R-Series Remote Annunciators

advertisement
Edwards Signaling Catalog u Annunciation
R-Series Remote
Annunciators
E-RLCD, E-RLCD-C, E-RLED-C,
RLED24, GCI
Overview
Features
Edwards R-Series Annunciators are high-performance remote
annunciators that provide status indication and common controls
for compatible fire alarm control panels, including E-FSA-Series
small analog fire alarm systems. This family of annunciators offers
LCD or LED annunciation. Models are available with and without
common controls.
• LCD models feature large 4 x 20 character backlit LCD display
There are three R-Series annunciator models, plus an LED-based
expander. Up to two expanders can be connected to any annunciator. The expander includes 24 pairs of LEDs that extend the
capabilities of any of the annunciators.
All annunciator models include status LEDs and an internal buzzer.
Two models have an LCD text display, and one has 16 pairs of
LEDs for zone annunciation. LCD models feature a large back-lit,
four by twenty character per line, super-twist liquid crystal display.
R-Series annunciators and expanders are mounted on a standard
4-inch square electrical box, using the included mounting ring.
They can also be surface mounted in locking steel enclosures.
Three different enclosures are available.
• LED models provide 16 pairs of LEDs for zone annunciation
• Available expander extends capability with 24 pairs of LEDs
• Up to two expanders may be wired to each annunciator
• Status LEDs and internal buzzer standard on all models
• Common controls available for LED and LCD display models
• Available keyswitch for disabling common controls
• Standard 4-inch square electrical box mounting
• Class B or Class A RS485 wiring standard
• One-, two-, and three-position enclosures available
• Graphic Annunciator interface, includes common control, indicators and 32 LEDS
• No programing required, set the address and unit recieves all
information from panel
A keyswitch and graphic annunciator interface is available for
R-Series annunciator applications. The keyswitch enables or disables common controls. The graphic annunicator interface cards
supports 32 LEDs and 16 switches on the graphic panel display.
Page 1 of 4
S85005-0128
D ATA S H E E T
Not to be used for installation purposes. Issue 2
RLCD-C
Application
Annunciator Wiring
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
R-Series annunciators communicate with the FACP on the RS‑485
data riser. This can be configured for Class A or Class B communication. Annunciators do not provide ground fault isolation.
Ack/Silence
Lamp Test
These annunciators are stand-alone units that can be powered by
FACP
the FACP or by an approved power supply.
RLCD
RS-485
CH1 +
CH1 –
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Ack/Silence
Ack/Silence
CH2 +
Annunciator, Class A
FACP
Annunciator
Annunciator
RS-485
FACP
CH1 +
RS-485
CH1 –
CH1
CH2 +
+
CH1 (+) IN
Annunciator
CH1 (–) IN
CH1
CH1 (+)
(+) IN
OUT
CH1 (+) IN
Annunciator
CH1 (–) IN
CH1
CH1 (+)
(+) IN
OUT
Annunciator
CH1 (+) IN
CH1
CH2 –
–
CH2 +
CH1 (–) IN
CH1 (+) OUT
CH2 –
LISTED 24 VDC
SUPPLY
CH1 (–) OUT
CH2 (+) IN
CH2 –
LISTED
24 +
VDC
24 VDC
SUPPLY
Reset
24 VDC –
Signal SilenceLISTED 24 VDC
24 VDC +
SUPPLY
Drill
24 VDC –
Lamp Test
24 VDC +
Reset
Signal Silence
Drill
Lamp Test
CH2 (–) IN
CH2 (+) OUT
CH2 (–) OUT
24V (+) IN
24 VDC –
24V (–) IN
24V (–) OUT
CH1
CH2 ((–
–)) OUT
IN
CH2 (+)
(+) OUT
IN
CH2
CH1 (–) IN
CH2
–) IN
CH2 ((–)
OUT
CH2
(+) IN
OUT
24V (+)
CH1 (–) OUT
CH2
OUT
24V ((–)
–) IN
24V
24V (+)
(+) IN
OUT
CH2 (–) IN
24V
24V ((–
–)) IN
OUT
24V (+) OUT
GROUND
24V (–) OUT
CH2 (–) OUT
Ack/Silence
FACP
RS-485
Lamp Test
RLED24
RLCD
E-RLCD
Annunciator
CH1 (+) IN
CH1 –
CH1 (–) IN
CH1 +
CH1 –
Features by
model
RS-485
FACP
CH1 +
RS-485
CH1 –
CH1 +
E-RLCD-C
E-RLED-C
CH1 (+) OUT
LISTED 24 VDC
SUPPLY
CH1 (–) OUT
CH2 (+) IN
LISTED
24 +
VDC
24 VDC
SUPPLY
24 VDC –
24 VDC +
LISTED 24 VDC
SUPPLY
24 VDC –
24 VDC +
CH2 (–) IN
RLED24
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Reset



Ack/Silence



Fire Alarm



Supervisory



Ground Fault



Trouble



Controls EnabledRLED-C



Ack/Silence



Reset


Signal Silence


Drill


Lamp Test



LCD Display


Zone Active LEDs
16 *
24 **
Zone Trouble LEDs
16
24
* zones 13-16 may be selected as Supervisory on E-FSA64
RLED24
** zones 13-16 and
29-32 may be selected as Supervisory on E-FSA250
CH2 (+) OUT
CH2 (–) OUT
24V (+) IN
24 VDC –
24V (–) IN
Ack/Silence
24V (–) OUT
Signal Silence
CH2
–) IN
CH2 ((–)
OUT
CH2
(+) IN
OUT
24V (+)
CH2 (+) IN
CH2
OUT
24V ((–)
–) IN
24V
24V (+)
(+) IN
OUT
CH2 (+) OUT
24V
24V ((–
–)) IN
OUT
24V (+) OUT
GROUND
24V (–) OUT
24V (+) IN
24V (–) IN
24V (+) OUT
GROUND
GROUND
24V (–) OUT
GROUND
Annunciator
Annunciator
CH1 (+) IN
Annunciator
CH1 (–) IN
CH1
CH1 (+)
(+) IN
OUT
CH1 (+) IN
Annunciator
CH1 (–) IN
CH1
CH1 (+)
(+) IN
OUT
Annunciator
CH1
CH1 ((–
–)) IN
OUT
CH1 (+)
(+) IN
OUT
CH2
CH1
CH1 ((–
–)) IN
OUT
CH1 (+)
(+) IN
OUT
CH2
CH1 (+) IN
CH1
CH2 ((–
–)) OUT
IN
CH2
CH2 (+)
(+) IN
OUT
CH1 (–) IN
CH2
–) IN
CH2 ((–)
OUT
CH2
(+) IN
OUT
24V (+)
CH1 (–) OUT
CH2
OUT
24V ((–)
–) IN
24V (+)
(+) OUT
IN
24V
CH2 (–) IN
24V
24V ((–
–)) IN
OUT
24V (+) OUT
GROUND
24V (–) OUT
CH2 (–) OUT
CH1
CH2 ((–
–)) OUT
IN
CH2
CH2 (+)
(+) IN
OUT
CH1 (+) OUT
CH2
–) IN
CH2 ((–)
OUT
CH2
(+) IN
OUT
24V (+)
CH2 (+) IN
CH2
OUT
24V ((–)
–) IN
24V (+)
(+) OUT
IN
24V
CH2 (+) OUT
24V
24V ((–
–)) IN
OUT
24V (+) OUT
GROUND
24V (–) OUT
24V (+) IN
24V (–) IN
24V (+) OUT
Reset
CH1
CH2 ((–
–)) OUT
IN
CH2 (+)
(+) OUT
IN
CH2
CH1 (+) OUT
GROUND
Annunciator,
Class B
FACP
Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
CH1
CH1 ((–
–)) IN
OUT
CH1
CH2 (+)
(+) OUT
IN
CH1 (+) IN
24V (+) OUT
RLED-C
RLCD-C
Annunciator
CH1
CH1 ((–
–)) IN
OUT
CH1
CH2 (+)
(+) OUT
IN
24V (+) OUT
GROUND
GROUND
24V (–) OUT
Drill
GROUND
Lamp Test
Expander
Annunciator
GROUND
Annunciator
First Expander
Second Expander
OUT
Annunciator
V (–)
V OUT
(+)
IN
OUT
First Expander
V (–)
V (–)
IN
V (+)
V OUT
(+)
IN
OUT
Second Expander
V (–)
V (–)
IN
V (+)
V OUT
(+)
OUT
V (–F)
V (+)
E
V (–)
First Expander
IN
V
F (–)
OUT V (+)
E
V (–) F
D
V (+) E
C
F D
B
E C
A
D B
F
D
E
C
V (–)
D
B
C
A
F
D
B
D
C
A
C
C
B
B
A
A
V (+)
F
E
V (+)
E
V (–F)
V (+)
E
Second Expander
IN
V
F (–)
OUT V (+)
E
V (–) F
D
V (+) E
C
F D
B
E C
A
D B
F
D
E
C
V (–)
D
B
C
A
F
B
D
A
C
C
B
B
B
A
A
A
A
V (+)
E
A
V (–F)
V (+)
E
F
D
E
C
D
B
C
A
B
A
Graphic Annunicator Interface
The GCI Graphic Annunciator Driver is an interface card that
connects the fire alarm control panel to the display panel of an
LED-based graphic annunciator.
The annunciator card supports 32 LEDs and 16 switches on the
graphic panel display. It includes status LEDs and an internal
buzzer.
The graphic interface is supplied with snap track mounting. It is
attached to a plastic mounting rail that requires two EIA panels.
The annunciator communicates with the FACP on the RS‑485
data riser. This can be configured for Class A or Class B communication. The annunciator does not provide ground fault isolation.
It is a stand-alone unit that can be powered by the FACP or by an
approved power supply.
Graphic Annunciator Interface Specifications
Alarm current
146 mA at 24 Vdc (with 36 LEDs ON)
Standby current
36 mA at 24 Vdc (with no LEDs ON)
Maximum current
10 mA per LED
Page 2 of 4
Remote Keyswitch
Annunciator
LSRA-RK
KEYSWITCH (–)
TB1-1
KEYSWITCH (+)
TB1-2
Keyswitch Specifications
Maximum
5 Vdc
voltage
Maximum
200 mA
current
Mounting
2-1/2 in (64 mm)
deep 1-gang box
Termination
Screw terminals
Maximum
12 AWG
wire size
(2.5 mm sq)
Contact
Normally open
configuration
S85005-0128
D ATA S H E E T
Not to be used for installation purposes. Issue 2
Annunciator Connections
Annunciator Mounting
Annunciator
ANNUNCIATOR
RS-485 RISER
Mounting slot
Mounting slot
DIP switch
DIP switch
CH1 (+) IN
CH1 (-) IN
RS-485 riser
terminals
RS-485
riser
Communication
Power
terminals
LEDs
Communication
LEDs
(+)
CH1
(-)(+)
OUT
CH1
IN
N/C
CH2
CH1(+)
(-) IN
V(-)(-)
CH2
IN
CH1
(+) (-)
OUT
V
(+)(+)
CH2
CH1(+)
(-) OUT
N/C
F
V (-)
E
V (+)
D
C
F
B
E
A
D
CH2
(-)(+)
OUT
CH2
IN
Power terminals
24V
CH2(+)
(-) IN
IN
CH224V
(+) (-)
OUT
24V
CH2(+)
(-) OUT
24V
(-)(+)
OUT
24V
IN
24V (-) IN
TX
RX
24V (+) OUT
24V (-) OUT
TX
Remote keyswitch
terminals
Remote
keyswitch
(-)
CH1 (+) OUT
terminals
Expander cable
terminals
Expander cable
OUT
OUT
terminals
C
B
A
RX
Expander
Mounting slot
Mounting slot
EXPANDER CABLE
V (-)
Expander cable
terminals
Expander
cable
IN
IN
terminals
V (-)
V (+)
V (+)
F
V (-)
E
V (+)
D
C
F
B
E
A
D
F
V (-)
E
V (+)
D
C
F
B
E
A
D
C
B
A
Expander cable
terminals
Expander cable
OUT
OUT
terminals
C
B
A
DIP switch settings
Switch
Description and values
S1 to S5
The annunciator network address (in binary).
Network
The factory setting is for address 2.
address
Examples: 10000 = 1 01000 = 2 11000 = 3 00100 = 4
S6 Network
OFF = 9600 baud (factory default setting)
baud rate
ON = 38,400 baud
S7 to S8
Not used
EXPANDER
MOUNTING RING
ELECTRICAL BOX
Annunciator Enclosures
The RA Remote Annunciator Enclosures provide secure, surface
mounted protection for annunciators and extenders. Each consists of a back plate, hinged cover, and key lock.
The enclosures are 16-gauge welded steel with a white, painted
finish. Each enclosure includes a security lock and two keys. The
two- and three-position enclosures have wiring channels for correct routing of interconnections.
6.0 in
15.2 cm
H
The enclosures attach to a standard electrical box, and provide a
mounting lip that takes the place of the integral mounting ring supplied with the annunciators and expanders.
0.9 in
2.3 cm
RA-ENC1
9.5 in
24.1 cm
9.8 in
24.9 cm
RA-ENC3
RA-ENC2
Page 3 of 4
2.0 in
5.1 cm
Dimensions (H x W x D)
RA-ENC1
6.3 x 9.8 x 2.0 in (16.0 x 24.9 x 5.1 cm)
RA-ENC2
12.0 x 9.8 x 2.0 in (30.5 x 24.9 x 5.1 cm)
RA-ENC3
17.7 x 9.8 x 2.0 in (45.0 x 24.9 x 5.1 cm)
Note: Allow approximately 2 inches (50 cm) clearance on both sides of the
enclosure, to permit inserting and removing the key, and opening the door
through 90 degrees.
S85005-0128
D ATA S H E E T
Not to be used for installation purposes. Issue 2
Specifications
E-RLCD-C
E-RLCD
Standby current
99 mA
98 mA
28 mA
6 mA
Alarm current
115 mA
113 mA
62 mA
34 mA
Operating voltage
Contact us...
Phone: 1-800-336-4206
Web: www.edwardssignaling.com
Edwards Signaling is
an EDWARDS brand.
3 Farm Glen Boulevard
Farmington, CT 06032
In Canada, contact Chubb Edwards...
Email: inquiries@chubbedwards.com
Web: www.chubbedwards.com
© 2013 UTC Fire & Security Americas
Corporation, Inc. All rights reserved.
Specifications subject to change
without notice. Edwards is part of UTC
Climate, Controls & Security, a unit of
United Technologies Corporation.
Remote key switch circuit
RLED24
24 VDC, continuous.
RS-485 communications
Data wiring
E-RLED-C
Class A or Class B, 9600 baud
18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot
minimum). Maximum wire run is 4,000 ft. (1,219 m)
5 VDC at 1 mA, power-limited, unsupervised
Ground fault impedance
0
Power wiring
18 to 14 AWG (1.0 to 2.5 sq. mm)
Display area
4 lines of 20 characters each
Dimensions (H x W x D)
Mounting
5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm)
North American 4-inch square electrical box or listed enclosure
Agency Listing
Operating environment
UL, ULC
Temperature: 32 to 120°F (0 to 49°C) Humidity: 0 to 93% RH,
noncondensing at 90°F (32°C)
Ordering Information
Part
Description
Remote Annunciators
E-RLCD
LCD text annunciator without common controls. English.
E-RLCD-C
LCD text annunciator with common controls. English.
E-RLED-C
16-pair LED zone annunciator with common controls. English.
Remote Expanders
RLED24
24-pair LED zone expander with expander cable and zone card insert.
Enclosures
RA-ENC1
One-position enclosure for Remote Annunciator.
RA-ENC2
Two-position enclosure for Remote Annunciator and one Remote Expander,
including one interconnection cable.
RA-ENC3
Three-position enclosure for Remote Annunciator and two Remote Expanders,
including two interconnection cables.
LSRA-SB
Surface Mount Box - for single R Series annunciator.
Graphic Annunciator Drivers
GCI
Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm/
supv zones as well as inputs for common switches. Provided with a snap track for
mounting in custom graphic enclosures.
Accessories
RKEY
Remote key switch on plate for enabling or disabling common controls (Lock/
Unlock).
27193-16
Electrical box, surface mount, white, single-gang, for RKEY.
S85005-0128
D ATA S H E E T
Not to be used for installation purposes. Issue 2
06-27-13
Page 4 of 4
Download