Panel Wiring
AMP
DVE
Input
Output
Approval
1AMP
DVE Switching Adaptor
100-240VAC 50/60Hz, 0.3A
12VDC, 1.0A, 12W
UL, cUL
Dimensions 1 3/4” x 2 3/4” x 1 1/8”
AMP
DVE
Input
Output
Approval
3AMP
DVE Switching Adaptor
100-240VAC 50/60Hz, 1.2A
12VDC, 3.0A, 36W
UL, cUL approved. Level 3
Dimensions 2 1/4” x 4” x 1 3/8”
AMP
DVE
Input
Output
Approval
5AMP
DVE Switching Adaptor
100-240VAC 50/60Hz, 1.5A
12VDC, 5.0A, 60W
UL, cUL, CE, FCC, CCC
approved. Level 3
Dimensions 2 1/8” x 4 3/4” x 1 1/2”
5’
LED
Light
Panel
5’
5’
#22 AWG
Power Adaptor (3A/5A)
Fawoo Spider Connector
1. Fawoo LED light panels are powered by Fawoo DC12V (constant voltage) power adaptors. Do not apply any other voltages, as it may damage
the panels. Warranty is void if using any other power adaptors that are not
approved by Fawoo Canada,
2. The power adaptor that came with your LED light panel is either a 12V/1A
(12W), 12V/3A (36W), or 12V/5A(60W). Check the description information
consumption of the LED light panel is less than the rated wattage of the
power adaptor. This will avoid over heating of the power adaptors.
3. Any adjusted cords from the power adaptor to LED light panel should
be kept as short as possible to avoid any voltage drop to the LED light (by
default it is about 10’ at #22AWG).
4. One power adaptor can supply power to multiple of LED light panels
as long as the total wattage of the LED light panels are less than the total
wattage of the power adaptor. In this case, a convenient way of connecting multiple panels is to use a Fawoo spider connector (split connector).
Available are 3 kinds of spider connectors (2-way, 4-way, and 6-way). The
2-way and 4-way connectors have long cables, while the 6-way connector
has a short cable between each DC plug.
2P Parallel long connector
1500mm
5. In case it is required to install the power adaptor in a remote location far
from the LED light panels, you can cut off the DC plug and extend the cable
using a larger gauge (> #16 AWG) cable to avoid any voltage drop. The
wire with a solid stripe is “+” and the other wire is “-“. Reversing the polarity
does not damage the LED lights.
1500mm
Molded T Connector
1500mm
4P Parallel long connector
1500mm
6P Parallel short connector
2468 22AWG
800mm
White stripe
+
Black
-
100mm
100mm
200mm
Cable length as
short as possible
2468 22AWG
1500mm
Molded T Connector
100mm
+
Molded DC
Male Connector
LED Light
Panel
#16 AWG
12V DC
Output
Power
Adaptor
110V AC
2700 John St. Markham ON, L3R 2W4 Canada
6. If multiple panels are wired to a single power adaptor, connect them in
“parallel” instead of “series” to avoid voltage drop in order to maximize the
light output.
12V DC
Output
Instruction # 6
T: 905-474-0555
Power
Adaptor
7. Never apply AC power directly to the LED light panels as this will instantly damage the LEDs.
LED Light
Panel #1
LED Light
Panel #2
Dimmer Device
12V DC
Output
Power
Adaptor
LED Light
Panel #1
8. The brightness of different size panels are usually different. Special care
has to be taken to match the brightness when they are installed together.
Consult our technical support person for details.
LED Light
Panel #2
1. Fawoo LED light panels can only be dimmed with a Fawoo DC dimmer.
The dimmer consists of 3 components: dimmer main body, a sensor and
a wireless remote control. Connect securely the DC plug of power adaptor
and the DC plug of the panels to the dimmer main body. Remove the battery protection sheet in the remote control. Point the remote control to the
sensor to dim the panels. (Max/Min/On/Off +/-)
2. The dimmer capacity is up to 60W each.
(large size panels with two power connectors with the total wattage exceeding 60W, you have to use 2 dimmers.)
Instruction # 7
110V AC
LED Light
Panel #1
3. To control multiple panels with one remote control pad, put all sensors
together. As long as the total wattage of all panels is less than 60W, you
can use one dimmer to dim multiple panels.
Fawoo
Dimmer
12V DC
Output
Main
Body
Power
Adaptor
Dimmer Wiring
110V AC
Dimmer Sensor
Dimmer
LED Light
Panel
Sensor
Spider Connector
Fawoo
Dimmer
Remote
110V AC
LED Light
Panel #1
Power
Adaptor
LED Light
Panel #2
Dimmer Sensor
**Total wattage
below 60W
2700 John St. Markham ON, L3R 2W4 Canada
T: 905-474-0555
Mounting LED Light Panels
1. Fawoo LED light panels can be mounted to any wall by using “Mirror
Clip”, “U-Channel”, or simply screw mounting with pre-drilled holes in the
panel. The panels are fragile and large panels could be heavy. Make sure
the panels are secured to prevent damages. (Mounting accessories are not
supplied, but can be purchased from any local hardware store.)
2. It is recommended, but not required, to leave a little bit space between
the panels and wall for heat dissipation. The best way for heat dissipation
would be to keep the back of the panels in contact with a metal sheet which
is mounted to wall.
3. LED panels can be directly mounted to walls by drilling holes(at your
own responsibility)at locations on the panel that are away from the sides
where the LED lights and heat sinks are located.
4. LED light panels may deform (distort) due to gravity if not correctly supported with mounting products.
Mounting #14 LED Lightbox
#1
1. #14 LED lightboxes/snap frames come with mounting clips on the back.
Loosen the screw to re-locate the position of the mounting clips desired.
2. You can also turn the mounting clip 180 degrees for hanging.
#2
#3
3. Drilling holes into the frame and using mounting screw are another way
of securing the product.
Graphics Installation
1. It is recommended to print graphics on “Dura-Trans” materials for LED
light panel/lightbox applications. Do not glue printed vinyl directly to the surface of the LED light panels/lightboxes, This could change the light distribution and make the center of the panels looks darker than other areas.
2. If multiple panels are put together to form a large panel, it is recommended to leave about 1/4” space between the graphics and the LED light
panel to eliminate “hot or cold spots” along panel conjunction edges.
2700 John St. Markham ON, L3R 2W4 Canada
T: 905-474-0555
LED Light Bar Installation Guide
Wiring
1. Fawoo LED light bars are powered by Fawoo DC12V (constant voltage)
power adaptors. Do not apply any other voltages, as it may damage the
light bar. Warranty is void if using another power adaptor that are not approved by Fawoo Canada.
2. Power adaptors - same as LED light panel
5’
5’
LED Light Bar
4. Wiring multiple LED light bars - same as LED light panel
#22 AWG
Power Adaptor (3A/5A)
Spider Connector
LED Light Bar #1
Power
Adaptor
LED Light Bar #2
LED Light Bar #3
LED Light Bar #4
Power
Adaptor
Fawoo
Dimmer
LED Light Bar #1
Main
Body
LED Light Bar #2
5. If required, you can install the power adaptor in a remote location from
the LED light bars. You must cut off the DC plug and extend the cable using a larger gauge (> #16 AWG) wire to avoid a voltage drop. The wire with
a solid strip is “+” and the other wire is “-“. Reversing the polarity does not
damage the LED lights.
Dimmer Wiring
1. Fawoo LED light bars can only be dimmed with Fawoo dimmer which is
a DC dimmer. The dimmer consists of 3 components: dimmer main body,
a sensor and a remote control pad. Connect the DC plug of power adaptors and the DC plug of the bars to the dimmer main body, and securely
insert the plug of the sensor into the dimmer main body. Remove the battery
protection sheet on the remote control pad. Point the remote control to the
sensor to dim up/down the bars.
2. The dimmer maximum capacity is 60W.
3. To control multiple bars with one remote control pad, put all sensors
together.
Dimmer Sensor
Mounting LED Light Bars
1. Screws into brackets - Use screws supplied to screw mount the end-cap
to the objects to be mounted.
2. Magnets - You can also use magnet mounting by removing the adhesive
3M tape and sticking the magnets to the objects.
3. Adhesive Tape - You can also use adhesive tape by removing protective
from the tape and stick to objects.
2700 John St. Markham ON, L3R 2W4 Canada
T: 905-474-0555
DLC LumiSheet / Dongbu Lightec Canada / Fawoo Canada Terms and Conditions
Payment Terms: All POs must accompany one of the below approved payment terms for the full amount of the order prior to starting
production.
For extremely large volume and special custom orders see below for deposit details.
C) Credit Card (Max $5000.00)
Shipping: All orders are shipped F.O.B Markham, Ontario. All shipping charges will be added to invoice amount (Approved Carrier and Crat-
ing). Large / volume orders will be packed in a crate for shipping in order to avoid any possible damage during shipping. Crating dimensions
Delivery Timing: Will be provided to clients to try to meet their timelines. While we endeavour to meet your delivery requirements, Fawoo
Canada accepts no responsibility for delays of any kind, whatsoever.
Claims (Shortages / Damages): All shipments should be inspected, upon receipt, for damages and shortages. All carton(s), packing
materials and damaged item(s) must be kept in original packaging as the shipper will not honour claims. In all cases, the purchaser assumes
damage, notify the carrier immediately, and mark the bill of lading “damaged upon receipt”. In the event of Package Shortages you must
cost of replacement materials or freight expenses for goods damaged or lost in transit.
Fawoo Canada Claims (Shortages): All shipments should be inspected, upon receipt, for shortages.
of the package.
Cancellation, Returns Of Orders / Product: If there is an issue with your order, please contact our Customer Service Department
immediately. No cancellations are accepted once production started. No returns of any kind will be accepted, after a period of 2 weeks from
shipping date. Returned products must contain a Return Authorization Number that has been approved by Customer Service. Returned products must be received in one week from date of return authorization number issued date. A re-stocking charge equal to 25% of all materials
and services invoiced, together with all freight charges, apply to all returns.
Product Samples: All product samples are detailed in the “Fawoo Canada Sample Price List”. All product sample requests are to be submitted on formal PO and charged to the client at the rates provided in the sample price list”.
Limited Warranty: Fawoo Canada (“the Manufacturer”) warrants that products shall be free from defects in materials and workmanship
under normal use and proper installation for a period of two (2) years from the date of the original purchase (proof of purchase required).
The exclusive remedy and entire liability under this warranty will be for repair or replacement at manufacturer’s option.
The above warranty shall not apply to product defects resulting from (a) improper installation or maintenance; (b) misuse, neglect or accident; (c) damage during shipping or unpacking; (d) damage from hazardous environment; (e) use of power adaptor with supply voltages
replace product until the purchaser returns defective product to the Manufacturer and all balance due is paid in full. Any replacement product
may be either new or like-new, and may contain remanufactured parts, equivalent to new in performance.
Returned products are subject to inspection and evaluation at the Manufacturer’s facility. The purchaser assumes repair or replacement and
shipping cost should the returned products are deemed to be non-defective or deemed to be damaged by the purchaser. Under no circumstances, shall the Manufacturer be responsible for repair or replacement at the purchaser’s facility or at any other installation site at its own
cost.
EXCEPT FOR THE EXPRESS WARRANTIES SET FORTH ABOVE, AND TO THE EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCTS ARE
SUPPLIED ON AN “AS IS” BASIS AND THERE ARE NO WARRANTIES, REPRESENTATIONS OR CONDITIONS WHETHER EXPRESSED OR IMPLIED,
WRITTEN OR ORAL, ARISING BY STATUTE, OPERATION OF LAW, COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE, WITH RESPECT
TO THE PRODUCTS. THE MANUFACTURER SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY,
SATISFACTORY QUALITY, DURABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT.
IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SIMILAR DAMAGES,
INCLUDING ANY LOST PROFITS, INSTALLATION OR RE-INSTALLATION COSTS, OR OTHER INCIDENTIAL OR CONSEQUENTIAL OR PUNITIVE
DAMAGES, WHETHER BASED ON CONTRACT, OR ANY OTHER LEGAL THEORY, WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES, OR WHETHER SUCH DAMAGES ARE FORSEEABLE. IN ANY EVENT, THE TOTAL AGGREGATE LIABILITY OF THE MANUFACTURER FOR
DIRECT DAMAGES SHALL NOT EXCEED THE PURCHASE PRICE OF THE PRODUCT.
Dongbu Lightec / Fawoo Canada 2700 John St. Markham, Ontario (Canada) L3R 2W4
Tel: 905-474-0555
Fax: 905-479-0201 Email: info1@fawoocanada.com http://www.fawoocanada.com or http://www.dlc-lumisheet.com
Related documents
Download