F5 | arabesque5

advertisement
F5
182
| arabesque 5
integrations
w w w.al i ghts .c om
a·light
F5
| arabesque 5
project
type
quantity
Optics
a·cirrus™ regressed | t-bar
WISP™ | t-bar
a·cirrus™ | trim flange
HTLO™ | regressed gyp
Lengths:
Mounting:
non-standard nominal individual lengths: 5', 6', 7', 9', 10', 11'
gyp trimless
nominal rows longer than 24'
1/2" trim
exact lengths to the nearest 100th of an inch
t-bar
recessed
Additional Integrations Selections
+
Optons:
custom mounting
custom finish
precise lengths
Design-Assist:
shadow molding perimeter
in-house design-assist team manages your unique project
hidden grid
Cross Sections
Multiple configurations available sampling shown
T5
T5
T5
8”
lens
15/16" t-bar "X"
lens
9/16" t-bar "T"
lens
9/16" slot t-bar "N"
LED
5”
7-3/4”
aper ture
T5
T8
T5
lens
shadowmold +
gyp flange "Z" (paint over flange)
(paint over flange)
Available Light Platforms
LED
integrations
T5
T8
lens
1" regressed gyp flange "RG"
lens
1/2" trim flange "XP"
Available Mounting
recessed
controls
friendly
w w w.al i ghts .c om
Version | March 2014
183
F5
| arabesque 5
integrations
Linear Dimensions:
Standard lengths available are located on the 'elements' spec sheet. All other
lengths should be specified as follows...
Shadowmold. Dual-flanged housing creates a 5/8" shadowed gap along
wall/surface with choice of ceiling flange on opposite side for
perimeter mounting. Shadowmold spacer is painted black. Exposed
side of housing next to wall is unpainted - housing may be
field-painted if necessary.
Nominal Damp Location Row
R___: Specify in nominal feet.
Choose when nominal length is acceptable.
Actual length will be shorter or longer due to metric lamp lengths. Lengths over
12' are comprised of multiple sections.
Examples: a nominal 54ft row begins as F5R54; a 7ft individual as F5R7.
Finish:
Electrostatically applied powder coat finish.
Construction:
60% recycled aluminum extruded housing. Steel endcaps with earthquake
suspension cable attachment holes.
Nominal Wet Location Run
G___: Specify in nominal feet.
Choose when nominal length is acceptable and wet location is necessary.
Actual length will be shorter or longer due to metric lamp lengths. Lengths over
12' are comprised of multiple sections with minimal endcaps, joined via wet rated
connectors (by others).
Examples: a nominal 54ft row begins as F5G54; a 7ft individual as F5G7.
Listing:
UL/CUL. Damp or Wet Location.
Companion Luminaires:
F3 suspended/ceiling/wall.
Exact Row
M___: Specify overall length in inches to the nearest hundredth.
Choose when exact lengths are required as determined by space constraints, etc.
Submittals required. Lengths over 12' are comprised of multiple sections.
Examples: an exact 54ft row begins as F5M648.00; a 7ft individual as F5M84.00.
Patterns are not available due to large housing size.
Lamping:
LED. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See
wattage/lumen table for specifications per foot. All specifications are
subject to change.
LED
T5/T5HO. Single or dual lamps in cross section or staggered single lamping.
Low-profile electronic, high power factor, program start, sound rating A,
inherent thermal protection, UL listed Class P, <10% THD. Dimming:
T5
specify manufacturer/model.
T8. Single or dual lamps in cross section or staggered single lamping.
Low-profile electronic, choose low, standard or high power factor,
instant start, sound rating A, inherent thermal protection, UL listed
T8
Class P, <10% THD. Specify if program start or custom ballast factor
required. Dimming: specify manufacturer/model.
Mounting:
Flush gyp/hard ceiling or wall. “Flangeless” appearance for gyp or other hard
ceiling/wall. Flange is not visible and is not factory-painted. Raw
aluminum flange must be attached to blocking (by others), mudded
over and painted by ceiling contractor for flangeless appearance.
Regressed flush gyp/hard ceiling or wall. Same as above except flange
raises lens up into ceiling. "RG" is 1" regressed resulting in a 4.5”
height. Interior 1" regressed portion is exposed raw aluminum and
visible on both sides unless finish is chosen. Contractor should apply
ceiling paint if finish is not chosen.
Trim Flange. 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/
wall that requires a minimal flange covering the ceiling cut-out edge.
Choose finish color for trim flange.
T-Bar. Standard T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot
ceiling. Raw aluminum flange sits on T-Bar, is not visible
and is not painted.
Legend:
1.
Emergency ballast not applicable on lengths 3ft or less.
8.
“S” optics recommended for use with LED.
2.
Multi-circuiting: submit multi-circuiting requirements during submittal process.
9.
3.
Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter.
Staggered lamping not available on lengths less than 8ft. 8ft length uses 3-3ft lamps.
12ft uses 2-3ft and 2-4ft lamps.
4.
Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight
harvesting. Requires 0-10V dimming ballast.
5.
Lens is required for use in wet or natatorium locations.
6.
Not available with staggered or dual fluorescent lamping. Only 1 board in cross
section is used for LED.
7.
Staggered lamping not recommended with HTLO™.
184
w w w.al i ghts .c om
a·light
| arabesque 5
project
Series:
F5
per foot
LS
LH
symmetric
2 boards in cross
watts/ft
lumens/ft
10
1200
20
2400
a·cirrus™ lens
HTLO™ lens
WISP™ lens
a·wash™ kicker + a·cirrus™
a·wash™ kicker + HTLO™
a·wash™ kicker + WISP™
Row or Pattern Type:
for standard lengths available: see 'elements' specification sheet
damp location nominal length row
R___
wet location nominal length run
G___
exact length row
M___
Length:
_____
nominal length "R" or "G" (specify in feet)
exact length "M" (specify in inches to nearest 100th)
_____
Lamping:
LED standard output 8 LS
LED high output 8 LH
T5 (1)
S
T5HO (1)
H
T5 (2)
D
T5HO (2)
O
T5 staggered 9 2
T5HO staggered 9 4
T8 (1) low output
T8L
T8 (1) standard output
T8S
T8 (1) high output
T8H
T8 (2) low output
T8LD
T8 (2) standard output
T8SD
T8 (2) high output
T8HD
T8 staggered low output 9 T8LS
T8 staggered standard output 9 T8SS
T8 staggered high output 9 T8HS
LED Temp (if applicable):
3000k
30
3500k
35
4000k
40
Voltage:
universal 120V - 277V
U
120V
1
277V
2
347V
3
LED
type
flush gyp/hard lid - no finish
1" regressed gyp - optional finish
trim flange - choose finish
t-bar 9/16” - no finish
t-bar 15/16” - no finish
t-bar 9/16” slot - no finish
shadowmold + flush gyp - no finish
shadowmold + 9/16" t-bar - no finish
shadowmold + 15/16" t-bar - no finish
custom
a∙lightanium™
satin white
satin black
textured eggshell white
other - specify RAL#
no finish (t-bar or gyp/no MR16)
custom
dimming - specify manufacturer, model/series and voltage
emergency - specify model/series or lumens
external fusing
multi-circuit
new york city code
chicago plenum code
occupancy sensor
photocell/daylight sensor
natatorium application
wet label
quantity
Optics:
A
7
H
8
S
6
KA
6
KH
6
KS
Mounting:
G
RG
XP
T
X
N
Z
Y
U
C
Finish:
T
W
B
E
O
C
Options:
D
1
E
F
2
M
N
C
3
O
4
P
5
K
5
Q
recessed
F5
asymmetric
1 board in cross
watts/ft lumens/ft
5
600
10
1200
Lumens at board at 4000k.
Consult IES files online for delivered lumens.
Specifications subject to change.
integrations
w w w.al i ghts .c om
Version | March 2014
185
Download