NEMA Type 12 Filterfans® Features/Benefits: Patented four-corner “click & fit” system – Enhancing our traditional “click & fit” system, we created an easier to assemble and tighter seal against multiple gauge enclosure sizes. Special Fluted Filter – This special Type 12 filter increases time between maintenance by three times and allows for greater CFM in dirty environments. True hardware-free mounting – Our Filterfans do not require any screws to create the pressure on our gasket material to maintain a Type 12 seal against the enclosure. Removing these screws reduce the labor time to mount the Filterfans by greater than 200%. Filterfans® Easy to change filter – The patented hinge system allows for a quick, handsfree change. This reduces the number of lost and damaged grills when they items are placed on floors and carried away from the machine. UL tested NEMA Type 12 rating - Our Filterfans are tested by UL to UL 50 Type 12 and NITW2 categories allowing Integrators to maintain the enclosure ratings of the enclosure while maintaining the high CFM ratings of our original Filterfans. www.filterfanusa.com Options: Table of Contents • Low EMC Option – If low EMI emissions are a concern for your application, please contact Pfannenberg for our EMC version of these Filterfans. • IP 55, Outdoor/Washdown Option – By using a UV resistant grill, Pfannenbergís new Filterfans meet the European IP55 rating for enclosures. • Rainhood Option – If more security is needed in outdoor or washdown environments then consider our PF-RH-XXXX series. • Special Colors/Voltages – Many of our Filterfans are available is special colors and voltages. Please consult with the factory. NEW FilterFan Introduction New PF New PTF 3rd Gen PF PF 11000/22000, PFA 1/20000 PF 32000, PFA 30000 PF 42500/43000, PFA 40000 PF 65/66/67000, PFA 60000 PTF 60500/60700/61000 PF Series - 3rd Generation PFA Series - 3rd Generation PF-RH Rainhoods Panel Fans 27 44-45 46-47 48-49 50-51 52-53 54-55 56 57 58 43 Filterfan PF 11000-22000 / Exhaust Filter PFA 10000-20000 l Maintains a UL Tested NEMA Type 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: EMC, IP55, Light Grey or Black Grills NEMA Type Airflow data PF 11000 Filter material Type 12 filter mat Approvals Mounting PFA 10000 PFA20000 PF 22000 Type 12 filter mat Type 12 filter mat Unimpeded airflow 17 CFM 38 CFM - Capacity free-flow 10 W/K 21 W/K - Airflow in combination (Filterfan + Exhaust Filter) 11 CFM (PF 22000 + PFA 20000) 28 CFM (PF 22000 + PFA 20000) - Capacity in combination (Filterfan + Exhaust Filter) 6 W/K (PF 22000 + PFA 20000) 15 W/K (PF 22000 + PFA 20000) - 38 Pa 57 Pa - Max. static pressure (Airflow = 0 m3/h) Filtration efficiency 88% 91% 88/91% Filter material grade G 3 (DIN EN 779) G 4 (DIN EN 779) G3/ G4 (DIN EN 779) 100% 100% Duty cycle Technical data PF 11000 AC PF 22000 DC AC PFA 10000/ PFA 20000 DC Outside dimensions in mm (height x width x installation depth) 109 x 109 x 62 109 x 109 x 49 145 x 145 x 70 145 x 145 x 64 109 x 109 x 26/ 145 x 145 x 26 Bearing type sleeve bearings ball bearings sleeve bearings ball bearings - Fitting position vertical any vertical any - Construction Weight 0.55 kg housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO 0.16 kg 0.7 kg 0.44 kg Safety protection in accordance with DIN 31 001 Color 0.06 kg / 0.12 kg - RAL 7035, RAL 7032 or black, other colors on request Connection terminal strip System of protection 2 wires, 310 mm long - NEMA Type 12, IP 55 (EN 60 529), when installed as specified AC PF 11000 AC DC AC PF 22000 AC DC Rated voltage 230 V 115 V 24 V 230 V 115 V 24 V Power consumption 11 W 11 W 2W 18 W 20 W 5W Electrical data 44 Airflow data: PF 11000 PF 22000 [in • H2O] .098 .086 [in • H2O] .172 .147 .061 Static pressure increase Static pressure increase .074 .049 .037 PFA 10000 .025 PF 11000 .012 .123 .098 PFA 20000 .074 .049 PF 22000 .025 0 0 0 3 6 9 12 15 18 [CFM] Airflow Airflow Mechanical data: PF 11000 PF 11000 + PFA 10000 PFA 10000 Cutout Filterfans® Installation cutout 92 mm x 92 mm* standard punch size Mechanical data: PF 22000 PF 22000 + PFA 20000 PFA 20000 Cutout Installation cutout 125 mm x 125 mm * 45 Filterfan PF 32000 / Exhaust Filter PFA 30000 l Maintains a UL Tested NEMA Type 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: EMC, IP55, Light Grey or Black Grills NEMA Type Approvals Airflow data PF 32000 Filter material NEMA Type 12 filter mat Mounting PFA 30000 Unimpeded airflow 65 CFM Capacity free-flow 37 W/K - Airflow in combination (Filterfan + Exhaust Filter) 38 CFM (PF 32000 + PFA 30000) - Capacity in combination (Filterfan + Exhaust Filter) 21 W/K (PF 32000 + PFA 30000) - Max. static pressure (Airflow = 0 m3/h) 61 Pa - Filtration efficiency 91% Filter material grade G 4 (DIN EN 779) Duty cycle - 100% Technical data - PF 32000 PFA 30000 AC DC Outside dimensions in mm (height x width x installation depth) 202 x 202 x 87 202 x 202 x 81 Bearing type sleeve bearings ball bearings - vertical any any Fitting position Construction housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO Weight 0.87 kg 0.61 kg Safety protection in accordance with DIN 31 001 Color RAL 7035, RAL 7032 or black terminal strip Connections Power consumption 46 0.26 kg - cage clamp - PF 32000 Electrical data Rated voltage +/- 10% 202 x 202 x 34 DC AC 50 Hz / 60 Hz 230 V 115 V 12 V 24 V 48 V 19 W / 18 W 20 W / 20 W 5W 5W 5W Airflow data: cutout: PF 32000 [in • H2O] PF 32000 + PFA 30000 .172 Static pressure increase .147 .123 Installation cutout 177 mm x 177 mm * .098 .074 PFA 30000 .049 .025 PF 32000 0 0 17 29 40 53 64 76 87 [CFM] Airflow Mechanical data: PF 32000 PF 32000 + PFA 30000 PFA 30000 Filterfans® Supplementary data PF 32000 AC PF 32000 DC Operating temperature – 15 °C (- 5 °F) to / bis + 55 °C (+ 131 °F) Storage temperature – 20 °C (- 4 °F) to / bis + 70 °C (+ 158 °F) Max. relative humidity 90% System of protection Basic Accessories Approvals * Tolerance installation cutout PFA 30000 NEMA Type 12, IP 55 (EN 60 529), when installed as specified parts kit filter mat, user manual radiant heater, fan heater, thermostat, hygrostat UL Recognized 177 + 1/-0 thickness of material to 2 mm 178 + 1/-0 thickness of material > 2 mm < 3 mm 47 Filterfan PF 42500, PF 43000 / Exhaust Filter PFA 40000 l Maintains a UL Tested NEMA Type 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: EMC, IP55, Light Grey or Black Grills NEMA Type Airflow data Approvals PF 42500 Mounting PF 43000 Filter material PFA 40000 NEMA Type 12 Filtermat Unimpeded airflow 94 CFM 169 CFM Capacity free-flow 53 W/K I88 W/K - Airflow in combination (Filterfan + Exhaust Filter) 67 CFM (PF 42500 + PFA 40000) 142 CFM (PF 43000 + PFA 40000) - Capacity in combination (Filterfan + Exhaust Filter) 38 W/K (PF 43000 + PFA 40000) 69 W/K (PF 43000 + PFA 40000) - 112 Pa - Max. static pressure (Airflow = 0 m3/h) 49 Pa Filtration efficiency 91% Filter material grade G 4 (DIN EN 779) Duty cycle 100% Technical data - PF 42500 PF 43000 AC DC 252 x 252 x 97 Outside dimensions in mm (height x width x installation depth) Bearing type / Lagerart Fitting position / Einbaulage Construction Weight DC 252 x 252 x 113 252 x 252 x 97 - any, horizontal airflow preferred any 0.92 kg 1.67 kg 1.51 kg 0.46 kg in accordance with / gemäß DIN 31 001 - RAL 7035, RAL 7032 or black Connections / Anschlussart cage clamp Electrical data - PF 42500 AC 50 Hz / 60 Hz DC 24 V 230 V 115 V 19 W / 18 W 20 W / 20 W 4,7 W PF 43000 DC AC 50 Hz / 60 Hz Rated voltage +/- 10% Power consumption 48 252 x 252 x 38 housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO 1.18 kg Safety protection Power consumption PFA 40000 AC ball bearings Color Rated voltage +/- 10% - 230 V 115 V 24 V 45 W / 39 W 40 W / 40 W 12 W Airflow data: cutout: PF 42500 / PF 43000 PF 42500, PF 43000 + PFA 40000 .344 [in • H2O] .295 Static pressure increase .246 Installation cutout 223 mm x 223 mm * .197 PFA 40000 .147 PF 43000 .098 PF 42500 .049 0 0 24 47 71 110 150 170 195 [CFM] Airflow Mechanical data: PF 42500, PF 43000 PF 42500 PF 43000, PFA 40000 PFA 40000 Filterfans® Supplementary data PF 42500 PF 43000 Operating temperature – 15 °C (- 5 °F) to / bis + 55 °C (+ 131 °F) Storage temperature – 20 °C (- 4 °F) to / bis + 70 °C (+ 158 °F) Max. relative humidity 90% System of protection NEMA Type 12, IP 55 (EN 60 529), when installed as specified Basic Accessories Approvals * Tolerance installation cutout PFA 40000 parts kit filter mat, user manual radiant heater, fan heater, thermostat, hygrostat UL Recognized 177 + 1/-0 thickness of material to 2 mm 178 + 1/-0 thickness of material > 2 mm < 3 mm 49 Filterfan PF 65000, PF 66000, PF 67000 / Exhaust Filter PFA 60000 l Maintains a UL Tested NEMA Type 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: EMC, IP55, Light Grey or Black Grills NEMA Type Airflow data Filter material Unimpeded airflow Capacity free-flow Airflow in combination (Filterfan + Exhaust Filter) Capacity in combination (Filterfan + Exhaust Filter) PF 65000 PF 66000 74 Pa 134 Pa Filtration efficiency Filter material grade Duty cycle Mounting PF 67000 NEMA Type 12 Filtermat 462 CFM IP 54: 213 W/K / 218 W/K IP 55: 257 W/K / 262 W/K 295 CFM (PF 66000 + PFA 60000) I167 W/K (PF 66000 + PFA 60000) 297 CFM IP 54: 160 W/K / 160 W/K IP 55: 168 W/K / 168 W/K 230 CFM (PF 65000 + PFA 60000) I127 W/K (PF 65000 + PFA 60000) Max. static pressure (Airflow = 0 m3/h) Approvals PFA 60000 560 CFM IP 54: 282 W/K / 292 W/K IP 55: 308 W/K / 317 W/K 368 CFM (PF 67000 + PFA 60000) 208 W/K (PF 67000 + PFA 60000) Outside dimensions in mm (height x width x installation depth) - 187 Pa - 91 % G 4 (DIN EN 779) 100% Technical data - 91 % G 4 (DIN EN 779) - PF 65000 PF 66000 PF 67000 PFA 60000 320 x 320 x 150 320 x 320 x 150 320 x 320 x 150 320 x 320 x 39 Bearing type Fitting position ball bearings - any, horizontal airflow preferred any housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO Construction Weight 3.2 kg 3.2 kg Safety protection 3.7 kg 0.7 kg in accordance with DIN 31 001 - RAL 7035, RAL 7032 and black Color Connections cage clamp - Electrical data PF 65000 PF 66000 PF 67000 Rated voltage +/- 10% 230 V 115 V 460 V 3~ 230 V 115 V 460 V 3~ 230 V 115 V Power consumption 150 W 90 W n/a 150 W 160 W n/a 1232 W 195 W 50 Airflow data: Cutout: PF 65000 / PF 66000 / PF 67000 [in • H2O] PF 65000, PF 66000, PF 67000 + PFA 60000 .491 .430 Static pressure increase .369 Installation cutout 291 mm x 291 mm * PFA 60000 .307 PF 67000 .246 PF 66000 .184 PF 65000 .123 .061 0 0 75 150 230 297 380 453 527 601 [CFM] Airflow Mechanical data: PF 65000, PF 66000, PF 67000 PF 65000, PF 66000, PF 67000 + PFA 60000 PFA 60000 Filterfans® Supplementary data PF 65000 PF 66000 Operating temperature – 15 °C (- 5 °F) to / bis + 55 °C (+ 131 °F) Storage temperature – 20 °C (- 4 °F) to / bis + 70 °C (+ 158 °F) Max. relative humidity 90% System of protection NEMA Type 12, IP 55 (EN 60 529), when installed as specified Basic Accessories Approvals * Tolerance installation cutout PF 67000 parts kit filter mat, user manual radiant heater, fan heater, thermostat, hygrostat UL Recognized 177 + 1/-0 thickness of material to 2 mm 178 + 1/-0 thickness of material > 2 mm < 3 mm 51 Filterfan PTF 60500, PTF 60700, PTF 61000 / Exhaust Filter PTFA 60000 l Maintains a NEMA 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Metal Pagoda Cover for rugged environments, easily painted to match machine color NEMA Rating Airflow data PTF 60500 Approvals PTF 60700 Filter material Mounting Mounting PTF 61000 PTFA 60000 NEMA 12 Filtermat Unimpeded airflow 226 CFM 356 CFM Capacity free-flow 113 W/K 177 W/K 242 W/K - Airflow in combination (Filterfan + Exhaust Filter) 149 CFM (PTF 60500 + PFA 60000) 227 CFM (PTF 60700 + PFA 60000) 304 CFM (PTF 61000 + PFA 60000) - Capacity in combination (Filterfan + Exhaust Filter) 74 W/K (PTF 60500 + PFA 60000) 113 W/K (PTF 60700 + PFA 60000) 152 W/K (PTF 61000 + PFA 60000) - 71 Pa 88 Pa 158 Pa Max. static pressure (Airflow = 0 m3/h) 485 CFM - Filtration efficiency 81 % 81 % Filter material grade Duty cycle G 3 (DIN EN 779) 100% G 3 (DIN EN 779) - Technical data Outside dimensions in mm (height x width x installation depth) PTF 60500 PTF 60700 PTF 61000 125 x 430 x 430 x 50 140 x 470 x 470 x 50 140 x 470 x 470 x 50 Bearing type Fitting position Construction PTFA 60000 - ball bearings - horizontal any metal chassis cover powder coaded, snapin plastic housing Weight 5.5 kg 5.8 kg 6.0 kg 3.1 kg in accordance with DIN 31 001 Safety protection - RAL 7035 (Light Grey) Color Connections terminal strip Electrical data - PTF 61000 PTF 60700 PTF 60500 Rated voltage +/- 10% 230 V 115 V 460 V 3~ 230 V 115 V 460 V 3~ 230 V 115 V Power consumption 24 W 24 W n/a 80 W 90 W n/a 150 W 170 W 52 Airflow data: PTF 60500 PTF 60700 PTF 61000 .174 .216 .39 PFA 60000 PTF 60500 Airflow 149 226 PFA 60000 PTF 60700 Airflow 227 356 [CFM] Static pressure increase [in • H2O] Static pressure increase [in • H2O] Static pressure increase [in • H2O] PFA 60000 PTF 61000 Airflow 304 485 [CFM] Mechanical data: Filterfans® 53 3rd Generation Filterfans® l Maintains a NEMA 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: Light Grey, Beige or Black Grills Air Flow data: PF 1000 PF 2000 PF 2500 NEMA Rating Approvals PF 3000 PF 5000 Mounting PF 6000 Mounting PF 7000 Free flow air delivery (CFM2) 16 38 89 169 324 410 506 Air delivery w/ exhaust (CFM3) 10 28 62 142 249 295 368 Max. static presure (PA) 29 69 57 89 205 225 174 Filter density (g/m2) 150 Filtration efficiency 73 Noise level Ambient temperature ºF (Max/Min) 39 49 53 55 69 71 76 140/14 122/14 122/14 122/14 122/14 122/14 122/14 PF 6000 PF 7000 Max. relative humidity (rH) 90% Duty cycle 100% Electrical data: PF 1000 PF 2000 Rated voltage PF 2500 PF 3000 PF 5000 115V / 230V / 24vdc 115V / 230V 50/60Hz (Fan CFM based on 115V 60Hz performance) Rated frequency Power consumption 12 Watts 19 Watts 18 Watts 43 Watts 63 Watts 122 Watts 167 Watts Current draw (Amps) 0.15/0.08/0.1 A 0.25/0.13/0.24 A 0.25/0.13/0.24 A 0.5/0.25/0.5 A 0.7/0.35 A 1.7/0.8 A 1.5/0.7 A PF 5000 PF 6000 PF 7000 Terminal strip Connection Method Supplementary data: Weight (without packaging) PF 1000 PF 2000 PF 2500 PF 3000 1.21 lbs 1.62 lbs 3.8 lbs 4.0 lbs 6.6 lbs 7.7 lbs 9.0 lbs Outside dimensions 105 x 105 x 52 150 x 150 x 72 250 x 250 x 111 250 x 250 x 121 325 x 325 x 157 325 x 325 x 158 325 x 325 x 125 Bearing type sleeve bearings ball bearings sprayed thermoplastic (ABS-FR), self-extinguishing UL 94 VO Construction material RAL 9011 (black) or RAL 7032 (beige) Standard Colors Climatic data NEMA Rating / Ingress protection max. ambient temperature +131°F (+55°C) min. ambient temperature +46°F (+8°C) NEMA 1/ IP 43 NEMA 12 / IP 54 Consult Factory for More Special Style Filterfans Including: Reverse Flow - PF xxxx “A” Models 54 Low EMC Versions (PF 2000 - PF 6000) IP 55 Versions (PF 2000 - PF 7000) Traditional Metal Box Fans Filterfans® 55 3rd Generation Exhaust Filters l Maintains a NEMA 12 seal against enclosure l UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use l Patented “Click & Fit” design provides a hardware free installation! l Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: Light Grey, Beige or Black Grills NEMA Rating Technical data: PFA 1000 PFA 2000 PFA 25/3000 Filter density (g/m2) 150 150 150 150 Filtration efficiency 73% 73% 73% 73% 105 x 105 x 10 150 x 150 x 27 250 x 250 x 30 325 x 325 x 30 Outside Dimensions (mm) Construction Material sprayed thermoplastic (ABS-FR), self-extinguishing UL 94 VO Standard Colors NEMA Rating 56 RAL 9011 (black) or RAL 7032 (beige) NEMA 1/ IP 43 NEMA 12 / IP 54 PFA 5/6000 Approvals Mounting Mounting NEMA 3R Filterfan® Rainhoods l NEMA 3R / Outdoor Rainhoods for 3rd and 4th Generation Filterfans® Tack weld flap 193.0 2 8 in (2) plac2000, es, Fits PF/PFA 25/3000, 5/6/7000 3rd Generation Units 7 . 60 both sides 1 7 4 .0 0 0 5 Fits PF/PFA 20000, 40000, 60000 4th Generation6.8Units 2 7 . 2 30 304 Stainless Steel or Powder1.07Coated Steel Options 193.0 2 8 Due to dust and7.60vapor, a true NEMA 4 rating should be allowed 9. 5 1 4 174.000 1 5 . 5 25 .375 6 .8 5 for open loop systems . 61 1 l l 62 . 31 8 2.45 Ref. l Tack weld flap in (2) places, both sides l 55 ° 62 . 31 8 2.45 Ref. 2 7 . 2 30 1. 0 7 1 2 4 . 9 68 4 .9 2 FILTER FAN CUT O U T FILTER FAN CUT O U T 2 6 8. 1 80 1 0. 5 6 12 0 . 7 2 0 4 .7 5 10 0 . 5 84 3.9 6 NEMA Rating Mounting 12 0 . 7 2 0 4 .7 5 55 .000.5084 10 2.3 1.796 3 4 . 03 0 1. 3 4 1 9 .0 5 0 .75 124.968 Ta4 ck.9w2eld flap in (2) places, both sides 98.917 3.89 R ef . 193.0 2 8 7 . 60 98.917 3.89 R ef . 2 7 . 2 30 1. 0 7 137.000 5.39 9.509 .374 15.525 .611 15.525 .611 173.228 6.82 .375" hex hole X(7) 55° 1 2 0. 72 0 4 . 75 F ILTER FAN C UT O U T 373.180 14.69 FILTER FAN CUT O U T 223.012 8.78 173.228 6.82 314.468 12.38 .375" R ef . hex hole 2 6 8. 1 80 1 0. 5 6 2 30 . 46 0 9 . 07 Ref. 9.509 .374 293.018 11.54 137.000 5.39 27.230 1.07 55 ° 1 2 4 . 9 68 4 .9 2 137.000 5.39 Filterfans® 62 . 31 8 2.45 Ref. 293.018 11.54 137.000 5.39 27.230 1.07 55° Tack weld flap 9.5i1n4(2) places, .37b5oth side1s5.525 . 61 1 1 7 4 .0 0 0 6 .8 5 1 9 .0 5 0 .75 1 2 4 .9 6 8 4 .9 2 11 . 2 1 5 .4 4 .375" hex hole X(6) 5 5.0 00 2.1 7 11 . 2 1 5 .4 4 .375" hex hole X(6) 3 4 . 03 0 1. 3 4 Mechanical data: PF-RH-2000 & PF-RH-25/3000 Tack weld flap in (2) places, both sides 1 2 0. 72 0 4 . 75 1 2 0. 72 0 4 . 75 1 2 4 . 9 68 4 .9 2 2 30 . 46 0 9 . 07 Ref. X(7) F ILTER FAN C UT O U T 223.012 8.78 373.180 14.69 314.468 12.38 R ef . 10 0 . 5 8 4 3.9 6 78.969 3.109 5 5.0 00 2.1 7 3 4 . 03 0 1. 3 4 11 . 2 1 5 .4 4 Mechanical data: PF-RH-5/6/7000 19.050 .75 124.968 4 .9 2 137.000 5.39 137.000 5.39 173.228 6.82 11.199 .44 84.980 3.35 78.969 3.109 35.003 1.38 9.509 .374 35.003 1.38 19.050 .75 223.012 8.78 Tack weld flap in (2) places, both sides 15.525 .611 27.230 1.07 368.086 14.49 174.520 6.87 55° Tack weld flap in173(.2228) places, 6.82 bo th sides 129.461 5.10 Ref. 174.520 .375" hex hole X(7) 368.086 14.49 174.520 6.87 6.87 27.230 1.07 9.523 .375 F ILTER FAN C UT O U T 373.180 14.69 129.461 5.10 R ef . 223.012 8.78 314.468 12.38 R ef . 19.050 .75 223.012 8.78 11.199 .44 84.980 3.35 293.018 11.54 Tack weld flap in (2) places, both sides 98.917 3.89 R ef . 173.228 6.82 12 0 . 7 2 0 4 .7 5 .375" hex hole X(6) 174.520 6.87 9.523 .375 15.525 .611 15.525 .611 27.230 1.07 148.790 5.86 55° 173.228 6.82 148.790 5.86 55° 78.969 3.109 473.180 18.63 11.199 .44 84.980 3.35 35.003 1.38 19.050 .75 223.012 8.78 473.180 18.63 396.949 15.63 R ef . Tack weld flap in (2) places, both sides 129.461 5.10 R ef . 396.949 291.084 15.63 11.46 R ef . FI L TER F AN CUT OU T 174.520 6.87 9.523 .375 148.790 5.86 148.790 5.86 148.790 5.86 110.896 4.37 55° 110.000 4.33 396.949 15.63 R ef . 38.501 1.52 .375" hex hole X(9) 110.000 4.33 FI L TER F AN CUT OU T 148.790 5.86 110.896 4.37 148.790 5.86 291.084 11.46 FI L TER F AN CUT OU T 15.525 .611 27.230 1.07 473.180 18.63 291.084 11.46 368.086 14.49 174.520 6.87 38.501 1.52 148.790 5.86 291.084 11.46 .375" hex hole X(9) 11.285 291.084 .44 19.050 .75 11.285 .44 19.050 .75 11.46 57 148.790 5.86 110.896 4.37 110.000 4.33 11.285 .44 .375" hex hole X(9) 38.501 1.52 291.084 11.46 19.050 .75 1 5 . 5 25 . 61 1 2 6 8. 1 80 1 0. 5 6 2 30 . 46 0 9 . 07 Ref. 55 ° 9. 5 1 4 .375 Panel Fans Mechanical data: PFP-BK200 shown (bracket sold separate) Air Flow data: Free flow air delivery Ambient temperature ºF (Max/Min) PFP 100 PFP 200 PFP 500 106 230 550 122/14 122/14 122/14 Max. relative humidity (rH) 90% Duty cycle 100% Electrical data: PFP 100 PFP 200 PFP 500 Rated voltage 115V / 230V 115V / 230V 115V / 230V 50/60Hz (Fan CFM based on 115V 60Hz performance) Rated frequency Power consumption Current draw 18 Watts 24 Watts 60 Watts 0.18A / 0.09A 0.29A / 0.15A 0.5A / 0.25A Connection Method Power Cable Supplementary data: PFP 100 PFP 200 Weight (without packaging) 1.2 lbs 2.0 lbs 4.4 lbs Bracket model No. PFP-BK 100 PFP-BK 200 PFP-BK 500 Finger guard model No. PFP-FG 100 PFP-FG 200 PFP-FG 500 Standard supply includes 58 1 finger guard, power cable and mounting hardware (no bracket supplied) PFP 500