Chemical Resistance Chart - Emerson Process Management

advertisement
PN 41-6018/rev.C
January 2010
Chemical Resistance Chart
MATERIALS LEGEND
Chemraz
Silicone
EPDM
Viton2
PPS
PEEK
PES
Tefzel2
Teflon2
PVDF
PP
CPVC
PVC
Proprietary Dupont Polymer (Type sas)
Proprietary Dupont Polymer (Type sas)
Polydimethylsiloxane
Ethylene Propylene Diene Monomer
Vinylidiene Fluoride Hexafluoropropylene
Polyphenylene Sulfide (Ryton)
Polyetheretherketone
Polyethersulfone
Ethylene Tetrafluoroethylene (ETFE)
TFE Fluorocarbons
Polyvinylidene Fluoride (KYNAR 1)
Polypropylene
Chlorinated Polyvinyl Chloride
Polyvinyl Chloride
DESCRIPTION
Kalrez
Nickel based alloy
MATERIAL
Hastelloy C4
1
Kynar
is
a trademark Elf Atochem North America, Inc.
2
Teflon,
Tefzel , Viton, and Delrin are registered trademarks of E. I. du Pont de Nemours & Co.
3
Aflas is a registered trademark of Asahi Glass Co., Ltd.
Hastelloy C is a registered trademark of Cabot Corp.
4
To the best of our knowledge the information contained herein is
accurate. However, Rosemount Analytical Inc., assumes no liability
whatsoever for the accuracy or completeness of the information
contained herein. This chemical resistance chart is to be used as a
guide only. There is no warranty expressed or implied and the final
determination of material suitability is the responsibility of the user.
1
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
2
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
3
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
4
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
5
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
6
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
7
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
8
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
9
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
10
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
11
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
12
A: to 120°C, B: to 100°C, C: to 80°C, D: to 60°C, E: to 40°C, R: Room temperature, X: Not recommended, *: Some mechanical damage possible, ?: Questionable data, +: May exceed (less data)
13
The right people,
the right answers,
right now.
Emerson Process Management
2400 Barranca Parkway
Irvine, CA 92606 USA
Tel: (949) 757-8500
Fax: (949) 474-7250
http://www.raihome.com
© Rosemount Analytical Inc. 2010
Credit Cards for U.S. Purchases Only.
http://www.raihome.com
ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE
8
Download