Single Carton Weight
Surface Mount: 3 lbs.
Recessed Mount: 5 lbs.
Master Carton Quantity
Surface Mount: 6 each
Recessed Mount: 3 each
424
Surface Mount
Recessed Wall
Recessed Ceiling
CU2W
Wet Location LED Emergency Light
FEATURES
•
•
•
•
•
•
•
•
Emergency unit for wet location or light industrial applications
UV stable thermoplastic grey housing available
Quick installation with fully adjustable lamp-heads
LED Lamps with a life-cycle of more than 10 years
Dual-voltage 120 or 277V AC input
Provided with water-proof test switch and AC-On indicator
Remote capacity or extended runtime standard
Long-life Nickel Cadmium battery with fully automatic charger
UL 924 Wet Location Listed
EMERGENCY LIGHTING
•
ORDERING INFORMATION
CATALOG NUMBER
CU2WG
DESCRIPTION
Wet Location LED emergency light, Dual-Head Fully Adjustable, Grey Finish, Remote Capacity, 120/277 Input, 1.9 watts
CU2WB
Wet Location LED emergency light, Dual-Head Fully Adjustable, Black Finish, Remote Capacity, 120/277 Input, 1.9 watts
Note: Unit will only power 1 each Compass CWRD or 2 each CWRS remotes
C WR S
MATCHING REMOTE FIXTURES
MODEL DESCRIPTION
CWRS LED Outdoor Remote, Single
CWRD LED Outdoor Remote, Double
ACCESSORIES
MODEL DESCRIPTION
WGEL
Wireguard- 8” H X 20” W X 8” D
ELECTRONICS
•
•
90 minute emergency operation with 1 double or 2
single remotes
Test switch and LED AC-on indicator light
4.5”
4.5”
2.6”
Single Carton Weight: 7.5 lbs.
Master Carton Quantity: 4 each
4.25”
10”
4.5”
4.25”
7”
0.9”
7”
0.9”
425
CEW
Wet Location LED Emergency Exit Sign
FEATURES
•
•
EXIT SIGNS
•
•
•
•
•
•
Exit sign for wet location or light industrial environments
UV stable thermoplastic grey housing with polycarbonate lens
Long life LED lamps provide bright, even illumination
Single face end, wall or ceiling mount
Double face end or ceiling mount
Dual-voltage 120 or 277V AC input
Long-life Nickel Cadmium battery with fully automatic charger
UL 924 Wet Location Listed
ORDERING INFORMATION
CATALOG NUMBER
CEWSRE
DESCRIPTION
Thermoplatic, Wet Location Exit, Single-Face, Red Letters, Emergency
CEWDRE
Thermoplatic, Wet Location Exit, Double-Face, Red Letters, Emergency
CEWSGE
Thermoplatic, Wet Location Exit, Single-Face, Green Letters, Emergency
CEWDGE
Thermoplatic, Wet Location Exit, Double-Face, Green Letters, Emergency
12.6”
ELECTRONICS
•
•
4.4”
90 minute emergency operation
Test switch and LED AC-on indicator light
5.5”
9.3”
8.5”
12.5”
2.5”
Single Carton Weight: 4.3 lbs.
Master Carton Quantity: 6 each
426
CWC
Wet Location Combination Exit/Emergency Light
FEATURES
LED based exit/emergency light for wall, ceiling or end mounting
Includes Self-Test/Self-Diagnostics
Housing made of 5VA flame retardant polycarbonate in white finish
Exit face-plate and lamp-head shield made from high impact, UV stable polycarbonate
Fully adjustable LED lamp-heads at 3.6W each
Long life Nickel Cadmium Battery
Temperature Range: 0°C to 50°C, CT Option: -20°C to 50°C
UL924 Wet Location Listed
EXIT SIGNS
•
•
•
•
•
•
•
•
ORDERING INFORMATION
CATALOG NUMBER
CWC1RW
DESCRIPTION
White Housing, Single Face, Red Letters
CWC2RW
White Housing, Double Face, Red Letters
CWC1GW
White Housing, Single Face, Green Letters
CWC2GW
White Housing, Double Face, Green Letters
CWC1RW-CT
White Housing, Single Face, Red Letters, Cold Temperature Operation
CWC2RW-CT
White Housing, Double Face, Red Letters, Cold Temperature Operation
CWC1GW-CT
White Housing, Single Face, Green Letters, Cold Temperature Operation
CWC2GW-CT
White Housing, Double Face, Green Letters, Cold Temperature Operation
ELECTRONICS
•
•
•
•
•
120/277VAC input
AC lockout and Low Voltage disconnect
Battery re-charge within 24 hours
Self-Test/Self-Diagnostic circuitry
Magnetic No Touch Testing
315.0 (12.40’)
150.0 (5.91”)
150.0 (5.91”)
346.7
(13.65”)
323.7
(12.74”)
104.0 (4.09”)
Single Carton Weight: 8.0 lbs.
Master Carton Quantity: 4 each