RSLED-Installation High Bay

advertisement
TM
RSLED INSTALLATION
rev. 07-2013
#252380
APPLICATION
RSLED Luminaires are suitable for use in the following areas as defined by the National
Electrical Code (NEC) and the Canadian Electrical Code (CEC):
Class I, Division 2, Groups ABCD;
Class I, Zone 2, IIC, T4
Class II, Division 1 & 2, Groups EFG; Class III, T4
RSLED is designed for use indoors, outdoors, wet locations, and areas containing
moisture, dirt, corrosion, vibration, and rough usage.
HOUSING:
Copper-free Aluminium Cast, 6061 Aluminium and Polycarbonate lens
MOUNTING:
Wallpack:
High Bay:
Remote:
VOLTAGE:
VAC: 90-277 VAC | HDC: 120-300VDC | 347: 347-477VAC
CURRENT Typical:
2.3A@120VAC | 1A@277VAC | 0.8A@347VAC
CONNECTIONS:
3/4” NPT Conduit | Black: Line | White: Neutral | Green: Earth
*For connections use wire rated to a minimum of 95ºC
TEMPERATURE RANGE:
T4: -40° C to 55° C
INGRESS PROTECTION:
IP 65
2-6x 3/8” Bolts
T&B Hook or 2-4x 3/8“ Bolt (surface mounting option)
User supplied bracket with 2x M6
and 2x M5 hex socket bolts.
www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190
1-4
TM
RSLED INSTALLATION
rev. 07-2013
WARNING
WARNING
To avoid the risk of fire, explosion, or electric shock, this
product should be installed, inspected, and maintained
by a qualified electrician only, in accordance with all
applicable electrical codes.
WARNING
To avoid electric shock:
• Be certain electrical power is OFF before and during
installation and maintenance.
• Luminaire must be connected to a wiring system with an
equipment-grounding conductor.
POTENTIAL ELECTROSTATIC Avoid electrostatic discharge :
• Clean Lens surface with damp cloth only
CHARGING HAZARD
HIGH BAY INSTALLATION (SURFACE)
Step 2
1. Inspect shipping package and contents to
ensure no damage has occurred during
shipping.
2. Remove Surface/Wall Bracket from RSLED
Box.
3. Mount Wall Bracket to desired location with
two (2) 3/8” bolts to secure RSLED to ceiling
surface. Ensure placement of bolts in
X pattern as shown by
A
and
Step 3
2.4”
60mm
B
**Recommended to use four (4) in high wind and
vibration environments.
A
B
3.2”
81mm
B
A
1.8”
46mm
2-4
www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190
TM
RSLED INSTALLATION
rev. 07-2013
HIGH BAY INSTALLATION (SURFACE)
Step 4
4. Slide assembled fixture onto Surface/Wall
Bracket.
Step 5
5. Align and mount lower four (4) M6 hardware first then proceed with side four (4) M6
bolts.
3-4
www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190
TM
RSLED INSTALLATION
rev. 07-2013
HIGH BAY INSTALLATION (SURFACE)
6. If required, connect safety backup connection to High Bay backup bracket which can be
mounted to the side of the RSLED Head
Box
A
Step 6
or
B
B
A
Step 7
7. Open RSLED Box lid.
8. Connect desired conduit/wire runs to the
desired 3/4” NPT entry and run wire as per
applicable standards for area of use. For
connections use wire rated to a minimum
of 95ºC.
9. Connect AC in feed to labeled wires in
RSLED box as per applicable standards for
area of use.
Step 10
10. Close RSLED Box lid. Torque lids screws
according to diagram.
8
4
70 in·lbf
10
7
2
1
6
9
3
5
11. Energize fixture.
4-4
www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190