INSTALLATION INSTRUCTIONS V90092 REV A Avoid Fire or Electric Shock

advertisement
INSTALLATION INSTRUCTIONS
V90092 REV A
QUIET CEILING SPECIAL CEILING
QCT906,QCT907,QCM506,QCM516 BASED SERIES
Page 1 of 3
Avoid Fire or Electric Shock
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
Fixture Mounting:
8.
Butterfly Mounting (Commercial):
1.
Fixture comes equipped with Universal Butterfly Mounting
brackets and can take common 1 inch or 1-1/2 inch Black
Iron or Galvanized Mounting Channels (Supplied By Others).
Hanger bars can be used with grid ceilings having T
bars and joist installations of wood.Adjustable hanger
bars are for use in installations with spacing from 10" to 24",
while maintaining minimum 1/2" spacing around fixture
For 10" Spacing,the hanger bar can be shortened by breaking
them at score lines as shown in Fig.2.
2.
Position Fixture so the Mounting Channels lie on top of ceiling
runners.
Grid Ceiling Installation (Figure 3):
3.
Fasten Mounting Channels securely to ceiling runners.
Step 1 Extend bar hangers between the T bars and slide the slots
in the mounting tabs over the T-bars.
4.
Secure Mounting channels to Universal Butterfly Mounting
Brackets with wire tire downs.
5.
Adjust elevation of Fixture so Aperture Ring edge
will be flush with surface of finished Ceiling by loosening two
(2) 1/4 inch Hex Screws on both Universal Mounting
Brackets. See Fig. 1.
6.
Tighten two (2) 1/4 inch Hex Screws on both Universal
Butterfly Mounting Brackets to secure Fixture. See Fig. 1.
Hanger Bar Mounting (Residential):
7.
Adjustable hanger bars are preassembled with mounting
bracket and provided with fixture.The preassembled hanger
bars must attached to the fixture prior to installation.Align with
two screws on end of fixture and tighten.Hanger bars are
installed in Fig.1.
Mounting Channel
(Supply by Others)
Fixture Housing
Cover
Step 2 Adjust housing platform position by sliding back and
forth on bar hangers to desired position. Housing may be locked
in the position by tightening bar hanger locking screws on
housing platform.See Detail 3A.
Joist Installation (Figure 4):
Step 1 Extend bar hangers to fit between joist and position
mounting tab locater lip tight to bottom of joist or framing
member. Bar hangers should be level with bottom of joist
or framing member.See Detail 4A.
Step 2 Attach bar hangers to joist or framing member using
appropriate hardware for material.
Step 3 Adjust housing platform position by sliding back and
forth on bar hangers to desired position. Housing may be locked
into position See Detail 3A.Nail Supplied in hanger bars will be
suitable.
Score Lines
10"
Bracket
Universal Butterfly
Mounting Bracket
Hanger Bar
Safety Cable
1/4" Hex Screw
Trim Mechanism
Aperture Ring
Figure 1
Figure 2
INSTALLATION INSTRUCTIONS
V90092 REV A
QUIET CEILING SPECIAL CEILING
QCT906,QCT907,QCM506,QCM516 BASED SERIES
Page 2 of 3
Avoid Fire or Electric Shock
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
Rotational Adjustment Ring
Optional
Lock Knob
Fixture
Mudding Frame
Bracket
"T"
Screw
Ceiling
Figure 3
Aperture Ring
Ball Detent Catch
Trim Mechanism
Figure 5
DETAIL 3A
DETAIL 4A
Figure 4
DETAIL AD
SCALE 2 : 1
9.
Install Ceiling drywall up to Aperture Ring on Fixture
See Fig. 5.
10.
Position Aperture Ring to be in plane with Ceiling.See Fig.5
INSTALLATION INSTRUCTIONS
V90092 REV A
Avoid Fire or Electric Shock
QUIET CEILING SPECIAL CEILING
QCT906,QCT907,QCM506,QCM516 BASED SERIES
Page 3 of 3
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
360 Rotational Lamp Adjustment (Round Trim Only)
IF LOCKING KNOB IS UNLOCKED:
11.
Rotate Trim Mechanism to desired lamp bean position by turning
Trim Mechanism up to 360 Degrees.
12.
To lock positioning, remove Trim Mechanism being careful not to
change position.
13.
Tighten Lock Knob inside Fixture to lock Rotational adjustment
Ring. See Fig.7.
14.
Be careful to align Tab Alignment Feature on Trim
Mechanism with Tab Alignment feature Notch in Rotational
Adjustment Ring while installing trim after rotational adjustment.
15.
Connect Safety Cable attached to Trim to Fixture by inserting Safety
Cable through opening in Fixture and inserting Snap Hook
(See Fig. 1) on end of Safety Cable into hole in Bracket attached to
inside of fixture.Install trim mechanism into fixture by pressing
firmly to seat Ball Detent Catches. See Fig.5.
Rotational Adjustment Ring
Tab Alignment Feature Notch
Ceiling Joist Locking Knob
Fixture
IF LOCKING KNOB IS LOCKED:
16.
Remove Trim Mechanism from Fixture.
17.
Loosen Lock Knob inside Fixture.
18.
To lock positioning, remove Trim Mechanism being careful not to
change position.
19.
Tighten Lock Knob inside Fixture to lock Rotational adjustment
Ring. See Fig.7.
20.
Be careful to align Tab Alignment Feature on Trim Mechanism with
Tab Alignment feature Notch in Rotational
Adjustment Ring.
21.
Connect Safety Cable attached to Trim to Fixture by inserting
Safety Cable through opening in Fixture and inserting Snap Hook
(See Fig. 1) on end of Safety Cable into hole in Bracket attached to
inside of fixture.Install trim mechanism into fixture by pressing
firmly to seat Ball Detent Catches.See Fig.5.