INSTALLATION INSTRUCTIONS Impact Wall LED Sheet 1 of 2 3/3/10

advertisement
Impact Wall LED
INSTALLATION INSTRUCTIONS
Sheet 1 of 2
3/3/10
IMPORTANT : READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE.
GENERAL: Upon receipt of fixture thoroughly inspect for any freight
damage, which should be brought to the attention of the delivery
carrier. Compare the catalog description listed on the packing slip with
the fixture label on the housing to be sure the correct merchandise has
been received.
SAFETY: This fixture must be wired in accordance with the National
Electrical Code, National Electrical Safety Code and applicable local
codes and ordinances. Proper grounding is required to insure personal
safety. Carefully observe grounding procedure under installation
section. This fixture is not suitable for Hazardous or Classified
Locations. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction
IMI-723
and operation of the product and hazards involved. Consult a qualified
electrician to ensure correct branch circuit conductor.
WARNING: Risk of Fire/Electric Shock. If not qualified, consult an
electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit
breaker before installing or servicing.
WARNING: Risk of burn. Disconnect power and allow fixture to cool
before servicing.
WARNING: Risk of personal injury—Fixture may become damaged
and/or unstable if not installed properly. Tighten all fixture components
to their recommended torque values.
TOOLS REQUIRED: Allen Key (3/16"), Phillips screw driver, electrical wiring
tools.
NOTE: This lighting fixture is designed for outdoor lighting services, and should
not be used in area of limited ventilation or in high ambient temperature
enclosures. It must be stored in a dry location prior to installation. Do not
expose lighting fixture to rain, dust or other environmental conditions prior to
installation. Best results will be obtained if installed and maintained according
to the following recommendations.
NOTE: Care must be taken not to set lighting fixture down on optical lenses or
lift the fixture in the lens area.
NOTE: This instruction sheet is applicable for all shapes and colors of the
IMPACT Wall Collection. The trapezoid shape is used for illustration.
APPLICATION
• Minimum 90ºC Supply Conductors when connections are made external to
the unit
• Rated for 40ºC (104ºF) ambient
• Suitable for wet location
• Wall mount luminaire only
• Construction is suitable for down mount only
• Must be mounted above grade at minimum 4 feet or higher
FIG. 1
Mounting
Orientation
Down
Mounting Plate
(Secure to J-Box or Wall)
Gasket on back
Junction Box or Wall
INSTALLATION
(2) Allen Head Screws
Mounting—FIG. 1
1. Remove the mounting plate from the fixture by loosening the two (2)
set-screws.
2. Remove the protective paper from the supplied pressure sensitive adhesive
backed gasket.
3. Align the gasket to the holes on the mounting plate and apply pressure to
secure to the back of the mounting plate.
4. Mount the gasket applied mounting plate to the junction box or wall with
the gasket away from the luminaire and secure to structure FIG. 1.
5. Slide the luminaire mounting bracket over the top lid of the mounting plate.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH091930
Impact Wall LED
Sheet 2 of 2
INSTALLATION INSTRUCTIONS
3/3/10
IMI-723
IMPORTANT : READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE.
6. Tighten the two(2) set-screws to secure the luminaire to the mounting plate.
Wiring—FIG. 2
1. The application notes, included within the unit, and instruction sheet
indicate the proper minimum supply wire rating.
2. Supply wiring is accessible within the unit when the LightBARTM mounting
plate is removed by unscrewing four (4) screws.
3. The luminaire comes standard wired for universal 120-277V driver supplied
(347V when ordered).
4. Complete the connections per the diagram FIG. 2 and the NEC or Canadian
standards using approved methods and devices.
FIG. 2
L1 (Supply)
L2 (Common)
Ground
DIMMING/BI-LEVEL SWITCHING—2L (IF EQUIPPED)
For Bi-level switching, the input leads to the fixture will be independently
labeled to indicate dimming preferences as appropriate (as defined by the
order requirements). Two [2] Separate supply lines of line voltage, neutral
and ground must be provided to the fixture to enable the bi-level switching
functionality of the fixture.
Wall
MAINTENANCE
NOTE: A regular maintenance schedule should be followed to retain optimal
light output and thermal performance.
Optical lens cleaning should be performed with a clean dry cloth to remove
any dust or other contaminants. Additional cleaning can be performed with
non-abrasive acrylic cleanser. NOTE: DO NOT USE GLASS CLEANERS.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH091930