9200 Condensate Trap - Jay R. Smith MFG Co.

advertisement
LOCATION
SMITH ® JAY R.
N
G
GI
N E E RI
an
on R
a th e r T h
C
CONDENSATE TRAP
WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA
S9200
FUNCTION: For the collection of condensate from refrigeration or air conditioning equipment. The
condensate drains, by gravity, through piping to the tapped inlet on the fixture side of the 9200 trap.
4 1/4 (110)
12 (305) MAX
*A
Escutcheon
Slip Joint Nut
and Seal
Wall Tube
1/8 (3)
B
1 1/2" (38) Female
NPT Connection
D
Condensate
Connection
DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE
DRAWING NUMBER
A
SIZE
NONE
SCALE:
9-6-85
DATE:
N
nti
Ground Joint
Elbow
JM
APPROVED BY:
CHECKED BY:
WH
CM
FIGURE
NUMBER
9200
DRAWN BY:
ve
e
MEMBER OF:
Pr
®
®
E
CUSTOMER
DRIVEN
ASPE
POST OFFICE BOX 3237
MONTGOMERY, ALABAMA 36109-0237 (USA)
TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com
e
DIVISION OF SMITH INDUSTRIES, INC.
NITARY
SA
ur
N
SMITH MFG. CO.®
Finished
Wall
C
A (INLET SIZE)
B
C
D
0125/1 1/4" (35) or 0150/1 1/2" (40) 6 (150) 2 7/8 (73) 5 (125)
*1 1/4 (32) and 1 1/2 (38) slip joint nuts are provided
to accommodate the appropriate fixture tailpiece.
Ground joint elbow is threaded 1 1/2 (38) NPT.
NOTE: Dimensions shown in
parentheses are in millimeters.
REGULARLY FURNISHED:
Satin Chrome Plated Cast Bronze
P-Trap with Ground Joint Outlet,
Threaded Wall Tube, Slip Joint Nuts,
Washer, Escutcheon, and 1/2 (13) NPT
Condensate Connection.
N
M
L
K
REV.
7-2-97
12-4-95
7-10-95
5-19-94
DATE
Delete Var. & Chg Reg Furn
Chg'd Reg Furn
Added Millimeters
Add Var, Rev Table, Chg Dwg
DESCRIPTION
OPTIONAL MATERIALS:
Polished Chrome Plated Cast Bronze
P-Trap -CP
EMB
EMB
EMB
EMB
CL
BS
BS
BS
BY
CKD. BY
WEIGHT
POUNDS
VOLUME
CUBIC FEET
FIGURE NUMBER
9200
SMITH ® JAY R.
LOCATION
WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA
A
G
N
G
N
I
I
n ti N E E R n C
a
on R
ath e r T h
TYPICAL INSTALLATION
Refrigeration or
A.C. Unit Above
Ceiling or on Floor
or Roof Above
Condensate Line
Routed Above Ceiling
Condensate Outlet
Jay R. Smith
Air Gap
(When Req'd)
PIT
H
CH
TC
PI
Condensate Line
in Wall
DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE
S9200BS
DRAWING NUMBER
SIZE
NONE
SCALE:
5-20-86
DATE:
APPROVED BY:
CHECKED BY:
SM
DRAWN BY:
9200-BS
FIGURE
NUMBER
ve
e
MEMBER OF:
Pr
®
®
E
CUSTOMER
DRIVEN
ASPE
POST OFFICE BOX 3237
MONTGOMERY, ALABAMA 36109-0237 (USA)
TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com
e
DIVISION OF SMITH INDUSTRIES, INC.
NITARY
SA
ur
D
SMITH MFG. CO.
®
Jay R. Smith
Concealed Arm Support
(When Specified)
Lavatory
Jay R. Smith Figure
9200 Condensate
Trap Drain
D
C
B
A
REV.
2-13-95
2-18-93
7-2-91
6-2-87
DATE
Submittal Update
Revised Trap Drain
Redraw & Chg Fig #
Removed Fig # Add JRS
DESCRIPTION
EMB
TWK
EMB
CMB
CL
McD
CR
CR
BY
CKD. BY
WEIGHT
POUNDS
VOLUME
CUBIC FEET
FIGURE NUMBER
9200-BS
Download