NEMA Type 12 Filterfans

advertisement
NEMA Type 12 Filterfans®
Features/Benefits:
Patented four-corner “click & fit” system – Enhancing our traditional
“click & fit” system, we created an easier to assemble and tighter seal
against multiple gauge enclosure sizes.
Special Fluted Filter – This special Type 12 filter increases time between
maintenance by three times and allows for greater CFM in dirty environments.
True hardware-free mounting – Our Filterfans do not require any screws
to create the pressure on our gasket material to maintain a Type 12 seal
against the enclosure. Removing these screws reduce the labor time to
mount the Filterfans by greater than 200%.
Filterfans®
Easy to change filter – The patented hinge system allows for a quick, handsfree change. This reduces the number of lost and damaged grills when they
items are placed on floors and carried away from the machine.
UL tested NEMA Type 12 rating - Our Filterfans are tested by UL to UL
50 Type 12 and NITW2 categories allowing Integrators to maintain the
enclosure ratings of the enclosure while maintaining the high CFM
ratings of our original Filterfans.
www.filterfanusa.com
Options:
Table of Contents
• Low EMC Option – If low EMI emissions are a concern for your application,
please contact Pfannenberg for our EMC version of these Filterfans.
• IP 55, Outdoor/Washdown Option – By using a UV resistant grill, Pfannenbergís
new Filterfans meet the European IP55 rating for enclosures.
• Rainhood Option – If more security is needed in outdoor or washdown
environments then consider our PF-RH-XXXX series.
• Special Colors/Voltages – Many of our Filterfans are available is special colors
and voltages. Please consult with the factory.
NEW FilterFan
Introduction
New PF
New PTF
3rd Gen PF
PF 11000/22000, PFA 1/20000
PF 32000, PFA 30000
PF 42500/43000, PFA 40000
PF 65/66/67000, PFA 60000
PTF 60500/60700/61000
PF Series - 3rd Generation
PFA Series - 3rd Generation
PF-RH Rainhoods
Panel Fans
27
44-45
46-47
48-49
50-51
52-53
54-55
56
57
58
43
Filterfan PF 11000-22000 / Exhaust Filter PFA 10000-20000
l Maintains a UL Tested NEMA Type 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File #E175229,
CE approved for European use
l Patented “Click & Fit” design provides a hardware free installation!
l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire
approved material
Options: EMC, IP55, Light Grey or Black Grills
NEMA Type
Airflow data
PF 11000
Filter material
Type 12 filter mat
Approvals
Mounting
PFA 10000
PFA20000
PF 22000
Type 12 filter mat
Type 12 filter mat
Unimpeded airflow
17 CFM
38 CFM
-
Capacity free-flow
10 W/K
21 W/K
-
Airflow in combination
(Filterfan + Exhaust Filter)
11 CFM
(PF 22000 + PFA 20000)
28 CFM
(PF 22000 + PFA 20000)
-
Capacity in combination
(Filterfan + Exhaust Filter)
6 W/K
(PF 22000 + PFA 20000)
15 W/K
(PF 22000 + PFA 20000)
-
38 Pa
57 Pa
-
Max. static pressure (Airflow = 0 m3/h)
Filtration efficiency
88%
91%
88/91%
Filter material grade
G 3 (DIN EN 779)
G 4 (DIN EN 779)
G3/ G4 (DIN EN 779)
100%
100%
Duty cycle
Technical data
PF 11000
AC
PF 22000
DC
AC
PFA 10000/
PFA 20000
DC
Outside dimensions in mm
(height x width x installation depth)
109 x 109 x 62
109 x 109 x 49
145 x 145 x 70
145 x 145 x 64
109 x 109 x 26/
145 x 145 x 26
Bearing type
sleeve bearings
ball bearings
sleeve bearings
ball bearings
-
Fitting position
vertical
any
vertical
any
-
Construction
Weight
0.55 kg
housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO
0.16 kg
0.7 kg
0.44 kg
Safety protection
in accordance with DIN 31 001
Color
0.06 kg / 0.12 kg
-
RAL 7035, RAL 7032 or black, other colors on request
Connection
terminal strip
System of protection
2 wires, 310 mm long
-
NEMA Type 12, IP 55 (EN 60 529), when installed as specified
AC
PF 11000
AC
DC
AC
PF 22000
AC
DC
Rated voltage
230 V
115 V
24 V
230 V
115 V
24 V
Power consumption
11 W
11 W
2W
18 W
20 W
5W
Electrical data
44
Airflow data:
PF 11000
PF 22000
[in • H2O] .098
.086
[in • H2O] .172
.147
.061
Static pressure increase
Static pressure increase
.074
.049
.037
PFA 10000
.025
PF 11000
.012
.123
.098
PFA 20000
.074
.049
PF 22000
.025
0
0
0
3
6
9
12
15
18 [CFM]
Airflow
Airflow
Mechanical data:
PF 11000
PF 11000 + PFA 10000
PFA 10000
Cutout
Filterfans®
Installation cutout
92 mm x 92 mm*
standard punch size
Mechanical data:
PF 22000
PF 22000 + PFA 20000
PFA 20000
Cutout
Installation cutout
125 mm x 125 mm *
45
Filterfan PF 32000 / Exhaust Filter PFA 30000
l Maintains a UL Tested NEMA Type 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File #E175229,
CE approved for European use
l Patented “Click & Fit” design provides a hardware free installation!
l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire
approved material
Options: EMC, IP55, Light Grey or Black Grills
NEMA Type
Approvals
Airflow data
PF 32000
Filter material
NEMA Type 12 filter mat
Mounting
PFA 30000
Unimpeded airflow
65 CFM
Capacity free-flow
37 W/K
-
Airflow in combination
(Filterfan + Exhaust Filter)
38 CFM
(PF 32000 + PFA 30000)
-
Capacity in combination
(Filterfan + Exhaust Filter)
21 W/K
(PF 32000 + PFA 30000)
-
Max. static pressure (Airflow = 0 m3/h)
61 Pa
-
Filtration efficiency
91%
Filter material grade
G 4 (DIN EN 779)
Duty cycle
-
100%
Technical data
-
PF 32000
PFA 30000
AC
DC
Outside dimensions in mm (height x width x installation depth)
202 x 202 x 87
202 x 202 x 81
Bearing type
sleeve bearings
ball bearings
-
vertical
any
any
Fitting position
Construction
housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO
Weight
0.87 kg
0.61 kg
Safety protection
in accordance with DIN 31 001
Color
RAL 7035, RAL 7032 or black
terminal strip
Connections
Power consumption
46
0.26 kg
-
cage clamp
-
PF 32000
Electrical data
Rated voltage +/- 10%
202 x 202 x 34
DC
AC 50 Hz / 60 Hz
230 V
115 V
12 V
24 V
48 V
19 W / 18 W
20 W / 20 W
5W
5W
5W
Airflow data:
cutout:
PF 32000
[in • H2O]
PF 32000 + PFA 30000
.172
Static pressure increase
.147
.123
Installation cutout
177 mm x 177 mm *
.098
.074
PFA 30000
.049
.025
PF 32000
0
0
17
29
40
53
64
76
87
[CFM]
Airflow
Mechanical data:
PF 32000
PF 32000 + PFA 30000
PFA 30000
Filterfans®
Supplementary data
PF 32000 AC
PF 32000 DC
Operating temperature
– 15 °C (- 5 °F) to / bis + 55 °C (+ 131 °F)
Storage temperature
– 20 °C (- 4 °F) to / bis + 70 °C (+ 158 °F)
Max. relative humidity
90%
System of protection
Basic Accessories
Approvals
* Tolerance installation cutout
PFA 30000
NEMA Type 12, IP 55 (EN 60 529), when installed as specified
parts kit filter mat, user manual radiant heater, fan heater, thermostat, hygrostat
UL Recognized
177 + 1/-0 thickness of material to 2 mm
178 + 1/-0 thickness of material > 2 mm < 3 mm
47
Filterfan PF 42500, PF 43000 / Exhaust Filter PFA 40000
l Maintains a UL Tested NEMA Type 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File #E175229,
CE approved for European use
l Patented “Click & Fit” design provides a hardware free installation!
l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire
approved material
Options: EMC, IP55, Light Grey or Black Grills
NEMA Type
Airflow data
Approvals
PF 42500
Mounting
PF 43000
Filter material
PFA 40000
NEMA Type 12 Filtermat
Unimpeded airflow
94 CFM
169 CFM
Capacity free-flow
53 W/K
I88 W/K
-
Airflow in combination
(Filterfan + Exhaust Filter)
67 CFM
(PF 42500 + PFA 40000)
142 CFM
(PF 43000 + PFA 40000)
-
Capacity in combination
(Filterfan + Exhaust Filter)
38 W/K
(PF 43000 + PFA 40000)
69 W/K
(PF 43000 + PFA 40000)
-
112 Pa
-
Max. static pressure (Airflow = 0 m3/h)
49 Pa
Filtration efficiency
91%
Filter material grade
G 4 (DIN EN 779)
Duty cycle
100%
Technical data
-
PF 42500
PF 43000
AC
DC
252 x 252 x 97
Outside dimensions in mm (height x width x installation depth)
Bearing type / Lagerart
Fitting position / Einbaulage
Construction
Weight
DC
252 x 252 x 113
252 x 252 x 97
-
any, horizontal airflow preferred
any
0.92 kg
1.67 kg
1.51 kg
0.46 kg
in accordance with / gemäß DIN 31 001
-
RAL 7035, RAL 7032 or black
Connections / Anschlussart
cage clamp
Electrical data
-
PF 42500
AC 50 Hz / 60 Hz
DC
24 V
230 V
115 V
19 W / 18 W
20 W / 20 W
4,7 W
PF 43000
DC
AC 50 Hz / 60 Hz
Rated voltage +/- 10%
Power consumption
48
252 x 252 x 38
housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO
1.18 kg
Safety protection
Power consumption
PFA 40000
AC
ball bearings
Color
Rated voltage +/- 10%
-
230 V
115 V
24 V
45 W / 39 W
40 W / 40 W
12 W
Airflow data:
cutout:
PF 42500 / PF 43000
PF 42500, PF 43000 + PFA 40000
.344
[in • H2O]
.295
Static pressure increase
.246
Installation cutout
223 mm x 223 mm *
.197
PFA 40000
.147
PF 43000
.098
PF 42500
.049
0
0
24
47
71
110
150
170
195 [CFM]
Airflow
Mechanical data:
PF 42500, PF 43000
PF 42500 PF 43000, PFA 40000
PFA 40000
Filterfans®
Supplementary data
PF 42500
PF 43000
Operating temperature
– 15 °C (- 5 °F) to / bis + 55 °C (+ 131 °F)
Storage temperature
– 20 °C (- 4 °F) to / bis + 70 °C (+ 158 °F)
Max. relative humidity
90%
System of protection
NEMA Type 12, IP 55 (EN 60 529), when installed as specified
Basic Accessories
Approvals
* Tolerance installation cutout
PFA 40000
parts kit filter mat, user manual radiant heater, fan heater, thermostat, hygrostat
UL Recognized
177 + 1/-0 thickness of material to 2 mm
178 + 1/-0 thickness of material > 2 mm < 3 mm
49
Filterfan PF 65000, PF 66000, PF 67000 / Exhaust Filter PFA 60000
l Maintains a UL Tested NEMA Type 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File #E175229,
CE approved for European use
l Patented “Click & Fit” design provides a hardware free installation!
l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire
approved material
Options: EMC, IP55, Light Grey or Black Grills
NEMA Type
Airflow data
Filter material
Unimpeded airflow
Capacity free-flow
Airflow in combination
(Filterfan + Exhaust Filter)
Capacity in combination
(Filterfan + Exhaust Filter)
PF 65000
PF 66000
74 Pa
134 Pa
Filtration efficiency
Filter material grade
Duty cycle
Mounting
PF 67000
NEMA Type 12 Filtermat
462 CFM
IP 54: 213 W/K / 218 W/K
IP 55: 257 W/K / 262 W/K
295 CFM
(PF 66000 + PFA 60000)
I167 W/K
(PF 66000 + PFA 60000)
297 CFM
IP 54: 160 W/K / 160 W/K
IP 55: 168 W/K / 168 W/K
230 CFM
(PF 65000 + PFA 60000)
I127 W/K
(PF 65000 + PFA 60000)
Max. static pressure (Airflow = 0 m3/h)
Approvals
PFA 60000
560 CFM
IP 54: 282 W/K / 292 W/K
IP 55: 308 W/K / 317 W/K
368 CFM
(PF 67000 + PFA 60000)
208 W/K
(PF 67000 + PFA 60000)
Outside dimensions in mm (height x width x installation depth)
-
187 Pa
-
91 %
G 4 (DIN EN 779)
100%
Technical data
-
91 %
G 4 (DIN EN 779)
-
PF 65000
PF 66000
PF 67000
PFA 60000
320 x 320 x 150
320 x 320 x 150
320 x 320 x 150
320 x 320 x 39
Bearing type
Fitting position
ball bearings
-
any, horizontal airflow preferred
any
housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO
Construction
Weight
3.2 kg
3.2 kg
Safety protection
3.7 kg
0.7 kg
in accordance with DIN 31 001
-
RAL 7035, RAL 7032 and black
Color
Connections
cage clamp
-
Electrical data
PF 65000
PF 66000
PF 67000
Rated voltage +/- 10%
230 V
115 V
460 V 3~
230 V
115 V
460 V 3~
230 V
115 V
Power consumption
150 W
90 W
n/a
150 W
160 W
n/a
1232 W
195 W
50
Airflow data:
Cutout:
PF 65000 / PF 66000 / PF 67000
[in • H2O]
PF 65000, PF 66000,
PF 67000 + PFA 60000
.491
.430
Static pressure increase
.369
Installation cutout
291 mm x 291 mm *
PFA 60000
.307
PF 67000
.246
PF 66000
.184
PF 65000
.123
.061
0
0
75
150 230 297 380 453 527 601 [CFM]
Airflow
Mechanical data:
PF 65000, PF 66000, PF 67000
PF 65000, PF 66000, PF 67000 + PFA 60000
PFA 60000
Filterfans®
Supplementary data
PF 65000
PF 66000
Operating temperature
– 15 °C (- 5 °F) to / bis + 55 °C (+ 131 °F)
Storage temperature
– 20 °C (- 4 °F) to / bis + 70 °C (+ 158 °F)
Max. relative humidity
90%
System of protection
NEMA Type 12, IP 55 (EN 60 529), when installed as specified
Basic Accessories
Approvals
* Tolerance installation cutout
PF 67000
parts kit filter mat, user manual radiant heater, fan heater, thermostat, hygrostat
UL Recognized
177 + 1/-0 thickness of material to 2 mm
178 + 1/-0 thickness of material > 2 mm < 3 mm
51
Filterfan PTF 60500, PTF 60700, PTF 61000 / Exhaust Filter PTFA 60000
l Maintains a NEMA 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File #E175229,
CE approved for European use
l Patented “Click & Fit” design provides a hardware free installation!
l Metal Pagoda Cover for rugged environments, easily painted to match
machine color
NEMA Rating
Airflow data
PTF 60500
Approvals
PTF 60700
Filter material
Mounting
Mounting
PTF 61000
PTFA 60000
NEMA 12 Filtermat
Unimpeded airflow
226 CFM
356 CFM
Capacity free-flow
113 W/K
177 W/K
242 W/K
-
Airflow in combination
(Filterfan + Exhaust Filter)
149 CFM
(PTF 60500 + PFA 60000)
227 CFM
(PTF 60700 + PFA 60000)
304 CFM
(PTF 61000 + PFA 60000)
-
Capacity in combination
(Filterfan + Exhaust Filter)
74 W/K
(PTF 60500 + PFA 60000)
113 W/K
(PTF 60700 + PFA 60000)
152 W/K
(PTF 61000 + PFA 60000)
-
71 Pa
88 Pa
158 Pa
Max. static pressure (Airflow = 0 m3/h)
485 CFM
-
Filtration efficiency
81 %
81 %
Filter material grade
Duty cycle
G 3 (DIN EN 779)
100%
G 3 (DIN EN 779)
-
Technical data
Outside dimensions in mm (height x width x installation depth)
PTF 60500
PTF 60700
PTF 61000
125 x 430 x 430 x 50
140 x 470 x 470 x 50
140 x 470 x 470 x 50
Bearing type
Fitting position
Construction
PTFA 60000
-
ball bearings
-
horizontal
any
metal chassis cover powder coaded, snapin plastic housing
Weight
5.5 kg
5.8 kg
6.0 kg
3.1 kg
in accordance with DIN 31 001
Safety protection
-
RAL 7035 (Light Grey)
Color
Connections
terminal strip
Electrical data
-
PTF 61000
PTF 60700
PTF 60500
Rated voltage +/- 10%
230 V
115 V
460 V 3~
230 V
115 V
460 V 3~
230 V
115 V
Power consumption
24 W
24 W
n/a
80 W
90 W
n/a
150 W
170 W
52
Airflow data:
PTF 60500
PTF 60700
PTF 61000
.174
.216
.39
PFA 60000
PTF 60500
Airflow
149
226
PFA 60000
PTF 60700
Airflow
227
356 [CFM]
Static pressure increase
[in • H2O]
Static pressure increase
[in • H2O]
Static pressure increase
[in • H2O]
PFA 60000
PTF 61000
Airflow
304
485 [CFM]
Mechanical data:
Filterfans®
53
3rd Generation Filterfans®
l Maintains a NEMA 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File
#E175229, CE approved for European use
l Patented “Click & Fit” design provides a hardware free
installation!
l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO
fire approved material
Options: Light Grey, Beige or Black Grills
Air Flow data:
PF 1000
PF 2000
PF 2500
NEMA Rating
Approvals
PF 3000
PF 5000
Mounting
PF 6000
Mounting
PF 7000
Free flow air delivery (CFM2)
16
38
89
169
324
410
506
Air delivery w/ exhaust (CFM3)
10
28
62
142
249
295
368
Max. static presure (PA)
29
69
57
89
205
225
174
Filter density (g/m2)
150
Filtration efficiency
73
Noise level
Ambient temperature ºF (Max/Min)
39
49
53
55
69
71
76
140/14
122/14
122/14
122/14
122/14
122/14
122/14
PF 6000
PF 7000
Max. relative humidity (rH)
90%
Duty cycle
100%
Electrical data:
PF 1000
PF 2000
Rated voltage
PF 2500
PF 3000
PF 5000
115V / 230V / 24vdc
115V / 230V
50/60Hz (Fan CFM based on 115V 60Hz performance)
Rated frequency
Power consumption
12 Watts
19 Watts
18 Watts
43 Watts
63 Watts
122 Watts
167 Watts
Current draw (Amps)
0.15/0.08/0.1 A
0.25/0.13/0.24 A
0.25/0.13/0.24 A
0.5/0.25/0.5 A
0.7/0.35 A
1.7/0.8 A
1.5/0.7 A
PF 5000
PF 6000
PF 7000
Terminal strip
Connection Method
Supplementary data:
Weight (without packaging)
PF 1000
PF 2000
PF 2500
PF 3000
1.21 lbs
1.62 lbs
3.8 lbs
4.0 lbs
6.6 lbs
7.7 lbs
9.0 lbs
Outside dimensions
105 x 105 x 52
150 x 150 x 72
250 x 250 x 111
250 x 250 x 121
325 x 325 x 157
325 x 325 x 158
325 x 325 x 125
Bearing type
sleeve bearings
ball bearings
sprayed thermoplastic (ABS-FR), self-extinguishing UL 94 VO
Construction material
RAL 9011 (black) or RAL 7032 (beige)
Standard Colors
Climatic data
NEMA Rating / Ingress protection
max. ambient temperature +131°F (+55°C)
min. ambient temperature +46°F (+8°C)
NEMA 1/ IP 43
NEMA 12 / IP 54
Consult Factory for More Special Style Filterfans Including:
Reverse Flow - PF xxxx “A” Models
54
Low EMC Versions (PF 2000 - PF 6000)
IP 55 Versions (PF 2000 - PF 7000)
Traditional Metal Box Fans
Filterfans®
55
3rd Generation Exhaust Filters
l Maintains a NEMA 12 seal against enclosure
l UL Recognized to UL 508a, category NITW2/8, UL File
#E175229, CE approved for European use
l Patented “Click & Fit” design provides a hardware free
installation!
l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO
fire approved material
Options: Light Grey, Beige or Black Grills
NEMA Rating
Technical data:
PFA 1000
PFA 2000
PFA 25/3000
Filter density (g/m2)
150
150
150
150
Filtration efficiency
73%
73%
73%
73%
105 x 105 x 10
150 x 150 x 27
250 x 250 x 30
325 x 325 x 30
Outside Dimensions (mm)
Construction Material
sprayed thermoplastic (ABS-FR), self-extinguishing UL 94 VO
Standard Colors
NEMA Rating
56
RAL 9011 (black) or RAL 7032 (beige)
NEMA 1/ IP 43
NEMA 12 / IP 54
PFA 5/6000
Approvals
Mounting
Mounting
NEMA 3R Filterfan® Rainhoods
l NEMA 3R / Outdoor Rainhoods for 3rd and 4th
Generation Filterfans®
Tack weld flap
193.0 2 8
in (2) plac2000,
es,
Fits PF/PFA
25/3000, 5/6/7000 3rd Generation
Units
7 . 60
both sides
1 7 4 .0 0 0
5
Fits PF/PFA 20000, 40000, 60000 4th Generation6.8Units
2 7 . 2 30
304 Stainless Steel or Powder1.07Coated Steel Options
193.0 2 8
Due to dust and7.60vapor, a true NEMA 4 rating should be allowed
9. 5 1 4
174.000
1 5 . 5 25
.375
6 .8 5
for open loop systems
. 61 1
l
l
62 . 31 8
2.45
Ref.
l
Tack weld flap
in (2) places,
both sides
l
55 °
62 . 31 8
2.45
Ref.
2 7 . 2 30
1. 0 7
1 2 4 . 9 68
4 .9 2
FILTER FAN CUT O U T
FILTER FAN CUT O U T
2 6 8. 1 80
1 0. 5 6
12 0 . 7 2 0
4 .7 5
10 0 . 5 84
3.9 6
NEMA Rating
Mounting
12 0 . 7 2 0
4 .7 5
55
.000.5084
10
2.3
1.796
3 4 . 03 0
1. 3 4
1 9 .0 5 0
.75
124.968
Ta4
ck.9w2eld flap
in (2) places,
both sides
98.917
3.89
R ef .
193.0 2 8
7 . 60
98.917
3.89
R ef .
2 7 . 2 30
1. 0 7
137.000
5.39
9.509
.374
15.525
.611
15.525
.611
173.228
6.82
.375"
hex hole
X(7)
55°
1 2 0. 72 0
4 . 75
F ILTER FAN C UT O U T
373.180
14.69
FILTER FAN CUT O U T
223.012
8.78
173.228
6.82
314.468
12.38
.375"
R ef .
hex hole
2 6 8. 1 80
1 0. 5 6
2 30 . 46 0
9 . 07
Ref.
9.509
.374
293.018
11.54
137.000
5.39
27.230
1.07
55 °
1 2 4 . 9 68
4 .9 2
137.000
5.39
Filterfans®
62 . 31 8
2.45
Ref.
293.018
11.54
137.000
5.39
27.230
1.07
55°
Tack weld flap
9.5i1n4(2) places,
.37b5oth side1s5.525
. 61 1
1 7 4 .0 0 0
6 .8 5
1 9 .0 5 0
.75
1 2 4 .9 6 8
4 .9 2
11 . 2 1 5
.4 4
.375" hex hole
X(6)
5 5.0 00
2.1 7
11 . 2 1 5
.4 4
.375" hex hole
X(6)
3 4 . 03 0
1. 3 4
Mechanical data: PF-RH-2000 & PF-RH-25/3000
Tack weld flap
in (2) places,
both sides
1 2 0. 72 0
4 . 75
1 2 0. 72 0
4 . 75
1 2 4 . 9 68
4 .9 2
2 30 . 46 0
9 . 07
Ref.
X(7)
F ILTER FAN C UT O U T
223.012
8.78
373.180
14.69
314.468
12.38
R ef .
10 0 . 5 8 4
3.9 6
78.969
3.109
5 5.0 00
2.1 7
3 4 . 03 0
1. 3 4
11 . 2 1 5
.4 4
Mechanical data: PF-RH-5/6/7000
19.050
.75
124.968
4 .9 2
137.000
5.39
137.000
5.39
173.228
6.82
11.199
.44
84.980
3.35
78.969
3.109
35.003
1.38
9.509
.374
35.003
1.38
19.050
.75
223.012
8.78
Tack weld flap
in (2) places,
both sides
15.525
.611
27.230
1.07
368.086
14.49
174.520
6.87
55°
Tack weld flap
in173(.2228) places,
6.82
bo
th sides
129.461
5.10
Ref. 174.520
.375"
hex hole
X(7)
368.086
14.49
174.520
6.87
6.87
27.230
1.07
9.523
.375
F ILTER FAN C UT O U T
373.180
14.69
129.461
5.10
R ef .
223.012
8.78
314.468
12.38
R ef .
19.050
.75
223.012
8.78
11.199
.44
84.980
3.35
293.018
11.54
Tack weld flap
in (2) places,
both sides
98.917
3.89
R ef .
173.228
6.82
12 0 . 7 2 0
4 .7 5
.375" hex hole
X(6)
174.520
6.87
9.523
.375
15.525
.611
15.525
.611
27.230
1.07
148.790
5.86
55°
173.228
6.82
148.790
5.86
55°
78.969
3.109
473.180
18.63
11.199
.44
84.980
3.35
35.003
1.38
19.050
.75
223.012
8.78
473.180
18.63
396.949
15.63
R ef .
Tack weld flap
in (2) places,
both sides
129.461
5.10
R ef .
396.949
291.084
15.63
11.46
R ef .
FI L TER F AN CUT OU T
174.520
6.87
9.523
.375
148.790
5.86
148.790
5.86
148.790
5.86
110.896
4.37
55°
110.000
4.33
396.949
15.63
R ef .
38.501
1.52
.375" hex hole
X(9)
110.000
4.33
FI L TER F AN CUT OU T
148.790
5.86
110.896
4.37
148.790
5.86
291.084
11.46
FI L TER F AN CUT OU T
15.525
.611
27.230
1.07
473.180
18.63
291.084
11.46
368.086
14.49
174.520
6.87
38.501
1.52
148.790
5.86
291.084
11.46
.375" hex hole
X(9)
11.285
291.084
.44
19.050
.75
11.285
.44
19.050
.75
11.46
57
148.790
5.86
110.896
4.37
110.000
4.33
11.285
.44
.375" hex hole
X(9)
38.501
1.52
291.084
11.46
19.050
.75
1 5 . 5 25
. 61 1
2 6 8. 1 80
1 0. 5 6
2 30 . 46 0
9 . 07
Ref.
55 °
9. 5 1 4
.375
Panel Fans
Mechanical data: PFP-BK200 shown (bracket sold separate)
Air Flow data:
Free flow air delivery
Ambient temperature ºF (Max/Min)
PFP 100
PFP 200
PFP 500
106
230
550
122/14
122/14
122/14
Max. relative humidity (rH)
90%
Duty cycle
100%
Electrical data:
PFP 100
PFP 200
PFP 500
Rated voltage
115V / 230V
115V / 230V
115V / 230V
50/60Hz (Fan CFM based on 115V 60Hz performance)
Rated frequency
Power consumption
Current draw
18 Watts
24 Watts
60 Watts
0.18A / 0.09A
0.29A / 0.15A
0.5A / 0.25A
Connection Method
Power Cable
Supplementary data:
PFP 100
PFP 200
Weight (without packaging)
1.2 lbs
2.0 lbs
4.4 lbs
Bracket model No.
PFP-BK 100
PFP-BK 200
PFP-BK 500
Finger guard model No.
PFP-FG 100
PFP-FG 200
PFP-FG 500
Standard supply includes
58
1 finger guard, power cable and mounting hardware (no bracket supplied)
PFP 500
Download