Print Specifications

advertisement
FT53-CS/SWA
FT56-CS/SWA
SERIES
FIRSTRONIC SWA TRIAD OVERALL FOIL
SCREENED SPVC TINNED INSTRUMENTATION CABLES
110V RMS 90°C
APPLICATIONS:
Hazardous Areas This Steel Wire Armour cable is suitable for use for instrumentation in oil and gas industries, mine sites and other harsh
environments.
Control Electrical sensing devices to control cabinets and to supervisory consoles and panels.
ELV Signal and Controls E.L.V. power control or signal/instrumentation cables on machines, conveying equipment or similar industrial applications.
Marine Tinned Copper conductors for use in marine applications.
CONSTRUCTION:
Conductor Annealed wires of tinned stranded electrolytic copper
Insulation Special SPVC V90HT (available in LSHF on request)
Screening Collective shield of Aluminum/Polyester foil complete with Tinned copper drain wire
Armour Steel Wire Armour
Sheath Special SPVC V90 (available in LSHF on request)
CHARACTERISTICS:
Temperature Range Fixed -20°C to 90°C
Rated Voltage 110VRMS/150VDC
Minimum Bending Radius 10 x cable diameter
Sheath Colour Black (available in intrinsically safe blue and other colours on request)
Standard Core Colours Each Triad – 1 x white,1 x black, 1 red conductor, with numbered cores
Maximum Conductor Temperature 90°C
Relevant Standards AS/NZS 1125, AS/NZS 3808, IEC60332-1, IEC60332-3 CAT A, C Directive 2006/95/EC and RoHS Compliant.
PRODUCT FEATURES:
 Steel Wire Armoured for hazardous conditions
 UV Stabilised
 Heat, oil and chemical resistant (refer to chemical chart page 264)
 Extremely Pliable PVC Sheath
 Flame retardant
 Reduced flame propogation
1.5mm2
0.5mm2
Property
DC Conductor Resistance @ 20°C
Max. Capacitance Cond. To Cond. (screened)
Max. Capacitance Cond. To Scr. (screened)
Max. Capacitance Cond. To Cond. (unscreened)
Cross talk attenuation between pairs @ 1kHz (screened)
Cross talk attenuation between pairs @ 1kHz (unscreened)
Characteristic impedance @ 1kHz (screened)
Characteristic impedance @ 1kHz (unscreened)
Inductance @ 1kHz
L/R ratio @ 1kHz
Insulation Resistance @ 20°C
Value
Units
Value
Units
38.4
145
240
82
>125
>90
300
380
1.00
13.7
140
Ω/km
pF/m
pF/m
pF/m
dB/100m
dB/100m
Ω
Ω
mH/km
μH/Ω
MΩ.km
13.6
200
300
110
>125
>90
150
200
0.95
36.5
140
Ω/km
pF/m
pF/m
pF/m
dB/100m
dB/100m
Ω
Ω
mH/km
μH/Ω
MΩ.km
Firstflex has taken every precaution to ensure accurate information in this catalogue but accept no liability for any errors or omissions. Firstflex reserves the right to modify specifications at any time.
152
| P (09) 264 1000 | F (09) 264 1001 | E sales@firstflex.co.nz | W www.firstflex.co.nz

Continued Over Page

FT53/56-CS/SWA SERIES ...Continued
Part Number
Number of
Cores
x
Size
Nearest
AWG
mm2
Overall
Diameter
over
bedding
Overall
Diameter
over
Armour
No. wires
x mm2
mm
mm
mm2
Kg/Km
Approximate
Stranding
Approximate Approximate
Overall
Weight
Diameter
FT5301CS SWA
1 triple 0.5
20
7/0.30
5.9
7.7
10.6
239
FT5302CS SWA
2 triple 0.5
20
7/0.30
8.1
9.9
12.8
329
FT5304CS SWA
FT5306CS SWA
FT5308CS SWA
FT5310CS SWA
FT5312CS SWA
FT5316CS SWA
FT5320CS SWA
FT5324CS SWA
FT5336CS SWA
FT5103ES SWA
4 triple 0.5
6 triple 0.5
8 triple 0.5
10 triple 0.5
12 triple 0.5
16 triple 0.5
20 triple 0.5
24 pair 0.5
36 triple 0.5
1 triple 1.5
20
20
20
20
20
20
20
20
20
15
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.50
10.4
12.7
14.4
16.1
16.3
20.2
22.4
24.7
29.8
7.0
12.2
15.2
16.9
18.6
18.8
23.4
25.6
27.9
32.9
8.8
14.2
17.4
19.3
21.2
21.4
26.2
28.9
31.4
36.6
11.7
380
580
690
790
850
1200
1540
1680
2200
303
FT5602CS SWA
FT5604CS SWA
FT5606CS SWA
FT5608CS SWA
FT5610CS SWA
FT5612CS SWA
FT5616CS SWA
FT5620CS SWA
FT5624CS SWA
FT5636CS SWA
2 triple 1.5
4 triple 1.5
6 triple 1.5
8 triple 1.5
10 triple 1.5
12 triple 1.5
16 triple 1.5
20 triple 1.5
24 triple 1.5
36 triple 1.5
15
15
15
15
15
15
15
15
15
15
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
9.9
14.9
18.1
18.5
23.1
25.3
28.8
31.8
35.4
42.6
11.7
17.4
21.3
21.7
26.3
28.5
32.0
35.0
40.4
47.6
14.6
20.0
24.2
24.7
29.6
32.0
35.5
38.5
45.0
52.3
437
760
1130
1150
1680
2210
2840
3470
3790
4950
Part Number
FT5301CS SWA
FT5302CS SWA
FT5304CS SWA
FT5306CS SWA
FT5308CS SWA
FT5310CS SWA
FT5312CS SWA
FT5316CS SWA
FT5320CS SWA
FT5324CS SWA
FT5336CS SWA
FT5103ES SWA
FT5602CS SWA
FT5604CS SWA
FT5606CS SWA
FT5608CS SWA
FT5610CS SWA
FT5612CS SWA
FT5616CS SWA
FT5620CS SWA
FT5624CS SWA
FT5636CS SWA
Olex Cables
Product Code
IGG183AA004
IGG183AA012
IGG183AA016
B5103CS SWA
IGG184AA004
IGG184AA012
-
General Cables
Product Code
Maser
Communications
Product Code
B1526A SWA
B5304CS SWA
B5306CS SWA
B5308CS SWA
B5310CS SWA
B5312CS SWA
B5316CS SWA
B5320CS SWA
B5324CS SWA
B5336CS SWA
B1031B SWA
B5604CS SWA
B5606CS SWA
B5608CS SWA
B5612CS SWA
B5616CS SWA
B5624CS SWA
B5636CS SWA
B3020B SWA
B3021B SWA
B3022B SWA
B3024A SWA
B3046B SWA
B3048B SWA
B3052B SWA
B3054B SWA
-
Gland
Size
GMCW16 or
GMCW20SS
GMCW16 or
GMCW20SS
GMCW20S
GMCW20
GMCW25S
GMCW25S
GMCW25S
GMCW25
GMCW32
GMCW32
GMCW40
GMCW16 or
GMCW20SS
GMCW20S
GMCW25S
GMCW25S
GMCW25
GMCW32
GMCW32
GMCW40
GMCW50S
GMCW50
Firstflex has taken Firstflex
every precaution
has takentoevery
ensure
precaution
accuratetoinformation
ensure accurate
in this information
catalogue but
in accept
this catalogue
no liability
but for
accept
any errors
no liability
or omissions.
for any errors
Firstflex
or omissions.
reserves the
Firstflex
right to
reserves
modify the
specifications
right to modify
at any
specifitime.
cations at any time.
| P (09) 264 1000 | F (09) 264 1001 | E sales@firstflex.co.nz | W www.firstflex.co.nz
153
Download