ITEM REFERENCIA DESCRIPCIÓN CANT. 1 PBOC BANCO DE

advertisement
BOMBAS. MÓDULO MEDIO
Ref: 0831
ITEM
1
1 / 2
REFERENCIA
DESCRIPCIÓN
CANT.
PBOC
BANCO DE PRUEBAS MULTIBOMBAS, CONTROLADO
DESDE COMPUTADOR (PC), COMPUESTO POR:
1
PBOC.Unit
BANCO DE PRUEBA DE MULTIBOMBAS
1
PBOC/CIB
CAJA-INTERFACE DE CONTROL ELECTRONICA
PARA BANCO DE PRUEBAS MULTIBOMBAS
1
DAB
TARJETA DE ADQUISICION DE DATOS
1
PBSPC/CCSOF
SOFTWARE DE CONTROL DESDE COMPUTADOR +
ADQUISICION DE DATOS + MANEJO DE DATOS
PARA BANCO DE BOMBAS SERIE/PARALELO
1
2
PBOC/CAL
SOFTWARE DE APRENDIZAJE ASISTIDO DESDE
COMPUTADOR PARA BANCO DE PRUEBA DE
MULTIBOMBAS (CÁLCULO Y ANÁLISIS DE
RESULTADOS)
1
3
PBSPC
BANCO DE BOMBAS SERIE/PARALELO, CONTROLADO
DESDE COMPUTADOR (PC), COMPUESTO POR:
1
PBSPC.Unit
BANCO DE BOMBAS SERIE/PARALELO
1
PBSPC/CIB
CAJA-INTERFACE DE CONTROL ELECTRONICA
PARA BANCO DE BOMBAS SERIE/PARALELO
1
DAB
TARJETA DE ADQUISICION DE DATOS
1
PBOC/CCSOF
SOFTWARE DE CONTROL DESDE COMPUTADOR +
ADQUISICIÓN DE DATOS + MANEJO DE DATOS PARA
EL BANCO DE PRUEBAS MULTIBOMBA
1
4
PBSPC/CAL
SOFTWARE DE APRENDIZAJE ASISTIDO DESDE
COMPUTADOR PARA BANCO DE BOMBAS
SERIE/PARALELO (CÁLCULO Y ANÁLISIS DE
RESULTADOS)
1
5
0831PARTS
COMPONENTES Y REPUESTOS
1
6
0831PA
PARTIDA ALZADA
1
7
0831IYPM
INSTALACIÓN Y PUESTA EN MARCHA
1
8
0831CAPRO
CAPACITACIÓN Y ACTUALIZACIÓN DE PROFESORES
1
9
0831TD
TÉCNICAS DIDÁCTICAS "KNOW-HOW"
1
0831MANU
DOCUMENTACIÓN Y MANUALES
1
10
Ref: 0831
ITEM
2 / 2
REFERENCIA
DESCRIPCIÓN
Notas:
a)Opción de multipuesto:
* Este módulo tiene una unidad solamente en cada item, nosotros podemos recomendar el número
de unidades para que 10 o 30 estudiantes puedan trabajar simultáneamente.
b)Condiciones de suministro:
* Condiciones técnicas:
- Adaptación de los laboratorios.
- Instalación de todos los equipos.
- Puesta en marcha de todos los equipos.
- Entrenamiento de cada uno de los ejercicios a ser realizados con cada uno de los equipos.
- Formación de profesores, relacionada con cada equipo didáctico y cada una de las técnicas de
enseñanza aplicada.
- Transferencia de tecnología.
* Condiciones comerciales:
- Embalaje.
- Gastos de financiación.
- Gastos C.I.F.
* Otras condiciones:
- 8 Manuales para cada uno de los equipos didácticos de EDIBON:
. Manual de servicios requeridos.
. Manual de montaje e instalación.
. Manual de la interface y del software/consola de control.
. Manual de puesta en marcha.
. Manual de normas de seguridad.
. Manual de prácticas.
. Manual de mantenimiento.
. Manual de calibración.
Ver catálogos en las páginas siguientes
CANT.
8.4- Hydraulic Machines (Pumps)
PBOC. Computer Controlled Multipump Testing Bench (4 type of pumps)
Teaching
Technique
used
SCADA. EDIBON Computer Control System
3
2
4
Data
Software for:
Acquisition - Computer Control
Board
- Data Acquisition
- Data Management
5 Cables and Accessories
6 Manuals
Control
Interface Box
1
Unit: PBOC. Multipump Testing Bench
(4 types of pumps)
OPEN CONTROL + MULTICONTROL + REAL TIME CONTROL
PRACTICAL POSSIBILITIES
SPECIFICATIONS SUMMARY
Items supplied as standard
PBOC. Unit:
Anodized aluminium structure. Diagram in the front panel with similar distribution that the
elements in the real unit.
Fully instrumented self-contained unit. 4 pumps: Centrifugal pump, Axial flow pump, Gear pump
and Peripherical pump. Motor for each pump, with independent operating.
Admission pressure sensors and discharge pressure sensor for each pump. Control software for
the direct reading of speed (r.p.m.) and torque (Nm). Variation of speed by frequency converter. 8
Admission and discharge pressure sensors. Calibrated volumetric tank. Storage tank, with
approx. capacity of 160 litres. “U” Shape weir. Transparent elements. 2 Stilling baffles in the open
channel. Level sensor. Valves for centrifugal, peripherical and gear pumps. Control valve for axial
pump.
2 PBOC/CIB. Control Interface Box :
With process diagram in the front panel. The unit control elements are permanently computer
controlled. Simultaneous visualization in the computer of all parameters involved in the process.
Calibration of all sensors involved in the process. Real time curves representation. All the
actuators’ values can be changed at any time from the keyboard. Shield and filtered signals to
avoid external interferences. Real time control with flexibility of modifications from the computer
keyboard of the parameters, at any moment during the process. Open control allowing
modifications, at any time and in a real time, of parameters involved in the process. 3 safety levels:
mechanical in the unit, electronic in control interface, and the third one in the control software.
3 DAB. Data Acquisition Board:
PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog
inputs. Sampling rate up to: 250 KS/s . 2 Analog outputs. 24 Digital Inputs/Outputs.
4 PBOC/CCSOF. Computer Control+Data Acquisition+Data Management Software:
Flexible, open and multicontrol software. Management, processing, comparison and storage of
data. Sampling velocity up to 250,000 data per second. It allows the registration of the alarms
state and the graphic representation in real time.
5 Cables and Accessories, for normal operation.
6 Manuals: This unit is supplied with 8 manuals.
Dimensions (approx.) =Unit: 1650x800x1850 mm. Weight: 225 Kg.
Control Interface: 490x450x470 mm. Weight: 20 Kg.
1
More information in: www.edibon.com/products/catalogues/en/units/
fluidmechanicsaerodynamics/hydraulicmachinespumps/PBOC.pdf
1.- Determination of the flow by a weir of thin wall in U-shape.
2.- Determination of unloading coefficient of a weir of thin wall in a
U-shape.
3.- Calibration of a flow sensor.
4.- Determination of the curve Q vs r.p.m. for centrifugal pumps
5.- Determination of the curve Q vs r.p.m. for peripherical pumps.
6.- Determination of the curve Q vs r.p.m. for gear pumps.
7.- Determination of the curve Q vs r.p.m. for axial pumps.
8.- Determination of the curve H vs Q for different r.p.m. for
centrifugal pumps.
9.- Determination of the curve H vs Q for different r.p.m. for
peripherical pumps.
10.-Determination of the curve H vs Q for different r.p.m. for gear
pumps.
11.-Determination of the curve H vs Q for different r.p.m. for axial
pumps.
12.-Determination of the mechanical power vs flow for different
r.p.m. for centrifugal pumps.
13.-Determination of the mechanical power vs flow for different
r.p.m. for gear pumps .
14.-Determination of the mechanical power vs flow for different
r.p.m. for peripherical pumps.
15.-Determination of the mechanical power vs flow for different
r.p.m. for axial pumps.
16.-Determination of the curve h vs the flow for different r.p.m. for
centrifugal pumps.
17.-Determination of the curve h vs the flow for different r.p.m. for
peripherical pumps.
18.-Determination of the curve h vs the flow for different r.p.m. for
gear pumps.
19.-Determination of the curve h vs the flow for different r.p.m of an
axial pumps.
20.-Determination of the map of a centrifugal pump.
21.-Determination of the map of a peripherical pump.
22.-Determination of the graphic of a gear pump.
23.-Determination of the graph of an axial pump.
24.-Determination of the adimensional characteristic curves for
different types of pumps
25.-Determination of the specific speed of different types of pumps.
26.-Verification of the similarity rules for pumps of different
geometries.
Other possible practices:
27.- Sensors calibration.
28-46.- Practices with PLC.
PBCC. Computer Controlled Centrifugal Pump Bench
Always included
in the supply:
Teaching
Technique
used
SCADA. EDIBON Computer Control System
2
3
Data
Acquisition
Board
5 Cables and Accessories
6 Manuals
Control
Interface Box
1
Unit: PBCC. Centrifugal Pump Bench
4
Software for:
- Computer Control
- Data Acquisition
- Data Management
OPEN CONTROL + MULTICONTROL + REAL TIME CONTROL
SPECIFICATIONS SUMMARY
Items supplied as standard
PBCC. Unit:
Anodized aluminium structure. Diagram in the front panel with similar distribution that the elements in the real unit.
Centrifugal pump: maximum flow: 80 l/min,maximum height (approx.): 20 mwc (meter of water column), pump-and-engine-set
coupled to an AC motor.
Regulating valves. Discharge pressure sensor. Admission Pressure sensor. Flow sensor. By the previous sensors we can make the
measurement of the most representative parameters of the pump: speed, torque, total impelled flow, the admission and
discharge pressure. Pump speed adjustable from the computer. Water tank.
2 PBCC/CIB. Control Interface Box :
With process diagram in the front panel. The unit control elements are permanently computer controlled. Simultaneous
visualization in the computer of all parameters involved in the process. Calibration of all sensors involved in the process. Real time
curves representation. All the actuators’ values can be changed at any time from the keyboard. Shield and filtered signals to avoid
external interferences. Real time control with flexibility of modifications from the computer keyboard of the parameters, at any
moment during the process. Open control allowing modifications, at any time and in a real time, of parameters involved in the
process. 3 safety levels: mechanical in the unit, electronic in control interface, and the third one in the control software.
3 DAB. Data Acquisition Board:
PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to: 250
KS/s. 2 Analog outputs. 24 Digital Inputs/Outputs.
4 PBCC/CCSOF.Computer Control+Data Acquisition+Data Management Software:
Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Sampling velocity up to
250,000 data per second. It allows the registration of the alarms state and the graphic representation in real time.
5 Cables and Accessories, for normal operation.
6 Manuals: This unit is supplied with 8 manuals.
Dimensions (approx.) =Unit: 1500x800x600 mm. Weight: 100 Kg. Control Interface: 490x330x310 mm. Weight: 10 Kg.
PRACTICAL POSSIBILITIES
1
1 .- Obtaining of curves H(Q), N(Q)
and Eff%(Q).
2 .- Simultaneons representation of
H(Q), N(Q) and Eff%(Q).
3 .- Obtaining the map of a
centrifugal pump.
4 .- A d i m e n s i o n a l s t u d y o f
magnitudes H*, N * and Q *.
5 .- Cavitation test and obtaining of
curves NPSHr.
Other possible practices:
6 .- Sensors calibration.
7-25.- Practices with PLC.
More information in: www.edibon.com/products/catalogues/en/units/fluidmechanicsaerodynamics/
hydraulicmachinespumps/PBCC.pdf
Non computer controlled version available.
Page 23
www.edibon.com
8.- Fluid Mechanics & Aerodynamics
Always included
in the supply:
8.4- Hydraulic Machines (Pumps)
(continuation)
PBSPC. Computer Controlled Series/Parallel Pumps Bench
8.- Fluid Mechanics & Aerodynamics
Always included
in the supply:
Teaching
Technique
used
SCADA. EDIBON Computer Control System
3
2
Data
Acquisition
Board
5 Cables and Accessories
6 Manuals
Control
Interface Box
1
Unit: PBSPC. Series/Parallel Pumps Bench
4
Software for:
- Computer Control
- Data Acquisition
- Data Management
OPEN CONTROL + MULTICONTROL + REAL TIME CONTROL
SPECIFICATIONS SUMMARY
Items supplied as standard
PBSPC. Unit:
Anodized aluminium structure. Diagram in the front panel with similar distribution that the elements in the real unit.
2 Centrifugal pumps. Electrical AC motors. 5 valves that allow connecting the pump separately in series or in parallel by the
appropriate positioning of the valves. Two of these valves are regulating valves. 2 Discharge pressure sensors. Admission
pressure sensor. Flow sensor. Torque measurement. Speed measurement. Speed controller. By the previous sensors we can
make measurement of the most representative parameters of the pumps and their couplings (series/parallel): speed, torque,
total impelled flow, admission and discharge pressure. Pumps speed adjustable from the computer. Water tank.
2 PBSPC/CIB. Control Interface Box :
With process diagram in the front panel. The unit control elements are permanently computer controlled. Simultaneous
visualization in the computer of all parameters involved in the process. Calibration of all sensors involved in the process. Real
time curves representation. All the actuators’ values can be changed at any time from the keyboard. Shield and filtered
signals to avoid external interferences. Real time control with flexibility of modifications from the computer keyboard of the
parameters, at any moment during the process. Open control allowing modifications, at any time and in a real time, of
parameters involved in the process. 3 safety levels: mechanical in the unit, electronic in control interface, and the third one in
the control software.
3 DAB. Data Acquisition Board:
PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to:
250 KS/s .2 Analog outputs. 24 Digital Inputs/Outputs.
4 PBSPC/CCSOF.Computer Control+Data Acquisition+Data Management Software:
Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Sampling velocity up
to 250,000 data per second. It allows the registration of the alarms state and the graphic representation in real time.
5 Cables and Accessories, for normal operation.
6 Manuals: This unit is supplied with 8 manuals.
Dimensions (approx.) =Unit: 1530x 770x 1000 mm. Weight: 105 Kg. Control Interface: 490x330x310 mm. Weight: 10 Kg.
1
PRACTICAL POSSIBILITIES
1.-
Obtaining of curves H(Q), N(Q),
Eff%(Q).
2.- Three simultaneous representatios
of H(Q), N(Q) and Eff%(Q).
3.- Obtaining of the map of a
centrifugal pump.
4.- Adimensional study of magnitudes
H*, N* and Q*.
5.- Cavitation test and obtaining of
curves NPSHr.
6.- Series coupling of two pumps with
same characteristics.
7.- Series coupling of two pumps of
different characteristics.
8.- Parallel coupling of two pumps
with same characteristics.
9.- Parallel coupling of two pumps of
different characteristics.
Other possible practices:
10.- Sensors calibration.
11-29.- Practices with PLC.
More information in: www.edibon.com/products/catalogues/en/units/fluidmechanicsaerodynamics/
hydraulicmachinespumps/PBSPC.pdf
PBEC. Computer Controlled Gear Pump Bench
Always included
in the supply:
Teaching
Technique
used
SCADA. EDIBON Computer Control System
Water inlet
2
Gear pump detail
Water outlet
Gear pump scheme
1
3
Data
Acquisition
Board
5 Cables and Accessories
6 Manuals
Control
Interface Box
4
Software for:
- Computer Control
- Data Acquisition
- Data Management
Unit: PBEC. Gear Pump Bench
OPEN CONTROL + MULTICONTROL + REAL TIME CONTROL
SPECIFICATIONS SUMMARY
Items supplied as standard
Unit:
Anodized aluminium structure. Diagram in the front panel with similar distribution that the elements in the real unit. Gear
pump with carcass of a fused piece and two rotors in form of a straight cylindrical gear, shaft maximum speed: 1450 r.p.m.,
_ 6 bar, maximum viscosity: 100,000 with 200 r.m.p. motor speed, transversal section of
working pressure: 100 psi ~
admission and unload: 1/4 “1.227 cm2., level different (un-ad): 6.5 cm., maximum flow: 20 l/m, shaft diameter x center
line: 1/2x2.36, pressure sensors (admission): 0-5 psi (differential), pressure sensors (unload): 0- 100 psi (absolute). Sensors:
flow, speed, torque measurement, admission pressure, unload pressure. Regulation Valves. Speed controller. Tank and
pipes.
2 PBEC/CIB. Control Interface Box :
With process diagram in the front panel. The unit control elements are permanently computer controlled. Simultaneous
visualization in the computer of all parameters involved in the process. Calibration of all sensors involved in the process. Real
time curves representation. All the actuators’ values can be changed at any time from the keyboard. Shield and filtered
signals to avoid external interferences. Real time control with flexibility of modifications from the computer keyboard of the
parameters, at any moment during the process. Open control allowing modifications, at any time and in a real time, of
parameters involved in the process. 3 safety levels: mechanical in the unit, electronic in control interface, and the third one in
the control software.
3 DAB. Data Acquisition Board:
PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to:
250 KS/s. 2 Analog outputs. 24 Digital Inputs/Outputs.
4 PBEC/CCSOF.Computer Control+Data Acquisition+Data Management Software:
Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Sampling velocity up
to 250,000 data per second. It allows the registration of the alarms state and the graphic representation in real time.
5 Cables and Accessories, for normal operation.
6 Manuals: This unit is supplied with 8 manuals.
Dimensions (approx.) =Unit: 1300x790x1400 mm. Weight: 80 Kg. Control Interface: 490x330x310 mm. Weight: 10 Kg.
1 PBEC.
More information in: www.edibon.com/products/catalogues/en/units/fluidmechanicsaerodynamics/
hydraulicmachinespumps/PBEC.pdf
Non computer controlled version available.
Page 24
PRACTICAL POSSIBILITIES
1.- Demonstration of a gear pump in
operation.
2.- Obtaining of curves H(Q), N(Q),
h(Q) of gear pump.
3.- Determination of the curve H vs Q
for different r.p.m.
4.- Determination of the mechanical
power vs flow for different r.p.m.
5.- Determination of the curve h vs the
flow for different r.p.m.
6.- Determination of the map of a gear
pump.
7.- Determination of the characteristic
curves.
8.- Determination of the specific speed.
Other possible practices:
9.- Sensors Calibration.
10-28.- Practices with PLC.
Download