Metalux Ovation™ Data Sheet

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The Ovation Series is a complete family of recessed direct/indirect
luminaires featuring pleasant modern architectural styling, computerdesigned optics and the latest energy efficient lamp and ballast technology.The luminaire combines a matte white indirect reflector and a
perforated direct lamp shield to provide optimum brightness control.
All components are located above the ceiling plane for a clean architectural appearance in the finished space. Carefully balanced design elements combine to provide an efficient and exciting alternative to traditional general lighting. Ovation is an excellent choice for a wide variety
of commercial applications.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A…Construction
C…Ballast Access
E…Ref lector s
Nominal 6" deep housing is die formed
of code gauge, prime cold rolled steel.
Heavy gauge end plates are securely
attached with screws for strength and
rigidity and the elimination of gaps. Four
auxiliary fixture end suspension points
are provided. KOs for continuous row
wiring. Large access plate for supply connection.
Ballast can be removed from
below without tools or from
above using the unique ballast
mounting/access plate.3
Indirect reflector has high
reflectance baked matte white
enamel finish for luminous uniformity. A positively retained
direct lamp shield is constructed of heavy gauge perforated
steel with high reflectance
painted after fabrication finish
and milky white overlay diffuser for visual comfort. All
reflectors are precision formed
in a computer-controlled operation.
B…Electrical*
Ballasts are CBM/ETL Class “P” and are
positively secured. Biax models use 2G11
base lampholders with double edge wiping action pressure lock contacts and vertically oriented lamp support clips.T8
models use rotor-lock lampholders for
positive lamp retention. UL/CUL listed.
Suitable for damp locations.
D…Finish
Durable cold rolled steel with
multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition.
2RDI
1BX40
217
BIAXIAL OR T8 LAMPS
B C
A
E
E
2' X 2' Recessed
Direct/Indirect
C e n t e r- M o u n t
D
6"
[152mm]
23-3/4"
[603 mm]
Armstrong® DC FlexZone™
Compatible
LAMP CONFIGURATIONS
MOUNTING DATA
BIAX MODEL
7/8" [22mm] K.O. (1)
23-11/16"
[602mm]
Wiring
Access Plate
7/8"
[22mm]
K.O. (2)
6"
[152mm]
6"
[152mm]
Ballast Access
Plate
3-1/4"
[83mm]
23-3/4"
[603mm]
T8 MODEL
8" [203mm]
23-3/4" [603mm]
ENERGY DATA
7/8" [22mm] K.O. (1)
1-1/2"
[38mm]
2-1/2"
[64mm]
Input Watts:
9-11/16"
[246mm]
6"
[152mm]
6"
[152mm]
3-1/4"
[88mm]
8" [203mm]
23-3/4" [603mm]
6-9/16"
[167mm]
23-3/4"
[603mm]
EB Ballast & STD Lamps
1BX40 (43), 217 (34)
Luminaire Efficacy Rating
LER = FL45
Catalog Number: 2RDI-217RP
23-3/4"
[603mm]
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $5.33
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
T
Slot Grid
F
Drywall Frame
Kit
Ceiling
Type**
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G or T
G or T
***
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Note: Compatible with
Armstrong DC FlexZone 9/16"
Silhouette® (T) and
Suprafine® (G) Grid Systems
COOPER LIGHTING
ADF101843
2RDI
PHOTOMETRICS
Coefficients of Utilization
2RDI-217RP
24V DC Electronic
Ballast
F17T8/35K Lamps
1300 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 64.6%
Test Report:
2RDI-217RP.IES
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
77
70
64
58
53
49
45
42
39
36
34
77
67
59
51
45
41
36
33
30
28
25
77
64
54
46
40
35
31
27
25
22
20
77
62
50
42
35
30
26
23
21
19
17
75
69
62
57
52
48
44
41
38
35
33
75
66
57
50
45
40
36
33
30
27
25
75
62
53
45
39
34
30
27
24
22
20
75
61
50
41
35
30
26
23
21
19
17
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
72
63
55
48
43
38
35
31
29
26
24
69
60
53
47
41
37
34
31
28
26
24
66
58
51
45
40
36
33
30
27
25
23
65
54
45
38
32
28
24
21
19
17
15
72
61
52
44
38
34
30
27
24
22
20
72
59
49
41
35
30
26
23
21
19
17
69
59
50
43
37
33
29
26
24
21
20
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
452
746
1331
1679
1679
17.4
28.7
51.2
64.6
64.6
27.0
44.4
79.3
100.0
100.0
Average
0-Deg
cd/sm
1570
1421
1197
938
656
69
57
48
40
34
30
26
23
20
18
17
66
57
49
42
37
32
29
26
23
21
19
Average
45-Deg
cd/sm
1724
1679
1576
1264
827
66
56
46
39
34
29
26
23
20
18
17
Average
90-Deg
cd/sm
1841
1834
1692
1453
852
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
576
576
569
556
536
511
482
447
408
365
318
268
217
166
120
80
45
19
0
45°
576
575
570
558
542
522
497
469
437
401
361
317
270
219
163
108
63
24
0
Across ⊥
576
576
571
562
550
533
513
490
461
428
391
346
293
235
177
124
70
24
0
LER = FL45
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $5.33
ORDERING INFORMATION
SAMPLE NUMBER: 2RDI-217RP-024V-DC81DIM-U
Rating
Blank=
Standard
NY=New York
City Rated
ATW-SW4=
Chicago
Rated
Number
of Lamps
1=1 Lamp
2= 2 Lamp
Width
2=2' Width
Lamp Shield
X=Solid Matte White
RP=Round Perforated
White Steel
Series
RDI=Ovation
Series
(Recessed
Direct/Indirect)
Ballast Type
DC8 DIM=T8 24VDC
Dimming= 0-10V
Ballast Factor= 1.0
DCX DIM=Biax 24VDC
Dimming= 0-10V
Ballast Factor= 1.0
Voltage
024V=24 Volt DC (1)
Wattage
17=17W T8 (24")
BX40=40W Biax (24") (3)
Options
Lamps=Lamps Installed
Number of Ballasts
1=1 Ballast
2=2 Ballasts
Options
REP=Riveted Endplates, for
use in New York City.
LSC=Lamp Shield Cable
RLS=Rotor-Lock Socket
(T8 Lamps Only)
LVDC5=Low Voltage 5ft. DC
Connector and Cable Assembly
Installed
LVDC10=Low Voltage 10ft. DC
Connector and Cable Assembly
Installed
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(3)
DF-22-W=Drywall Frame Kit
Trim Type
Blank=Grid/Lay-in
(Standard)
Lamp Position
Blank=Center
Mounted Lamps
(standard)
(1)
NOTES: 24VDC version is EMerge Alliance® Registered. (Biax= 1 lamp ballast only, T8= 2 lamp ballast only).
(3)
BX40 is only available in 1-Lamp.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SHIPPING INFORMATION
Catalog No.
Wt.
2RDI-1BX40RP
2RDI-217RP
19 lbs.
19.5 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
5/11
ADF101843
Download